Proctors Ground Protection Brochure

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

Ground Gas Protection

WE’VE GOT GROUND GAS COVERED

System Solution Providers


Group

1 SYSTEM SOLUTION PROVIDERS
Contents
A. Proctor Group Ground Gas Protection
Experts in ground gas protection systems
Introduction Pages 4-9
The A. Proctor Group Ltd is a family-owned company in
its fourth generation which has been providing solutions • Total Solution Capabilities
and products to the construction industry for over 50 • Why are gas protection measures needed?
years. One of our five core divisions is Ground Gas • Types of Gases
Protection Systems.
• Building Regulations

Gas protection systems are critical in developments


constructed on sites affected by permanent ground gas
and/or volatile organic compound (VOC) contamination.
Systems are designed using the methodology which is set
out in various advisory documents and legislation. The
Product Range Pages 10-17
primary purpose is the prevention of hazardous gases and
• Protech VOC Flex
contaminants from the underlying soils that may cause
harm to occupiers. A well-designed system should also • Protech GM Super
perform the function of a damp-proof membrane, assisting • Protech Radon 400
in preventing the uptake of moisture into the construction. • Protech Liquid Applied Gas Membrane
• Protech Self Adhesive Gas Membrane
• Provoid 25
• Provoid 40
• Provoid 12
• Protech GM Accessories

Services & Support Pages 18-19

• Technical Support


2 SYSTEM
SYSTEM SOLUTION
SOLUTION PROVIDERS
PROVIDERS 3 PRODUCT SOLUTION PROVIDERS
Ground Gas Protection

Total Solution Capabilities


Our products are backed up by a dedicated team of technical experts, able to assist at every project stage
from pre-planning to on-site. Whatever your requirement, our highly trained specialists are on hand to
provide technical advice to assist in all aspects of designing gas protection systems. From recommending the
ideal level of protection for a particular site, through to the selection of suitable materials, and advice on
detailing, our team will work with you to ensure that all elements are covered.
As part of providing this complete service to customers, we
have developed relationships with strategic partners; these From concept to completion
include:

• Consultants specialising in all aspects of gas protection


system design RESEARCH
• Specialist installation sub-contractors PERFORMANCE
IN USE
& INNOVATION
• Consultants offering independent verification of gas
protection installations

The A. Proctor Group can facilitate contact between
TECHNICAL HIGH QUALITY
our clients and professional companies in the field of gas SUPPORT MANUFACTURE
protection systems, who can offer quotations for:

• Full design of systems in line with site-specific


investigation, and remediation strategy covered by £1m Group

professional indemnity ADVANCED


PRODUCT
• Installation of gas protection measures by CSkills NVQ SYSTEM DESIGN SOLUTIONS
Level 2 qualified installation contractors
• Verification by independent consultants providing
PERFORMANCE
validation plans including relevant levels of integrity testing MODELING
specific to site risks

The A. Proctor Group has been a contributor and funder to


various CIRIA advisory documents including C665, C716 and
C735.


4 SYSTEM SOLUTION PROVIDERS 55 PRODUCT
SYSTEM SOLUTION
SOLUTION PROVIDERS
PROVIDERS
Types of Gases
RADON (Rn)
Radon is a radioactive, colourless, odourless gas which occurs naturally in the environment, and can migrate into any
building that is built over a source. If it accumulates in a building, it increases the risk of lung cancer for occupants. In 2009,
the World Health Organisation (WHO) stated that radon is the cause of 15% of lung cancers worldwide.

CARBON DIOXIDE (CO2)


Carbon Dioxide is toxic, odourless and colourless, and in high concentrations can result in asphyxiation. The gas is formed
by the oxidation of carbon compounds such as that which occurs in landfill sites. When CO2 levels reach a concentration
of 3%, symptoms of headaches and shortness of breath will occur; these become severe at 5%, at 7 - 10% will cause
suffocation and at 22% is fatal.

METHANE (CH4)
An odourless flammable gas that is explosive when released
into the atmosphere at levels as low as 5%, and exposed
to a source of ignition. Methane is formed where there is
below-ground degradation of organic substances e.g. landfill
sites, sewage treatment areas, mining operations and peat
bogs.

