Keli D30-2 Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

D30-2

Electronic Weighing Indicator

User Manual

●Please read this manual carefully before using

●Please keep this manual properly for reference

1
Chapter 1 Technical parameters
1、Model: D30-2
2、Digital load cell interface:
Communication mode RS485
Digital interface ability 1~4 keli E type digital load cell with communication distance ≤30m
Transmission baud rate 19200 bps
Excitation power DC+12V
3、Display:
6 digits of 0.80 inch LED with red light, 6 digits of status symbols.3 battery capacity symbols
4、Serial communication interface
Transmission mode RS232
Transmission baud rate 600/1200/2400/4800/9600/19200(Option)
5、Operating temperature 0℃~40℃
Operating humidity:≤85%(RH)Non-condensing;
6、Storage temperature -10℃~60℃
Storage humidity:≤95%(RH)Non-condensing;
7、Dimension 240mm × 155mm × 155mm(L×W×H)
8、Weight 0.90kg

Chapter 2 Indicator Installation and Connection


2.1、The connection between indicator and digital load cell
The D30-2 indicator can connect the E type protocol digital load cell only and the connection diagram is
as below

2.2 connection between indicator & PC by RS232

2
Indicator PC 9 pin
PC interface
interface
2 2
3 3
5 5
INDICATOR TO PC INDICATOR TO PC BY RS232

2.3、The connection between indicator and storage battery


Battery charging function module installed in the internal indicator and battery requirement:
12V/7Ah

Chapter 3 Keys and indicator light operation guide


3.1、Keys and indicator light operation guide
8 Membrane keys:【Test/】,【Fun/】,【Accum/】,【Total Clear/】,【Cal】, 【adjust scale】
【Tare/Cancel】,【Zero/Enter】。
1. Composite keys instruction:
Key Description 1 Description 2
【Test /】 【Test】:Enter test interface 【】: Flicker bit value add 1
【Fun】: Enter parameter setting
【Fun /】 【】:Flicker bit value munus 1

【Accum】:Accumulate the current net 【】:Flicker bit shift one bit to left
【Accum /】
weight
【 Total Clear 】 : Clear current 【】:Flicker bit shift one bit to right
【Total Clear /】
accumulated weight
【Tare】: Indicator tare 【Cancel】:Return to weighing status
【Tare/Cancel】

【Zero】:Indicator return to Zero 【Enter】:Save the current weight


【Zero/Enter】
data
【CAL】 【CAL】:enter calibration interface
【Adjust scale】;enter adjusting scale
【Adjust scale】
interface
2. 7 bits status indicator light: Inner code, function, kg/lb, accumulation, net weight, stabilization, zero.
Indicating symbol Function description
(bright)
Inner code symbol Inner code display status

Function symbol Menu status


kg/lb symbol lb status
accumulation Accumulated status
symbol
stabilization stable status
symbol
3
net weight symbol net weight status

zero symbol zero status


3.2 Guideline for normal operation and function description
1、Start and start automatic zero
Indicator device has a 0~9 self checking with power on If zero point has deviation under the set zero
range, the indicator will zero automatically. If beyond the zero range, the current real weight value will be
displayed after” Err 01”.Pl see the calibration parameters for setting the zero range in the debugging manual.
2、Manual Zero
a、Under the status of gross weight and stabilization as well as within the manual zero range, press the key:
【Zero/Enter】,the indicator can make the return-to-zero;
b、Under the status of net weight with the started manual zero function, gross weight is within±5 division
value range, press the key: 【Zero/Enter】,the indicator can make the return-to-zero;
3、Tare
Tare operation can be made when gross weight over zero and stabilization status, press the key
【Tare/Cancel】,“0” is displayed in the indicator, tare weight is the current gross weight, and enter the “net
weight” display mode and the net weight indicating light is bright.
When gross weight is zero as well as under the ” net weight “display mode, press the key
【Tare/Cancel】,quit the net weight mode and the net weight indicating light is off.

4、 Accum, Total clear, Accumulation Print Operation


a、Under the condition of net weight value over the min weighing value(5 division value) and
stabilization status,press Key” Accum” and accumulate the current net weight, “Accum”
Indicating light bright and the total accumulated value displayed,2 seconds later with accumulating times “n
*”display and 3 seconds later with automatic quit the status of accumulation. Next operation shall be made
under the condition of net weight value less the min weighing value (5 division value), after power off
and start, the accumulation data not recorded.
b、Parameter “SET 5”can make inquiry, print the accum weight and times under the fixed format
c、Under weighing status, press 【Total clear/】 ,the “CLEAr 0”display on the indicator “CLEAr
0”. By using 【direction key】choose “1” means to confirm clearing the accumulation weight and times,choose
“0” means to confirm no clearing the accumulation weight and times.
5, computer communication
Computer can display weight, if communication wrong or overload, indicator will close computer
communication.

