Total

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Freight Elevator Series GFM-T

Our Freight Elevators


Basic Specifications
Can Improve
Your Goods-Handling Ability
The following dimension is shown in Japan code.
Car interior (mm) Entrance (mm)
Capacity Speed
Loading equipment and scope of application Type Width Depth Door type Width Height
(kg) (m/min.)
(AA) (BB) (JJ) (HH)
F-750-2S 750 1300 2300 2S 1100 2100 45/60
F-1000-2S 1000 1700 2300 2S 1400 2100 45/60

Elevator Selection F-1500-2S


F-2000-2S
1500
2000
2200
2200
2400
2800
2S
2S
1700
1700
2100
2100
45/60
45/60
F-2500-3S 3S 2300
1. Rated capacity and car size
F-2500-2U 2500 2500 3000 2U 2500 2500 45/60
F-2500-3U 3U 2500
What is the maximum F-3000-3S 3S 2300
weight or size of goods Is a forklift used to load Check shaft size and Set rated F-3000-2U 3000 2500 3400 2U 2500 2500 45/60
Select car size capacity
to be transported and unload goods? loading area F-3000-3U 3U 2500
at one time? F-3500-3S 3S 2400
F-3500-2U 3500 2800 3800 2U 2800 2500 45/60
F-3500-3U 3U 2800
F-4000-2CO 2CO 2400
Driving system Traction type F-4000-2U 4000 3000 4500 2U 3000 2500 30/45
Machine room location Directly over the hoistway F-4000-3U 3U 3000
Rated capacity *1 750kg∼6000kg F-4500-2CO 2CO 2500 2500
Rated speed *1 30m/min.∼60m/min. F-4500-2U 4500 3200 4500 2U 3200 30/45
3000
Maximum travel 30m F-4500-3U 3U 3200
Overhead, Pit depth F-5000-2CO 2CO 2500 2800
Refer to pages 7 to 10
Motor capacity F-5000-2U 5000 3200 5000 2U 3200 30/45
3000
*1: Combinations between capacity and speed are shown in the table on the next page. F-5000-3U 3U 3200
F-6000-2CO 2CO 2700 2800
2. Operation system F-6000-2U 6000 3500 5800 2U 3500 30
3000
Operation system Outline Remarks F-6000-3U 3U 3500
Responds to individual calls. It cannot General operation system for typical Note: 1. Freight elevators of less than 2500kg capacity can only be loaded by handtrucks with casters. Goods cannot be loaded by forklift.
Single automatic for freight 1BF
register new calls during operation. freight uses. Please consult our sales agency if you plan to use a forklift to load and unload goods with our traction-type freight elevators of 2500kg capacity or more.
2. In cases where capacity exceeds 3000kg, please consult our sales agency for details.
Responds in sequence to calls in the 3. 2U, 3U door type can not be applied for EN-81-1 or GB code.
Selective collective 2BC same direction. It allows both Applicable for handling small goods.
directions per call.

3. Door system
Door type Remarks
2S: 2-panel side opening
Horizontal
3S: 3-panel side opening These door types have comparatively fast operation.
sliding doors
2CO: 4-panel center opening
Vertical 2U: 2-panel upward opening These door types make it easy to align same-size entrance width and car width.
sliding doors 3U: 3-panel upward opening Note: Not applicable with 2BC operation.

1 2
Car and Entrance Designs Operation System
Signal fixtures such as Car operating panel and Hall position indicator, etc., are shown according to operation system.
The applications vary based on the model, so please confirm when ordering.

