Plaster Accessories - Catnic
Plaster Accessories - Catnic
Plaster Accessories - Catnic
2019
1
Contents
Introduction Secure Mesh
TM
Galvanised Beads 16
PVCu Beads
Features of PVCu beads 23
PVCu Beads 24
Metal Lath
Diamond lath 32
Rib lath 33
Coil mesh 33
Mesh Arch formers 34
Mesh Arch former installation 35
2
Build it better
with Catnic
Acknowledged for our excellence of service and conformance to the highest
quality Standards for over 50 years, our products have been installed successfully in
municipal buildings and domestic properties in over 30 countries worldwide.
Building on our strength in the steel lintels market, Catnic supply a comprehensive
range of branded building components, expanded metal and plasterers’ profiles
which are manufactured to the same industry-leading high standard.
Selecting the Catnic brand assures that the products you have chosen are of superior
quality and are fully supported by our extensive distributor network.
If you need details of your local distributor, or if you require any further information
please contact.
International Sales Department
Catnic
Pontypandy Estate,
Caerphilly,
United Kingdom
CF83 3GL
Tel +44 (0) 29 2033 7900
Fax +44 (0) 29 2088 0855
www.catnic.com
3
Technically Superior Products
Our rigid adherence to quality control and compliance is
your guarantee of technical superiority.
Customer Support Fully committed to first class service support, providing the building
industry with new and improved products, borne from investment
in design and manufacturing technologies.
Full service support for customers
Catnic’s team: • Have comprehensive product and
Catnic has been at the forefront of lintel
industry knowledge
design for over 50 years. Our reputation for
• Are professional and experienced
exceptional quality and technical expertise has • H
ave a committed parent company
ensured customers satisfaction and loyalty in • Are extensively trained - Tata Steel
the products and services that we offer.
Catnic lintels have gained the approval of the regulatory authorities both in the BSI Kitemark BBA Certification
domestic and international markets. Such wide-spread comprehensive approval is Catnic steel lintels have Catnic steel lintels are
an assurance to designers, specifiers and builders of the reliability and state-of-the- been awarded the BSI certified by the British
art quality of the Catnic range. Kitemark license Board of Agrément
number KM07234. under certificate
Catnic lintels are designed, manufactured and tested in accordance with
number 91/2638.
BS EN 845-2:2003
5
Features of Catnic Lintels
Steel
Galvanised Steel
Duplex coating
Plaster key
Many Catnic lintels come complete Initially, Catnic standard lintels are
with an integral plaster key that avoid manufactured from hot-dipped galvanised
the hazards of working with a mesh steel to BS EN 10346: 2009 plus coating
key. In addition the unique design of type Z275.
the perforated base plates on CG, TS, A coating of thermal setting polyester
CH, TH, CX, TX lintels minimise cold powder is then applied by an electrostatic
bridging without affecting the structural process, further protecting the lintel. High
performance. temperature curing then produces a tough
durable surface highly resistant to impact,
abrasion and damage during rough on-site
handling. This double method of protection
Continuous gives Catnic lintels inherent benefits over
those offered by other manufacturers using
Insulation the more traditional pre- or post-galvanised
steel techniques. The protection system
Many Catnic lintels are supplied with CFC and
complies fully with the chemical and
HCFC free insulation maximising their thermal
physical test requirements outlined in table
efficiency and compliance with Part L.
2 of BS 5977: PART 2: 1983 and table C.1
The insulation is accurately shaped of BS EN 845-2: 2003 for lintels effectively
to optimise the thermal performance having their own built-in DPC.
extending continuously along the
Both of these processes rely on just a
full length of the lintel and cannot be
simple coating of zinc to provide cathodic
dislodged, leaving no potential ‘cold spots’.
protection. The zinc protects the steel, but
is itself liable to rust with aqueous alkaline
solutions leaching from the building fabric
and therefore corrode. The famous black
coating makes Catnic lintels instantly
recognisable and provides an effective
barrier against moisture or chemical attack
BS EN 845-2 : 2013
KM 07234 leached from the mortar and masonry.
7
Our range of products
is growing, view the
full selection online
catnic.com
Lintel Installation
Installation
in Minutes
Comparison of installation times with a Catnic lintel and
a conventional concrete cast in-situ lintel.
WAIT!
In the time taken to install just one concrete lintel, Total installation time
– 48 minutes
twenty four Catnic lintels could have The concrete lintel must be left to cure before
been installed. continuing with blockwork installation.
