Sid ST 10039004 A Us Lores
Sid ST 10039004 A Us Lores
Sid ST 10039004 A Us Lores
VersiCharge AC ™
Contact Information
1-800-333-7421
usa.siemens.com/versicharge
FCC Compliance
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protections against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, this is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Connect the equipment to an outlet on a circuit different from that to which the
receiver is connected.
Changes or modifications not expressly approved by the party responsible for compliance may void the
user’s authority to operate the equipment and the warranty on the product.
Other Information
Product information is subject to change without notice. All trademarks are recognized as the property of
their respective owners.
For Siemens VersiCharge™ Warranty Terms and Conditions, see the Warranty section of this manual.
4
VersiCharge™ AC Electric vehicle charging station
Index
1 Safety Information 7
1.7 Definitions 10
2 Mounting Instructions 11
3.4 SIM Card Installation – If Not Factory-installed (Commercial Parent Units Only) 22
5 Application Set UP 31
6 Configure/Commission VersiCharge Using the Configurator Tool (Use to Configure Multiple Chargers) 35
7 HMI 36
8 Operating VersiCharge 38
5
VersiCharge™ AC Electric vehicle charging station
9 Maintenance 44
10 Warranty 45
11 Help! 47
Technical Data 48
Figures
Figure 1. Align Mounting Bracket And Screw Into The Stud 12
6
VersiCharge™ AC Electric vehicle charging station
SECTION 1
Safety Information
1.1 Read this First
This manual contains instructions for use during installation, operation, and maintenance of the Siemens VersiCharge™ electric
vehicle charging station.
To reduce the risk of electrical shock, and to ensure the safe installation and operation of the Siemens VersiCharge, the following
safety symbols appear throughout this document to indicate dangerous conditions and important safety instructions.
DANGER Hazardous voltage. Will cause death or serious injury. Turn off Power before working
on this equipment. This indicates a situation where the present voltage can cause injury or
death. Extreme caution is required when servicing or installing the equipment referenced.
DANGER Explosion hazard. This equipment has arcing or sparking parts that should not be
exposed to flammable vapors. Use extreme caution and follow instructions carefully.
WARNING! This indicates a situation where failure to follow instructions may be a safety hazard or
cause equipment malfunction. Use extreme caution and follow instructions carefully.
NOTE: This indicates important information for optimal system operation. Follow instructions closely.
DANGER Hazardous voltage. Will cause death or serious injury. Turn off power to this
equipment before working inside.
• Read this Installation and Operations Manual in its entirety prior to installing, maintaining, servicing, or replacing a Siemens
VersiCharge EV Charging System.
• Permits: Be aware that many areas require special permits and/or utility approvals to install EV charging equipment.
Contact your local electrical inspector’s office and your local utility prior to beginning work to understand local requirements.
• Qualified electrician: Because of the inherent dangers of electricity, only a qualified electrician should install, maintain, service,
or replace electrical wiring and connected equipment. For the purpose of this manual, a qualified electrician is someone who is
familiar with equipment hazards of installation, construction, and operation. In addition, this electrician should meet the definition
of a qualified electrician pursuant to the National Electrical Code® (NEC®). Failure to comply with this recommendation may void the
VersiCharge warranty.
• Weatherproof seals: All VersiCharge units are qualified for outdoor use.
7
VersiCharge™ AC Electric vehicle charging station
WARNING! Failure to properly seat seals can result in water, debris and other foreign objects entering
the VersiCharge. These can damage electrical components and prevent proper functioning.
WARNING! When using electric products, basic precautions should always be followed. This manual
contains important instructions for units supplied with and without a NEMA 6-50 plug that shall be
followed during installation, operation, and maintenance of the unit.
• Failure to follow these instructions may lead to death, serious injury or property damage.
• Any electrical wiring required to install this VersiCharge shall conform to applicable codes and standards
(ANSI/NFPA 70). A qualified electrician should perform any wiring, maintenance or service.
• To reduce the risk of electric shock, never service, install, or uninstall this VersiCharge from service while
power is flowing to the unit.
• This equipment has arcing or sparking parts that should not be exposed to flammable vapors. This equipment should
be located at least 18 inches above the floor.
• Do not use this product if the flexible power cord or EV cable is frayed, has broken insulation, or any other signs of damage.
• Do not use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage.
• A torque driver shall be used to make power connections to ensure that adequate contact pressure is applied.
See the installation section of this manual for additional details.
• When a VersiCharge is hardwired during installation, power connections shall be made at line terminals with 14.5 in-lb.
torque driver.
• A VersiCharge charging station includes wire connector instructions for field installed wiring. Instructions included in this
manual must be followed to ensure proper installation.
• An insulated grounding conductor that is identical in size, insulation material, and thickness to the grounded and ungrounded
branch-circuit supply conductors, except that it is green with or without one or more yellow stripes, shall be installed as part of the
branch circuit that supplies the VersiCharge or system.
• The grounding conductor shall be grounded to earth at the service equipment or, when supplied by a separately derived
system, at the supply transformer.
• Do not attempt to operate this VersiCharge, if the ambient temperature is greater than 50°C(122°F)
• #6 90°C copper wire should be used for 48 A charger and #8 90°C copper wire should be used for a 40A charger.
NOTE: 1. Wire must have a temperature rating of 90°C or higher. 2. Do not set the amp switch higher than 40A (amp switch setting
#4) unless hardwired to a dedicated 60A branch protection circuit breaker (48A units should be set to amp switch setting #5).
8
VersiCharge™ AC Electric vehicle charging station
• CAUTION: To reduce the risk of fire, connect only to a circuit provided with 50/60 amperes maximum branch circuit
overcurrent protection in accordance with the ANSI/NFPA 70 National Electrical Code™.
• This VersiCharge has been designated to meet the requirements in section 626 of the National Electric Code (NEC®).
• UL Listing with Listing Number – Siemens VersiCharge devices are listed in UL file # E348556.
