Masoneilan SVI3 Digital Valve Positioner Fact Sheet English

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Masoneilan a Baker Hughes business

SVI ™

Digital Valve Positioner


Accurate, Responsive and Reliable
Optimize Service
The third generation Baker Hughes Data driven valve maintenance via new
Masoneilan™ SVI is a user friendly digital Online Valve Diagnostics with up to 1 year
valve positioner for pneumatic control of data storage.

valves. Utilizing advanced control and Improve Reliability


diagnostic algorithms, along with field- Built on 20+ years of proven technologies
proven non-contact position sensing like non-contact magnetic position sensing.
technology, the SVI delivers accurate,
responsive, and reliable positioning Increase Efficiency
Simple, easy to use, modular platform
performance. featuring 1-button SMARTCAL setup and
universal mounting.

Reduce Emissions
Low Bleed Pneumatics reduce air
consumption by 40%(1) while maintaining
best in class control and response.
(1) As compared to conventional positioners.

valves.bakerhughes.com
Benefits
Reliable and Accurate:
• Built on 20+ years of field proven valve position
sensing technology, control algorithms, and
advanced performance pneumatic design

Increase Plant Efficiency:


• Intelligent troubleshooting using embedded Key
Performance Indicators (KPIs)
• Cloning capability for on-demand hot swapping
• One device for all environments and applications
enabling reduction of spares inventory
• Low bleed pneumatics

Simple and Easy to use:


• Automated, single button commissioning
• Local user interface providing full configuration
capabilities - no additional tools/handheld
required
• Integrates with all leading control systems and
asset management software systems
• Easy field upgrades enabled by new modular
architecture and digital upgrades
• Integrated Input/Output – no additional bolt on
accessories required

Features
• Smart Cal - One button setup & calibration
• User Interface with high contrast graphical display
and pushbuttons, rated for operation in Hazardous
Areas
• NAMUR NE 107 alerts
• Universal design for linear and rotary valve
applications
• Robust, non-contact, shielded magnetic-type travel
sensor
• Industrial metal housing with corrosion resistant
Stainless Steel or Aluminum options
• Encapsulated and coated electronics
• Integrated diagnostics: Cycle counts, Step Tests, Ramp
Tests, Signatures, as well as system health indicators
• On board valve position feedback and limit switches
• Stainless steel mounting brackets for any valve
actuator combination, fully backwards compatible to
SVI II AP / SVi1000 brackets
• Explosion-proof AND Intrinsically Safe universal
labeled, with US, Canada, ATEX, and IEC approvals
(various regional country approvals available)
• HART® 7 communication compliant
• Fully collectable actuator exhaust and positioner vent
Specifications
Housing: EMC Conformity Standards:
• Case/Cover: Chromated Copper Free(1) aluminum, ASTM • Meets IEC/EN61326-1 Edition 2
A360; Optional 316L Stainless Steel • Emission: CISPR11 Class A
• Paint: Grey polyurethane with epoxy primer • Immunity: IEC/EN61000-4-2, 3, 4, 5, 6, 8
• Protection: IP66 and NEMA 4X • EMC 2014/30/EU Directive
Note: (1) Per API RP 14F
Performance (2)per ISA S75.13:
Weight:
• Accuracy +/- 0.5 percent Full span
• Aluminum - 3.3kg (7.4lbs)
• Hysteresis + DeadBand +/- 0.3 percent Full span
• Stainless Steel - 6.26kg (13.8lbs)
• Repeatability +/- 0.3 percent Full span
Materials: • Power-Up with position control <150ms
• I/P Motor and Relay - composite polymers and stainless • Power Interruption without reset <100ms
steel (300 & 400 series) Note: (2) For linear characteristic
• Mounting Kit - stainless steel (300 series)
Actuator capabilities:
Input Power and Signal:
Non-contact shielded magnetic travel sensor capable of:
• Min/Max current: 3.2mA / 22mA • Linear Motion: 0.25” to 8” (6.4 to 200 mm)
• Required Compliance voltage: 9Vdc at 20mA, 11Vdc at 4mA • Rotary Motion: 18° to 140°
• Termination: Screw-type terminals • Travel Sensor Resolution: 0.0125% (Typical - Rotary)
• Electrical Entries: Two 1/2NPT female
Pneumatics (Single-acting only)
Optional Input/Output Signals:
• Dry, oil-free air or sweet natural gas - regulated and filtered
• Two Configurable solid state switches: • Air supply pressure: 1.4 to 8.3 bar max (20 to 120 psi max)
- 1A – 30Vdc, self protected • Optional Exhaust routing manifold for 100% collection
- Normally Open or Normally Closed (when powered)
Air delivery:
• One 4 to 20 mA Output - Position Retransmit
• One Configurable Digital Input • 410 SLPM (14.5 SCFM) @ 30psi
• One Masoneilan Remote Position Sensor Input : 1k Ohm Air capacity:
• One 1-5V Remote Position Sensor Input
• Loading Cv = 0.66
Communication, Setup and Calibration: • Venting Cv - 0.51
• HART® Protocol, Rev 7 Steady State Air Consumption:
• Integrates with leading DCSs with full DTM and EDD support, • 2.8 SLPM (5.9 SCFH) @ 30psi
including, but not limited to:
• 3.4 SLPM (7.2 SCFH) @ 45psi
• Emerson DeltaV / AMS
• Honeywell / FDM Advanced Diagnostics:
• Yokogawa / PRM Online:
• Optional local user interface with graphical LCD and • Travel odometer, Cycles, Time Closed/Open, Time Near
keypad, approved for use in hazardous areas Closed, Alarms
Offline:
• Smart Cal one button calibration including Stops, Air-
action, Autotuning and Pre-determined Tuning sets • Ramp Test: Hysteresis, Deadband, Accuracy, Linearity
• Step Test: Overshoot, Response resolution, Deadtime
Ambient Temperature and Humidity Limits: • Valve Signature: Spring Range, Friction, Seat Profile
• Standard Temperature, -40°C to 85°C
(-40°F to 185°F), Nitrile Diaphragms Online Valve Diagnostics:
• Optional Extreme Temperature, -55°C to 85°C Online:
(-67°F to 185°F), Flourosilicone Diaphragms • Friction, Stick Slip, Spring Range, Error Offset, RMS Error,
• Sensors (pressure, temp, hall, current) factory calibrated Obstruction Detection, Calibration Error, and Setpoint
across full temperature range cycling tests