9
Lintels
Channel Lintels
For Solid Walls
Lintel Lintel Gauge Sheet Weight per Safe Working Load uniformly distributed (tonnes)
Dimension type code thickness metre Lengths available (mm) in increments of 100 (mm)
(mm)
L H code (mm) (kg) 900-1200 1300-1500 1600-1800 1900-2100 2200-2400 2500-2700 2800-3000
75 CN103 C 3.1 5.9 1.63 1.25 1.00 0.86 0.64 0.47 0.38
75 CN152 C 3.1 7.1 1.63 1.25 1.00 0.86 0.64 0.47 0.38
75 CN202 C 3.1 8.5 1.63 1.25 1.00 0.86 0.64 0.47 0.37
75 CN252C C 3.1 9.5 1.63 1.25 1.00 0.86 0.64 0.47 0.37
Standard lengths are available in increments of Standard lengths are available in increments of
150mm at lengths up to 3000mm, 300mm at lengths 150mm at lengths up to 3000mm, 300mm at lengths
from 3000mm to 4800mm (including 4575mm, but from 3000mm – 4800mm (including 4575mm, but
excluding 4500mm). excluding 4500mm).
BSD100 BSD140
Standard Duty
BHD100 BHD140
750- 1650- 2250- 2850- 3900- 750- 1650- 2250- 2850- 3900-
Heavy Duty
BXD100 BXD140
Standard lengths (mm) 750-1500 1650-2700 Standard lengths (mm) 750-1500 1650-2700
11
Lintels
Wall width Lintel dimension Lintel type/ Gauge Steel thickness Weight Safe Working Load Lengths available
(mm) W (mm) H code code (mm) (kg per metre) (tonnes) (metres)
75 65 25 CN92 - 1.2 1.2 0.7 1.05 & 1.20
100 98 25 CN102 - 1.2 1.8 0.7 1.05 & 1.20
Catnic corrugated lintels CN92 and CN102 are designed for internal These lintels are supplied in plain galvanised steel
partition walls only and are manufactured from galvanised steel to without powder coating.
BS EN 10327:2004-DX51D+Z275.
Note: When using these lintels normal building practice should be observed, in that one course of blockwork (Nominal height 200mm) should be
laid on the lintel and the mortar allowed to harden for at least 24 hours before additional loads are applied.
Lintel Brackets
External Application
Code Reference Suitable for lintels Maximum load tonnes/bracket
SB 02/15P* CN56X, CN66X 0.45 - 0.72 -
SB 02/15P/A1* CN56X, CN66X - 0.72 - 0.72
SB 02/19P* CN71, CN81, CN19/14, CN19/19 0.50 - 0.88 -
SB 02/19P/A1* CN71, CN81, CN19/14, CN19/19 - 0.88 - 0.90 Perforated
SB 02/24P* CN7, CN8 0.50 - 0.88 -
SB 02/24P/A1* CN7, CN8 - 0.88 - 1.04
SB 02/28P* CN11, CN12 0.50 - 0.88 -
SB 02/28P/A1* CN11, CN12 - 0.88 - 1.15
Metal expansion anchors quantity - diameter (mm) 2 No. M8 2 No. M10 4 No. M8 4 No. M10
Unperforated
Internal Application
Code Reference Suitable for lintels Maximum load tonnes/bracket
SB 01 CN5X, CN6X, CN100, CN1022, CN103 0.50 - 0.80 -
SB 01/A1 CN5X, CN6X, CN100, CN1022, CN103 - 0.88 - 0.90
SB 03 CN150, CN152 0.50 - 0.80 -
SB 03/A1 CN150, CN152 - 0.88 - 0.90
SB 08 CN200, CN202 0.50 - 0.77 -
Metal expansion anchors quantity - diameter (mm) 2 No. M8 2 No. M10 4 No. M8 4 No. M10
* Unperforated brackets can be supplied on request, simply delete “P” from code reference.