E-102 FC-101-2S Finishes and Designs 2-panel side opening


Single automatic for freight (1BF) : Standard
Selective collective (2BC) : Optional
Door frame Narrow Jamb with Painted steel sheet Signal fixtures Functions Remarks
Entrance Doors Painted steel sheet Direction arrow Shows direction during operation.
Extruded hard aluminum (Capacity of
2000kg or less) Position indicator Shows position of elevator.
Entrance Sill
Steel plate with black paint (Over IN-USE indicator Shows elevator is in use. Only 1BF
2000kg capacity)
Push to register call. Invalid while IN-USE
Indicator is incorporated in Hall button Hall position indicator Call button Only 1BF
Hall buttons indicator is illuminated.
unit.
Up call button Push to go up. Only 2BC
Car Ceiling Painted steel sheet
Car Walls Painted steel sheet Down call button Push to go down. Only 2BC
Car Doors Painted steel sheet Door close button Close doors promptly for next user. Only 1BF
Flooring Checkered steel plate with black paint
Direction arrow Shows direction during operation.
Car Sill Same as Entrance Sill
Lighting LEDs Position indicator Shows position of elevator.
Car wall protectors Stainless steel hairline (Optional) Intercom Enables contact with building superintendents.
*Signal fixtures shown above are for Single automatic
operation for freight (1BF). (Standard)
Keep pushing in times of emergency to enable
Alarm button
the elevator operator contact with outside.
When pressed during an emergency, the
Emergency stop switch
E-202 FC-101-3S Finishes and Designs 3-panel side opening elevator immediately stops.
Car operating panel Car button Press for the destination floor.
Door frame Square Jamb with Painted steel sheet
(Optional)
Door open button Press to re-open the doors when doors are closing.
Entrance Doors Painted steel sheet Door close button Keep pressing until the car starts with doors closed. Only 2BC
Extruded hard aluminum (Capacity of There are switches inside for maintenance and
2000kg or less) Swing door
Entrance Sill administrative purposes.
Steel plate with black paint (Over
2000kg capacity) Key hole Turn the key to the left to open swing door.
Indicator is incorporated in Hall button
Hall buttons
unit.

Car Ceiling Painted steel sheet


Car Walls Painted steel sheet Single automatic for freight (1BF) Selective collective (2BC)
Car Doors Painted steel sheet
Flooring Checkered steel plate with black paint
Car Sill Same as Entrance Sill
Lighting LEDs
*Signal fixtures shown above are for Selective collective
operation (2BC). (Optional)
Note: Car operating panel is installed in Front return panel.

E-102 FC-101-2U Finishes and Designs 2-panel upward opening

Door frame Narrow Jamb with Painted steel sheet


Entrance Doors Painted steel sheet
Entrance Sill Checkered steel plate with black paint
Indicator is incorporated in Hall button
Hall buttons
unit.

Car Ceiling Painted steel sheet


Car Walls Painted steel sheet
Car Doors Expanded metal with painted finish PIM-J10 PIM-C110
Flooring Checkered steel plate with black paint
Lighting LEDs
*Signal fixtures shown above are for Single automatic
operation for freight (1BF). (Standard)

CBM-J31 CBM-C111

3 4
Specifications

•: Standard ○: Optional •: Standard ○: Optional


Item Descriptions Application Item Descriptions Application

Walls and Transom Panel


Painted steel sheet • Inter Communication System (ITP)
A system which allows communication between passengers

Stainless steel hairline ○ inside a car and the building personnel.

Panel Doors (Horizontal Sliding Doors)


Painted steel sheet • Emergency Car Lighting (ECL-C) Car lighting which turns on immediately when power fails to

Doors Stainless steel hairline ○ (Rechargeable Battery Type) provide a minimum level of lighting within the car.
Steel Mesh Doors (Vertical Sliding Doors) Expanded metal with painted finish • Car Fan Shut Off – Automatic (CFO-A)
If there are no calls for a specified period, the car ventilation

Ceiling Painted steel sheet • fan will automatically be turned off to conserve energy.
Lighting LEDs • If there are no calls for a specified period, the car lighting will

Car

Car Light Shut Off – Automatic (CLO-A)


Ventilation Diffuser fan ○ automatically shut off to conserve energy.
Entrance Columns (Only Horizontal Sliding Doors) Stainless steel hairline • Hall Out of Service Switch (HOS)
For maintenance or energy-saving measures, a car can be taken out

Car Wall Protectors Stainless steel hairline ○ of service temporarily with a key switch mounted in a specified hall.


Appearance

Flooring Checkered steel plate with black paint Necessary wires are provided in the traveling cable.
Wiring for BGM Speaker ○
Capacity of 2000kg or less Extruded hard aluminum • (Speaker: by owner)
Sill Over 2000kg Capacity Steel plate with black paint • Mitsubishi Emergency Landing Device (MELD) Upon power failure, a car equipped with this function

Operational Features
Vertical Sliding Doors Same unit as car flooring automatically moves and stops at the nearest floor using a

