Asian Apcolite Shine Paint

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Finishes for Interior Walls

PRODUCT CODE 1A05

Apcolite All Protek


Apcolite All Protek is a revolutionary indoor water based paint that provides all round protection to your home. Its innovative hybrid technology enhances
safety by providing excellent flame spread resistance. Its Advanced Stain Guard protects life of paint by making stains easy to clean. The Lotus effect protects
beauty of paint by ensuring water based stains do not stick to your walls.

PRODUCT BENEFITS
Flame Spread Resistance: PROTECTS YOU
Lotus Effect: PROTECTS BEAUTY OF WALL WATER
ATER BASED
A
Incase of fire inside the house, the paint on the wall
The paint has water beading technology, which is like
will resist the spread of flame. Tested for BS 476
water on lotus leaves. This ensures that water based
(Parts 6 and 7) and EN 13823 at Warrington UK
stains do not stick easily to the surface of the paint. EFFEC
and has been awarded for best performance. LO
TUS T

Advanced Stain Guard: PROTECTS LIFE OF PAINT Fragrance: GIVES PLEASANT SMELL DURING PAINTING
The paint has advanced stain guard which enables
stains to be cleaned easily. Apcolite All Protek Has a refreshing fragrance that gives a pleasant smell T
FLA
ME RET
A

during painting and reduces discomfort from paint smell.

RD
provides best stain resistance in the range.

EXCELLE

AN
CY
ADV

RD
AN
C A
ED U
ST AIN G

PRODUCT FEATURES
WASHABILITY COLOURS AVAILABLE COVERAGE

1750+
BEST IN CLASS
On smooth masonry surface by brushing
HIGH

MEDIUM

LOW
shades * 1 COAT
*Currently available in 1750+ shades
as per the Asian Paints Colour Spectra 24 -26
sq. m./L**
AVAILABLE PACKS FINISH
2 COATS
12 -13
MATT LOW SHEEN HIGH SHEEN HIGH GLOSS
sq. m./L**

SMOOTH
1L 4L 10L 20L

10L and 20L available only in Base Pure white and Refer to sheen levels in technical details. **Actual coverage may vary from the quoted coverage due
Base FSM 11. to factors such as method and condition of application and
surface roughness and porosity.

HOW TO APPLY
PRE PAINTING STEPS PAINT APPLICATION PROCESS
PLASTER New masonry APPLICATION CODE THINNER DILUTION % APPLICATION RECOATING
VISCOSITY1 PERIOD
surfaces must be allowed
to cure completely. It is STEP 1
SANDING SAND THE SURFACE WITH SAND PAPER 180 AND WIPE CLEAN
recommended to allow 28
days as the curing time for
new masonry surfaces. STEP 2
DECOPRIME CEMENT BRUSH + ROLLER
0360 WATER 30 - 40 SEC 4 - 6 HRS
CLEANING Surface should PRIMER (WT) 50% – 60%
be free from any loose paint, BRUSH / ROLLER / SPRAY
dust or grease. Growths of STEP 3
fungus, algae or moss should ACRYLIC WALL PUTTY
WATER BASED ON
PUTTY KNIFE 1354 N/A 4 - 6 HRS
be removed by wire brushing REQUIREMENT
and water. In case of areas
having excessive dampness STEP 4
use Asian Paints DampBlock SANDING SAND THE SURFACE WITH SAND PAPER 180 AND WIPE CLEAN
to limit further dampness.
When the underlying surface STEP 5
DECOPRIME CEMENT
exhibits chalkiness, in spite PRIMER (WT) 0360 WATER
BRUSH + ROLLER
30 - 40 SEC 4 - 6 HRS
50% – 60%
of thorough surface cleaning, BRUSH / SPRAY / ROLLER
use Asian Paints SmartCare
STEP 6
Exterior Sealer. SANDING SAND THE SURFACE WITH SAND PAPER 320 AND WIPE CLEAN
FILLING FOR CRACKS For
STEP 7
FIRST COAT
gaps on all interior absorbant APCOLITE ALL PROTEK
BRUSH + ROLLER BRUSH + ROLLER
1A05 WATER 30% - 40% 40-70 SEC 4 HRS
surfaces, up to 3mm width use ROLLER SPRAY 90-110 SEC
SPRAY 20%
Asian Paints SmartCare Crack
Seal as per recommended
procedure. STEP 8
BRUSH + ROLLER BRUSH + ROLLER
SECOND COAT
Asian Paints Apcolite All APCOLITE ALL PROTEK
1A05 WATER 30% - 40% 40-70 SEC 4 HRS
SPRAY 20% SPRAY 90-110 SEC
Protek should not be applied ROLLER
on surfaces / substrates that
are subjected to continuous 1. As measured through a Ford cup. 2. Recoat period is quoted for 30°C and 50-60% Relative Humidity, these may vary under different conditions. 3. Provide adequate ventilation
seepage or dampness. for application and drying. 4. Do not apply when humidity is greater than 90%. It may cause prolonged drying time of paint and moisture condensation on the walls.
Finishes for Interior Walls

