Introduction
About this manual
This manual describes precautions for the use of Plant Resource Manager (hereinafter,
PRM) to operate STARDOM.
Refer to "Plant Resource Manager Installation" (IM 33Y05Q12-11E) for the procedure
for installing the PRM package on a PC and its settings.
Related documents
• STARDOM IT Security (IM 34P02Q93-01E)
• Plant Resource Manager Reference (IM 33Y05Q10-11E)
• Plant Resource Manager Installation (IM 33Y05Q12-11E)
Safety Precautions
Important information about this manual
(1) Please ensure that end users receive this manual.
(2) Carefully read this manual and make sure you understand its contents before
operating the product.
(3) This manual provides a detailed description of the functions in the product, but it is
not intended as a guarantee of suitability for specific user objectives.
(4) Unauthorized transfer or reproduction of all or part of this manual is strictly
prohibited.
(5) The contents of this manual may be changed without notice in the future.
(6) Please contact our sales department or the dealer where you made your purchase
if you have any questions about the information in this manual, or if you discover
any errors, omissions, or the like.
This label means "handle with caution”. It is attached in locations on the product
that need to be referenced in the user's manual to ensure personal safety and
protect the equipment. In addition, the user's manual contains cautions for
avoiding danger in cases where there are possible hazards which could result in
death or injury (e.g., electric shock).
This label represents a protective ground terminal. Be sure to ground this terminal
before operating the equipment.
This label represents a functioning ground terminal. Be sure to ground this terminal
before operating the equipment.
This software
(1) Yokogawa provides no guarantees with respect to this software except if
established in the terms of a warranty.
(2) Use this software on a single, specified computer. If you wish to use the software
on another computer, please separately purchase the software for that computer.
(3) Copying of this software for purposes other than backups is strictly prohibited.
(4) Store the original disks (DVD-ROM and CD-ROMs) which contains the software in a
safe place.
(5) Reverse compiling, reverse assembly, and the like (reverse engineering) with
respect to this software are strictly prohibited.
(6) Allowing a third party to use all or part of this software, by means of transfer,
exchange, rental, or the like without the prior approval of Yokogawa is strictly
prohibited.
Menu bar menus, commands, text box names, and buttons are
enclosed
in square brackets.
Example: From the menu bar, select [Icon (E)] - [Specify file and run (F)].
(The meaning is to select [Icon (E)] from the menu bar, then select [Specify file and run
(F)] from the pulldown menu.)
Symbol marks
The symbols marks appearing in this manual have the meanings shown below.
CAUTION
This symbol means “handle with caution”.
The user's manual contains cautions for avoiding danger in cases where there are
possible hazards which could result in death or injury (e.g., electric shock).
WARNING
This symbol means “warning”.
Information under this label relates to important issues in cases where there is a risk
that the software or hardware could be damaged, or system problems could occur.
IMPORTANT
This symbol means “important”.
Information under this label relates to important issues in terms of understanding
operations and functions.
TIP
Additional explanatory information is presented under this label.
SEE ALSO
Reference items are presented under this label.
In cases where the reference item is displayed in green, you can click it to display
the reference material.
In cases where the reference item is displayed in black, you cannot click it to
display the reference material.
Diagram notation
The diagrams presented in this manual may be enhanced, simplified, or only displayed
in part in order to make the explanations easier to understand.
The screenshots in this manual may differ from the actual screen displays in terms of
display location and fonts (e.g., large/small fonts). Any differences are not significant
enough to impede understanding of the functions and operating monitoring.
STARDOM
Plant Resource Manager
IM 34P02Q52-01E 14th Edition
CONTENTS
Introduction .................................................................................................. i
Safety Precautions ..................................................................................... ii
Conventions Used in This Manual ............................................................. iv
Copyrights and Trademarks...................................................................... vii
CONTENTS ............................................................................................... ix
1. Overview ............................................................................................ 1
2. Precautions for System Configuration ................................................ 3
3. Precautions for Installation ................................................................. 5
3.1 Cautions for installing FCN/FCJ OPC Server for Windows
on the same PC with PRM ............................................................................9
3.2 Setup after installing the FCN/FCJ OPC Server for Windows .....................10
3.2.1 Setting up for remote access .........................................................10
3.2.2 HDA server startup settings ...........................................................10
3.2.3 Message collection destination definition ....................................... 11
3.2.4 HDA server settings .......................................................................12
Revision Information .................................................................................... i
1. Overview
This manual describes precautions for the use of Plant Resource Manager
(hereinafter, PRM) to operate STARDOM.
The precautions are as follows:
1. Precautions for System Configuration
2. Precautions for Installation
For other than the above, refer to the following:
Operating Environment
This manual refers to the following operating environments:
Table Operating Environment
System Revision
PRM R3.30
FCN/FCJ OPC Server for Windows R4.02
Note: PRM and FCN/FCJ OPC Server for Windows can only be used in combination with respective revisions specified in
the table.
TIP
• The FOUNDATION fieldbus described in this manual is a "FOUNDATION fieldbus H1," as
standardized by the Fieldbus Foundation.
The term "FOUNDATION fieldbus" is used to denote the "FOUNDATION fieldbus H1."
