SAIC-U-7014 - Self Propelled E. W. P.-2023

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
SELF PROPELLED ELEVATING WORK PLATFORM SAIC-U-7014 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.

1 GENERAL REQUIREMENTS:

ANSI/SAIA A92.6
1.1 Equipment documentation is available
Sec: 4.17

ANSI/SAIA A92.6
1.2 Previous inspection reports are checked
Sec: 6.15.1 (2)

GI 7.030
1.3 Daily pre-operational inspection checklists are checked (if applicable)
Para: 5.1.2

Preventive Maintenance is established and updated records are ANSI/SAIA A92.6


1.4
maintained Sec:7.6

ANSI/SAIA A92.6
1.5 Equipment is operated by a qualified operator
Sec:7.6

Warning notice, cautions or restrictions for safe operation and ANSI/SAIA A92.6
1.6
maintenance are clearly displayed and legible Sec:4.13.1(1)

A sign is posted warning the operator not to rely solely on any automatic G.I. 7.030
1.7
device as a substitute for safe operating practice Para: 5.6.2

Manufacturer name, address, serial number and model are clearly ANSI/SAIA A92.6
1.8
marked or tagged Sec:4.13.1(2)

Safe working load and number of persons are clearly marked on the ANSI/SAIA A92.6
1.9
work platform Sec: 4.13.1(3)

ANSI/SAIA A92.6
1.10 Maximum platform height and reach are clearly marked
Sec:4.13.1(4)

ANSI/SAIA A92.6
1.11 Maximum travel height and travel directions are clearly marked
Sec: 4.13.1(5)

ANSI/SAIA A92.6
1.12 Power rating are provided and marked (for AC and/or DC)
Sec: 4.13.1 (6)

ANSI/SAIA A92.6
1.13 Platform and guardrails electrical insulation data are provided
Sec:4.13.1 (11)

Multiple configurations are described on the manual and the platform (if ANSI/SAIA A92.6
1.14
multiple ratings are used) Sec:4.13.1 (10)

2 INSPECTION POINTS:

ANSI/SAIA A92.6
2.1 Platform surfaces are at least 18" (width & length) and are slip-resistant
Sec:4.12.1

ANSI/SAIA A92.6
2.2 Platform guardrails are provided and secure
Sec:4.12.2

Saudi Aramco: Company General Use


#
Saudi Aramco: Company General Use
#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
SELF PROPELLED ELEVATING WORK PLATFORM SAIC-U-7014 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
ANSI/SAIA A92.6
2.3 Platform guardrails are 42" height (+/- 3")
Sec: 4.12.2.1

ANSI/SAIA A92.6
2.4 Platform toeboard is fitted and at least 4" high
Sec: 4.12.3

ANSI/SAIA A92.6
2.5 Moving parts are guarded
Sec: 4.12.1

ANSI/SAIA A92.6
2.6 Access to the platform is provided
Sec:4.12.4

ANSI/SAIA A92.6
2.7 Access to the platform and gate inward opening with lock.
Sec: 4.12.4

ANSI/SAIA A92.6
2.8 Electrical cables, wiring and components are undamaged
Sec:4.18

ANSI/SAIA A92.6
2.9 Extendable axles function is satisfactory (where fitted)
Sec: 8.8 (1)

ANSI/SAIA A92.6
2.10 Wheels and tires are serviceable and undamaged
Sec:7.3.3 (7)

ANSI/SAIA A92.6
2.11 Safety harness anchorage is fitted in the platform
Sec:7.3.3 (3)

ANSI/SAIA A92.6
2.12 Platform controls operate the machine correctly
Sec: 4.6.1.3

Platform controls are clearly marked with direction and mode of ANSI/SAIA A92.6
2.13
operation Sec: 4.6.1 (6)

ANSI/SAIA A92.6
2.14 Platform controls accessible to the operator
Sec: 4.7.1 (1)

ANSI/SAIA A92.6
2.15 Platform controls return to "off" or "neutral" position when released
Sec: 4.6.1 (4)

ANSI/SAIA A92.6
2.16 Platform controls are protected against inadvertent operation
Sec: 4.7.1 (5)

Over-ride control for power functions is fitted at ground level control ANSI/SAIA A92.6
2.17
panel Sec:4.6.2 (1)

ANSI/SAIA A92.6
2.18 Ground controls return to "off" or "neutral" position when released
Sec:4.7.2 (3)

ANSI/SAIA A92.6
2.19 Ground controls are clearly marked for direction and mode of operation
Sec:4.6.2 (5)

ANSI/SAIA A92.6
2.20 Ground controls do not include drive and steering functions
Sec: 4.7.2 (4)

Saudi Aramco: Company General Use


#
Saudi Aramco: Company General Use
#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
SELF PROPELLED ELEVATING WORK PLATFORM SAIC-U-7014 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
ANSI/SAIA A92.6
2.21 Ground controls are protected against inadvertent operation
Sec: 4.6.2 (4)

Auxiliary (emergency) lowering, retracting and rotating controls are fitted ANSI/SAIA A92.6
2.22
and operable at platform control panel Sec:4.6.4

Auxiliary (emergency) lowering, retracting and rotating controls are fitted ANSI/SAIA A92.6
2.23
and operable at ground control panel Sec:4.6.4

ANSI/SAIA A92.6
2.24 Battery is secure, guarded and ventilated
Sec: 4.15.2

Outrigger position microswitches and interlocks are fully functional at ANSI/SAIA A92.6
2.25
their control panel Sec:4.8.2

ANSI/SAIA A92.6
2.26 Safety cables and wiring harness are available
Sec:7.3.3 (4)