Narrow Jamb
Painted steel sheet • rechargeable battery, and the doors open to ensure passenger
Stainless steel hairline ○ safety. (Max. allowable floor-to-floor distance is 10 meters.)
Door Frame
Painted steel sheet ○ Earthquake Emergency Return (EER-P / EER-S) Upon activation of primary and/or secondary wave seismic
Splayed Jamb / Square Jamb
Stainless steel hairline ○ sensors, all cars stop at the nearest floor, and park there with ○
Entrance

Doors
Painted steel sheet • the doors open to facilitate safe evacuation of passengers.
Stainless steel hairline ○ Fire Emergency Return (FER) Upon activation of a key switch or a building’s fire sensors, all
Capacity of 2000kg or less Extruded hard aluminum • calls are canceled, all cars immediately return to a specified

Sill Over 2000kg Capacity Steel plate with black paint • evacuation floor and the doors open to ensure safe passenger
Vertical Sliding Doors Checkered steel plate with black paint • evacuation.
Car Operating Operation by Emergency Power Source – Upon power failure, the car uses the building’s emergency
Faceplate Stainless steel hairline

Signals

Panel Auto/Manual (OEPS) power supply to move to a specified floor, where the doors
Hall Position then open to facilitate the safe evacuation of passengers. ○
Indicator
Faceplate Stainless steel hairline
• After the car has arrived at the floor, normal operation will
The sensitive mechanical door edge detects the operator or be available.
Safety Door Edge (SDE)
goods upon contact during door closing. • Supervisory Panel (WP) A panel installed in a building’s supervisory room, etc., which
Horizontal Sliding Doors Car side The infrared-light beam (one or two) covers the full width of monitors and controls each elevator’s status and operations
○ ○
Operational Features

Car side the door as it opens or closes to detect the operator or goods. by remote, using indicators and switches which are provided
Safety Ray (SR)
Vertical Sliding Doors The infrared-light beam is installed in the door frame. on request.
Entrance side ○
The feature is the same as car side.
Overload Holding Stops (OLH) The elevator buzzer rings to indicate the car is overloaded. •
The doors are automatically closed after a predetermined time
Automatic Door Closing (ADC) (Only 1BF) (std. 1 min.) from full opening. The buzzer will continue to ring ○

from 8 sec. before closure until the doors are fully closed.
This feature keeps the doors open for a predetermined period
Extended Door-Open Button (DKO-TB) (Only 2BC) ○
to facilitate loading and unloading of goods.

5 6
Layout Drawings and Dimensions for One Gate (1D1G)
For JIS Code

The following dimension is shown in Japan code.


Machine room Pit depth Min. floor Overhead Reaction loads (kN)*2
Capacity Speed Motor Hoistway (mm)
Type (mm) PD Door type height OH Machine room Pit
(kg) (m/min.) (kW)*1
AM✕BM (mm) X✕Y (mm) (mm) R1 R2 R3 R4
45 7.5 1250 4450 70.6 55.4
Hoistway Plan for 2-panel Hoistway Plan for 3-panel Hoistway Plan for 2-panel F-750-2S 750 2600 ✕ 3950 2S 2200 ✕ 2900 2800 44.6 36.7
side opening door (2S) side opening door (3S) upward opening door (2U) 60 9.5 1550 4650 71.6 55.4
It can not be applied for EN-81-1 or GB code.
45 7.5 1250 4450 80.4 66.2
F-1000-2S 1000 3150 ✕ 3950 2S 2600 ✕ 2900 2800 74.6 43.1
60 9.5 1550 4650 84.8 73.1
45 9.5 1250 4450 119.6 82.4
F-1500-2S 1500 3600 ✕ 4050 2S 3150 ✕ 3000 2800 101 53.9
60 13 1550 4650 129.4 88.3

AA
AA
AA 45 13 1250 4450 139.2 103
F-2000-2S 2000 3600 ✕ 4250 2S 3150 ✕ 3400 2800 121.6 63.7
60 18.5 1550 4650 150 109.8
45 18.5 1250 4850 192.2 144.2