Lintel dimension Lintel type/ Gauge Steel thickness Weight Safe Working Lengths available
L (mm) H code code (mm) (kg per metre) Load (tonnes) (metres)
195 143 CN71 A 2.0 2.0 1.6 9.3 2.0 1.95, 2.25 in 150mm
increments
195 219 CN81 B 2.5 2.5 2.0 15.1 3.0 3.00, 3.30, 3.60
195 219 CN81 C 3.1 3.1 2.0 18.5 3.0 3.90, 4.20
CG90/100
750- 1650- 1950- 2250- 2550- 2850- 3000-
Standard lengths (mm) 2400 2700 3000 3600
1500 1800 2100
SWL 1 : 1/3 : 1 (kN) 15 18 20 22 26 26 26
Weight (kg/m) 5.8 7.3 8.0 8.6 9.8 12.3 16.0
Nominal height (mm) 140 140 160 180 220 220 220
CG90/125
Standard lengths (mm) 750-1500 1350-1800 1950-2400 2250-2700 2850-3000
SWL 1 : 1/3 : 1 (kN) 12 17 20 26 26
Weight (kg/m) 6.3 7.8 9.0 12.9 16.6
Nominal height (mm) 140 140 180 220 220
13
Plaster Beads
Plaster Beads
Our comprehensive range of Plaster Beads are precision
engineered and simple to use. Fixing by nail or plaster dab is
straightforward and fast, generating arises, edges, corners and
joints that are easy to form and resistant to chipping, cracking
and impact damage.
Block
Use one of the following
methods to fix Catnic angle
beads and plaster stop
beads:
Nails
600mm
a) Using galvanised or stainless steel nails (compatible with bead
apart
material) complying with BS 1202: Part 1, fixed at a maximum of
(max)
Bead 600mm apart. When nailing to a solid background the line of the
bead will follow the line of the background.
Plaster
Plaster Beads
b) Pressing the bead onto dabs of the same material as the undercoat,
Block dabs should be applied at a maximum of 600mm apart. This
method will even out minor irregularities in the line of the
background, although the line of the bead will tend to generally
follow the line of the background.
Plaster
Corrosion Protection
In normal circumstances, matured The use of sand or water contaminated with In general, care should be taken to ensure that
plasterwork may be regarded as dry and soluble salts in plastering mixes should be metal accessories are kept dry and distortion is
therefore non-corrosive. Risks of corrosion avoided as should soluble chlorides as they are prevented during storage and handling.
in galvanised accessories only normally likely to increase the risk of metal corrosion. Care should also be taken to prevent
becomes apparent during the initial plaster The presence of sea salts in sand used in mechanical damage to the galvanised coating.
drying out period, which should be kept to a plastering which is in contact with galvanised
minimum, and subsequently during periods accessories will often cause rust staining and Stainless steel products are for use specifically
of heavy condensation. should therefore be avoided. with cement based renders.
All backgrounds should be free of deleterious In external applications and, in conditions Catnic Plaster Beads are manufactured
substances such as mould, oil and grease and where heavy condensation, persistent damp to BS EN 13658 : 2008 - Part 1 & 2.
be adequately prepared to accommodate the or regular exposure to moisture are likely, Galvanised products are manufactured
finished surface, all beading and attendant stainless steel, PVCu or PVCu nosed products with steel in accordance to BS EN 10346:
fixings at the specified depths. should be specified. 2009-DX51D+Z275.
15
Plaster Beads
Galvanised Beads
Angle Beads
Provides true and straight corners which are resistant to chipping and cracking giving
strength and protection against everyday knocks.
B B B
W
W W
Chisel Nose Angle Bead Round Nose Angle Bead Angle Bead
4000 4001 AB 38
lengths: Shrink film Euro packaged, lengths: Shrink film Euro packaged, lengths: 50 lengths/
3.0m 25 lengths/pack 3.0m 25 lengths/pack 3.0m pack
B = 7.5mm W = 34mm B = 7.5mm W = 34mm B = 5mm W = 38mm
12mm Plaster thickness 12mm Plaster thickness 13mm Plaster thickness
B B B
W W W
Supasave Angle Bead Standard Angle Bead Wide Wing Angle Bead
SS STD WW 3.0
lengths: 50 lengths/ lengths: 50 lengths/ lengths: 50 lengths/
2.4m, 2.7m, 3.0m pack 2.4m, 2.7m, 3.0m pack 3.0m pack
B = 5mm wide W = 45mm B = 5mm wide W = 53mm B = 5mm wide W = 65mm
13mm Plaster thickness 12-19mm Plaster thickness 12-19mm Plaster thickness
B B B
W W
W
Square Hole Angle Beads - Small Nose Square Hole Angle Beads - Small Nose Square Hole Angle Beads - Round Nose
4004 4005 4006
lengths: Shrink film Euro packaged, lengths: Shrink film Euro packaged, lengths: Shrink film Euro packaged,
2.5m, 3.0m 25 lengths/pack 2.5m, 3.0m 25 lengths/pack 2.5m, 3.0m 25 lengths/pack
Galvanised Beads
Plasterstop Architrave
Provides clean, neat edges at openings or abutments onto Gives a shadow line decorative effect for aesthetic
other wall surfaces or ceiling finishes. purposes and creates a clean division between varying
wall finishes.
