NetEngine 8000 M14 Service Router Datasheet

Download as pdf or txt
Download as pdf or txt
You are on page 1of 20

Datasheet

NetEngine 8000 M14 Series Universal


Service Router

Overview
HUAWEI NetEngine 8000 M14 all-scenario intelligent router is a high-end intelligent router launched by Huawei for the industry.
It is mainly used in access and aggregation scenarios to form an intelligent and simplified IP bearer network solution with
simplified architecture, intelligent connection, and committed high availability. The details are as follows:

(1) The NetEngine 8000 M14 breaks through multiple technical difficulties, such as ultra-high-speed signal transmission,
super heat dissipation, and efficient power supply. It achieves a compact and large capacity of 5U/2T bit/s and 220 mm.
It is the most compact router in the industry. Supports a full series of interfaces to meet the traffic growth and diversified
service access requirements in the cloud era. Currently, Ethernet, SDH and PDH interfaces are supported, and PCM
interfaces are supported in the roadmap. NetEngine 8000 M14 is a full-scenario converged platform that supports
home broadband, private line, mobile bearer, and cloud bearer scenarios, simplifying network layers and complexity.
The network slicing (FlexE) function implements multi-purpose and comprehensive bearer on one network.

(2) NetEngine 8000 M14 supports SRv6 and enables intelligent connections. Based on IPv6, SRv6 provides a large
number of continuous addresses and rich scalability capabilities, implements automatic cross-domain connection and
minute-level service provisioning, and implements cloud scheduling network and one-hop to the cloud. SRv6 can
identify applications and tenants and implement intelligent traffic steering such as latency and bandwidth based on
customer requirements to ensure service SLA. The number of network protocols is reduced from 10+ to 2, simplifying
network O&M.

(3) The NetEngine 8000 M14 supports intelligent O&M. Automation and intelligent technologies are introduced to
implement intelligent O&M. Based on iMaster NCE, the In-situ Flow Information Telemetry (IFIT) technology accurately
detects network SLAs in real time, visualizes service quality in real time, and supports minute-level fault locating.
Unique ROAM algorithm, intelligent traffic steering and optimization; The intelligent algorithm reduces the number of
displayed alarms by 99%.

The product fully supports the future-oriented next-generation unified network SRv6 technology and can be used to build IP
backbone, metro, mobile backhaul, and data center networks. It can be used for individual/enterprise cloud migration, inter-
cloud interconnection, IoT, government and enterprise private lines, home broadband applications, and CDN. As a basic bearer
protocol of the entire network, SRv6 implements end-to-end full-service bearer capabilities. SRv6 enables simplified protocols,
large-scale networking, seamless integration, high reliability, integrated service chains, network and service programmability,
and a full ecosystem.

⚫ Support for the Deterministic IP (DIP) technology. The periodic scheduling mechanism prevents cross-period packet
collisions and ensures deterministic delay when nodes are processing data.

⚫ Support for data redundancy elimination (DRE) to compress and decompress data between WAN border routers,

1
reducing bandwidth consumption of WAN links, reducing line costs, and accelerating the deployment of distributed data
centers.

The NetEngine 8000 series router integrates multiple functions, simplifies the network structure, provides rich service types ,
reliable service quality, and intelligent O&M. It leads the IP WAN to an intelligent network with self-driving driving, and
continuously drives the business success of enterprise customers.

NetEngine 8000 M14 DC NetEngine 8000 M14 AC NetEngine 8000 M14 AC

(High performance) (Normal)

Product Features
Features of Huawei NetEngine 8000 M14 Series Routers

Feature Description

Interface type 400G/100GE/50E/40GE/25GE/10GE/GE/FE/E1/cPOS/POS

Typical port density 100GE:20; 50GE:28; 25GE:80; 10GE:140; GE:280

Ethernet layer 2 protocol G.8032, STP/RSTP, MSTP, L2 protocol transparent transmission, BPDU, LACP

Ethernet service VLAN, Bridge domain, L2TPv3, QinQ, MTU per port 9600 bytes

Routing RIP, RIPng, OSPF, OSPFV3, IS-IS, IS-ISV6, BGP, BGPv6, Static routing, IPv4 Multicast,
IPv6 multicast, multicast static, BIERv6

IPv4 TCP/IP, for example, ICMP, IP, TCP, UDP, Socket (TCP/UDP/RAW IP), ARP
Static DNS, DNS Client
FTP Server, FTP Client
TFTP Client
DHCP Relay, DHCP Server
Ping, Tracert, NQA
IP policy-based routing
Forwarding next hop based on traffic
IP policy-based route load balancing
The QinQ interface (QinQ termination and dot1q termination) supports IPv4 load balancing.
Enabling and disabling the rapid ping reply function based on interface boards
Forcible fragmentation for packets with length greater than MTU and DF enabled
MPLS-in-UDP tunnel egress

IPv6 IPv6 (ND)


Path MTU (PMTU)
TCP6
Ping IPv6
Tracert IPv6

2
Feature Description
Socket IPv6
DHCPv6 Relay
Static IPv6 DNS
TFTP IPv6 Client
IP policy-based routing
IPv6 ND fast reply

MPLS LDP, MPLS TE, Segment Routing MPLS,MPLS-TP

L2VPN PWE3/VLL, VPLS, VXLAN

L3VPN CE routers can access the L3VPN through L3 interfaces.