• Complies with the following UL Standards: UL 1998, UL 991, UL2594/CSA C22.2 No.280/NMX-J-677-ANCE, UL 2231-1/CSA
C22.2 No.281.1/NMX-J-668-1, UL 2231-2/CSA C22.2 No.281.2/NMX-J-668/2-ANCE, UL 2251/CSA C22.2 No.282/NMX-J-678-ANCE.
• This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the
following measures:
-
Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
• Personal Protection Equipment: Use of proper personal protection equipment, including, but not limited to, eye protection, shock
protection, gloves, and other appropriate protection, is recommended when installing or servicing any electrical equipment.
• Charging Circuit Interrupting Device (CCID): The Siemens VersiCharge line of EV Charging Systems includes a Charging Circuit
Interrupting Device (CCID). The CCID is required by UL Standard 2231 and is designed to detect ground faults within the
system and disconnect power from the downstream conductors, when a fault is detected.
DANGER Explosion hazard. This equipment has arcing or sparking parts that should not be
exposed to flammable vapors. This equipment should be installed at least 18 inches above floor
or ground level. Use extreme caution and follow instructions carefully.
• Arcing component in contactor: Siemens VersiCharge EV Charging Systems include a contactor that, when opened or closed, will
cause a short duration arc. The contactor is enclosed in an appropriate electrical enclosure but, if an arc occurs in the presence
of flammable vapors, the vapors could ignite, creating an explosion. Store flammable vapors away from all electrical equipment
and, should vapors be present, allow sufficient time for ventilation before operating this equipment.
The following symbols appear on the product label and are described here:
This label indicates the risk of hazardous voltage and electric shock which will cause death, serious injury, or substantial damage.
Turn off power supplying this VersiCharge before working inside.
9
VersiCharge™ AC Electric vehicle charging station
Explosion hazard. This equipment has arcing or sparking parts that should not be exposed to
flammable vapors. Use extreme caution and follow instructions carefully.
1.7 Definitions
The term EV used in this manual refers to an electric vehicle. The term AC used in this manual refers to alternating current.
10
VersiCharge™ AC Electric vehicle charging station
SECTION 2
Mounting Instructions
(See also VersiCharge Quick Start Guide at usa.siemens.com/versicharge)
• 1 – VersiCharge (with optional NEMA 6-50 infrastructure plug for 40A Residential Units only)
• 1 – Mounting Bracket
• 1 – Cable Holster
• 1 – Ferrite Core NOTE: plug-supplied units (40A) will have the Ferrite core factory installed. Only units to be hardwired (48 A)
will install the Ferrite core.
• 1 – Multi-use Connector (This connector is used to connect both the ModBus and the External Remote Control Interface
Connector.) NOTE: Supplied with Commercial Units Only
• RFID Cards: 2 Admin Cards and 5 User cards (Supplied with Commercial Units Only)
• 1 – #8 x 2-1/2” Flat Head Drywall Screw (for securing the holster to the wall stud)
• 2 – Lag Screws, Hex Head screws, 1/4 x 2” (for securing the mounting bracket to the wall studs)
• 2 – #10-32 X 3/8”, Tamper Resistant, Pin-In Hex Socket Button Head Cap Screw (for securing the charger).
• Cordless Drill (Phillips Bit with extender)–include 1/8” drill bit for pilot holes.
• Stud Finder
• 240 V AC Voltmeter
• 40A charger requires a 2-pole, 240V, 50A circuit breaker. 48A charger requires a 2-pole, 240V, 60A circuit breaker.
• NEMA 6-50 Outlet (if not hardwiring charger) NOTE: Only used with the 40A residential charger.
• Flathead Screwdriver NOTE: if using the wallboard mounting (alternate mounting) for the charger, a Phillips head screwdriver
will also be needed.
• Tamper resistant 5/32” Hex Bit with ¼” Allen wrench (for securing the charger)
• If hardwiring charger – #6 AWG 90° C copper wire, 3 conductors – #6 AWG 90°C copper wire should be used for 48A charger and
#8 AWG 90° C copper wire should be used for a 40A charger.
NOTE: 1. Wire must have a temperature rating of 90°C or higher. 2. Do not set the amp switch higher than 40A unless hard
wired to a dedicated 60A circuit according to national and local codes.
2.1.3 Alternate Installation Equipment (screws and anchors are not included in the versicharge kit):
• 5 – #12 x 1-½ LG Phillips head Ø.375 head minimum, with 5 – #12 wall anchors (NOTE: wall anchors must be rated for 61 lbs.
for 1/2” dry wall ).
11
VersiCharge™ AC Electric vehicle charging station
NOTE: For installation, the mounting-bracket hinges will be pointing to the ceiling, and the flat side of the
bracket will be against the wall.
1. Locate a stud within the wall that can handle the 17+ lb. load of the VersiCharge.
2. Place the mounting bracket not more than 12” above a 240 V outlet; level the mounting bracket and drill the
center-top hole using a drill with an extender.
3. Mount the bracket using the top hole and the lag screws, DO NOT tighten all the way.
• For concrete cinder block walls, install appropriate anchors. If using an existing outlet, ensure that power cord
will reach to the outlet. Using a 7/16” socket, attach mounting bracket to the wall in compliance with all National
Electrical Code® (NEC) and local jurisdiction requirements, using the 2 lag screws provided.
• For Siemens Post installation, see the post instruction manual at: (usa.siemens.com/versicharge)
12
VersiCharge™ AC Electric vehicle charging station
NOTE: For installation, the mounting-bracket hinges will be pointing to the ceiling, and the flat side of
the bracket will be against the wall.
NOTE: The VersiCharge can be mounted using 5 #12 x 1-½ LG Phillips head 0.375 head minimum with
5 #10 wall anchors
NOTE: Recommended - The 5 anchors must be at least 61lb. anchors rated for 1/2” dry wall.
(SCREWS AND ANCHORS NOT INCLUDED IN KIT.)