Ground Gas Protection


Why are gas protection measures needed? 1. Structural barrier (floor & substructure design)
The accepted industry methodology of determining the risk to 2. Ventilation protection (floor slab type)
an end-user of a building, in line with guidance and legislation, 3. Membranes
comprises ‘source,’ ‘pathway’ and ‘receptor.’ This methodology is 4. Monitoring and detection
used by design consultants during the creation of the conceptual 5. Pathway intervention
site model to provide the remediation strategy, in the context of
the associated risks specific to the site and construction. Depending on the site risks present, these components will be
used to determine the overall protection system chosen. At
Current legislation and advisory documents stipulate levels of the A. Proctor Group we have been involved in the supply and
protection required, depending on the specific permanent ground specification of gas protection systems since 1990, specifically in VOLATILE ORGANIC COMPOUNDS (VOCs)
gas or VOC risks associated with the site. Landfill or naturally the areas of venting and dilution, and membranes.
VOCs are organic compounds that are volatile under normal
occurring gas (or its components) can enter buildings through:
Our PROVOID ventilation system is backed by a proven track environmental/atmospheric conditions. They can be found
• Gaps around service pipes record in the supply of quality materials for passive ventilation in the ground in solid, liquid and dissolved state, and as
• Construction joints systems. As well as the necessary pipework arrangements, the gases. Some VOCs are short-lived, therefore their impact
• Wall cavities system is provided with options on air inlets and outlets to suit
can change rapidly as they degrade to other chemicals.
• Cracks in walls and ground slabs specific site requirements.
Typical VOCs encountered on brownfield and industrial sites
In most buildings, measures to protect against ground gas are The A. Proctor Group also supplies the PROTECH GM range of include: Petroleum (non-halogenated) hydrocarbons (e.g.
constructed below the ground floor level. A permanent ground proprietary gas barrier membranes, designed to protect against benzene, toluene, butylbenzenes).Halogenated hydrocarbons
gas (or VOC) protection solution consists of several individual permanent ground gases and VOCs. Our specialist technical (e.g. chlorinated ethenes, ethenes and associated breakdown
elements, combining to form an integrated system. This is team is available to advise on membrane specification to tailor
specifications to individual site requirements, and can also advise
products as from dry-cleaning fluids or degreasers or
done to limit the reliance on one individual component. These
components are separately designated, concerning gas protection on levels of required installation and verification. chlorofluorocarbons [freons]) Nitrogen, sulphur and oxygen-
in BS8485:2015 + A1 2019 (permanent ground gas) and CIRIA containing organic compounds (e.g. tetrahydrofuran).
C748 (VOCs), as: Our range of reinforced gas barriers is complemented with a
variety of sealing tapes, tophats, self-adhesive flashings and gas
resistant DPCs.

6 SYSTEM SOLUTION PROVIDERS 7 PRODUCT SOLUTION PROVIDERS
Building Regulations - designing for performance Building Regulations - designing for performance
Background VOCs
When faced with a site with VOC contamination, it is important to carefully identify the specific VOC contaminants present
There have been numerous changes to legislation over the last 10 years in relation to to find the right solution. It is not as simple as requesting a ‘Hydrocarbon vapour proof barrier.’ Consideration needs to be
sites affected by permanent ground gases and VOC contamination. Approved Document given to specific vapour modelling of the membrane being proposed. CIRIA C716 (2012)8 contains recommendations that sites
with VOC issues require ventilation. This was to address a degree of design confusion as some sites with VOCs were having
C (2004)1 sets out the basic procedures for sites affected with contamination, however ventilation omitted due to the point scoring system built into BS8485 (2007), together with CIRIA C748 (2014) which provides
more up to date guidance is available through British Standards (BSi) and the CIRIA suite of guidelines on the VOC Migration into Buildings. It is worth noting that BS8485:2015 +A1 2019 relates to permanent gas and
does not necessarily apply to sites with VOC contamination.
documents relating to contamination.
Independent validation is stipulated as a requirement on sites with VOC contamination, with relevant integrity testing which is
Radon (Rn) set out in CIRIA C735 (2017).
Protection from radon is set out in BRE report 211 (2015)2. This document is somewhat
out of date, and improved legislation is being looked at. Since it was published, the WHO’s Summary
2009 report3 found that 15% of lung cancer cases were linked to radon, which would equate At the A. Proctor Group, we can offer design advice to maintain adherence to all relative legislation and guidance specific to
to approximately 6500 new cases of lung cancer each year in the UK. The Health & Safety your site. If required we can arrange contact for clients with companies who can offer full designs covered by professional
Executive states that around 1100 premature deaths occur each year due to radon. The indemnity. We also offer Product Presentations on current ground protection legislation and design requirements, or the
Radon Council recommends an emphasis on better-designed ventilation below the slab Protech GM Range.
and reinforced proprietary gas barriers, rather than 2000g DPMs, along with independent
validation of the designed measures on a particular project.