P W
W X
B
P
X
W
W
P
17
Plaster Beads
Galvanised Beads
Drywall and Thin Coat Plaster Applications
Designed for single/thin coat plasterwork, enabling a thin coat finish of just 3mm.
Micromesh angle beads have fine mesh wings suitable for a single/thin coat of 6mm.
B
B 85º
80º
B B
W
W
P
W B P
3mm Plaster thickness 6mm Plaster thickness 2mm Plaster thickness 2mm Plaster thickness 2mm Plaster thickness
Galvanised Beads
Movement Beads Renderstop Beads
Movement bead allows for movement between adjoining Renderstop beads are used to obtain
surfaces resulting in differential expansion and expansion a neat, bell cast lower edge to external
within the plaster /rendered area. Allows movement of +/- finishes and helps to protect masonry
3mm. Movement Beads should be installed at no greater against run-off water.
than 5m intervals. Movement Beads should not be used
over structural movement /control joints.
W P
P D
19
Plaster Beads
Galvanised Beads
with PVC Nose
Angle Beads Plasterstop Beads
Provide true and straight corners which are resistant to Provide clean and straight edges whilst the PVCu nose adds
chipping and cracking giving strength and protection the advantage of a light, non-corrosive elegant solution for
against everyday knocks whilst the PVCu nose adds the an aesthetic finish with an easy to use material.
advantage of a light, non-corrosive elegant solution for an
aesthetic finish.
W
B P
D
W
A
W
Standard Angle Bead
STD/PVC
50 lengths/pack Plasterstop Bead
2.7m, 3.0m lengths
Shrink film Euro packaged
6225 6227 6229
B = 8mm W = 53mm
12-19mm Plaster thickness 2.7m, 3.0m lengths 2.7m, 3.0m lengths 2.7m, 3.0m lengths
25 lengths/pack Shrink 25 lengths/pack Shrink 25 lengths/pack Shrink
film Euro packaged film Euro packaged film Euro packaged
Supersave Angle Bead
D = 53mm D = 53mm D = 53mm
ABPVC13
W = 14mm W = 10mm W = 20mm
50 lengths/pack
2.7m, 3.0m lengths
Shrink film Euro packaged A = 110º A = 110º A = 110º
B = 8mm W = 45mm 14mm Plaster 10mm Plaster 20mm Plaster
10-13mm Plaster thickness thickness thickness thickness
B P W
W
B
21
Plaster Beads
Renderstop Bead
Renderstop beads are used to obtain a neat, bell cast
X
lower edge to external finishes and helps to protect
W masonry against run-off water.
P
A
Architrave without Flange
W
ARC10/WO/3.0/SS ARC13/WO/3.0/SS
3.0m lengths 3.0m lengths
25 lengths/pack 25 lengths/pack Renderstop Bead
W = 37mm W = 37mm RS3.0/SS
X = 20mm X = 20mm 3.0m lengths 50 lengths/pack
P = 10mm P = 13mm D = 45mm W = 25mm A = 120º
10mm Plaster thickness 13mm Plaster thickness 19mm Plaster thickness
PVCu Beads
Catnic PVCu Plaster beads provide all the benefits of traditional
metal beads, but with the added advantages of being a light, rigid,
non-corrosive, easy to use material, offering elegant solutions for an
aesthetic finish and providing a cost-effective way to comply with
the latest regulations.
23
PVCu Beads
PVCu Beads
Angle Beads PVCu Drip Beads
For use on all plastered and rendered corners where a true, Used above doors, windows and at DPC level offering a
sharp corner is required. Its strong rigid arris protects and profile flush with the rest of the render. The Drip Bead
reinforces plaster where it is most vulnerable. prevents the retention of water that can often bring
staining at the bottom of the render.