HOW TO CHOOSE COLOURS

ASIAN PAINTS COLOUR COSMOS INTERIOR BOOK OF COLOURS* APCOLITE SHADE CARD*

BOOK OF COLOURS BOOK OF COLOURS


/ 2 02 0 I n te ri or s / 2 02 0 In teriors

THE THE THE THE THE THE


CONTEMPORARY CLASSIC MODERN EXPERIMENTER CONTEMPORARY CLASSIC MODERN EXPERIMENTER
V.No. 4/S
Printed by: Spectra Colourtech India Pvt. Ltd., Mumbai - 400072. 02/2019

*These shades are for reference only. Please refer to the Colour Cosmos for correct shade reference

ADDITIONAL INFORMATION

POST PAINTING CARE PRECAUTIONS


> The Golden rule for removing any wall > Do not apply when ambient temperature is less than 10°C or if the temperature might drop to
stains is that one should remove it
this level within 4 hours of application.
immediately.
> Do not over-thin or over-extend the brush.
> Remove all dirt using a clean cloth or
> Tint using Asian Paints machine colourants only.
duster. Always remove dirt from top to
bottom, this helps in avoiding loose dirt to > Stir well and strain before use.
smudge the walls. > Tinted paints need thorough shaking immediately after tinter addition as well as before use.
> For regular household stains like pencil,
tea, coffee, crayons etc, use 5% soap/
detergent solution. Use a sponge to
remove the stains. SAFETY FEATURES
> In case of tough stains like turmeric, sketch
pen, use a mild detergent solution (e.g Pril, > Kindly refer to the MSDS for Asian Paints Apcolite All Protek which gives detailed
Vim Liquid etc) for cleaning the stains.
information on safety measures while handling the paint, which is available on request.
> Store the container with the lid tightly closed in an upright position, in a cool, dry place.
> Keep out of reach of children and away from eatables.
> May be harmful if swallowed. In case of ingestion seek immediate medical attention.
> Wear eye protection during application. In case of contact with eyes, rinse immediately with
TECHNICAL DETAILS
plenty of water and seek medical advice.
a. Drying time: Surface dry time 30 minutes > In case of skin contact immediately wash skin with soap and plenty of water. Get medical
b. Recoatability: 4 – 6 hours @ ambient attention if irritation develops or persists.
condition (25ºC/65% RH) > Do not breathe vapour or spray.It is recommended to wear suitable nose pad during sanding
c. Sheen at 85ºGH on Glass Plate: <5 and surface preparation to avoid dust inhalation.
d. Flash point: Not applicable > Left-Over Paint Disposal: Left-over paint/drums should not be disposed in soil/drains.
e. Stability of Thinned Paint: Use within 24 hours > Consumers should consult a local recycling agency for proper disposal of paint/drums.

SAFETY FEATURES
> Ensure that the surface is dry. Surface Moisture (On moisture meter) is under 16%.

> Ensure the paint is cured for 2 weeks under normal atmospheric conditions.
(30ºC ; 50 - 60 % RH) prior cleaning of stains.
> Application of Acrylic Wall Putty and adherence to the painting system will lead to best results.
>
Version No. VN05/01/2021

Version No. VN05/01/2021. Please note that this datasheet supersedes all previous versions
For Feedback/complaints, write to Customer Centricity Manager, Asian Paints Limited, 6A, Shantinagar, Santacruz (E), Mumbai 400 055, Maharashtra, India.
Finishes for Interior Walls

PRODUCT CODE 1A06

Apcolite Shyne All Protek


Apcolite Shyne All Protek is a revolutionary indoor water based paint that provides all round protection to your home. Its innovative technology enhances
safety by providing excellent flame spread resistance. Its Advanced Stain Guard protects life of paint by making stains easy to clean. The Lotus effect protects
beauty of paint by ensuring water based stains do not stick to your walls.

