SPN Ztr-Pty-Man v01 4235
SPN Ztr-Pty-Man v01 4235
SPN Ztr-Pty-Man v01 4235
: 2021-05-03 : 1/2
Aktivlenkung_ZTR-PTY-MAN
Monitoring strategy
Monitoring CAN data bus message "EASI1" from MAN ComfortSteering control unit
FMI 3 Voltage above normal or short circuit to higher voltage potential
Display
Priority 4 Display ---
text
ECU conditions
Set conditions
CAN data bus message "EASI1" is received incorrectly or not at all.
Reset conditions
CAN data bus message "EASI1" is received and is plausible.
Causes
Possible causes
► AV1010 auxiliary management computer (Power Train Extended) control unit receives the CAN data bus
message "EASI1" from the MAN ComfortSteering control unit incorrectly or not at all.
► Electrical cables and plug connectors of the O1-CAN data bus between the MAN ComfortSteering
control unit and AV1010 auxiliary management computer (Power Train Extended) control unit are
damaged or disconnected.
Tests
Possible test steps
► Switch on the ignition, read out the diagnostic memory of complete vehicle using MAN-cats and check
the diagnostic memory entries.
Check software status and compatibility of the MAN ComfortSteering control unit and AV1010 auxiliary
management computer (Power Train Extended) control unit.
Check whether the electrical cables and plug connectors of the O1-CAN data bus between the MAN
ComfortSteering control unit and AV1010 auxiliary management computer (Power Train Extended)
control unit are damaged or disconnected.
SPN_4235_CAN-Datenbusbotschaft "EASI1" - Informationen Steuergerät
: 2021-05-03 : 2/2
Aktivlenkung_ZTR-PTY-MAN
Remedy
Possible remedy
Note
Additional information/notes
End of document