Permanent Ground Gas


Gases such as carbon dioxide and methane or landfill gas are referred to as ‘permanent
gas.’ CIRIA C665 (2007)4 introduced gas screening value calculations, allowing sites to be
characterised between 1 - 6. Gas screening value calculations are also used in BS8485:2015 References;
1 Dept of Environment (2004) Approved document C
+A1 20195, where the building type and characteristic situation are paired to give a point
2 BRE (2015) Radon: Guidance on protective measures for new buildings
score to achieve relevant protection. Points are allotted to the system dependent on the 3 The World Health Organisation (2009) The radon handbook
structural barrier (ground floor slab), ventilation protection and the membrane. Housing 4 Wilson S, Oliver S, Mallett H, Hutchings H and Card G (2007) CIRIA C665 – Assessing risk posed by hazardous ground gas to buildings
and public buildings require more points than industrial and commercial buildings, due to the 5 BSi British Standards (2015) BS8485 – Code of practice for the design of protective measures for methane and carbon dioxide ground gases for new
higher risk to the receptor. buildings
6 Wilson S, Card G and Haines S (2011) The chartered institute of environmental health ground gas handbook
There is now a greater emphasis not only on the quality of materials used but also on the 7 Mallett H, Taffel-Andureau L, Wilson S and Corban M (2014) CIRIA C735 – Good practice on the testing and verification of protection systems for building
design performance of ventilation systems, together with their installation and verification. against hazardous ground gases
It is now recommended that installation teams attain Construction Skills NVQ Level 2 8 Welburn P, Baker K, Borthwick K and MacLoed C (2012) CIRIA C716 – Remediating and mitigating risks from VOC vapours from land affected by con-
tamination
qualifications in gas membrane installation. Also, the requirement for independent validation
and integrity testing (if required) is set out in BS8485:2015 +A1 2019, CIEH Ground Gas
8 Handbook (2009)6 and CIRIA C735 (2014)7.
SYSTEM SOLUTION PROVIDERS 9 PRODUCT SOLUTION PROVIDERS
Protech VOC Flex Protech GM Super
High risk characteristic sites 20/5723
High risk characteristic sites

Protech VOC Flex complies with CIRIA C748 and BS8485:2015 +A1 2019. It is a high performance 6 layer flexible proprietary Protech GM Super is a high performance proprietary reinforced gas barrier, that incorporates a integral aluminium foil layer, for
reinforced VOC gas barrier and is suitable for use on brownfield sites that require protection from dangerous contaminants such maximum protection against ground-borne gases. This has been specifically designed to conform with the latest guidance documents.
as hydrocarbons. Protech VOC Flex has been developed to ease installation on site due to the flexibility of the membrane. It is also Due to its unique composition, the membrane is extremely robust and flexible and, therefore, easy to install on site. The membrane
suitable as a high performance damp proof membrane. also provides protection from damp when placed below the slab and, therefore, there is no need to install a separate DPM.