Y
Y

F-2500-3S 4000 ✕ 4400 3S 3600 ✕ 3700 3300 148.1 81.4


BB
BB

60 22 1550 5050 206 154

BB
45 18.5 1250 4850 192.2 144.2
F-2500-2U*4 2500 4000 ✕ 4400 2U 3600 ✕ 3700 4500 155.9 80.4
60 22 1550 5050 206 154
45 18.5 1250 4850 192.2 144.2
JJ JJ JJ F-2500-3U*4 4000 ✕ 4400 3U 3600 ✕ 3700 3950 155.9 80.4
60 22 1550 5050 206 154
X X X
45 18.5 1250 4850 208 154
F-3000-3S 4100 ✕ 4800 3S 3750 ✕ 4100 3300 166.7 92.2
60 26 1800 5050 223 165
45 18.5 1250 4850 208 154
F-3000-2U*4 3000 4100 ✕ 4800 2U 3750 ✕ 4100 4500 174.5 92.2
60 26 1800 5050 223 165
45 18.5 1250 4850 208 154
F-3000-3U*4 4100 ✕ 4800 3U 3750 X 4100 3950 174.5 92.2
Machine Room Plan Hoistway Section 60 26 1800 5050 223 165
*1: Since required motor power varies according to the specifications, such as elevator cage weight, etc., please consult our sales agency for details.
*2: Since reaction load varies according to the specifications, please consult our sales agency for details.
Min. clear
machine

height

*3: In cases where capacity exceeds 3000kg, please consult our sales agency for details.
room

Cinder concrete
finish (by owner) *4: 2U, 3U door type can not be applied for EN-81-1 or GB code.
Ventilating fan (by owner)
100
Overhead OH

R1
R2
Y
BM

Max. Travel 30m

Control
panel
Access door
Min. floor height

Entrance height HH

W1200XH2000

Ventilation
hole (by owner)
X
AM
Pit depth
PD

2-panel upward 3-panel side 2-panel side


opening door opening door opening door R3 R4

7 8
Layout Drawings and Dimensions for Two Gates (1D2G & 2D2G)
For JIS Code

The following dimension is shown in Japan code.


Machine room Pit depth Min. floor Overhead Reaction loads (kN)*2
Capacity Speed Motor Hoistway (mm)
Type (mm) PD Door type height OH Machine room Pit
(kg) (m/min.) (kW)*1
AM✕BM (mm) X✕Y (mm) (mm) R1 R2 R3 R4
45 7.5 1250 4450 77.4 64.7
Hoistway Plan for 2-panel Hoistway Plan for 3-panel Hoistway Plan for 2-panel F-750-2S 750 2600 ✕ 3950 2S 2200 ✕ 3110 2800 50.5 41.5
side opening door (2S) side opening door (3S) upward opening door (2U) 60 9.5 1550 4650 78.5 69.6
45 7.5 1250 4450 96.1 75.5
F-1000-2S 1000 3150 ✕ 3950 2S 2600 ✕ 3110 2800 83.4 48
60 9.5 1550 4650 104 80.4
JJ JJ JJ
45 9.5 1250 4450 127.4 98
F-1500-2S 1500 3600 ✕ 4050 2S 3150 ✕ 3210 2800 112.8 59.8
60 13 1550 4650 137.2 106.8

AA AA 45 13 1250 4450 151 116.7


AA
F-2000-2S 2000 3600 ✕ 4250 2S 3150 ✕ 3610 2800 135.3 69.6
60 18.5 1550 4650 162.8 125.5
45 18.5 1250 4850 205 157
Y

3S

Y
F-2500-3S 4000 ✕ 4400 3600 ✕ 3970 3300 163.8 84.3
Y
BB

BB
60 22 1550 5050 219 168
BB

45 18.5 1250 4850 205 157


F-2500-2U*4 2500 4000 ✕ 4400 2U 3600 ✕ 3680 4500 166.7 89.3
60 22 1550 5050 219 168
45 18.5 1250 4850 205 157
JJ JJ JJ
F-2500-3U*4 4000 ✕ 4400 3U 3600 ✕ 4000 3950 166.7 89.3
X X X 60 22 1550 5050 219 168
45 18.5 1250 4850 217.8 182.4
F-3000-3S 4100 ✕ 4800 3S 3750 ✕ 4370 3300 201 106.9
60 26 1800 5050 233 195
45 18.5 1250 4850 217.8 162.8
F-3000-2U*4 3000 4100 ✕ 4800 2U 3750 ✕ 4080 4500 206.9 110.8
60 26 1800 5050 233 174
45 18.5 1250 4850 217.8 162.8
F-3000-3U*4 4100 ✕ 4800 3U 3750 X 4400 3950 206.9 110.8
Machine Room Plan Hoistway Section 60 26 1800 5050 233 174