Support static routes between CE and PE, BGP, RIPv1/v2, OSPF and IS-IS
Inter-AS VPN, including RFC2547bis option A
Inter-AS VPN, including RFC2547bis option B
Inter-AS VPN, including RFC2547bis option C
NG-MVPN
IPv6 VPN
HoVPN
Seamless MPLS
BGP LSP entropy label
Redirect to VPN
L3VPN PIPE/Uniform mode
L3VPN statistics

⚫ IS-IS for SRv6, OSPFv3 for SRv6, SRv6 TE Policy, SRv6 TE Policy Shortcut, SRv6 Flex-
Algo, SRv6 SRH compression, SRv6 network slicing
SRv6
⚫ BGP for SRv6, SRv6 BE, SBFD for SRv6 BE, SRv6 TI-LFA FRR, SRv6 middle-node
protection, SRv6 micro-loop avoidance, SRv6 OAM, SRv6 SFC, G-SRv6

EVPN EVPN E-LAN/E-Line/E-Tree, EVPN L3VPN, EVPN VXLAN, PBB EVPN

VAS BNG/BRAS (IPoE/PPPoE), NAT/CGN, IPsec, MACsec, SA, data redundancy elimination

Clock Physical layer synchronization, 1588v2 ACR, ATR, G.8275.1, SMPTE-2059-2, CES ACR

OAM Telnet, SSHv1/v2, command line interface


AAA RADIUS and TACACS
SNMP v1/v2c/v3
IFIT, IP FPM, NQA, TWAMP, BFD, telemetry
MPLS OAM, MPLS-TP OAM
VRRP
Ethernet OAM, IEEE 802.3ah, IEEE 802.1ag, Y.1731
Ethernet LPT
Bit-error-triggered protection switching
Syslog
NETCONF
YANG

QoS 5-level HQoS, QPPB, DiffServ, HQoS, redirection

3
Product Specifications
NetEngine 8000 M14 AC
Item Description

Cabinet installation standards ETSI 21-inch; IEC 19-inch

Dimensions without packaging (H x W x D) [mm(in.)] 222 mm x 442 mm x 220 mm (8.74 in. x 17.4 in. x 8.66 in.)

Chassis height [U] 5U

Weight without packaging [kg (lb)] 14.6 kg (32.19 lb)

Weight without packaging (full configuration) [kg (lb)] [IPU-2T/IPU-2T-B] AC: 30.0 kg (66.15 lb)
[IPU-1T2/IPU-1T2-B] AC: 30.0 kg (66.15 lb)

Typical power consumption (with configuration) [W] [IPU-2T/IPU-2T-B] AC: 1*fan+4*AC


power+2*IPU+2*CR5DE2NE4X14+1*CR5D00E8XM25+3*CR5D00LA
XF91+1*CR5D00EAGF95=968.36 W

[IPU-1T2/IPU-1T2-B] AC: 1*fan+2*AC


power+2*IPU+2*CR5DE2NE4X14+3*CR5D00LAXF91+2*CR5D00EA
GF95=935.81 W

Typical heat dissipation (with configuration) [IPU-2T/IPU-2T-B] AC: 1*fan+4*AC


[BTU/hour] power+2*IPU+2*CR5DE2NE4X14+1*CR5D00E8XM25+3*CR5D00LA
XF91+1*CR5D00EAGF95=3057.69 BTU/hour
[IPU-1T2/IPU-1T2-B] AC: 1*fan+2*AC
power+2*IPU+2*CR5DE2NE4X14+3*CR5D00LAXF91+2*CR5D00EA
GF95=2953.16 BTU/hour

MTBF [year] 147.34 years

MTTR [hour] 0.5 hours

Availability 0.999999613

Power supply mode AC

Rated input voltage [V] 200 V to 240 V/100 V to 127 V dual live wires, support 240 V HVDC

Input voltage range [V] 90 V to 290 V

Maximum input current [A] 10 A

Rated output power [W] 2500 W

Maximum input cable size [mm²] Standard C13 cable

Front-end circuit breaker/fuse [A] ≥ 10 A

4
Item Description

Heat dissipation mode Air cooling

Airflow direction From left to right

Noise at normal temperature (acoustic power) < 72 dB (meeting the ETSI 72 dBA standard)
[dB(A)]

Number of slots 17

Number of service board slots 10

Switching capacity IPU-2T/IPU-2T-B: 4 Tbit/s

IPU-1T2/IPU-1T2-B: 2.4 Tbit/s

Redundant IPUs 1:1

Redundant power supply 2+2

Redundant fans 3+1. Short-term running when a single fan becomes invalid at the
ambient temperature of 40°C (104°F)(one fan module contains four
fans)

Long-term operating temperature [°C(°F)] –20°C to +55°C (–4°F to +131°F), start: ≥ –5°C (23°F)

Restriction on the operating temperature variation ≤ 30°C/hour (54°F/hour)


rate [°C(°F)]

Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)

Long-term operating relative humidity [RH] 5% to 85% RH, non-condensing

Short-term operating relative humidity [RH] 5% to 95% RH, non-condensing

Storage relative humidity [RH] 5% to 95% RH, non-condensing

Long-term operating altitude [m(ft.)] ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to
4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the
device decreases by 1°C [33.8°F] each time the altitude increases by
220 m [721.78 ft.].)

Storage altitude [m(ft.)] < 5000 m (16404.199 ft.)

NetEngine 8000 M14 AC


Item NetEngine 8000 M14

Cabinet installation standards ETSI 21-inch; IEC 19-inch

Dimensions without packaging (H


222 mm x 442 mm x 220 mm (8.74 in. x 17.4 in. x 8.66 in.)
x W x D) [mm(in.)]