W
W 80º
110 -120˚
L T L
T
W T
W
W
80º 80º
L
L L
PVCu Angle Beads PVCu Twin Nose Angle Beads PVCu Thin Coat Angle Beads
PAR03/2.5 PTN12/2.5 PAB03/2.5
3 depth mm W = 24mm 8 -12 depth mm W = 26mm 3 depth mm W = 24mm
50 per box L = 2.5m 30 per box L = 2.5m 50 per box L = 2.5m
T = 3mm T = 12mm T = 3mm
Suitable for Internal and External use Suitable for Internal and External use Suitable for Internal and External use
PVCu Beads
PVCu Bell Cast PVCu Architrave T
W
25
External Wall Insulation
In addition this system can dramatically Catnic supplies a range of base track and bead In 2013 Catnic became an associated
transform the buildings exterior with a wide components designed for EWI systems. Our member of the Insulated Render and
range of contemporary or traditional finishes EWI product range is manufactured to the Cladding Association (INCA).
using different textures, colours or finished same industry-leading high standards as our
effects. The result is a comfortable living renowned steel lintels.
environment with reduced heating costs for
the occupants and an increase in property
value with extended lifespan.
Base Track
The aluminium channel provides a simple means
of locating and levelling the bottom run of
insulation boards.
The channels are available in different sizes to suit a range of
different insulation thickness.
Base Track
To suit insulation Overal Width Gauge
Product Code Length (m) Lengths/pack thickness (mm) (mm)* (mm)
8145 2.5 10 50 53 0.8
8148 2.5 10 80 83 0.8
8150 2.5 10 100 103 0.8
8152 2.5 10 120 123 1.0
8154 2.5 10 140 143 1.0
27
External Wall Insulation
29
External Wall Insulation
Fibreglass
Mesh
Fibreglass mesh provides a layer of reinforcement between
the insulation and final topcoat or finish.
Fibreglass Mesh
Fibremesh Rolls
Code FM165 Colour White Mesh Size (mm) 4 x 4mm
Description Fibreglass Mesh Roll Width (mm) 1000mm Weight 165g/m2
Application Render reinforcement Length (m) 50m Quanity Each
DuoBase
DuoBase 160–220 160mm
- 220 mm WP: 100 mm / FP: 160 mm WP: 100 mm / FP: 160 mm
montagefertige Außenecken
MaterialDas Wandprofil
bond muss auf Gehrung geschnitten
material and form-fitting co-extrusion
sein.
Holes Kantenlänge:
Round
160 mm and oval
100 cm 180 mm 200 mm 220 mm
Verpackungseinheit: 5 Außenecken (5 linke und 5 rechte Profile)
Profile connector Not required due to overlapping front
profile attached Darstellungen nicht maßstabsgetreu
31
Expanded Metal Lath
Diamond Lath
Expanded metal lath is extensively used as a background to plaster in order to reinforce against cracks and it is
especially useful at joints of dissimilar materials. Generally DL111 or DL089 lath is used for wall situations and
DL161 is used for ceiling work.
Sheet Lath
Weight
Reference S W Mesh (mm) Material Sheet size (cm)
(kg/m2)
DL089 9 0.9 Galvanised Steel 250 x 70
DL111 9 1.11 Galvanised Steel 250 x 70
DL161 9 1.61 Galvanised Steel 250 x 70
DL111S 9 1.11 Stainless Steel 250 x 70
Strip Lath
Weight
Reference Width (cm) Material Length (cm)
(kg/m2)
SL021/100/2.5 1.11 10 Galvanised Steel 250
SL021/150/2.5 1.11 15 Galvanised Steel 250
SL023/100/2.5 1.61 10 Galvanised Steel 250
SL023/150/2.5 1.61 15 Galvanised Steel 250
Coil Lath
Weight Coil length
Reference Width (cm) Material (metres)
(kg/m2)
CL021/100/100 1.11 10 Galvanised Steel 100 - 50
CL021/150/100 1.11 15 Galvanised Steel 100 - 50
CL021/200/100 1.11 20 Galvanised Steel 100 - 50
CL023/100/100 1.61 10 Galvanised Steel 100 - 50
CL023/150/100 1.61 15 Galvanised Steel 100 - 50
CL023/200/100 1.61 20 Galvanised Steel 100 - 50
Quality: Manufactured from galvanised steel to BS EN 10346: 2009 – DX51D+Z275 or Stainless Steel to BS EN 10088-2-1.4301. All products shown
are manufactured in accordance with BS EN 13658: 2005. Metal Lath - Definitions, Requirements, Test Methods. Part 1 for Internal Plastering.
Part 2 for External Plastering.