1. Locate the mounting bracket not more than 12” above a 240 V outlet or if hardwiring, the wiring will come
through the bottom of the charger.
2. Level the mounting bracket and drill 4 holes, one in each corner of the bracket.
3. Place anchors into the wallboard until they are flush with the wall.
4. Place the mounting bracket over the holes (hinges facing upward, flat side of the bracket against the wall)
with the anchors and screw the mounting to the wall securely.
5. Add a fifth hole for mounting the holster once the unit is mounted on the wall. Place the holster on the wall
and mark the correct position for the hole. Refer to Section 2.5 and its graphic.
13
VersiCharge™ AC Electric vehicle charging station
NOTE: For installation, the mounting-bracket hinges will be pointing to the ceiling, and the flat side of the bracket
will be against the wall.
4. Secure the enclosure with the locking mechanism after installing the holster and plug the VersiCharge
into the 240 V outlet.
14
VersiCharge™ AC Electric vehicle charging station
Threaded insert
3rd Security Screw
- Factory Installed
15
VersiCharge™ AC Electric vehicle charging station
1. Secure Charger to Mounting Bracket: Using the kit-supplied tamper-resistant screw– secure the charger cover with one screw
on the side.
2. Install Holster to Charger: Align Holster with guides in charger and drill pilot hole. Using the kit-supplied tamper-resistant screw,
use the third screw to secure the holster to the charger (hole at the top of the holster)
3. Standard installation (Figure 5) – Drill pilot holes and use the kit-supplied lag screw, #8 x 2-1/2” drywall screw, to secure the
holster to the wall stud.
4. Alternate installation (Figure 2, Section 2.3) – Drill pilot hole and use the fifth wallboard screw with anchor, screw into the wall.
1. Turn the power on; the white Power Available light should illuminate. If it does not, verify that the outlet or wire is
putting out 240 or 208 V using the voltmeter.
2. With the Power Available light on, plug the Electric Vehicle Supply Equipment (EVSE) cable into the car. If you have any
fault lights, please see the LED Light Display table in Section 8.1.
Siemens VersiCharge Mobile App (Best used when only one charger is configured to one account): Download the VersiCharge
mobile app to your smartphone to get started using your charger. Find these applications at either Google Play (https://play.
google.com/store), or iOS stores (https://www.apple.com/ios/app-store/).
Siemens Configuration Tool (Best used when configuring multiple chargers per account): Download the VersiCharge
Configuration Tool (PC App) at usa.siemens.com/versicharge. Unzip the tool to a PC and install by following the screens. This tool
will allow charger management from a PC.
WARNING! Do not force the connector into the receiver on the vehicle. If the connection
between the receiver and connector shows any resistance, inspect the pins in each and, if
damage is found, call a qualified service person.
16
VersiCharge™ AC Electric vehicle charging station
SECTION 3
DANGER Hazardous voltage. Will cause death, serious injury or substantial property damage.
Turn off power supplying equipment before working inside the unit.
DANGER! Any time the interior wiring is exposed while there is power to the unit there is danger of
hazardous voltage and serious injury.
NOTE: Any electrical wiring required to install this VersiCharge shall conform to applicable codes and standards (ANSI/
NFPA 70). A qualified electrician is recommended to perform these tasks.
NOTE: Please consider your planned installation location for the mounting bracket when choosing the location to which
you will run the wire.
NOTE: Electrical outlets must be installed in accordance with appropriate NEC and AHJ requirements. Please note that the
receptacle orientation required for proper installation of the VersiCharge product is per the illustration below.
1. A qualified electrician should install the outlet with the ground facing down (only the 40A charger is available
with a plug, the 48A charger MUST be hardwired). See Section 2.2, Figure 1, for outlet positioning.
Ground
facing down
Orientation Detail
WARNING! When installed outdoors, cord-and-plug installations require a NEMA outdoor rated receptacle
and enclosure due to the risk of moisture. Installing outdoors without properly rated outdoor receptacles
and enclosures will void the VersiCharge warranty.
3.1.1 Removing the Cord-and-Plug Assembly for Hardwiring (Only for the plug-supplied 40A Units)
Plug removal is only for the plug-supplied 40A units; 48A Units must be hardwired, see steps 6-13 below for hardwiring instructions.
NOTE: The rating of the circuit breaker that will be required is based on the ampere rating of the EVSE; 40A requires
50A breaker, 48A requires 60A breaker.
17
VersiCharge™ AC Electric vehicle charging station
NOTE: This enclosure has not been evaluated for rigid metallic and rigid non-metallic conduit. In order to maintain a Type
4 UL50E environmental rating, a hardwired installation should use liquid-tight flexible conduit only, with conduit glands
rated UL Type 4, 4X, 6 or 6P.
1. VersiCharge will need to be mounted on the bracket to hardwire the device. Open hinged cover by loosening four cover
Phillips screws.
3. Disconnect the attachment plug wires from the terminal block by loosening screws in positions 1, 2, and 3 and
remove the Ferrite core (the core will be reinstalled when hardwired).
4. Do not adjust the two lugs of the pre-installed wiring. These are for factory use only.
6. Route conductors into the VersiCharge from the conductor opening with proper strain relief.
8. Slide the Ferrite core over the black and red wires ONLY, and into position per Figure 8 (the green wire/ground
should not be placed through the Ferrite core).
9. Wire conductors (copper only) into VersiCharge (L1, L2 and Ground) from connected conduit. Using torque
screwdriver, torque all lugs to 14.5 lb.-in. See Appendix C for wire bending diagram.
18
VersiCharge™ AC Electric vehicle charging station
P1 - Black
Hot/Power
P2 - Green
Ground/Earth
P-3 - Red
Hot/Power
Ferrite Core
11. Replace barrier and secure with the two screws which were removed in the beginning.
12. Replace hinged cover, securing with four Phillips head screws. Swing the unit closed until the bracket clip
engages and secure the charger with the tamper-resistant security screws.