TYPICAL PROPERTIES Features and Benefits


Roll Length 50m • Complies with CIRIA C748 and
BS8485:2015 +A1 2019 Features and Benefits
Width 2m TYPICAL PROPERTIES
• Exceptional chemical resistance
Weight 564g/m2 50m • BS8485:2015 +A1 2019 Compliant
• Gas resistant Roll Length
• High performance reinforced virgin
Thickness 0.55mm • BBA Certified Width 2m
polymer proprietary gas membrane
• Additional damp proofing protection
Tensile Strength
700 N/50mm Weight 370g/m2 • Superior tear resistance
(EN 12311-1
MD • Flexible membrane to ease installation on site
CD 640 N/50mm 0.4mm • Aluminium core for reduced methane
+Mods EN 13859-1) • Robust & durable multi-layer membrane Thickness
permeability on higher risk sites
• High resistance to puncturing Colour Green / Silver
Elongation • Complies with the latest guidance
MD 30%
(EN 12311-1
CD 25% Accessories Methane Permeability (ISO 15105-1) ≤ 0.1 ml/day/m2 • BBA certified
+Mods EN 13859-1)
• Protech VOC Flex Starter Band • Robust and flexible
• Protech GM Tophats • Easy to install
Nail tear resistance MD 500 N
• Protech GM Flashing
REGULATIONS COMPATIBILITY
(EN 12310-1) CD 540 N
• Protech GM Corners CIRIA 665
CHARACTERISTIC
CIRIA 665
CHARACTERISTIC
BS8485
CHARACTERISTIC
BS8485
CHARACTERISTIC
BRE 211 NHBC NHBC AMBER 2
• Protech GM Primer SITUATION 2 SITUATION 3-6 SITUATION 2 SITUATION 3-6
RADON AMBER 1 & RED

• Protech Protection Board METHANE N/A


• Protech GM Protection Fleece
CARBON
• Protech Liquid Applied Gas Membrane DIOXIDE
N/A

(LAGM) RADON N/A N/A N/A N/A N/A N/A

INSTALLATION The table above can be used as a basic guide but for site specific guidance please contact the A. Proctor Group technical department

Protech VOC flex can be sealed by welding. In areas where the membrane crosses cavity walls or internal single skin walls, Protech VOC
Flex Starter Band should be used in conjunction with Protech VOC Flex Internal and External preformed corner units. Pipe penetrations
Accessories
should be sealed with Protech GM Tophats or Protech GM Flashing Strips. Stanchions and columns should be sealed with Protech GM
Primer and Protech GM Flashing strips (Photos, isometric and standard details are available on our website). • Protech GM Super Starter Band • Protech GM Primer • Protech SAGM
(1m x 50m) • Protech Protection Board (Self Adhesive Gas Membrane)
• Protech GM Tape • Protech GM Protection Fleece • Protech LAGM
• Protech GM Tophats • Protech DPC (Liquid Applied Gas Membrane)
• Protech GM Flashing
• Protech GM Corners

For further information regarding permeation testing results please visit our website www.proctogroup.com or contact our technical
department on 01250 872261.

10 SYSTEM SOLUTION PROVIDERS 11 PRODUCT SOLUTION PROVIDERS
Protech Radon 400 Protech Liquid Applied Gas Membrane (LAGM)
High risk characteristic sites High risk characteristic sites
Protech Radon 400 is a high performance proprietary reinforced gas barrier, for maximum protection against ground-borne gases Protech LAGM is a liquid applied single component acrylic modified coating that once cured, provides a waterproof, damp proof,
particularly radon. Due to its unique composition, the membrane is extremely robust and flexible and, therefore, easy to install on radon, methane and carbon dioxide barrier. Independent 3rd party test certificate / data available.
site. It can be jointed with use of our Protech tapes or heat welded. The membrane also provides protection from damp when
placed below the slab and, therefore, there is no need to install a separate DPM. Features and Benefits
TYPICAL PROPERTIES
• 0.7mm thick (dry film) coating provides an
Components 1 effective methane barrier when applied to
most clay or cementitiousbase construction
TYPICAL PROPERTIES Features and Benefits Form Thixotropic Liquid materials
• Elastic and durable material to give protection • Effective waterproof membrane
Roll size 2m x 50m Specific Gravity 1.40 (approx)
against methane gas • Excellent adhesion, bonds to porous and
Thickness 0.43mm • Easy to install Application Temp Plus 4°C non-porous substrates
Weight 400g/m2 • Wide temperature range • Flexible
Toxicity Non - toxic
Sd value 290m
• Non-toxic
Thickness Minimum 0.7 mm (applied in two layers). • Will withstand temporary light trafficking
Resistance to static loading 20kg Accessories • Hard to puncture as fully bonded
Size 20 litre
• Protech Radon 400 Flex Starter Band • Easily repaired by locally over-coating
Water tightness W1
Against heat ageing (EN 1296) W1 • Protech GM Tophats Weight 23.4kg • Can be painted, plastered or screeded over
Against chemicals (EN 1847) W1 • Protech GM Flashing • Rapid drying, in good conditions two coats
• Protech GM Corners Cured Properties can be applied in the same day
MD 320N
Tearing strength
CD 330N
• Protech GM Primer • Can be applied by brush, roller or airless
• Protech Protection Board Adhesion to concrete 1.1N/mm2
spray
MD 385 N/50mm • Protech GM Protection Fleece
Tensile strength
CD 295 N/50mm • Can be applied to damp and ‘green’
• Protech Liquid Applied Gas Membrane Elongation ASTM D2370 % > 100%
substrates
MD 20% (LAGM)
Elongation
CD 17% Tensile Strength ASTM D2370 11 N/mm2