Sheet Lath
Weight
Reference Material Size (cm) Rib Height (mm)
(kg/m2)
RIB148 1.48 Galvanised Steel 250 x 60 10
RIB184 1.84 Galvanised Steel 250 x 60 10
RIB222 2.22 Galvanised Steel 250 x 60 10
RIB148 S 1.48 Stainless Steel 250 x 60 10
RIB184 S 1.84 Stainless Steel 250 x 60 10
Refurbishment of Masonry Lath should be fixed with apexes of ribs Stainless steel fixings should be used at
Stainless steel rib lath is ideal for refurbishing against the wall, edge ribs of the sheets sufficient intervals to hold the lath firmly in
damaged or aged masonry walls, when nesting into each other should be wire-tied position.
a key for rendering is not certain due to every 15cm and ends of sheets should be
disintegration or softening of the wall face. lapped not less than 2.5cm and nesting ribs
securely tied together.
Quality: Catnic expanded rib lath is manufactured in accordance with BS EN 13658: 2005. Metal Lath - Definitions, Requirements, Test Methods. Part 1
for Internal Plastering. Part 2 for External Plastering. The galvanised steel used in the manufacture of rib lath is in accordance with BS EN 10346: 2009 –
DX51D+Z275. Where stainless steel is used it is in accordance with BS EN 10088-2-1.4301.
Coil Mesh
Coil length
Reference Wall width (mm) Coil width (mm)
(metres)
CM 50 100 50 50 or 20
CM 64 114 64 50 or 20
CM 100 150 100 100, 50, 20
CM 114 164 114 100, 50, 20
CM 150 200 150 100, 50, 20
CM 178 228 178 100, 50, 20
CM 200 250 200 100, 50, 20
CM 229 279 229 100, 50, 20
CM 305 355 305 100, 50, 20
33
Expanded Metal Lath
Verona
65mm
Rise
295 x 1200mm
140mm
Extra soffit
section
Installation
1 M
easure the distance 2 Position the first section 3 F ix the other sections in the 4 T he arch is completed by
between the walls (brick of the arch to the wall and same way, aligning them at plastering directly onto the
to brick) and select the fix with the masonry nails the centre with the plastic steel mesh, using a suitable
appropriate arch size. provided. joining pieces provided. material.
If renovating, remove All arches and soffit pieces
existing plaster down to the should be joined with the self
masonry. Mark the centre of tapping screws provided.
the aperture.
Quality: The galvanised steel used in the manufacture of mesh arch formers is in accordance with BS EN 10346: 2009 – DX51D+Z275.
35
SecuraMeshTM
SecuraMesh
TM
These sheets of expanded steel mesh fit neatly into internal and external
walls, ceilings and roofs to defend premises against forced entry. Resistant
to bolt and hand cutters, SecuraMeshTM is the extra layer of security it pays
to put in place.
SecuraMesh
TM
37
SecuraMeshTM
SecuraMesh
TM
SMMD
Product Code SMMD01 SMMD02
Description 1.2mm thick flattened mesh 1.2mm thick flattened mesh
Mesh Aperture LWD (mm) 43.3 43.3
Mesh Aperture SWD (mm) 18.0 18.0
Strand width (mm) 2.3 2.3
Strand thickness (mm) 1.1 1.1
Weight (kg/m )2
1.85 1.89
Sheet Size (mm) 2440 x 1220 2440 x 1220
Material Mild Steel Galvanised Steel
SMHD
Product Code SMHD01 SMHD02
Description 3.0mm thick flattened mesh 3.0mm thick flattened mesh
Mesh Aperture LWD (mm) 42.9 42.9
Mesh Aperture SWD (mm) 14.2 14.2
Strand width (mm) 4.6 4.6
Strand thickness (mm) 2.7 2.7
Weight (kg/m2) 8.59 8.81
Sheet Size (mm) 2440 x 1220 2440 x 1220
Material Mild Steel Galvanised Steel
SMHR
Product Code SMHR01 SMHR02
3.0mm thick mesh with 3.0mm thick mesh with
Description
raised finish raised finish
Mesh Aperture LWD (mm) 50.8 50.8
Mesh Aperture SWD (mm) 22.6 22.6
Strand width (mm) 3.1 3.1
Strand thickness (mm) 3.0 3.0
Weight (kg/m )2
6.52 6.69
Sheet Size (mm) 2440 x 1220 2440 x 1220
Material Mild Steel Galvanised Steel
SecuraMesh
TM
Applications
Popular applications
Retail Commercial & Industrial Arts Public Service
Retail outlets Record storage rooms Museums Secure units
Cashier kiosks Computer server rooms Art galleries Airport security
Pharmaceutical stores Control rooms Libraries Hospitals
Fixings: Fixed to stud with 30-38mm Fixings: Fixed to stud with 30-38mm Fixings: Suitable for both render and
galvanised staples, 30-38mm galvanised galvanised staples, 30-38mm galvanised plaster finishes. SMHR SecuraMesh™ fixed
screw-nails, or 65mm x 3.35mm bright screw-nails, or 65mm x 3.35mm bright with either suitable shot fired fixing, or
annular nails (to BS1202) and min 25mm annular nails (to BS1202) and min 25mm plug and M6 x 50mm screw and plug,
dia x 1.5mm galvanised washers fixed at dia x 1.5mm galvanised washers fixed at complete with minimum 25mm dia x
maximum 450mm centres. maximum 450mm centres. 1.5mm galvanised washers at maximum
450mm centres.