• 100% RH non-condensing Hazardous Area Certifications:

Tropical environmental compatibility ATEX, IECEx, US, and Canada approvals for:
• Flameproof / Explosion-proof
• Fungus resistance per ASTM-G21
• Intrinsic Safety
• Exposed circuits covered with anti-fungal coating
• Dust Ignition Proof
• Positively pressured housing with insect-resistant vents
• Increased Safety (e)

Note: See manual for a complete listing of all available


certifications and marking codes
SVI3
Model* SVI3- Smart Valve Interface - 3rd Generation

Diagnostics
a 2. Advanced Diagnostics
3. Online Valve Diagnostics

Pneumatic Train / Capacity / Fault State


b 1. Single Acting, Standard Flow (Cv >=0.5), De-energize on fault (Fail Safe)

Instrument Air / Temperature


c 1. Compressed Air or Natural Gas, Standard Temperature (-40°C to 85°C), Nitrile Diaphragms
2. Compressed Air Only, Extreme Temperature (-55°C to 85°C), Silicone Diaphragms
f

Construction / Display
1. Aluminum / No Display
d 2. Aluminum / Display with local interface
3. Stainless Steel / No Display
4. Stainless Steel / Display with local interface

Communication
e 1. 4-20mA - HART® Communication Protocol

Input/Output Options
1. None
2. 4-20mA Analog Output (Position Retransmit) Quantity (1)
f Configurable Switched Outputs Quantity (2)
Configurable Switched Input Quantity (1)
1-5V Remote Position Sensor Input (1)
Masoneilan Remote Position Sensor(RPS) Input (1)

Agency Approvals
g 0. None
1. Hazardous Area Unilable (ATEX, IECEx, US, Canada, UKEX,
UAE)

0. None

h
1. India (CCOE)
2. China (CCC), Taiwan (TS)
3. Russia (CU-TR) Azerbaijan (AZS), Uzbekistan
(GOST-U)
4. Brazil (INMETRO)
5. Japan (JIS)
6. South Africa (IA)
7. Ukraine (UATR)
8. Korea (KOSHA)

2 1 1 1 1 1 0 0 8
3 2 2 2 1
SVI3- 3
4

Example: SVI3-31111210
* Some models & options are mutually exclusive. Consult your local Masoneilan Authorized representative for a complete list of available models.

valves.bakerhughes.com
Copyright 2022 Baker Hughes Company. All rights reserved.

BHMN-SVI3-FS-33486D-1122 11/2022