Contact data
Number and type of contacts 3 CO
Contact material AgNi, AgNi/Au 0,2 µm
Rated / max. switching voltage AC 250 V / 440 V
Min. switching voltage 10 V
Rated load (capacity) AC1 10 A / 250 V AC
AC15 3 A / 120 V 1,5 A / 240 V (B300)
AC3 370 W (single-phase motor)
DC1 10 A / 24 V DC (see Fig. 3)
DC13 0,22 A / 120 V 0,1 A / 250 V (R300)
Min. switching current 5 mA
Max. inrush current 20 A
Rated current 10 A
Max. breaking capacity AC1 2 500 VA
Min. breaking capacity 0,3 W
Contact resistance 100 m
Max. operating frequency
• at rated load AC1 1 200 cycles/hour
• no load 18 000 cycles/hour
Coil data
Rated voltage 50/60 Hz AC 6 ... 240 V
DC 5 ... 220 V
Must release voltage AC: 0,2 Un DC: 0,1 Un
Operating range of supply voltage see Tables 1, 2
Rated power consumption AC 1,6 VA
DC 0,9 W
Insulation according to PN-EN 60664-1
Insulation rated voltage 250 V AC
Rated surge voltage 4 000 V 1,2 / 50 µs
Overvoltage category III
Insulation pollution degree 2
Dielectric strength
• between coil and contacts 2 500 V AC type of insulation: basic
• contact clearance 1 500 V AC type of clearance: micro-disconnection
• pole - pole 2 500 V AC type of insulation: basic
Contact - coil distance
• clearance 2,5 mm
• creepage 4 mm
General data
Operating / release time (typical values) AC: 10 ms / 8 ms DC: 13 ms / 3 ms
Electrical life
• resistive AC1 > 105 10 A, 250 V AC
• cos see Fig. 2
Mechanical life (cycles) > 2 x 107
Dimensions (L x W x H) 27,5 x 21,2 x 35,6 mm
Weight 35 g
Ambient temperature • storage -40...+85 oC
• operating AC: -40...+55 oC DC: -40...+70 oC
Cover protection category IP 40 PN-EN 60529
Environmental protection RTI PN-EN 116000-3
14.07.2014
www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
R3N
miniature industrial relays
NEW TECHNOLOGY
The new R2N, R3N, R4N relays are modernized versions
of the R2, R3, R4 relays. The modernization covered
the design of the relays and the manufacturing process.
14.07.2014
www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
R3N
miniature industrial relays
with extra equipment D - surge suppression element (diode) tion of the relay.
- for DC coils only.
Strengthening of the insulation in the area of the
contact plate: polyamide PA66 has been applied; it has
very good mechanical and electrical parameters and best
thermal properties. 3
www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
R3N
miniature industrial relays
Electrical life at AC resistive load. Fig. 1 Electrical life reduction factor Fig. 2
Switching frequency: 1 200 cycles/hour at AC inductive load
N
Number of cycles
Reduction factor
Power factor
N - electrical life
Breaking capacity [kVA] at AC1
DC voltage [V]
www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
R3N
miniature industrial relays
Ordering codes
Cover protection
category
R 3 N — — — —
Contact material
20 - AgNi
21 - AgNi/Au 0,2 µm see Tables 1, 2 page 2
Connection mode
3 - for plug-in sockets
Additional features
without marks - without additional features
WT - mechanical indicator + lockable front test button ❷
WTL - mechanical indicator + lockable front test button + light indicator (LED diode)
WTD - mechanical indicator + lockable front test button + surge suppression element (diode) ❸
WTLD - mechanical indicator + lockable front test button + light indicator (LED diode) + surge suppression element (diode) ❸
Note:
For relays with additional features D - surge suppression element (diode) (versions WTD and WTLD) - fixed supply
polarity compulsory for the DC load of coils: +A1(13) / -A2(14). The polarity is indicated on the relay cover. For other
versions of the relays with DC coils any polarity is possible.
www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
Plug-in sockets and accessories
COM
GZT4-0040 G4 1052
❶ Mounting and sub-assemblies of accessories in the socket - see page 6. Signalling / protecting modules type M... - see page 7.
❷ In the bracket the height of socket with retainer / retractor clip is shown.
Description plate
14.07.2014
Screw terminals
plug-in socket
www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
Signalling / protecting modules type M...
LED red
– M...R
LED green
– M...G
14.07.2014
PRECAUTIONS:
1. Ensure that the parameters of the product described in its specification provide a safety margin for the appropriate operation of the device or system and never use
the product in circumstances which exceed the parameters of the product. 2. Never touch any live parts of the device. 3. Ensure that the product has been connected
correctly. An incorrect connection may cause malfunction, excessive heating or risk of fire. 4. In case of any risk of any serious material loss or death or injuries
of humans or animals, the devices or systems shall be designed so to equip them with double safety system to guarantee their reliable operation.
www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
Interconnection strips ZGGZ4
PIR2-...-00L.
(R2N + GZM2)
ZGGZ4
www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
Additional features for industrial relays
Industrial relays for plug-in sockets: R2N, R3N, R4N, R15 - 2 CO ❺, R15 - 3 CO ❺ with WT features as stan-
dard (W - mechanical indicator + T - lockable front test button). Detailed information on additional features
of individual relays can be found in the data sheets on the side of ”Ordering codes”.
❹ Available combinations:
WT, WTL, WTD, WTLD - in relays R2N, R3N, R4N for plug-in sockets
L, D, LD - in relays RY2 for plug-in sockets
WT, WTL, WTD, WTLD, WTV, WTLV - in relays R15 - 2 CO, 3 CO for plug-in sockets
K, L, D, KL, KD, LD, KLD - in relays R15 - 4 CO for plug-in sockets
K, L, KL - in relays RUC
L - in relays RUC-M
❺ Voltage versions, in covers
orange
– AC coils
green
– DC coils
14.07.2014
www.relpol.com.pl Export Sales Department phone +48 68 47 90 832, 951 • e-mail: [email protected]
Test buttons (no latching) and plugs
Test buttons (no latching) are recommended for R2N...WT, R3N...WT, R4N...WT, R15...WT 2 CO, R15...WT 3 CO
relays - for applications that do not allow permanent contact latching. By manual operation (pressing the button)
relay contacts can get switched for as long time as long the button is pressed. Contacts return to initial position as soon
as pressure is released from the button. Those operations can be done while the coil is deenergized.
Fig. 1 Fig. 2
Plugs R4W-0003 or R15-M203 can substitute button type T if manual operation (latching and testing) is not
allowed. Changing button type T for plug can be done by Customer themselves in the same way as changing button
type T for button (no latching).
10