39
Wall Accessories
Wall Accessories
Catnic Wall Connectors are a simple yet effective system
for tying new masonry walls to existing walls.
Wall Connectors
Catnic wall connectors are suitable for wall thicknesses from 60mm up to
250mm and one pack contains all of the required fixings for a single wall of
2.4m high. This product is available with a choice of two different materials.
Wall Ties
Cavity wall ties provide stability to masonry walls and care
should be taken during installation to avoid the ingress of
water to the inner skin and potential failure. Wall ties should
be installed in accordance to guidance given in BSI PD 6697.
(formerly BS5628 Code of Practice for use of masonry)
• Wall Tie embedment should be at least 50mm • Density should not be less than 2.5 ties per
in both leaves square metre with density increased vertically
around openings (900mm Horizontally,
• Wall Tie should be bedded into mortar and
450mm Vertically) Cavity Wall Ties are
not placed onto dry masonry with mortar
classified in to four types as detailed in
applied around the wall tie
Table 10 of BSI PD 6697 : 2010
Type 2 Suitable for domestic dwellings and small commercial Suitable for buildings on flat sites where the
(Masonry: General purpose) buildings of a height of up to 15m above ground level, fundamental basic wind speed velocity is up to 31
made with box-form masonry walls comprising two m/s except areas where the site is at an altitude of
leaves of brickwork of similar thickness in the range 150m or more above sea level. May be adequate for
90mm to 150mm. May be suitable for cavity walls having higher altitudes and sloping sites exceeding a slope
leaves of disparate thickness or stiffness or for cladding of 1 in 20 if calculated.
walls (having none or limited horizontal spanning
capability) and for building exceeding 15m, but only
if shown to be adequate performance by calculation.
Type 4 Suitable only for masonry cavity walls, comprising two Suitable for flat sites within towns and cities
(Masonry: Light Duty) leaves of similar thickness in the range of 90mm to anywhere in the UK except in the north western
150mm, in box form domestic dwelling of up to 10m fringes of Scotland and Ireland (where fundamental
in height. Not suitable for cavity walls having disparate basic wind velocity exceeds 27 m/s) and any areas
thickness or stiffness, for cladding walls of any type or for where the site is above an altitude of 150m or more
multi-storey structures of more than three storeys. Suitable above sea level.
for internal separating cavity walls in most buildings.
41
Wall Accessories
Wall Ties
All Catnic wall ties are manufactured from high quality stainless
steel wire and strip materials to ensure that structural design
and properties are maintained throughout the life cycle of the
structure.
BB-2
Length Width Cavity width Packing
191mm 19mm 50mm Cartons of 250
BB-3
Length Width Cavity width Packing
220mm 19mm 75mm Cartons of 250
Fixings: For fixing masonry to masonry in cavity walls of domestic houses and small commercial buildings of up to three
storeys but not exceeding 15m in height. Tie density 2.4 ties/m2. Based on a design windspeed up to 56m/s.
BT 2-4
Length Width Cavity width Packing
120mm 19mm 50mm Cartons of 250
Fixings: For fixing masonry to timber framing in single and two storey dwellings up to a maximum height of 8m.
Also suitable for block to concrete applications. Tie density and windspeed refer to BBA certificate..
Wall Ties
Catnic Wall Ties are manufactured from stainless steel in accordance
with BS EN 10088-2-1.4301 (strip), BS EN 10088-3:2005 min. 18/8
composition (wire).
Double Triangular
Wall Tie
Ref: DTWT Available lengths are:
Double triangular Wall Ties are Manufactured Length Cavity Width
from Stainless Steel Wire with a diameter of 200mm 50mm - 75mm
3.3mm and Manufactured to BS EN 225mm* 76mm - 100mm
845-1:20033 and tested to BS EN 846-5:2000
Double Triangle Wall Ties DTWT are classed:
Type 2 (Masonry: General Purpose)
* Additional lengths available: 150mm,
200mm, 225mm, 225mm 250mm, 275mm,
300mm
Insulation Retainer
Ref: IRC85
Polypropylene insulation retainer,
85mm diameter.