*1: Since required motor power varies according to the specifications, such as elevator cage weight, etc., please consult our sales agency for details.
*2: Since reaction load varies according to the specifications, please consult our sales agency for details.
*3: In cases where capacity exceeds 3000kg, please consult our sales agency for details.
Min. clear
machine

height
room

Cinder concrete *4: 2U, 3U door type can not be applied for EN-81-1 or GB code.
Ventilating fan (by owner) finish (by owner)
100
Overhead
OH

R1
Y
BM

R2
Max. Travel 30m

Control
Min. floor height

panel
Entrance height HH

Access door
W1200×H2000

Ventilation
hole (by owner)
X
Pit depth

AM
PD

2-panel upward 3-panel side 2-panel side R4 R3


opening door opening door opening door

9 10
Entrance Layouts

2-panel side opening door 4-panel center opening door


(2S) (2CO)

70
30
132

Entrance height HH
137

135
thickness 28

Jamb depth JD
Wall

(100)
70
Entrance width JJ 100

Finish
150
100 200

Entrance height HH
30

60
132
137

135 200
28
thickness

Jamb depth JD

135 30
(50 or 100)
Wall

Entrance width JJ 100 150


Finish

60
100 200 2-panel upward opening door
200
(2U)
It can not be applied for EN-81-1 or GB code.
135 30

Sill width
140 *1

30 *1

Entrance height HH
140 *1
Jamb depth JD
Entrance width JJ

(100)
100
3-panel side opening door 100 200
(3S)

60
140 *1 30 *1
70
30

3-panel upward opening door


(3U)
169
174

Entrance height HH
175

It can not be applied for EN-81-1 or GB code.


thickness 31

Sill width
200 *1
Jamb depth JD

60
(100)
Wall

Entrance height HH
Entrance width JJ 100
Finish

200 *1
150
100 200
60

Jamb depth JD
240
Entrance width JJ

(100)
100
100 200
175 30

60
*1: Since dimensions for vertical sliding doors vary according to the entrance width, entrance height 60
and floor height, please consult our sales agency for details.
200 *1

11 12
Electrical Installation Important Information on Elevator Planning

Electrical Equipment Required for Elevator Operation Work Not Included in Elevator Contract
The following items are excluded from our elevator
Elevator Site Requirements
•The temperature of the machine room and elevator
installation work, and are therefore the hoistway shall be below 40°C.
ELECTRICAL ROOM
ELEVATOR MACHINE ROOM responsibility of the building owner or general contractor: •The following conditions are required for maintaining
NF breaker *2
Vent. fan
Celling-lighting equipment •Construction of the elevator machine room with proper elevator performance.
a. The relative humidity shall be below 90% on a monthly
Control panel Traction beams and slabs, equipped with a lock, complete with
Traction-machinery power supply motor illumination, ventilation and waterproofing. average and below 95% on a daily average.
3-phase Ground wire *1 Receiving box •Access to the elevator machine room sufficient to allow b. The machine room and the elevator hoistway shall be
finished with mortar or other materials so as to prevent
transformer passage of the control panel and traction machine.
Power outlet Ventilation
•Architectural finishing of the machine room floor, and the concrete dust.
Lighting power supply
window
walls and floors in the vicinity of the entrance hall after •Voltage fluctuation shall be within a range of +5% to -10%.
1-phase
transformer Receiving
installation has been completed.
box •Construction of an illuminated, ventilated and Ordering Information
Inter waterproofed elevator hoistway. Please include the following information when ordering or
Communication •A ladder to the elevator pit. requesting estimates:
System
•The provision of cutting the necessary openings and joists. •The desired number of units, speed and loading capacity.
*1: The minimum size of ground wire is determined according to the ampere •Separate beams, when the hoistway dimensions markedly •The number of stops or number of floors to be served.
rating of the NF breaker installed at the power source side.
Supervisor's Car
exceed the specifications, and intermediate beams when •The total elevator travel and each floor-to-floor height.
*2: The current rating of the power-source NF breaker should be of one level room two or more elevators are installed. •Operation system.
larger than that of the receiving-box NF breaker installed in the elevator Pit •All other work related to building construction. •Selected design and size of car.
machine room.
power outlet
•The machine room power-receiving panel and the •Entrance design.
electrical wiring for illumination, plus the electrical wiring •Signal equipment.
Inter Communication System (where necessary)
from the electrical room to the power-receiving panel. •A sketch of the part of the building where the elevators are
Traction-Machinery Power Supply •The laying of conduits and wiring between the elevator pit to be installed.
It is necessary to install power-supply equipment of This is essential for establishing communication between and the terminating point for the devices installed outside •The voltage, number of phases, and frequency of the
sufficient capacity to ensure the elevators accelerating elevator operator or passengers and outside in case of the hoistway,such as the emergency bell, intercom, power source for the motor and lighting.
smoothly and landing accurately. The power supply should emergency. The master station transceiver is usually in a monitoring and security devices, etc.
be kept within a voltage- fluctuation range of +5 ~ -10%, and a location readily accessible to the supervisor, in the central •The power consumed in installation work and test
voltage-imbalance factor of 5%. When selecting protective supervisor's room or elevator lobby. The wiring work operations.
breakers on the power-supply side, be guided by voltage between the master station and the elevator machine room •All the necessary building materials for grouting in of
ratings of the no-fuse breakers supplied with the elevators. is not included in the elevator contract. To facilitate piping brackets, bolts, etc.
and wiring, it is desirable to decide on the position of the •The test provision and subsequent alteration as required,
Power Supply for Lighting master station at the earliest stage of building design. and eventual removal of the scaffolding as required by the
Lighting for the elevator cars and indicators should, where elevator contractor, and any other protection of the work
possible, be supplied via a separate circuit that will not be Lighting Equipment as may be required during the process.
affected by power failures elsewhere. The machine room should be fitted with good lighting for •The provision of a suitable, locked space for the storage of
maintenance work. The light switch should be positioned elevator equipment and tools during elevator installation.
Ventilation Equipment close to the machine-room entrance. •The security system, such as a card reader, connected to
A machine-room ventilating fan of a capacity to keep the our elevator controller, when supplied by the building
room below 40˚C is required. A ventilation window should Inspection Power Outlets owner or general contractor.
also be installed opposite the ventilation fan. These should be installed in the machine room and pit for * Work responsibilities in installation and construction shall be
use during inspections and maintenance. determined according to local laws. Please consult our local
agents for details.