ANSI/SAIA A92.6
2.27 Air, Hydraulic and fuel systems are not leaking
Sec:7.3.3 (3)

ANSI/SAIA A92.6
2.28 Emergency stop button is available at ground control station
Sec:4.6.3

ANSI/SAIA A92.6
2.29 Emergency stop button is available at platform control station
Sec: 4.7.3

There are no loose nuts, bolts, missing, worn or damaged parts around ANSI/SAIA A92.6
2.30
the structure Sec:7.3.3 (6)

ANSI/SAIA A92.6
2.31 The equipment is free of defective and/or corroded members/joints
Sec:6.6 (6)

Working environment is hazard free and machine can be safely ANSI/SAIA A92.6
2.32
operated Sec:8.9

ANSI/SAIA A92.6
2.33 An hour meter is fitted
Sec: 4.16.3

ANSI/SAIA A92.6
2.34 A fire extinguisher is fitted (type depends on operating location)
Sec:8.9

ANSI/SAIA A92.6
2.35 All fluid levels for oil, water and hydraulic are adequate
Sec: 6.6 (5)

ANSI/SAIA A92.6
2.36 All moving parts are lubricated
Sec: 6.6 (5)

ANSI/SAIA A92.6
2.37 Emergency stop button is operable from platform station
Sec: 4.7.3

ANSI/SAIA A92.6
2.38 Emergency stop button is operable from ground station
Sec: 4.7.3

Saudi Aramco: Company General Use


#
Saudi Aramco: Company General Use
#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
SELF PROPELLED ELEVATING WORK PLATFORM SAIC-U-7014 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
ANSI/SAIA A92.6
2.39 Lowering/retracting is operable from platform and ground control
Sec:6.6 (2)

ANSI/SAIA A92.6
2.40 Lowering/retracting is operable from ground control
Sec:4.7.2

ANSI/SAIA A92.6
2.41 Raise/extend is operable from platform and ground control
Sec:7.3.3 (1)

ANSI/SAIA A92.6
2.42 Boom raise/extend is operable from ground control
Sec:4.7.2 (2)

ANSI/SAIA A92.6
2.43 Fluid systems are leak-free with platform raised
Sec: 7.3.3 (4)

Tilt alarm is operable (5 degrees out of level) (manually depress the ANSI/SAIA A92.6
2.44
edge of the tilt switch to cause alarm condition) Sec: 4.6.6

Tilt alarm is not combined with boom raise cut-out (dependent on ANSI/SAIA A92.6
2.45
machine manufacturer) Sec: 4.7.6

Steering is properly working when moving forward and in reverse ANSI/SAIA A92.6
2.46
directions Sec:7.3.3 (1)

Brakes are in good working condition and can hold the machine on any ANSI/SAIA A92.6
2.47
slope (parking and moving) Sec: 4.14, 7.9 (1)

ANSI/SAIA A92.6
2.48 Travel alarm is operable
Sec:7.3.3 (2)

ANSI/SAIA A92.6
2.49 Platform lowering alarm is operable
Sec: 4.11.2

Machine is safely drivable from the platform when raised (fast, slow, ANSI/SAIA A92.6
2.50
forward and reverse modes) Sec: 4.8.1

The platform does not descend when in raised position and the power is ANSI/SAIA A92.6
2.51
off Sec: 4.10.2.1

Used ancillary equipment are in good condition, free of damages and do


ANSI/SAIA A92.6
2.52 not create any hazardous condition (e.g. power sockets, extension
Sec: 4.15.1
cables and mechanical brackets)

ANSI/SAIA A92.6
2.53 Engine powered machines fuel lines are supported to minimize chafing
Sec:4.15.1

Engine powered machines fuel lines are positioned to minimize ANSI/SAIA A92.6
2.54
exposure to engine and exhaust heat Sec: 4.15.1

ANSI/SAIA A92.6
2.55 Engine powered machines exhaust system is provided with muffler
Sec: 4.15.1

REMARKS:

Saudi Aramco: Company General Use


#
Saudi Aramco: Company General Use
#

SAIC NUMBER ISSUE DATE DISCIPLINE


SAUDI ARAMCO INSPECTION CHECKLIST
SELF PROPELLED ELEVATING WORK PLATFORM SAIC-U-7014 1-Jan-23 ELEVATING/LIFTING EQUIPMENNT
PROJECT TITLE WBS/BI/JO NUMBER INSPECTION COMPANY

EQUIPMENT ID NUMBER EQUIPMENT DESCRIPTION/TYPE SERIAL NO. REPORT No.:

CAPACITY (SWL) MANUFACTURER FACILITY / LOCATION

REQUESTED INSPECTION DATE RFI No. TASK COMPLETED DATE EQUIPMENT OWNER

ITEM
ACCEPTANCE CRITERIA REFERENCE PASS FAIL N/A Remark
No.
REFERENCE DOCUMENTS:
1- ANSI/SAIA A92.6 - 2006(R2014) Issue:Self - Propelled Elevating Work Platforms
2- SAES-B067 - 2020 Issue: Safety Identification and Safety Colors
3- SA GI 7.025-2018 Issue: Heavy Equipment Operator and Rigger Testing and Certification
4- SA GI 7.030 - 2023 Issue: Inspection and Testing Requirements for Elevating/Lifting Equipment

Load Tested By (If Applicable):


Name, Signature, & Date:

□ Inspected □ Witnessed by 3rd Party Certified Inspector:


Name, Signature, Certificate No. & Company:

User Representative:
Name, Signature, & Date:

Saudi Aramco: Company General Use


#
Saudi Aramco: Company General Use