13. Turn the circuit breaker for this circuit to the ‘ON’ position.
DANGER Hazardous voltage. Will cause death, serious injury. Turn off power before working on
this equipment.
19
VersiCharge™ AC Electric vehicle charging station
The VersiCharge comes set to the maximum of the model purchased. For example, a 40 A model will come with the amp adjust-
ment switch set to 4, and a 48 A unit amp adjustment switch will be set to 5. Verify the required amp adjustment switch setting
based on the branch circuit protection (see the table below).
NOTE: The VersiCharge cannot control the power draw to the EV, it can only communicate the current capacity to the
VersiCharge to the EV.
NOTE: The Amperage Adjustment dial is for use by a qualified technician/electrician only.
• When changing the Amperage Adjustment dial, verify that the VersiCharge is disconnected from power.
Amperage Settings
• The purpose of the Amperage Adjustment dial is to set the maximum current that the EV is allowed to
draw from the charging stations.
• The dial has 10 settings.
• Settings 0-5 are for amperage adjustments.
• Settings 6-9 are for factory use only. These settings will result in a bad switch fault if used.
• The circuit must be sized for the maximum ampere requirement. Do not derate breakers or conductors based on
amperage adjustment.
20
VersiCharge™ AC Electric vehicle charging station
WARNING! Remote Control Interface should be low-voltage, control wiring (22AWG (.64mm)).
Installing higher voltage on this interface can cause damage to unit, preventing it from functioning
properly. Do not hook up 120/240 V to these connections.
The Siemens VersiCharge has a Remote Control Interface that allows charging to be controlled by an external device by wiring a
remote control interface to pins #7 and #9. Examples include demand response switches, building automation systems, digital
sensors, etc.
1. Remove the Multi-use Connector from the bag and wire an additional remote control interface cable to pins
#7 and #9.
NOTE: The Remote Control Interface cable is not supplied as part of the in-box equipment.
21
VersiCharge™ AC Electric vehicle charging station
NOTE: Do not press the cable with the connector attached through this gland, that will cause the loss
of the NEMA 4 rating.
6. Attach the Remote Control cable connector and attach the two cable connectors.
7. Gently tuck the cables into the back of the unit and close the case.
NOTE: The status output is a switch that indicates charging status. When the contacts are closed, the
unit is in charging state.
Explosion hazard. This equipment has arcing or sparking parts that should not be exposed to
flammable vapors. This equipment should be installed at least 18 inches above the floor or ground
level. Use extreme caution and follow instructions carefully.
3.4 SIM Card Installation – If Not Factory-installed (Commercial Parent Units Only)
This hardware uses a micro SIM card, but with an adapter will allow nano SIM cards.
The SIM card should NOT require a PIN. Locked SIM cards are not supported by VersiCharge hardware.
The following carriers are supported : USA: AT&T, T-Mobile, and Canada: Rogers, Telus. Data plans should have a minimum
consumption of 250 MB per month per charger.
22
VersiCharge™ AC Electric vehicle charging station
1. Expose the area holding the SIM card hardware by unlatching the cover. The SIM card sits next to the
Ethernet connection (see Figure 11 SIM card installation).
3. The SIM card socket is spring loaded. Slide the SIM card from the bottom upward into the slot until it stays in
place. To remove/replace the SIM card, press the SIM card upward and it will “spring” down and out of the slot.
There is an Ethernet port standard on the VersiCharge controller module 10/100BASE-T port with an RJ45 modular connector.
The Ethernet port is capable of data rates up to 100 Mbps and supports ModBus/TCP protocol. The Ethernet can be used to
commission/configure chargers and monitor charger activity on a daily basis (download the VersiCharge Configurator Tool
(PC application) at usa.siemens.com/versicharge).
NOTE: The Ethernet cable connector should NOT be attached to the Ethernet cable when it is pushed
through the rubberized Ethernet gland. This gland will not self-seal if the Ethernet connector is pushed
through the rubberized Ethernet gland and the NEMA 4 rating will be lost.
4. Insert the RJ45 plug from the bottom up into the Ethernet port.
23
VersiCharge™ AC Electric vehicle charging station
Using the ModBus RTU protocol. VersiCharge chargers can act as ModBus Child devices making any real-time data available
through the ModBus RTU protocol. ModBus Parent devices connected to the charger can access (read) this data or write data to the
charger’s registers, initiating control actions.
NOTE: Push the RS-485 wire through the Rubberized Cable Gland and then terminate the wires into the Multi-Use
connector terminal block. This gland will not self-seal if the connector is pushed through the rubberized cable
gland and the NEMA 4 rating will be lost.
1. Push the external ModBus RTU cable through the rubberized cable gland at the back of the charger (this will self-seal).
2. Attach the external ModBus cable wires to the internal (supplied) Multi-Use connector.
24
VersiCharge™ AC Electric vehicle charging station
3. Gently tuck the wiring into the space and secure the back of the charger.
Security Note: The ModBus RTU is an open protocol, and it is the responsibility of the installer to ensure
the security of the wiring of these connections to prevent tampering.
1. SW3-1 (left side) labelled RS485 is the Termination switch. This switch should be in the ON position for the Parent unit or
in the OFF position for a Child unit, unless that Child is the last Child in the daisy chain, then it must be ON.
1. SW3-2 (right side) labelled RS485 Term is the Termination switch. For the Child units the Termination switch
must be set to OFF, unless the unit is the last one in the daisy chain, then the switch must be set to ON.
25
VersiCharge™ AC Electric vehicle charging station
Devices connected on the Modbus RS-485 wire, including the Child, converter(s) and other instrumentation, must be wired as follows:
• Connect the shield of each cable segment to ground at one end only.
• Install a ¼ Watt termination resistor (RT) between the (+) and (-) terminals of the device at each end point of a
straight-line bus. The resistor should match the nominal impedance of the RS-485 cable, which is typically 120
ohms (consult the manufacturer’s documentation for the cable’s impedance value).