Foldability at low temperature Pass (-45°C)

1.4.10-8 m/s
Radon transmittance
INSTALLATION
Radon permeability 6.0.10-12 m2/s
Application of the main coating system
INSTALLATION • The product can be applied by stiff brush, roller or airless spray with a minimum 0.43mm nozzle. The spray method is especially
suitable for less accessible locations and uneven substrates.
Protech Radon 400 is a flexible construction membrane with excellent barrier properties against Radon and other ground gases. Material • The first Protech LAGM primer application is applied at the rate of >0.3lt/m for effective gas and water resistance. Ensure that
is designed to be used in conjuction with solid and suspended ground floor applications. the coating is even; use a circular action when spraying.
• Allow the primer coat to dry before applying the second coat.
• Apply the second coat at the rate of >0.5lt/m for effective gas and water resistance; for brush application, apply at right angles
to the first coat. Again use a circular action when spraying. Application rate will depend on substrate surface.
• Do not apply over bitumen.
• The total application thickness must not exceed 4mm if splitting or cracking is to be avoided.
• Protect from frost and rain.
• Only apply when temperature is 5°C and rising.


12 SYSTEM SOLUTION PROVIDERS 13 PRODUCT SOLUTION PROVIDERS
Protech Self Adhesive Gas Membrane (SAGM) Provoid 25
High risk characteristic sites High risk characteristic sites
Protech SAGM is a self adhesive gas and waterproofing membrane for use in detailing and vertical installation applications. Protech Provoid 25 is a 25mm thick single-sided geocomposite that provides a void beneath floor slabs which, when connected to air inlets
SAGM can be used on any site where Carbon Dioxide, Radon or Methane is present. Methane will occur on any construction, and outlets, allows sufficient air changes to dilute gases to safe concentrations when designed correctly.
on any sites previously used for landfill. Such conditions can exist on household, commercial and industrial sites. Protech SAGM
is perfect for detailing work around awkward penetrations and finishes. It is suitable for vertical, horizontal, stepped and cavity Provoid 25 can be laid in strips at predetermined centers or in a full blanket depending on site requirements. Being only 25mm
applications, however care should be taken when applying to porous materials that Protech GM Primer be used first. Protech SAGM thick means there is a reduced dig when compared to the alternative of 200 to 300mm of clean stone. If Provoid is laid in strips it
should be installed in accordance with manufacturers instructions. Protech SAGM consists of an aluminium/polythene laminate must be bedded in 200mm of clean stone to achieve a good venting performance in compliance with BS8485:2015. Provoid 25 is
coated on one surface, and a bitumen-polymer adhesive compound. also extremely strong and flexible with a crush resistance of 300 kpa and is supplied in rolls of 45m2; therefore large areas can be
covered very quickly.

TYPICAL PROPERTIES Accessories Provoid 25 is flexible and can be laid horizontally and vertically to deal with awkward foundation arrangements. Because of its
• Protech GM Flashing flexibility, it will cope easily with settlement under the slab without compromising the system.
Roll Length 19.05m
• Protech GM Primer
Width 1.05m • Protech Protection Board We offer venting design advice in line with DOE (1997) Passive venting of soil gases beneath buildings. We can offer venting layouts
Thickness 1.5mm and detailing of inlets and outlets on existing foundation slab layouts.