Chapter 4 Parameters setting

4.1 Communication parameters setting


several communication protocol available with optional baud rate as follows:
Step Operation Display Description
【Fn/】 SEt ** By【Direction key】choose 0, enter setting communication
1 【Direction key】 SEt 00 parameter interface.
【Zero/Enter】
【Direction key】 tF * Communication way(0~5), like 0, 0:close
【Zero/Enter】 tF 0 communication, 1~5: continuously sending way, for
2
details pls see attachment A. after setting, return
weighing display condition
bt **** Serial communication baud rate(0~5)
【Direction key】 bt 9600 0~5 refer separately: 600、1200、2400、4800、9600、
3
【Zero/Enter】 19200 baud rate
Eg: choose 4=9600
4
4.2 Unit setting
Two units available(KG,LB) and can make unit switchover, See the operation below:
Step Operation Display Description
【Fn/】 SEt ** By【Direction key】choose parameter 1, enter setting unit
1 【Direction key】 SEt 01 interface
【Zero/Enter】
【Direction key】 uint * Two units (KG,LB) can be set in the indicator
2 【Zero/Enter】 uint lb Note: KG is rated unit when start indicator, after setting,
return to weighing condition
5 End Finish setting and return to the weighing display status

4.3 Accumulated value query


Indicator accumulated value and times operation below:

Step Operation Display Description


【Fn/】 SEt ** By【Direction key】choose 2 enter accumulation interface
1 【Direction key】 SEt 02
【Zero/Enter】
2
******
【Zero/Enter】 Display current accumulated value
3
n * Display current accumulated times
【Zero/Enter】
4 END Return weighing status
Note: 1; the connection between indicator & load cell must be well, and load cell well grounded, don’t plug
out/in during indicator is power on/
2; static electricity protection, don’t welding or other high-current operation on the platform, under rainy
season, must be well-lighting-protection.

Chapter 5 Error tips


Err 01 Means:Not sufficient zero conditions 1、Boot over zero range;
2、Unstable zero;3、Over manual zero range;4、Zero under Tare condition
Err 02 Means:No sufficient Accum conditions。1、Accumulation value over display range;2、Unstable
accumulation;3、Accum under non-zero status;4、No accum when overload;5、Accum value less 5 division
value
Err 03 Means: Alarm overload and must unload all or part weights
Err 04 Means: No stabilization, no calibration
Err 05 Means: Increase calibration weights since the insufficient weight of the second calibrated load
pint
Err 06 Means: Not sufficient Tare conditions 1、Unstable Tare;2、Overload Tare;3、Tare with gross
weight less than 0
Err 08 Means: 1、No overload record under this condition;2、No Accum record
Err 16 Means: wrong password input
Err 17 Means: wrong parameter setting,pl refer the related parameter input range requirement;
Repetitive press a certain load cell when setting pressing corner position;
Ecc 01~04 Means:Number“ n” load cell error

Appendix A: Communication protocol


Serial data format set :8 data bits,1 stop bit,No parity bit;Continuous serial communication mode,
3kinds of Communication protocol format;Easy selection by TF parameter.
(1). Serial mode (TF=1): (compatible A9)
Transmission data is the real current weight data(gross weight) by indicator(overload weight data:
999999)。every frame is composed of 12 groups data with format below:
No X byte Remark Eg ( sending+20.00 )
Content
content code content Hex code
1 Start (XON) 02 XON 02
5
2 +Or- symbol bit 2B/2D + 2B
3 top bit 30~39 0 30
4 30~39 0 30
5 30~39 2 32
Weight data
6 30~39 0 30
7 30~39 0 30
8 bottom bit 30~39 0 30
9 Decimal bit right to left(0~4) 30~34 2 32
10 top 4 bits XOR 31
11 XOR parit bottom 4 bits check= 3b
0x1B
12 End X0FF 03 XOFF 03
XOR =2⊕3⊕……8⊕9。
(2). Serial mode (TF=2):(compatible D2+)
All data are ASCII code,every frame is composed with 9-byte(included decimal point), data is sent from
bottom to top bit, every frame has a separation symbol “=” , sending current weight data, eg current data is
188.5, serial sending 5.88100=5.881000=……eg current data is -1885, serial sending .58810=.58810=……
No communication under overload status.

(3). Serial mode (TF=3):


All data are ASCII code,every frame is composed with 8-byte(included decimal point), data is sent from
bottom to top bit, every frame has a separation symbol “=” , sending current weight data, eg current data is
188.5, serial sending 5.88100=5.88100=……eg current data is -1885, serial sending 58810-=.58810-=……
No communication under overload status.

(4). Serial mode (TF=4):(compatible Toledo T800)without checksum


Serial mode (TF=5):(compatible Toledo T800)with checksum
Each byte of data consists of 10 bits. The first bit is start bit. The 10th bit is stop bit. The 8 bits inside are
the data bits. Continuous output is 18 bytes of every frame data.

Continuous output format 2


StX A B C X X X X X X X X X X X X CR CKS
1 2 3 4 5 6
Notes :
1. <StX> ASCII means starting/beginning symbol (02H) 。
2. Status word is A , B , C 。
3. Displayed weight data probably gross or net weight. 6 bit without symbol and decimal point
number
4. Tare weight ,6 bit without symbol and decimal point number
5. <CR> ASCII Enter (ODH) 。
6. <CKS> Checksum.
Status word A
Bits 0 , 1 , 2
0 1 2 decimal point
position
0 0 0 KGKG00
1 0 0 KGKGX0
0 1 0 KGKGKG
1 1 0 KGKGX.X
0 0 1 KGKG.KG
1 0 1 KGX.KGX
0 1 1 KG.KGKG
1 1 1 X.KGKGX
Bits 3 , 4
3 4 Divided value
factor
1 0 X1
0 1 X2
1 1 X5
6
Bit 5 Fixed 1
Bit 6 Fixed 0

Status word B
Bits Function
Bit 0 Gross weight = 0 , Net weight = 1
Bit 1 Sign : Postive = 0 , Negative = 1
Bit 2 Overload (or less than zero ) = 1
Bit 3 Dynamic = 1
Bit 4 Unit : kg = 1
Bit 5 Fixed 1
Bit 6 As 1 when the indicator is powered

Status word C
Bit 0 Fixed 0
Bit 1 Fixed 0
Bit 2 Fixed 0
Bit 3 With printing order = 1
Bit 4 External display (X10) = 1
Bit 5 Fixed 1
Bit 6 Fixed 0

You might also like