PRODUCT BENEFITS
Flame Spread Resistance: PROTECTS YOU WATER
ATER BASED
A
Lotus Effect: PROTECTS BEAUTY OF WALL
Incase of fire inside the house, the paint on the wall
The paint exhibits water beading technology, which is like
will resist the spread of flame. Tested for BS 476 TUS
EFFEC
water on lotus leaves. This ensures that water based stains LO
T

(Parts 6 and 7) and EN 13823 at Warrington UK


do not stick easily to the surface of the paint.
and has been awarded for best performance.

Advanced Stain Guard: PROTECTS LIFE OF PAINT Fragrance: GIVES PLEASANT SMELL DURING PAINTING FLA
ME RET

The paint has advanced stain guard which enables


T A

RD
EXCELLE
Has a refreshing fragrance that gives a pleasant smell

AN
stains to be cleaned easily. Apcolite All Protek

CY
ADV
during painting and reduces discomfort from paint smell.

RD
AN
C

provides best stain resistance in the range.


ED U A
ST AIN G

PRODUCT FEATURES
WASHABILITY COLOURS AVAILABLE COVERAGE

1750+
BEST IN CLASS
On smooth masonry surface by brushing
HIGH

MEDIUM

LOW
shades * 1 COAT
*Currently available in 1750+ shades
as per the Asian Paints Colour Cosmos 24 -26
sq. m./L**
AVAILABLE PACKS FINISH
2 COATS
12 -13
MATT LOW SHEEN HIGH SHEEN HIGH GLOSS
sq. m./L**

SMOOTH
1L 4L 10L 20L

10L and 20L available only in Base Pure white and Refer to sheen levels in technical details. **Actual coverage may vary from the quoted coverage due
Base FSS 11. to factors such as method and condition of application and
surface roughness and porosity.

HOW TO APPLY
PRE PAINTING STEPS PAINT APPLICATION PROCESS
PLASTER New masonry APPLICATION CODE THINNER DILUTION % APPLICATION RECOATING
VISCOSITY1 PERIOD
surfaces must be allowed
to cure completely. It is STEP 1
SANDING SAND THE SURFACE WITH SAND PAPER 180 AND WIPE CLEAN
recommended to allow 28
days as the curing time for
new masonry surfaces. STEP 2
DECOPRIME CEMENT BRUSH + ROLLER
0360 WATER 30 - 40 SEC 4 - 6 HRS
CLEANING Surface should PRIMER (WT) 50% – 60%
be free from any loose paint, BRUSH / ROLLER / SPRAY
dust or grease. Growths of STEP 3
fungus, algae or moss should ACRYLIC WALL PUTTY
WATER BASED ON
PUTTY KNIFE 1354 N/A 4 - 6 HRS
be removed by wire brushing REQUIREMENT
and water. In case of areas
having excessive dampness STEP 4
use Asian Paints DampBlock SANDING SAND THE SURFACE WITH SAND PAPER 180 AND WIPE CLEAN
to limit further dampness.
When the underlying surface STEP 5
DECOPRIME CEMENT
exhibits chalkiness, in spite PRIMER (WT) 0360 WATER
BRUSH + ROLLER
30 - 40 SEC 4 - 6 HRS
50% – 60%
of thorough surface cleaning, BRUSH / SPRAY / ROLLER
use Asian Paints SmartCare
STEP 6
Exterior Sealer. SANDING SAND THE SURFACE WITH SAND PAPER 320 AND WIPE CLEAN
FILLING FOR CRACKS For
STEP 7
FIRST COAT
gaps on all interior absorbant APCOLITE SHYNE ALL PROTEK
BRUSH + ROLLER BRUSH + ROLLER
1A06 WATER 30% - 40% 80-110 SEC 4 HRS
surfaces, up to 3mm width use BRUSH / SPRAY / ROLLER SPRAY 30% - 40% SPRAY 80-110 SEC
Asian Paints SmartCare Crack
Seal as per recommended
procedure. STEP 8
BRUSH + ROLLER BRUSH + ROLLER
SECOND COAT
Asian Paints Apcolite Shyne All APCOLITE SHYNE ALL PROTEK
1A06 WATER 30% - 40% 80-110 SEC 4 HRS
SPRAY 30% - 40% SPRAY 80-110 SEC
Protek should not be applied ROLLER / SPRAY
on surfaces / substrates that
are subjected to continuous 1. As measured through a Ford cup. 2. Recoat period is quoted for 30°C and 50-60% Relative Humidity, these may vary under different conditions. 3. Provide adequate ventilation
seepage or dampness. for application and drying. 4. Do not apply when humidity is greater than 90%. It may cause prolonged drying time of paint and moisture condensation on the walls.
Finishes for Interior Walls