Weight 1700 g/m2 Features and Benefits


• Fully compliant with
PHYSICAL CHARACTERISTICS BS8485:2015 +A1 2019 TYPICAL PROPERTIES Features and Benefits
• Self-Adhesive Membrane • 25mm Geocomposite Void • Compatible with Protech GM
Tensile Strength (N / 50mm) EN 12311-2 Roll Length 50m
• Multi Layer Membrane Former which results in less Range of Gas Membranes
CD CD ≥ 2N/mm2 Width 450mm / 900mm
incorporating a aluminimum foil contaminated spoil compared • Optimised for maximum
MD MD ≥ 2N/mm2
layer Thickness 25mm to a ‘pipe and gravel’ venting strength and performance
Elongation (%) EN 12311-2 • Flexible Membrane to ease Compressive strength 300 kPa layer • UV stabilised
CD ≥ 120% installation on site • Flexible and easy to lay • Allows for a reduced dig
Gas flow capacity - Composite 0.07 m3/s (Calculated1)
MD ≥ 120% • Tanking Applications • Large rolls available for • High crush resistance
Methane Permeability • Excellent for detailing work 1
Gas flow calculation based on a discharge coefficient of 0.61 with a pressure reduced installation times • Excellent flow rate
< 10 ml/(m2.day.atm) difference of 10Pa and a standard air density of 1.29kg/m3
(ISO 15105-1) • Full range of ancillary
products
Water vapour transmission
0.013 g/(day/m2)
properties

1 Accessories**
Example Venting System Components
INSTALLATION 7,000mm2 ventilation area
2
1: Ground Level Gully Vent Box*
2: Provoid Connector ‘T-Piece’
Protech SAGM has an easily removal silicone coated paper on the lower side. Release liner should only be removed at the time
3: Provoid (Geotextile side down)
of use. SAGM installation must not be carried out below 5°C and some warming with a hot air gun may be required between
temperatures of 5 and 10°C to ensure a satisfactory seal. Ensure exact positioning prior to removal of the release film, as product
* Provoid Gully Vent Boxes need to be set in 150mm surround
will adhere instantly and any repositioning may compromise the adhesive properties.
of no fines concrete. No vehicular trafficking should be driven
3 over Gully Vents.
** Please refer to Protech GM Accessories brochure for full
range

14 SYSTEM SOLUTION PROVIDERS 15 PRODUCT SOLUTION PROVIDERS
Provoid 40 Provoid 12
High risk characteristic sites High risk characteristic sites
Provoid 40 is a 40mm think single-sided geocomposite that provides a void beneath floor slabs which , when connected to air Provoid 12 is a 12mm thick single-sided geocomposite that provides a void beneath floor slabs to provide a Pressure Relief
inlets and outlets, allows sufficient air changes to dilute gases to safe concentrations when designed correctly. Pathway for gas. Provoid 12 can be laid in strips at predetermined centres or in a full blanket depending on site requirements.
When using Provoid 12 Geocomposite as a Pressure Relief Pathway it can be laid on any prepared sub-base medium and vented
Provoid 40 should be laid in a full blanket depending on site requirements. Provoid 40 is particularly efficient when a Very Good to the exterior of the building. When Provoid 12 is used as a Pressure Relief System the maximum points score is 0.5 points in
Performance is required under the BS8485:2015 guidelines. accordance to BS8485:2015.

We offer venting design advice in line with DOE (1997) Passive venting of soil gases beneath buildings, We can offer venting layouts If a ventilation score of ‘Good’ or ‘Very Good’ is required to comply with BS8485:2015, please refer to our Provoid 25 and Provoid
and detailing of inlets and outlets on existing foundation slab layouts. 40 datasheet.

TYPICAL PROPERTIES Features and Benefits TYPICAL PROPERTIES Features and Benefits
Roll Length 25m • Optimised for maximum strength and Roll Length 50m • Optimised for maximum strength and
performance performance
Width 970mm Width 1m
• UV stabilised • Allows for a reduced dig
Thickness 40mm • Allows for a reduced dig Thickness 12mm • High crush resistance
Compressive strength 100 kPa • High crush resistance Compressive strength 500 kPa • Excellent flow rate
Gas flow capacity - Composite 0.033 m /s (Calculated )
3 1 • Excellent flow rate

1
Gas flow calculation based on a discharge coefficient of 0.61 with a pressure
difference of 10Pa and a standard air density of 1.29kg/m3