Any device connection that causes a branch in the main RS-485 ModBus cable should be avoided. This includes star and tee (T)
methods. These wiring methods cause signal reflections that may result in interference. No more than two cables should be
connected at any connection point on the RS-485 ModBus daisy chain. This includes connection points on instruments, converters,
and terminal strips. Following these guidelines ensures that both star and tee connections are avoided.
26
VersiCharge™ AC Electric vehicle charging station
c. Connect by selecting serial port used to connect to EVSE using USB to RS485 adapter (PN: USPTL4-LS or similar)
d. The following connection set-up should be used. Click OK after set-up is complete.
i. Baudrate = 38400
iii. Databits = 8
iv. Stopbit = 1
27
VersiCharge™ AC Electric vehicle charging station
f. Read Operation: Enter the register to be read in the Address box, the number of registers to be read in Quantity box. Click OK
to read continuously the same value. If read only once is desired, then click on “Read/write once” tab. Also, in the last, there is
a display option. This will give an option to display the read value in different format.
g. Write Operation:
28
VersiCharge™ AC Electric vehicle charging station
29
VersiCharge™ AC Electric vehicle charging station
SECTION 4
RFID functionality is an available feature for commercial units only. Pass the RFID card in front of the RFID and, if successful, the
Charging Process Light will flash twice from the bottom up, there will be an audible tone. If the card swipe is not successful, the
Charging Process Lights will flash for one second, decreasing to .25 seconds; this will happen two times. There will be two audible
tones, decreasing if card swipe is unsuccessful.
RFID Swipe Successful Charging LED ON/Blinking. White #2, #4, #6 &
#8 every 1/4 second in incremental pattern
starting from 0.25S, 0.5S,0.75S and 1S. Repeat 2
times. Audible single beep tone.
RFID Swipe not successful Charging LED OFF. White #2, #4, #6 & #8 one
Second in decremented pattern starting from
1S, 0.75S,0.5S and 0.25 S. Repeat 2 times.
Audible dual beep tone.
RFID card management can be performed via the ModBus controller, OCPP-based server, or manually using Admin cards provided
with the unit - (Note: Admin cards may not be used when the unit is connected to an OCPP server and RFID cards must be managed
by the OCPP server through the "Local Auth List Management" profile.) Please refer to ModBus map to implement the appropriate
commands to add/remove or authorize charging sessions. VersiCharge maintains a local preauthorized list which holds the list of
all authorized user cards. An authorized user card in the preauthorized list, when tapped, will allow the charging session to start.
To add user cards to pre-approved, tap Admin card, followed by tapping user card(s) that are to be added to the preauthorized list.
Once all user cards are added, tap the Admin card to finish the operation of adding user cards to local preauthorized list. In order
to remove a user card from pre-approved, tap the Admin card followed by the user card already in the preauthorized list, then tap
Admin card again to end the removal process.
30
VersiCharge™ AC Electric vehicle charging station
SECTION 5
Application Set Up
Siemens is proud to offer industry-leading control and monitoring functionality built into the VersiCharge product.
1. Smartphone Application. This is the preferred method for VersiCharge residential charger owners when one charger is linked
with one user account. Search for "VersiCharge" in the App Store for the iOS operating system (for iPhone owners) or in the
Google Play Store for the Android operating system. Download the application.
2. PC Application. Using a PC, control and monitor with the VersiCharge Configuration Tool. The VersiCharge Configuration Tool
has been designed to allow commissioning of multiple chargers as well as the configuration of parent/child networks.
NOTE: In case of a Wi-Fi network failure, the charger will continue to function based upon the registered state. If the
schedule function is enabled, it will continue to run indefinitely. All demand response settings will be saved. User
interface functionality will remain the same.
• Install the VersiCharge Mobile Application from Google Play (https://play.google.com/store) Store or Apple App Store
https://www.apple.com/app-store/) (ensure you have an internet connection on your VersiCharge). The web app
(https://www.versichargesg.com) and smartphone app follow the same steps.
• Complete the steps (see below) and by creating the account you are accepting the Privacy Policy.
Create An Account: Select Create One Select Terms & Conditions or Privacy View Privacy Rights
Rights to view them.
31
VersiCharge™ AC Electric vehicle charging station
NOTE:
• Username: Minimum four characters and maximum of ten, must contain at least one letter, special characters
allowed: !, $, _, and –
• Password: Minimum of five characters with suggested maximum of 12 characters, avoid special characters (<, >, ”, ‘, and ~)
The following process links your VersiCharge to your chosen wireless network, enabling communication with the Siemens Cloud network.
• Follow steps 1 through 6 to link your charger to your account and manage your charger using the Mobile App.
NOTE: Residential 40A Unit Only - Before beginning to link the charger to an account, ensure the breaker powering
the dedicated branch circuit is ‘OFF’; plug in the VersiCharge. Turn breaker ‘ON’ after plugging the unit in.
• The Power Available LED will turn white and the Wi-Fi Status LED will go through the following process:
- Indicator should initially slowly blink red and then switch to slowly blinking yellow, then white.
- Once the indicator slowly blinks white the charger has transitioned to Access Point mode (AP) and is ready to be
connected to a Wi-Fi network.
• Once in AP mode, you may use your VersiCharge mobile app or your laptop to commission the VersiCharge to a
network with an open Internet connection to establish connection to the Siemens VersiCloud system for management
and to receive periodic charger updates.
32
VersiCharge™ AC Electric vehicle charging station
Software loading
Software running
Connecting to network
Connected to network
Connecting to VersiCloud
Sign in with email and password, select Select Add a Charger. Step 1 – Check the Wi-Fi Light – it
Sign In or create an account by selecting Add a charger is the landing page until should be blinking white.
“Create One”. a charger has been linked to your Select Next.
account.
33
VersiCharge™ AC Electric vehicle charging station
Step 2 – Select the charger with Step 3 – Choose a Network by clicking Step 4 – Enter Password for the
vs-xxxxxxxxxx. on the network. network. Note: Passwords are case
sensitive and network passwords
cannot contain special characters.