5
Item NetEngine 8000 M14

Chassis height [U] 5U

Weight without packaging (full


[IPU-1T2-A/IPU-1T2-BN]AC:26.0kg(57.32 lb)
configuration) [kg(lb)]

Typical power consumption (with [IPU-1T2-A/IPU-1T2-BN]AC: 1*fan+2*AC


configuration) [W] power+2*IPU+2*CR5D0E5XMF94+2*CR5D00LAXF91+2*CR5D00EAGF70=485.59 W

[IPU-1T2-A/IPU-1T2-BN]AC: 1*fan+2*AC
Typical heat dissipation (with
power+2*IPU+2*CR5D0E5XMF94+3*CR5D00LAXF91+2*CR5D00EAGF70=988.03
configuration) [BTU/hour]
BTU/hour

MTBF [year] 147.34

MTTR [hour] 0.5 hours

Availability 0.999999613

Power supply mode AC

Rated input voltage [V] 200 V to 240 V/100 V to 127 V dual live wires, support 240 V HVDC

Input voltage range [V] 90 V to 290 V

Maximum input current [A] 10 A

Rated output power [W] 1500 W

Maximum input cable size [mm²] Standard C13 cable

Front-end circuit breaker/fuse [A] ≥10 A

Heat dissipation mode Air cooling

Airflow direction From left to right

Noise at normal temperature


< 72 dB (meeting the ETSI 72 dBA standard)
(acoustic power) [dB(A)]

Number of slots 17

Number of service board slots 10

Switching capacity IPU-1T2-A/IPU-1T2-BN:2.4 Tbit/s

Maximum number of physical


220
ports on the entire device

Maximum number of 100GE ports IPU-1T2-A/IPU-1T2-BN:9

Maximum number of 50GE ports IPU-1T2-A/IPU-1T2-BN:18

Maximum number of 40GE ports IPU-1T2-A/IPU-1T2-BN:9

Maximum number of 25GE ports IPU-1T2-A/IPU-1T2-BN:36

Maximum number of 10GE ports IPU-1T2-A/IPU-1T2-BN:90

Maximum number of GE ports IPU-1T2-A/IPU-1T2-BN:220

Maximum number of FE ports IPU-1T2-A/IPU-1T2-BN:220

6
Item NetEngine 8000 M14

Maximum number of electrical


IPU-1T2-A/IPU-1T2-BN:120
ports

Redundant IPUs 1:1

Redundant power supply 1+1

3+1. Short-term running when a single fan becomes invalid at the ambient temperature
Redundant fans
of 40°C (104°F)(one fan module contains four fans)

Long-term operating temperature


-20°C to 55°C(-4°F to 131°F), start: ≥ –5°C(23°F)
[°C(°F)]

Restriction on the operating


temperature variation rate [°C(° ≤ 30°C/hour (54°F/hour)
F)]

Storage temperature [°C(°F)] -40°C to 70°C(-40°F to 158°F)

Long-term operating relative


5% to 85% RH, non-condensing
humidity [RH]

Short-term operating relative


5% to 95% RH, non-condensing
humidity [RH]

Storage relative humidity [RH] 5% to 95% RH, non-condensing

≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft.
Long-term operating altitude
to 13123.2 ft.], the operating temperature of the device decreases by 1°C [33.8°F]
[m(ft.)]
each time the altitude increases by 220 m [721.78 ft.].)

Storage altitude [m(ft.)] < 5000 m (16404.199 ft.)

NetEngine 8000 M14 DC


Item Description

Cabinet installation standards ETSI 21-inch; IEC 19-inch

Dimensions without packaging (H x W x D) [mm(in.)] 222 mm x 442 mm x 220 mm (8.74 in. x 17.4 in. x 8.66 in.)

Chassis height [U] 5U

Weight without packaging [kg (lb)] 10.1 kg (22.27 lb)

Weight without packaging (full configuration) [kg (lb)] [IPU-2T/IPU-2T-B] DC: 28.5 kg (62.84 lb)

[IPU-1T2/IPU-1T2-B] DC: 28.5 kg (62.84 lb)

[IPU-1T2-A/IPU-1T2-BN] DC: 25.6 kg (56.44 lb)

Typical power consumption (with configuration) [W] [IPU-2T/IPU-2T-B] DC: 1*fan+2*DC


power+2*IPU+2*CR5DE2NE4X14+1*CR5D00E8XM25+3*CR5D00LA
XF91+1*CR5D00EAGF95=905.6 W

[IPU-1T2/IPU-1T2-B] DC: 1*fan+2*DC


power+2*IPU+2*CR5DE2NE4X14+3*CR5D00LAXF91+2*CR5D00EA
GF95=875.15 W

7
Item Description
[IPU-1T2-A/IPU-1T2-BN] DC: 1*fan+2*DC
power+2*IPU+2*CR5D0E5XMF94+2*CR5D00LAXF91+2*CR5D00EA
GF70=454.12 W

Typical heat dissipation (with configuration) [IPU-2T/IPU-2T-B] DC: 1*fan+2*DC


[BTU/hour] power+2*IPU+2*CR5DE2NE4X14+1*CR5D00E8XM25+3*CR5D00LA
XF91+1*CR5D00EAGF95=2859.5 BTU/hour

[IPU-1T2/IPU-1T2-B] DC: 1*fan+2*DC


power+2*IPU+2*CR5DE2NE4X14+3*CR5D00LAXF91+2*CR5D00EA
GF95=2761.75 BTU/hour

[IPU-1T2-A/IPU-1T2-BN] DC: 1*fan+2*DC


power+2*IPU+2*CR5D0E5XMF94+2*CR5D00LAXF91+2*CR5D00EA
GF70=933.94 BTU/hour

MTBF [year] 147.1 years

MTTR [hour] 0.5 hours

Availability 0.999999612

Power supply mode DC

Rated input voltage [V] –48 V/–60 V

Input voltage range [V] –40 V to –72 V

Maximum input current [A] 60 A

Rated output power [W] 2400 W

Maximum input cable size [mm²] 16 mm^2, 10 mm^2 (0–14 meters) recommended, 16 mm^2 (15–23
meters) recommended