Accessories** Accessories**
Example Venting System Components Example Venting System Components
7,000mm2 ventilation area 7,000mm2 ventilation area
1 1: Ground Level Gully Vent Box* 1 1: Ground Level Gully Vent Box*
2: Provoid Connector ‘T-Piece’ 2: Provoid Connector ‘T-Piece’
3: Provoid (Geotextile side down) 3: Provoid (Geotextile side down)
2 2
* Provoid Gully Vent Boxes need to be set in 150mm surround * Provoid Gully Vent Boxes need to be set in 150mm surround
of no fines concrete. No vehicular trafficking should be driven of no fines concrete. No vehicular trafficking should be driven
over Gully Vents. over Gully Vents.
** Please refer to Protech GM Accessories brochure for full ** Please refer to Protech GM Accessories brochure for full
3 range 3 range


16 SYSTEM SOLUTION PROVIDERS 17 PRODUCT SOLUTION PROVIDERS
Protech GM Accessories Specialist Services and Technical Support
Both the British Standard BS8485:2015 and the CIRIA C735 guidance document emphasise the importance of on site verification to
ensure design performance targets for gas membrane systems are met. In order to achieve this, good installation and site practices are Our technical back-up has always been an integral part of our strategic development, with an
increasingly important. To assist contractors in meeting the strict guidance given in the most recent standards documents, the A Proctor
Group supplies a wide range of membrane accessories to ensure the installation process is both simple and robust. outlook based on advanced technical solutions, rather than commodity driven.
Please refer to our Protech GM Accessories brochure for full product details. Our dedicated technical team is focused on providing high quality advice and support to our
customers all the way from drawing board to site.

Customer Focused
Protech Foil
Protech GM Flashing Protech GR-DPC Lap Tape
• Online Technical Advice
Protech GM Tape
• CAD Design / Standard
Details
• Site Advice
• CPD Presentations
Protech GM Primer Protech GM Super Starter Band • Webinars
• Accreditations

Protech GM Corners Protech GM Tophats Protech Protection Board

Provoid Gully Vent Box


Expertise and know-how to support your project
BIM OBJECTS PRODUCT DIVISIONS
Our range of Performance Specifications & BIM content, We provide a wide range of high quality, innovative solutions
covering our Condensation Control Membranes, External which are designed to meet the continuously evolving
Provoid Ground Level
Gas Vent Box Provoid Solid Collection Pipe Airtight Barriers, Acoustics Flooring Solutions, Ground Gas requirements of the construction industry.
Protection Systems & Thermal Insulation range is now available Product divisions include:
in a combination of Revit Project files (.rvt), Revit Detail • Condensation Control
Component files (.rfa), Industry Foundation Class files (.ifc) • Acoustic Floor Solutions
& PDF format. • External Airtight Barriers
Provoid BTB • Ground Gas Protection
Provoid T Connectors GAS PROTECTION TECHNICAL SUPPORT
Connectors 900mm open Provoid Flat T Periscopic Connector • Thermal Solutions
We can review Site Investigation Reports including Gas
Monitoring Results and advise routes for compliance. Full
Get in touch for more information
Ground Gas Protection System Design available. CIRIA, NHBC www.proctorgroup.com | +44 (0) 1250 872261
& Building Regulations compliant. We also have close links to [email protected]
Specialist Installers who are qualified to NVQ Level 2 in Gas
End caps for
Provoid T Provoid Gas Venting Membrane Installation as recommended in CIRIA C735.
Connectors Provoid Vertical Adaptor Bollards

Provoid Horizontal Adaptor Provoid Vertical Adaptor


18 SYSTEM SOLUTION PROVIDERS 19 PRODUCT SOLUTION PROVIDERS
“ I believe the success of the A. Proctor Group
is down to a solid foundation of innovation
backed up by an excellent, loyal and committed
team, every one of them playing an important
role in our continued success. Scotland provides
us with a unique platform to launch our ideas,
systems and products. I am fiercely proud of
this heritage and our brand.”

Keira Proctor
Managing Director, A. Proctor Group Ltd

The contents of this literature are provided by A. Proctor Group Limited (APG) in good
faith and considered to be factual and accurate at the date of publication. These
do not constitute specific technical recommendations and are provided for general
information purposes only. It is for the engineer, architect or other relevant professional
www.proctorgroup.com | +44 (0) 1250 872261 engaged to advise on any project to assess and satisfy themselves on the suitability
[email protected] of APG products for their intended use on that project. Please note that information
contained in this literature may be subject to change with advances in usability and
experience.
20