Step 5 – Wait for the charger to connect Select Done once the
with the Siemens Cloud. For information “Congratulations” screen
about the LED lights during commis- appears.
sioning, see the Wi-Fi LED Light Sequence
When Adding a Charger table under
section 5.2 above.
34
VersiCharge™ AC Electric vehicle charging station
SECTION 6
Configure/Commission VersiCharge
Using the Configurator Tool
(Use to Configure Multiple Chargers)
• Download the Configurator Tool from: usa.siemens.com/versicharge
• Unzip the Configuration Tool and install. Step through configuration of VersiCharge. Use the manual for any questions.
35
VersiCharge™ AC Electric vehicle charging station
SECTION 7
HMI
5 13 14 6
1 2 3 4
Figure 24. Residential HMI NOTE: Number of LEDs may change based on specific part number and features.
5 13 14 6
1 2 3 4
Figure 25. Commercial HMI NOTE: Number of LEDs may change based on specific part number and features.
36
VersiCharge™ AC Electric vehicle charging station
• The Power Available LED will turn white and the Wi-Fi Status LED will go through the following process:
- Indicator should initially slowly blink red and then switch to slowly blinking yellow, then white.
- Once the indicator slowly blinks white the charger has transitioned to AP and is ready to be connected to
a Wi-Fi network.
• Once in AP mode, you may use your VersiCharge mobile app or your laptop to commission the VersiCharge to a
network with an open internet connection to establish connection to the Siemens VersiCloud system for
management and to receive periodic charger updates.
37
VersiCharge™ AC Electric vehicle charging station
SECTION 8
Operating VersiCharge
8.1 LED Light Display
Lights up white
LED off
Vehicle connected
Lights up white
Charging in progress
Lights up white
After switch on, the charger will Connect PC or mobile device for commissioning, charger
go to Access Point mode is ready to be added to the account
Flashes white
No Wi-Fi Check the router
Lights up red
Charger is connected to router. Strengthen the Wi-Fi.
Weak Wi-Fi.
Lights up orange
38
VersiCharge™ AC Electric vehicle charging station
Lights up green
Attempting to connect to
VersiCloud
Flashes blue
Ready (with successful connection
and registration in VersiCloud)
Lights up white
Access blocked Unlock via RFID/ OCPP/MODBUS /Mobile App
Flashes white
4 h delay Wait until charging process starts.
Flashes white
6 h delay Wait until charging process starts.
Flashes white
8 h delay Wait until charging process starts.
Flashes white
Press Touch Sensitive Button to Press the Touch Sensitive button once for 2 hour delay,
add a time delay. twice for 4 hour delay, three times for 6 hour delay and
four times for 8 hour delay.
39
VersiCharge™ AC Electric vehicle charging station
A fault has occurred. The device is in a fault state. Eliminate the fault
and then push the touch button and hold for 5
seconds to reset.
Ground fault
A fault has occurred. Turn the supply voltage off and on again.
Flashes red
A fault has occurred. Error code: 001. Notify Technical Support.
Lights up red
Lights up red
A fault has occurred. Error code: 004. Notify Technical Support.
Lights up red
A fault has occurred. Error code: 005. Notify Technical Support.
Lights up red
40
VersiCharge™ AC Electric vehicle charging station
Lights up red
A fault has occurred. Error code: 007. Notify Technical Support.
Lights up red
A fault has occurred. Error code: 008. Notify Technical Support.
Lights up red
A fault has occurred. Error code: 009. Notify Technical Support.
Lights up red
A fault has occurred. Error code: 0010. Notify Technical Support.
Lights up red
Random delay between 1-5 minutes No Action.
on power cycle if EV is connected.
EVSE will resume charging after
delay expires
Cold Start - Lights up steady white.
41
VersiCharge™ AC Electric vehicle charging station
DANGER Risk of electric shock and fire. Touching live parts may cause electric shock or even
death. Defective connectors or cables may cause fire.
• Do not kink or squeeze the charging cable. Do not draw the charging cable over sharp edges or hot surfaces.
• Do not use the charging station if damage or tampering is visible. If damage is visible, Inform the operator. Until damage is
repaired, keep away from the charging station and do not attempt to charge an EV.
• Grip the power plug/connector to disconnect from the charging unit. Do not remove the connector by pulling on the cable.
Unauthorized accessories should not be used with the VersiCharge due to risk of fire and/or overheating.
• DO NOT use a charging cable that is not approved for the vehicle.
CAUTION! Risk of accident. Ensure that the charging cable does not block an exit or pose a
tripping hazard. Ensure the cable cannot be ripped out of the charging station.
• Using the charger connector, gently insert the connector into the EV. Be sure not to force the connection or bend any pins
in the connector.
• Check the charger "Lock" light (see Figure 25-commercial chargers only), when lit, the front panel is locked and will not
begin charging. Pass a User RFID card in front of the reader to unlock and begin charging. The "Lock" light will be off.
RFID authentication is successful when the Charging Process Light flashes twice from the bottom up, and there is an
audible tone. RFID authentication is not successful when there are two audible tones.
• If delay is needed, press the Touch Sensitive button once for 2 hour delay, twice for 4 hour delay, 3 times for 6 hour delay
and four times for 8 hour delay. Once the delay is selected, charging will begin automatically after the delay countdown.
NOTE: The delay function is not supported using the Touch Sensitive button if the charger is configured for OCPP
communication, or if RFID is enabled.
42
VersiCharge™ AC Electric vehicle charging station
Press 1x for 2 Hr. Delay Press 2x for 4 Hr. Delay Press 3x for 6 Hr. Delay Press 4x for 8 Hr. Delay
NOTE: The LED bar display indicates that current is flowing to the vehicle and the vehicle battery is charging. The LED bar
display is off in the following cases:
•
The vehicle is not drawing power.