• The term "Fieldbus device" used in this manual to refer to a field device connected to a
FOUNDATION fieldbus.
Messages
The format of alerts generated from Fieldbus device differs in VDS and PRM. In VDS,
only important information is shown due to message length limitations. However, in
PRM, all information in alert messages is shown.
Likewise, alerts generated from a given piece of Fieldbus device appear differently in
PRM depending on whether the Fieldbus device is connected to STARDOM or to
CENTUM.
Time synchronization
In the CENTUM VP/CS 3000 system, the Field Communication Server time can be
synchronized with the Vnet time. To enable time synchronization in STARDOM, set the
PC so that clocks are synchronized by SNTP.
SEE ALSO
For details, see the "net time" command Help topic in Windows. Also see the STARDOM Network
Configuration Guide (TI 34P02K25-01E).
TIP
PRM components and the FCN/FCJ OPC Server for Windows can be installed on the same PC with
several limitations.
SEE ALSO
When installing FCN/FCJ OPC Server for Windows on the same PC with PRM, see 3.1 "Cautions for
installing FCN/FCJ OPC Server for Windows on the same PC with PRM" in this manual.
Figure Example system configuration for installing PRM components and FCN/FCJ OPC
Server for Windows on the different PCs
Prepare for installation See 2.2.2 "Checking Windows settings" in "Plant Resource Manager
(Set up Windows) Installation" (IM 33Y05Q12-11E)
Setup after installing the FCN/FCJ See 3.2 “Setup after installing the FCN/FCJ OPC Server for Windows” in
OPC Server for Windows this manual
Collaboration with PRM See 5.3.2 "Collaboration with PRM" in "STARDOM IT Security" (IM
Configuration on OPC Server side 34P02Q93-01E)
・ Set up the PRM Server See 3.3.2 "Setting up the PRM Server"
・ Set up the Field Communications Server See 3.3.3 "Setting up the Field Communications Server "
・ Set up the PRM Client See 3.3.4 "Setting up the PRM Client"
Install and register PLUG-IN See F3.1 "Working with PLUG-IN applications" in "Plant Resource
applications Manager Reference" (IM 33Y05Q10-11E)
: Must be performed, but must not be performed in the case of installation on the same PC
Figure Procedure for installing PRM components and FCN/FCJ OPC Server for Windows on
the different PCs
Prepare for installation See 2.2.2 "Checking Windows settings" in "Plant Resource Manager
(Set up Windows) Installation" (IM 33Y05Q12-11E)
Setup after installing the FCN/FCJ See 3.2 “Setup after installing the FCN/FCJ OPC Server for Windows” in
OPC Server for Windows this manual
Add PRM_PROCESS to the See "Installation Procedure" of 5.4.2 "Installing on the Same PC as PRM"
STM_OPC group in "STARDOM IT Security" (IM 34P02Q93-01E)
・ Set up the PRM Server See 3.3.2 "Setting up the PRM Server"
・ Set up the Field Communications Server See 3.3.3 "Setting up the Field Communications Server "
・ Set up the PRM Client See 3.3.4 "Setting up the PRM Client"
Install and register PLUG-IN See F3.1 "Working with PLUG-IN applications" in "Plant Resource
applications Manager Reference" (IM 33Y05Q10-11E)
Figure Procedure for installing PRM components and FCN/FCJ OPC Server for Windows on
the same PC
Compatibility
If you want to install FCN/FCJ OPC Server for Windows on a PC installed with PRM,
refer to the revision combination in the following table. If there are other combinations,
then FCN/FCJ OPC Server for Windows must be installed on a separate PC.
Table Compatibility
FCN/FCJ OPC Server for Windows PRM
Revision R1.90 R3.02
R2.20 R3.03, R3.04
R3.01 R3.05
R3.10 R3.05
R3.20 R3.11
R3.30 R3.11
R3.40 R3.11
R3.50 R3.20, R3.30
R4.02 R3.20, R3.30
Operating environment
The PC needs to meet with the PRM and FCN/FCJ OPC Server for Windows
specifications.
SEE ALSO
• For PRM, see 1.1.2 "Software requirements" in "Plant Resource Manager Installation" (IM
33Y05Q12-11E).
• For FCN/FCJ OPC Server for Windows, see " SYSTEM REQUIREMENTS" in "STARDOM
FCN/FCJ OPC Server for Windows" (GS 34P02Q61-01E).
Security model
When installing PRM, specify the "Legacy Model - Standalone Management" or
"Standard Model - Standalone Management" for the security setting.
IMPORTANT
• The Node identifier is a character string not including ".", "!", or ",", and setting shall
be done so that there is no duplication.
There are two FCN/FCJ, and when each FCN/FCJ host address is 192.168.0.1 and
192.168.0.2, the example.
FCN01, 192.168.0.1
FCN02, 192.168.0.2
• IP addresses are entered in decimal dot notation.
Revision Information
Title : STARDOM Plant Resource Manager
Manual No. : IM 34P02Q52-01E
*: Denotes the release number of the software corresponding to the contents of this instruction manual. The
revised contents are valid until the next edition is issued.