Power Feeder Data


Power Feeder Data
Capacity Speed Motor Power supply (200V) Power supply (400V) Power
Heat
(kg) (m/min.) (kW) Current Receiving Current Receiving supply
emission
box NF- box NF- capacity
FLU (A) FLAcc (A) FLU (A) FLAcc (A) (W)
breaker (A) breaker (A) (kVA)
45 7.5 30 69 50 15 35 30 7 1000
750
60 9.5 38 89 60 19 45 30 8 1350
45 7.5 32 64 50 16 32 30 7 1350
1000
60 9.5 41 84 75 21 42 40 9 1750
45 9.5 45 87 75 23 44 40 10 2000
1500
60 13 57 114 100 29 57 50 12 2650
45 13 57 110 100 29 55 50 12 2650
2000
60 18.5 73 143 125 37 72 60 15 3500
45 18.5 73 147 125 37 74 60 15 3300
2500
60 22 93 191 150 47 96 75 19 4400
45 18.5 77 157 125 39 79 60 17 3950
3000
60 26 98 205 150 49 103 75 22 5250

13 14
Our elevators and escalators are currently operating in approximately 90 countries around the globe. Built placing priority on safety, our
elevators, escalators and building system products are renowned for their excellent efficiency, energy savings and comfort.
The technologies and skills cultivated at the Inazawa Building Systems Works in Japan and 12 global manufacturing factories are utilized
in a worldwide network that provides sales, installation and maintenance in support of maintaining and improving product quality.
As a means of contributing to the realization of a sustainable society, we consciously consider the environment in business operations,
proactively work to realize a low-carbon, recycling-based society, and promote the preservation of biodiversity.

Mitsubishi Electric Building Solutions Corporation Inazawa Building Systems Works has acquired ISO 9001 certification from the International
Organization for Standardization based on a review of quality management. The plant has also acquired environmental management system
standard ISO 14001 certification.

www.MitsubishiElectric.com/elevator

Revised publication, effective Sep. 2022.


Superseding publication of L-170-2-C5812-M Nov. 2020.
Specifications are subject to change without notice.

L-170-2-C5812-N INA-2209 Printed in Japan (IP) 2022 Mitsubishi Electric Building Solutions Corporation

You might also like