– The charging unit pauses, for example, because of load management
– The vehicle pauses the charging
• Charging completed.
• Once charging is completed, the “Ready” status light turns off:
• Carefully remove the connector from EV and stow the cable in the cable holster to prevent damage to
either the cable or connector.
Vehicle connected. LED lights up white. Charging in progress. LED lights up white. Charging completed.
Charger is ready. LED lights are off.
After successful authorization, charging will begin automatically unless a delay has been set.
NOTE: The communication connection to the vehicle is established. This process may take some time depending on the connec-
tion speed and response speed of the backend (e.g. VersiCloud) and vehicle.
43
VersiCharge™ AC Electric vehicle charging station
SECTION 9
Maintenance
While there is no maintenance for the internal works of the VersiCharge, the exterior does require some basic,
common sense maintenance. The following maintenance can be performed by the owner/user. All other service
must be conducted by qualified personnel.
General exterior maintenance is recommended to be performed every six months depending on the
environment. In harsh environments, maintenance should be performed more often.
Regular cleaning is recommended to avoid accumulation of debris/dust/dirt on or around the unit. Wipe
surfaces with a soft cloth dampened with water, or for harder to remove marks, use an alcohol based cleaner.
Do not spray with high pressure cleaning hoses or use abrasive chemicals.
Check for cuts, damage, and debris. If debris is present, remove it. If you find damage, contact your supplier.
Check the HMI for damage/signs of faded color that is clearly visible.
Ensure there is no debris or damage inside or around the cable, cable holder and connector/plug. If present,
remove debris and/or notify the supplier of any damage. Check the connector/plug pins for any signs of
corrosion and contact the supplier, if there is any damage to the pins.
Check for snow buildup around the VersiCharge and clear the area around the VersiCharge. This should be
checked daily in areas with high snowfall.
44
VersiCharge™ AC Electric vehicle charging station
SECTION 10
Warranty
10.1 Limited Warranty
Siemens Industry Inc., Future Grid, EMobility (“Siemens”) has developed a highly reliable EV Supply Equipment
(EVSE), branded as VersiCharge ("VersiCharge EVSE"), that is designed to withstand normal operating conditions
when used in compliance with the Siemens Installation and Operations Manual supplied with system as originally
shipped by Siemens. The Siemens limited warranty ("Limited Warranty") covers defects in workmanship and
materials of the VersiCharge EVSE ("Defective Product") for a period of three (3) years (the “Warranty Period”) from
the date of registration of such VersiCharge EVSE via the registration portal (usa.siemens.com/versicharge ). The
VersiCharge EVSE must be registered within 90 days of purchase to activate the warranty policy including the
Siemens Care package.
The Limited Warranty does not apply to, and Siemens will not be responsible for, any defect in or damage to any
Siemens VersiCharge EVSE: (1) that has been misused, neglected, tampered with, altered, or otherwise damaged,
either internally or externally; (2) that has been improperly installed, operated, handled or used, including use
under conditions for which the product was not designed, use in an unsuitable environment, or use in a manner
contrary to the Siemens Installation and Operations Manual or applicable laws or regulations; (3) that has been
subjected to fire, water, generalized corrosion, biological infestations, acts of God, or input voltage that creates
operating conditions beyond the maximum or minimum limits listed in the Siemens VersiCharge EVSE
specifications, including high input voltage from generators or lightning strikes; (4) that has been subjected to
incidental or consequential damage caused by defects of other components of the electrical system; or (5) if the
original identification markings (including trademark or serial number) of such VersiCharge EVSE have been
defaced, altered, or removed. The Limited Warranty does not cover costs related to the removal, installation or
troubleshooting of the customer’s electrical systems. Siemens’ aggregate liability under the Limited Warranty shall
not exceed the original cost of the Defective Product.
During the Warranty Period, Siemens will, at its option, repair or replace the non-compliant portion of the Defective
Product free of charge, provided that Siemens through inspection establishes the existence of a Defective Product
covered by the Limited Warranty. Siemens will, at its option, use new and/or reconditioned parts in repairing or
replacing the Defective Product.
Siemens reserves the right to use parts or products of original or improved design in the repair or replacement of
Defective Product. If the product has a Wi-Fi module and contains a defect due to the faulty Wi-Fi module, Siemens
may replace only the Wi-Fi module or the entire unit at its sole and absolute discretion. If Siemens repairs or
replaces a Defective Product, the Limited Warranty continues on the repaired or replacement product for the
remainder of the original Warranty Period or ninety (90) days from the date of Siemens’ return shipment of the
repaired or replacement product, whichever is later.
The Limited Warranty covers both parts and labor necessary to repair the non-compliant portion of the Defective
Product, but does not include labor costs related to un-installing the Defective Product or re-installing the repaired
or replacement product. The Limited Warranty also covers the costs of shipping Siemens VersiCharge EVSE’s to
Siemens (where Siemens has first issued a Return Merchandise Authorization / Return Goods Authorization
("RMA" / "RGA") number for such product) as well as repaired or replacement product from Siemens to customer,
via a non-expedited freight carrier selected by Siemens, to and from locations within the United States (including
Alaska and Hawaii) and Canada, but not to or from other locations outside the United States or Canada.
The Limited Warranty does not cover shipping damage or damage resulting from mishandling by the freight carrier.
Where customer seeks to remedy damages caused by the freight carrier, such claims must be pursued directly
against the freight carrier and not against Siemens. Siemens’ repair and replacement obligations under this Limited
Warranty are conditioned upon the customer’s strict compliance with the following policy and procedure:
45
VersiCharge™ AC Electric vehicle charging station
• All Defective Product must be returned with a RMA / RGA number which customer must request from
Siemens.
• All Defective Product authorized for return must be returned in the original shipping container or other
packaging that is equally protective of the product.
• The returned Defective Product must not have been disassembled or modified without the prior written
authorization of Siemens.