Front-end circuit breaker/fuse [A] ≥ 63 A

Heat dissipation mode Air cooling

Airflow direction From left to right

Noise at normal temperature (acoustic power) < 72 dB (meeting the ETSI 72 dBA standard)
[dB(A)]

Number of slots 19

Number of service board slots 14

Switching capacity IPU-2T/IPU-2T-B: 4 Tbit/s


IPU-1T2/IPU-1T2-B: 2.4 Tbit/s
IPU-1T2-A/IPU-1T2-BN: 2.4 Tbit/s

8
Item Description

Redundant IPUs 1:1

Redundant power supply 1+1

Redundant fans 3+1. Short-term running when a single fan becomes invalid at the
ambient temperature of 40°C (104°F) (one fan module contains four
fans)

Long-term operating temperature [°C(°F)] –20°C to +55°C (–4°F to +131°F), start: ≥ –5°C (23°F)

Restriction on the operating temperature variation ≤ 30°C/hour (54°F/hour)


rate [°C(°F)]

Storage temperature [°C(°F)] –40°C to +70°C (–40°F to +158°F)

Long-term operating relative humidity [RH] 5% to 85% RH, non-condensing

Short-term operating relative humidity [RH] 5% to 95% RH, non-condensing

Storage relative humidity [RH] 5% to 95% RH, non-condensing

Long-term operating altitude [m(ft.)] ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to
4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the
device decreases by 1°C [33.8°F] each time the altitude increases by
220 m [721.78 ft.].)

Storage altitude [m(ft.)] < 5000 m (16404.199 ft.)

Regulatory Compliance
Item Description

Regulatory compliance EMC


⚫ ANSI C63.4
⚫ AS/NZS CISPR 32
⚫ CISPR 24
⚫ CISPR 32
⚫ EN 55024
⚫ EN 55032
⚫ ETSI EN 300 386
⚫ ETSI ES 201 468
⚫ FCC CFR47 Part 15 Subpart B
⚫ ICES-003 Issue 6
⚫ ICES-GEN Issue 1
⚫ IEC 61000-3-2
⚫ IEC 61000-3-3
⚫ IEC 61000-4-11
⚫ IEC 61000-4-2
⚫ IEC 61000-4-29

9
Item Description
⚫ IEC 61000-4-3
⚫ IEC 61000-4-4
⚫ IEC 61000-4-5
⚫ IEC 61000-4-6
⚫ IEC 61000-6-2
⚫ IEC 61000-6-4
⚫ VCCI-CISPR 32
Environment

⚫ IEC 60068-2-30

⚫ IEC 60068-2-78

⚫ IEC 60068-2-14

⚫ IEC 60068-2-1

⚫ IEC 60068-2-2

Safety

⚫ IEC/EN/UL/CSA 60950-1

⚫ IEC/EN 62368-1

Environmental protection

⚫ 2011/65/EU & (EU)2015/863 (EU RoHS)

⚫ Regulation (EC) No.1907/2006 (REACH)

⚫ 2012/19/EU (WEEE)

⚫ 2006/66/EC & 2013/56/EU on batteries and accumulators

◼ In the physical dimensions shown in the table, the width (W) does not include the rack-mounting ears.

◼ Temperature and humidity are measured at 1.5 m (4.92 ft.) above the floor and 0.4 m (1.31 ft.) in front of the cabinet. There
should be no protection board on the front or back of the cabinet.

◼ "Short-term" refers to continuous working time that does not exceed 96 hours and accumulated working time per year that
does not exceed 15 days. If the working time exceeds either of these values, it is considered "long-term".

Ordering Information
Basic Hardware Configurations
NetEngine 8000 M14 Basic Configurations

Order Name Description

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASDC1
Chassis,2*IPU-2T, 2*DC Power,without Software Charge and Document)

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASAC1
Chassis,2*IPU-2T, 4*AC Power,without Software Charge and Document)

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASDC2
Chassis,2*IPU-1T2, 2*DC Power,without Software Charge and Document)

10
Order Name Description

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASAC2
Chassis,2*IPU-1T2, 4*AC Power,without Software Charge and Document)

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASDC5
Chassis,2*IPU-1T2-A, 2*DC Power,without Software Charge and Document)

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASAC5
Chassis,2*IPU-1T2-A, 2*AC Power,without Software Charge and Document)

NetEngine 8000 M14 Integrated DC Chassis Components (Including 2*DC


CR8B0BKPDCC1
Power,Fan Box)

NetEngine 8000 M14 Integrated AC Chassis Components (Including 4*AC


CR8B0BKPACC2
Power,Fan Box)

NetEngine 8000 M14 Integrated AC Chassis Components (Including 2*AC


CR8B0BKPACC1
Power,Fan Box)

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASDC7
Chassis,2*IPU-2T-B, 2*DC Power,without Software Charge and Document)

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASDC9
Chassis,2*IPU-1T2-B, 2*DC Power,without Software Charge and Document)

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASDCB
Chassis,2*IPU-1T2-BN, 2*DC Power,without Software Charge and Document)

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASAC7
Chassis,2*IPU-2T-B, 4*AC Power,without Software Charge and Document)

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASAC9
Chassis,2*IPU-1T2-B, 4*AC Power,without Software Charge and Document)

NetEngine 8000 M14 Basic Configuration (Includes NetEngine 8000 M14


CR8P02BASACB
Chassis,2*IPU-1T2-BN, 2*AC Power,without Software Charge and Document)

CR8D0IPU2TC1 Integrated Network Processing Unit (IPU-2T)