HOW TO CHOOSE COLOURS

ASIAN PAINTS COLOUR COSMOS INTERIOR BOOK OF COLOURS* APCOLITE SHADE CARD*

BOOK OF COLOURS BOOK OF COLOURS


/ 2 02 0 I n te ri or s / 2 02 0 In teriors

THE THE THE THE THE THE


CONTEMPORARY CLASSIC MODERN EXPERIMENTER CONTEMPORARY CLASSIC MODERN EXPERIMENTER V.No. 4/S
Printed by: Spectra Colourtech India Pvt. Ltd., Mumbai - 400072. 02/2019

*These shades are for reference only. Please refer to the Colour Cosmos for correct shade reference

ADDITIONAL INFORMATION

POST PAINTING CARE PRECAUTIONS


> The Golden rule for removing any wall > Do not apply when ambient temperature is less than 10°C or if the temperature might drop to
stains is that one should remove it
this level within 4 hours of application.
immediately. > Do not over-thin or over-extend the brush.
> Remove all dirt using a clean cloth or
> Tint using Asian Paints machine colourants only.
duster. Always remove dirt from top to
> Stir well and strain before use.
bottom, this helps in avoiding loose dirt to
> Tinted paints need thorough shaking immediately after tinter addition as well as before use.
smudge the walls.
> For regular household stains like pencil,
tea, coffee, crayons etc, use 5% soap/
detergent solution. Use a sponge to
remove the stains. SAFETY FEATURES
> In case of tough stains like turmeric, sketch
pen, use a mild detergent solution (e.g Pril, > Kindly refer to the MSDS for Asian Paints Apcolite Shyne All Protek which gives detailed
Vim Liquid etc) for cleaning the stains. information on safety measures while handling the paint, which is available on request.
> Store the container with the lid tightly closed in an upright position, in a cool, dry place.
> Keep out of reach of children and away from eatables.
TECHNICAL DETAILS > May be harmful if swallowed. In case of ingestion seek immediate medical attention.
> Wear eye protection during application. In case of contact with eyes, rinse immediately with
a. Drying time: Surface dry time 30 minutes
plenty of water and seek medical advice.
b. Recoatability: 4 – 6 hours @ ambient
> In case of skin contact immediately wash skin with soap and plenty of water. Get medical
condition (25ºC/65% RH)
c. Sheen at 85ºGH on Glass Plate: 27-47 attention if irritation develops or persists.
> Do not breathe vapour or spray.It is recommended to wear suitable nose pad during sanding
d. Flash point: Not applicable
and surface preparation to avoid dust inhalation.
e. Stability of Thinned Paint: Use within 24 hours >
Left-Over Paint Disposal: Left-over paint/drums should not be disposed in soil/drains.
> Consumers should consult a local recycling agency for proper disposal of paint/drums.

SAFETY FEATURES
> Ensure that the surface is dry. Surface Moisture (On moisture meter) is under 16%.

> Ensure the paint is cured for 2 weeks under normal atmospheric conditions.
(30ºC ; 50 - 60 % RH) prior cleaning of stains.
> Application of Acrylic Wall Putty and adherence to the painting system will lead to best results.
>
Version No. VN 05/01/2021

Version No. VN05/01/2021. Please note that this datasheet supersedes all previous versions
For Feedback/complaints, write to Customer Centricity Manager, Asian Paints Limited, 6A, Shantinagar, Santacruz (E), Mumbai 400 055, Maharashtra, India.

You might also like