THE LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY SIEMENS AND, WHERE PERMITTED
BY LAW, IS MADE EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, STATUTORY OR OTHER-
WISE, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF TITLE, QUALITY, MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE OR NON-INFRINGEMENT OR WARRANTIES AS TO THE ACCURACY, SUFFICIENCY OR
SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN MANUALS OR OTHER DOCUMENTATION.
IN NO EVENT WILL SIEMENS BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL
DAMAGES, LOSSES, COSTS OR EXPENSES HOWEVER ARISING, WHETHER IN CONTRACT OR TORT, INCLUDING
WITHOUT LIMITATION ANY ECONOMIC LOSSES OF ANY KIND, ANY LOSS OR DAMAGE TO PROPERTY, OR ANY
PERSONAL INJURY AND SIEMENS’ AND ITS SUPPLIERS’ MAXIMUM LIABILITY UNDER THIS CONTRACT SHALL BE
THE ACTUAL PURCHASE PRICE RECEIVED BY SIEMENS FOR THE DEFECTIVE PRODUCT AT ISSUE, OR ONE MILLION
DOLLARS, WHICHEVER IS LESS. CUSTOMER AGREES THAT THE EXCLUSIONS AND LIMITATIONS SET FORTH IN THIS
SECTION SHALL GOVERN AND CONTROL OVER ANY OTHER REMEDIES TO WHICH CUSTOMER MAY OTHERWISE BE
ENTITLED AND SHALL BE GIVEN FULL FORCE AND EFFECT WHETHER OR NOT ANY OR ALL SUCH REMEDIES SHALL
BE DEEMED TO HAVE FAILED OF THEIR ESSENTIAL PURPOSE. THESE LIMITATIONS OF LIABILITY ARE EFFECTIVE,
EVEN IF SIEMENS HAS BEEN ADVISED BY THE CUSTOMER OF THE POSSIBILITY OF SUCH DAMAGES.
To the extent any implied warranties are required under applicable law to apply to the Siemens VersiCharge
EVSE, such implied warranties shall, to the extent permitted by applicable law, be limited in duration to the
Warranty Period. In states and provinces which do not allow limitations or exclusions on implied warranties or
on the duration of an implied warranty or on the limitation or exclusion of incidental or consequential
damages, the above limitation(s) or exclusion(s) may not apply. This Limited Warranty gives the customer
specific legal rights, which are the customer’s exclusive remedies hereunder. The customer may have other
rights that vary from state to state or province to province.
46
VersiCharge™ AC Electric vehicle charging station
SECTION 11
Help!
Call us any time, any day at: 1- 800-333-7421 or Email us at: [email protected]
47
VersiCharge™ AC Electric vehicle charging station
Data plans for chargers: Siemens offers chargers with data plans for customer convenience. See table below for data plans.
Description Catalog Number
AT&T 1 year data plan, 2GB capped monthly bandwidth (supports ONE Parent charger). P3R77992000784
AT&T 1 year data plan, 5GB capped monthly bandwidth (supports ONE parent charger and up to 9 P3R77992000800
commercial child chargers). This is a yearly fee that Siemens will bill direct after year one.
Extended Warranty per Level 2 charger - 1 additional year, No In/Out services US2:VCEXWAR1YR
Extended Warranty per Level 2 charger - 2 additional years, No In/Out services US2:VCEWAR2YR
48
VersiCharge™ AC Electric vehicle charging station
APPENDIX A
Useful Links
• Register the VersiCharge Hardware at: https://emobility.siemens.cloud/register/
• If you don’t have an existing account, before commissioning chargers, create an account in VersiCloud -use the following link
and click “Register” or use the Mobile App to create a new account: https://www.versichargesg.com/Account/Login?ReturnUrl=%2f
• Deregister a charger whose ownership has changed, or when it is moved to another network, by logging into the following link and
finding the charger and selecting "Deregister": https://www.versichargesg.com
• Download the Mobile App at the following links Recommended for Residential installations:
Android - https://play.google.com/store/apps/details?id=com.siemens.VersiChargeSG
iOS - https://apps.apple.com/us/app/versicharge/id989742892
• Download the VersiCharge Configuration Tool (PC application). Recommended for Commercial installations.
https://assets.new.siemens.com/siemens/assets/api/uuid:e2ab1265-3049-455f-bfc0-1a666b4b76f1/versichargeconfiguratorsetup1-1-2.zip
- Detailed VersiCharge Installation and Operating Manual, as well as all legal and warranty information.
- Open Source Report: Product Clearing report for 3rd party SW components
- Privacy Rights
49
VersiCharge™ AC Electric vehicle charging station
APPENDIX B
NOTE: The rating of the circuit breaker that will be required is based on the ampere rating of the EVSE; 40A requires 50A
breaker, 48A requires 60A breaker. Also, the wiring should not be exposed to any conditions that could potentially damage
wiring or cause a potential hazard.
50
VersiCharge™ AC Electric vehicle charging station
APPENDIX C
VersiCharge™
Power Wire Bending Diagram
Applicable to hardwired units only.
P1 - Black
Hot/Power
P2 - Green
Ground/Earth
P3 - White
Hot/Power
A full-size wire bending diagram is supplied in the box. Find that, place the cable (22AWG (.64mm)) being wired to the unit on
it and bend the wires to match the diagram. Insert the wires into the unit and tighten the connections (to 14.5 in-lbs.).
51
VersiCharge™ AC Electric vehicle charging station
Notes:
52
Legal Manufacturer This document contains a general description of available technical
Siemens Industry, Inc. options only, and its effectiveness will be subject to specific variables
3617 Parkway Ln. including field conditions and project parameters. Siemens does not
Peachtree Corners, GA 30092 make representations, warranties, or assurances as to the accuracy or
United States of America completeness of the content contained herein. Siemens reserves the
right to modify the technology and product specifications in its sole
Telephone: +1 (800) 333-7421
discretion without advance notice.
[email protected] or
[email protected]
Engineering No. R815071-R01
Article No. SIDS-T10039-00-4AUS