CR8DIPU1T2C3 Integrated Network Processing Unit (IPU-1T2)

CR8DIPU1T2C5 Integrated Network Processing Unit (IPU-1T2-A)

CR8D0IPU2TC3 Integrated Network Processing Unit (IPU-2T-B)

CR8DIPU1T2C7 Integrated Network Processing Unit (IPU-1T2-B)

CR8DIPU1T2C9 Integrated Network Processing Unit (IPU-1T2-BN)

CR8M002FBXC1 NetEngine 8000 M14 Fan Box

DP52PDC2K4A1 Power Interface Board

ETP4860-4KW AC Power Box

PAC1K5S53-AL AC-DC Power,-40degC,65degC,90V,264V,53.5V/28.04A

DP52APIUCA00 AC Power Interface Unit Converting Board

Interface Cards

Minimum Version
Order Name Description
Required

CR8D00E1KBC0 1-Port 400GBase-QSFP-DD Physical Interface Card(PIC)

11
Minimum Version
Order Name Description
Required

1-Port 400GBase-QSFP-DD Physical Interface Card


CR8DE1NEKB11
CM(Enable 1*100G)(PIC)

CR8SA0EXE0C0 NetEngine 8000 M Series 100G upgrade to 200G Port


Enable RTU

CR8SA0EXK0C0 NetEngine 8000 M Series 100G upgrade to 400G Port


Enable RTU

CR8SE0EXK0C0 NetEngine 8000 M Series 200G upgrade to 400G Port


Enable RTU

2-Port 100GBase/50GBase-QSFP28 FlexE MACsec


CR8D00E2NBC4 V8R21C10SPC600
Physical Interface Card(PIC)

2-Port 50GBase/1-Port 100GBase-QSFP28 FlexE MACsec


CR8D00E1NBC2 V8R21C10SPC600
Physical Interface Card(PIC)

4-Port 25GE(SFP28)/10GE(SFP+) MACsec Physical


CR8D00E4YFC0 V8R21C10SPC600
Interface Card (PIC)

4-Port 10GE(SFP+)/GE(SFP) MACsec Physical Interface


CR8D00E4XFC3 V8R21C10SPC600
Card(PIC)

10-Port 10GE/GE LAN/WAN-SFP+ MACsec Physical


CR8D00EAXFC1 V8R21C10SPC600
Interface Card(PIC)

CR8D00E8GEB2 8-Port 100/1000Base-RJ45 Physical Interface Card(PIC) V8R21C10SPC600

10-port 100/1000Base-X-SFP MACsec Physical Interface


CR8D00EAGFCA V8R21C10SPC600
Card(PIC)

20-Port 100/1000Base-X-CSFP/10-Port 100/1000Base-X-


CR8D00EEGFXA V8R21C10SPC600
SFP Physical Interface Card(PIC)

CR8D000DE1C2 16-Port E1 Physical Interface Card(PIC,75ohm/120ohm) V8R21C10SPC500

Service Cards
Order Name Description Remarks

NetEngine 8000 M Series Integrated Service Card


CR8D0CGNA0C1 CGN Service Basic Configuration (Including 1 CGN
VSUP-100+20Gbps Capacity for CGN)

NetEngine 8000 M Series Integrated Service Card


CR8SCGN10GC0 CGN
CGN Service 10Gbps Capacity RTU

N1-N8KM14NATS-LIC N1-NetEngine 8000 M14 Series Integrated Service


CGN
Card CGN Service 1M NAT Session License

N1-N8KM14NATDP-LIC N1-NetEngine 8000 M14 Series Integrated Service Including DS-Lite, PCP,
Card CGN Service Enhanced Function License and NAT64 (V8R22C10)

N1-N8KM14NATS- N1-NetEngine 8000 M14 Series Integrated Service


CGN
SNS1Y Card CGN Service 1M NAT Session License SnS

N1-N8KM14NATDP- N1-NetEngine 8000 M14 Series Integrated Service


CGN
SNS1Y Card CGN Service Enhanced Function License SnS

12
Order Name Description Remarks

NetEngine 8000 M Series Integrated Service Card


CR8DVSUIPSC0 IPsec Service Basic Configuration (Including 1 IPSec
VSUP-100+20Gbps Capacity for IPsec)

CR8SIPS10GC0 NetEngine 8000 M Series Integrated Service Card


IPSec
IPsec Service 10Gbps Capacity RTU

N1-N8KM14IPsec-LIC N1-NetEngine 8000 M14 Series IPsec Tunnel


IPSec
Quantity License(500 Tunnels)

N1-N8KM14IPsec- N1-NetEngine 8000 M14 Series IPsec Tunnel


IPSec
SNS1Y Quantity License(500 Tunnels) SnS

CR8PMDVSUPM0 NetEngine 8000 M Series Integrated Service Card


SA Service Basic Configuration (Including 1 VSUP- Service awareness
100+4Gbps Capacity for SA)

CR8S8MSA4GM0 NetEngine 8000 M Series Integrated Service Card


Service awareness
SA Service 4Gbps Capacity RTU

CR8D0DREA0C1 NetEngine 8000 M Series VSU Redundancy


Data redundancy
Elimination Basic Configuration (Including 1 VSUP-
elimination
100+4Gbps Capacity for DRE)

RTU
Order Name Description Remarks

NetEngine 8000 M Series Flexible Card 4*155M 03033YLL


CR8SM004S1C0
POS Port Enable RTU

NetEngine 8000 M Series Flexible Card 4*622M 03033YLL


CR8SM004S4C0
POS Port Enable RTU

Software Configuration
Software License for NetEngine 8000 M14

Order Name Description Remarks

N1-NetEngine 8000 Series M14 Foundation SW


N1-N8KM14F-LIC
License

N1-NetEngine 8000 Series M14 Advanced SW


N1-N8KM14A-LIC
License
N1-NetEngine 8000 M14 Series Foundation to
N1-N8KM14F2A-LIC
Advanced SW License
N1-NetEngine 8000 M14 Series Time
N1-N8KM14TMSY-LIC
Synchronization Function License

13
Order Name Description Remarks

N1-N8KM14SRV6-LIC N1-NetEngine 8000 M14 Series SRv6 Function


License

N1-N8KM14SLI-LIC N1-NetEngine 8000 M14 Series Port Slicing Function


License

N1-N8KM14MACS-LIC N1-NetEngine 8000 M14 Series MACsec Function


License
N1-NetEngine 8000 M14 Series IPSec Function
N1-N8KM14IPS-LIC
License
N1-NetEngine 8000 M14 Series BNG Function
N1-N8KM14BNG-LIC
License
N1-NetEngine 8000 M14 Series Subscribers
N1-N8KM14S1K-LIC
Quantity(1k Subscribers)
N1-NetEngine 8000 M14 Series iFIT Enhanced
N1-N8KM14IFE-LIC
Package
N1-NetEngine 8000 M14 Series Smart OAM
N1-N8KM14OAM-LIC
Package
N1-NetEngine 8000 M14 Series Foundation SW
N1-N8KM14F-SNS1Y
License SnS(1 year)

N1-NetEngine 8000 M14 Series Advanced SW


N1-N8KM14A-SNS1Y
License SnS(1 year)

N1-NetEngine 8000 M14 Series Foundation to


N1-N8KM14F2A-SNS1Y
Advanced SW License SnS(1 year)

N1-N8KM14TMSY-SNS1Y N1-NetEngine 8000 M14 Series Time


Synchronization Function License SnS(1 year)

N1-N8KM14SRV6-SNS1Y N1-NetEngine 8000 M14 Series SRv6 Function


License SnS(1 year)

N1-N8KM14SLI-SNS1Y N1-NetEngine 8000 M14 Series Port Slicing Function


License SnS(1 year)

N1-N8KM14MACS-SNS1Y N1-NetEngine 8000 M14 Series MACsec Port


Function License SnS(1 year)

N1-N8KM14IPS-SNS1Y N1-NetEngine 8000 M14 Series IPSec Port Function


License SnS(1 year)

N1-N8KM14BNG-SNS1Y N1-NetEngine 8000 M14 Series BNG Function


License SnS(1 year)

N1-NetEngine 8000 M14 Series iFIT Enhanced


N1-N8KM14IFE-SNS1Y
Package SnS

N1-NetEngine 8000 M14 Series Smart OAM


N1-N8KM14OAM-SNS1Y
Package SnS

N1-N8KM14ZTA-LIC N1-NetEngine 8000 M14 Series Zero Trust Access V800R022C10

14
Order Name Description Remarks
Function License

N1-NetEngine 8000 M14 Series Host-based V800R022C10


N1-N8KM14HIPS-LIC
Intrusion Prevention System Function License

N1-NetEngine 8000 M14 Series Configuration Check V800R022C10


N1-N8KM14CC-LIC
Function License

N1-NetEngine 8000 M14 Series G-SRv6 32bit SRH V800R022C10


N1-N8KM14SRV6D1-LIC
Compression Function License

N1-NetEngine 8000 M14 Series G-SRv6 16bit SRH V800R022C10


N1-N8KM14SRV6D2-LIC
Compression Function License

N1-NetEngine 8000 M14 Series Energy-Saving V800R022C10


N1-N8KM14ESave-LIC
Enhanced Function Package 1.0

N1-NetEngine 8000 M14 Series Zero Trust Access V800R022C10


N1-N8KM14ZTA-SNS1Y
Function License SNS

N1-NetEngine 8000 M14 Series Host-based V800R022C10


N1-N8KM14HIPS-SNS1Y
Intrusion Prevention System Function License SNS

N1-NetEngine 8000 M14 Series Configuration Check V800R022C10


N1-N8KM14CC-SNS1Y
Function License SNS

N1-NetEngine 8000 M14 Series G-SRv6 32bits SRH V800R022C10


N1-N8KM14SRV6D1-SNS1Y
Compression Function License SnS

N1-NetEngine 8000 M14 Series G-SRv6 16bits SRH V800R022C10


N1-N8KM14SRV6D2-SNS1Y
Compression Function License SnS

N1-NetEngine 8000 M14 Series Energy-Saving V800R022C10


N1-N8KM14ESave-SNS1Y
Enhanced Function Package 1.0 SnS

Optical/Electrical Transceivers
400Gbps Optical Transceiver

Order Name Description Remarks

High Speed Transceiver,QSFP-DD FR4-4*100Gb/s PAM4(1310nm


OSK002N01
Band)-425Gb/s--3.3dBm-3.5dBm--7.6dBm-LC straight-SMF-2km

High Speed Transceiver,QSFP-DD LR8-8*56Gb/s PAM4(1310nm)-


OSK010N02
425Gb/s--2.8dbm-5.3dbm--9.1dbm-LC-SMF-10km

High Speed Transceiver,-QSFP-DD ER8-8*50Gb/s PAM4(1310nm


OSK040N02
Band),-425Gb/s--0.6dBm-6.4dBm--16.1dBm-LC straight,SMF,40km

OSK080N04 High Speed Transceiver,QSFP-DD,193.7THz,478.75Gb/s,-10dBm,-

15
Order Name Description Remarks
6dBm,-20dBm,LC,SMF,ZR(with OA)

100Gbps Optical Transceiver

Order Name Description Remarks

High Speed Transceiver,QSFP28,850nm,100G,-8.4dBm,2.4dBm,


OMND10N13
-10.3dBm,MPO,MM,0.1km,OM4

High Speed Transceiver,QSFP28,1310nm,4*25GBase,


OSN020N15
-6.5dBm,2.5dBm,-9.8dBm,LC/PC,2km (100GBASE-CWDM4)

High Speed Transceiver,QSFP28,1310nm,100G,-4.3dBm,4.5dBm,


OSN010N24
-8.6dBm,LC,SMF,10km

High Speed Transceiver,QSFP28,1310nm,100G,-2.5dBm,2.9dBm,


OSN030N05
-21.4dBm,LC,SMF,30km

QSFP28-100G- High Speed Transceiver,QSFP28,1310nm,100G,3dBm,6.5dBm,


1310nm-80km-SM -30dBm,LC,SMF,80km

High Speed Transceiver,CFP2,4*25Gb/s(1310nm Band),103.125Gb/s,


OSN010N09
-4.3dBm,4.5dBm,-10.6dBm,LC straight,SMF,10km

High Speed Transceiver,CFP2,1310nm,103.125Gb/s,-2.9dBm,2.9dBm,


OSN040N03
-21.4dBm,Straight LC,SMF,40km,OMA,100GBASE-ER4

CFP2-100G-1310nm- High Speed Transceiver,CFP2,1310nm,103.125Gb/s,3dBm,6.5dBm,


80km-SM -30dBm,Straight LC,SMF,80km

CFP2-Coherent- High Speed Transceiver,CFP2,C extend band tunable,50GHz ITU


DCO-100G-SM grid,134.7Gbit/s,-10dBm,1dBm,-30dBm,LC,SMF

50Gbps Optical Transceiver

Order Name Description Remarks

High Speed Transceiver,QSFP28,1311nm,50Gb/s,-4dBm,4.2dBm,


OSL010N01
-8.8dBm,LC,SMF,10km

QSFP28-50G- High Speed Transceiver,QSFP28,1310nm,53.125G,1.5dBm,8dBm,


1311nm-40km-SM -15dBm,Straight LC,SMF,40km

QSFP28-50G- High Speed Transceiver,QSFP28,1311nm,50G,two-fiber bidirectional,

16
Order Name Description Remarks
1310nm-80km-SM 80km

QSFP28-50G-BIDI- BiDi Transceiver,QSFP28,1331nm(TX)/1271nm(RX),50G,-4.5dBm,


10km-SM-1 4.2dBm,-8.9dBm,LC,10km

QSFP28-50G-BIDI- BiDi Transceiver,QSFP28,1271nm(TX)/1331nm(RX),50G,-4.5dBm,


10km-SM-2 4.2dBm,-8.9dBm,LC,10km

QSFP28-50G-BIDI- BiDi Transceiver,QSFP28,1295nm(TX)/1309nm(RX),50G,1.5dBm,8dBm,


40km-SM-2 -13.5dBm,LC,40km

QSFP28-50G-BIDI- BiDi Transceiver,QSFP28,1309nm(TX)/1295nm(RX),50G,1.5dBm,8dBm,


40km-SM-1 -13.5dBm,LC,SMF,40km

40Gbps Optical Transceiver

Order Name Description Remarks

High Speed Transceiver,QSFP+,1310nm,41.25Gbps,-7dBm,


OMXD30009
2.3dBm,-11.5dBm,LC,SMF,10km

High Speed Transceiver,QSFP+,850nm,41.25Gbps,-7.6dBm,


OMXD30010
0.5dBm,-9.5dBm,MPO,MMF,0.15km

High Speed Transceiver,QSFP+,1310,41.25Gbps,-8.2dBm,


OSM010N11
0.5dBm,-12.6dBm,MPO,SM,10km

25Gbps SFP28 Optical Transceiver

Order Name Description Remarks

SFP28-25G- High Speed Transceiver,SFP28,1310nm,25G,-7dBm,2dBm,


1310nm-10km-SM -11.3dBm,LC,SMF,10km

SFP28-25G- High Speed Transceiver,SFP28,850nm,25G,


850nm-0.1km-MM -8.4dBm,2.4dBm,-10.3dBm,LC,MM,0.1km

SFP28-25G-BIDI- BiDi Transceiver,SFP28,1270nm(Tx)/1330nm(Rx),25Gb/s,-


10km-SM-3 4dBm,2dBm,-10.3dBm,LC,10km,-40~85degc

SFP28-25G-BIDI- BiDi Transceiver,SFP28,1330nm(Tx)/1270nm(Rx),25Gb/s,-


10km-SM-4 4dBm,2dBm,-10.3dBm,LC,10km,-40~85degc

SFP28-25G- High Speed Transceiver,SFP28,1310nm,25G,-7dBm,2dBm,-


1310nm-300m-SM 10.5dBm,LC,SMF,0.3km

17
10Gbps SFP+ Optical Transceiver

Order Name Description Remarks

Optical Transceiver(SFP+,850nm,10Gb/s,-7.3~-1dBm,-11.1dBm,LC,
OSX040N03
MM,0.3km)

Optical Transceiver(SFP+,1310nm,10Gb/s,-8.2~0.5dBm,-12.6dBm,
OSX001002
LC,SM,10km)

Optical Transceiver(SFP+,1550nm,9.95~11.1Gb/s,-4.7~4dBm,
OMXD30002
-14.1dBm,LC,SM,40km)

Optical Transceiver(SFP+,1550nm,9.953~10.3125Gb/s,0~4dBm,
OSX080N04
-24dBm,LC,SM,80km)

1.25/9.953/10.3125Gbps SFP+ Optical Transceiver

Order Name Description Remarks

XFP SFP+ Transceiver-SFP+-1310nm-10G/1G--8.2dbm-0.5dbm-


OSX010N13
Single-mode-14.4dbm-LC-10km

1.25Gbps eSFP Optical Transceiver

Order Name Description Remarks

Optical Transceiver(eSFP,850nm,2.125Gb/s(Multi rate),-9.5~


OMGD50N02
-2.5dBm,-17dBm,LC,MM,0.5km)

Optical transceiver(eSFP,1310nm,1.25Gb/s,-9~-3dBm,-20dBm,
OSG010N05
LC,Single Mode,10km)

Optical Transceiver(eSFP,1310nm,1.25Gb/s,-5~0dBm,-23dBm,
OSG040002
LC,SM,40km)

Optical Transceiver,eSFP,1550nm,1.25Gb/s,-2~5dBm,-23dBm,
OSG080N01
LC,SM,80km

1.25Gbps eSFP BIDI Optical Transceiver

Order Name Description Remarks

Optical Transceiver,ESFP,Tx1310/Rx1490,1.25Gb/s,-3dBm,
SFP-GE-LX-SM1310-BIDI
-9dBm,-19.5dBm,LC,Single Mode,10km

Optical Transceiver,ESFP,Tx1490/Rx1310,1.25Gb/s,-3dBm,
SFP-GE-LX-SM1490-BIDI
-9dBm,-19.5dBm,LC,Single Mode,10km

Optical Transceiver,eSFP,1310nm(Tx)/1490nm(Rx),1.25Gb/s,
OGEBIDI41
-2dBm,3dBm,-23dBm,LC,SM,40km

OGEBIDI40 Optical Transceiver,eSFP,1490nm(Tx)/1310nm(Rx),1.25Gb/s,

18
Order Name Description Remarks
-2dBm,3dBm,-23dBm,LC,SM,40km

1.25Gbps CSFP BIDI Optical Transceiver

Order Name Description Remarks

BiDi Transceiver,CSFP,1490(Tx)/1310(Rx)nm,1.25Gb/s,-9dBm,-3dBm,
O00CSFP25
-19.5dBm,LC,SM,10km

BiDi Transceiver,CSFP,1310(Tx)/1490(Rx)nm,1.25Gb/s,-9dBm,-3dBm,
OSG010007
-24dBm,LC,SMF,10km

BiDi Transceiver,CSFP,Tx1490/Rx1310nm,1.25G,-5dBm,0dBm,-25dBm,
OSG040008
LC(-40~85),SM,40km

Integrated Optical Transmitting and Receiving Module,CSFP,


OSG010005 Transmitting:1490nm,Receiving:1310nm,1.25Gb/s,-9.0dBm,-3.0dBm,
-24dBm,LC,GE/FE autonegotiation

1Gbps Electrical Transceiver

Order Name Description Remarks

Optical functional module,1000BASE-T -SFP RJ45Electrical


OEGD01N02
Module,Auto Negotiate,100m ,-40~85degC

155Mbps eSFP Optical Transceiver

Order Name Description Remarks

Optical Transceiver(eSFP,1310nm,STM1,-15dBm~-8dBm,
eSFP-FE-LX-SM1310
-31dBm,Singlemode,LC,15Km)

Optical Transceiver(eSFP,1310nm,STM1,-5dBm~0dBm,
eSFP-FE-LH40-SM1310
-37dBm,Singlemode,LC,40Km)

Optical Transceiver(eSFP,1550nm,STM1,-5dBm~0dBm,
eSFP-FE-LH80-SM1550
-37dBm,Singlemode,LC,80Km)

622M SFP/eSFP Optical Transceiver

Order Name Description Remarks

Optical Transceiver(eSFP,1310nm,STM4,-15dBm~-8dBm,
OSH015N05
-30dBm,Singlemode,LC,15Km)

Optical Transceiver(eSFP,1310nm,STM4,-3dBm~2dBm,
eSFP-1310nm-L-4.1
-30dBm,Singlemode,LC,40km)

Optical Transceiver,eSFP,1550nm,STM4,-3~2dBm,
OSH080N01
-30dBm,LC,SM,80km

19
155Mbps eSFP BIDI Optical Transceiver

Order Name Description Remarks

Optical transceiver,eSFP,Tx 1310nm/Rx 1550nm,155M,-8dBm,


OSC015B01
-15dBm,-32dBm,LC/PC,SM,15km

Optical transceiver,eSFP,Tx 1550nm/Rx 1310nm,STM1,-8dBm,


OSC015B02
-15dBm,-32dBm,LC/PC,SM,15km

PCM Subcard Matching Module

Order Name Description Remarks


Optical Transceiver,eSFP,1310nm,2.048Mb/s,-15dBm,-8dBm,
OSC002B01
-26dBm,LC,SM,2km

Software Upgrade Paths


Visit Software Upgrade Paths to get VRP software release version or patches.

For More Information


For more information about the NetEngine 8000 series router, visit https://e.huawei.com or contact us in the following ways:

⚫ Global service hotline: https://e.huawei.com/en/service-hotline


⚫ Logging in to the Huawei Enterprise technical support web: https://support.huawei.com/enterprise/
⚫ Sending an email to the customer service mailbox: [email protected]

Copyright © Huawei Technologies Co., Ltd. 2023. All rights reserved.


No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the
customer. All or part of the products, services and features described in this document may not be within the
purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and
Huawei Technologies Co., Ltd.
recommendations in this document are provided "AS IS" without warranties, guarantees or representations of
any kind, either express or implied. Address:Huawei Industrial Base Bantian,
Longgang Shenzhen 518129 People's
The information in this document is subject to change without notice. Every effort has been made in the
Republic of China
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied. Website:www.huawei.com

20

You might also like