43
Wall Accessories
Dovetail Slots
& Ties
Dovetail Slots
Ref: CDTS3000, CDTS100, CDTS150 Available lengths are:
Dovetail Channels are a cast in channel slot 3000mm - Bundles of 1 0
allowing vertical movement and horizontal 100mm - Boxes 100
restraint. Manufactured from Grade 304 150mm - Boxes 100
stainless steel and are pre-filled with
polystyrene to prevent the ingress of concrete
during the installation stage.
Dovetail Slots are used in conjunction
with safety-end ties. Can also be used with
DeBonding Sleeves (CDS) where lateral
movement is required.
Dovetail slots should be cast in-situ at a
minimum of 50mm from the edge of the wall.
Important note: Specifiers now use various wire diameters, if possible please check specification. Note: BS5628 part 2 recommends that Stainless Steel
material should be used on an external wall, including the inner leaf of a cavity wall.
44
Wall Accessories
Internal Head
Restraint
Ref: CHRF215 Available lengths are:
Head restraints are used to restrain the top Head restraint Fixing are
of a masonry free standing wall through 215mm and in box of 50 pieces
fixing to the underside of the concrete slab,
preventing sideways movement.
Head restraint fixings allow for vertical
movement to accommodate shrinkage or
thermal movement of the structural frame,
while restraining lateral loads.
Head restraint fixing are generally fixed at
450mm or 900mm dependant on the load
applied at the head of the masonry.
Head Restraint
Ref: CHR
Designed to restrain the inner leaf of a cavity Supplied in boxes of:
wall. Manufactured as two angles with 50 pieces
holes positioned to accommodate 100mm
& 140mm clock thickness. 215mm block
thickness also available.
Fixed using an MB fixing anchor (set at
torque setting 15Nm) to the underside of the
slab.
45
Wall Accessories
CLBR3 CLBR3 6
Product Ref. Product Width Wall Width Product Ref. Product Width Wall Width
CLBR3/60/2.7 60mm 100mm CLBR3.6/60/2.7 60mm 100mm
CLBR3/100/2.7 100mm 140mm CLBR3.6/100/2.7 100mm 140mm
CLBR3/150/2.7 150mm 190mm CLBR3.6/150/2.7 150mm 190mm
CLBR3/175/2.7 175mm 215mm CLBR3.6/175/2.7 175mm 215mm
3mm outer wires with 2.5mm cross wires 3.6mm outer wires with 2.5mm cross wires
CLBR5
Product Ref. Product Width Wall Width
CLBR5/60/2.7 60mm 100mm
CLBR5/100/2.7 100mm 140mm
CLBR5/150/2.7 150mm 190mm
CLBR5/175/2.7 175mm 215mm
5mm outer wires with 2.5mm cross wires
46
Wall Accessories
Movement Ties
Ref: CPET
Movement ties are used over a movement Supplied in boxes of:
joint in masonry providing restraint in one Movement Ties (CPET) are
direction and movement in the other when supplied in Galvanised and
used with a Debonding Sleeve (CDS supplied Stainless Steel Grade 304 and
separately) supplied in boxes of 250
Debonding Sleeves
Ref: CDS
Plastic Debonding Sleeves are suitable for Supplied in boxes of:
use with Plain Ended Frame Cramps and 100mm 120mm 150mm &
Movement Ties. 200mm in bags of 250
47
Technical Specification Clauses
1. Angle bead or corner bead Stainless Architrave beads shall be 6. Expanded metal lath
Galvanised Angle bead shall be manufactured manufactured in accordance with BS EN Galvanised Expanded metal lath shall be
in accordance with BS EN 103658: 2008 Parts 103658: 2008 Parts 1 & 2 using stainless steel manufactured in accordance with BS EN
1 & 2 using galvanised steel to BS EN 10346: to BS EN 10088-2-1.4301 and to suit plaster 103658: 2008 Parts 1 & 2 using galvanised
2009-DX51D+Z275 with 45mm (53mm: thickness of 10mm and 13mm without and steel to BS EN 10346: 2009-DX51D+Z275
65mm) wing size as manufactured by Catnic with return flange as manufactured by Catnic and weighing 0.90kgs per sq.metre (1.11kgs
under code reference SS3.0 (STD3.0: WW3.0). under code reference ARC10/WF/3.0/SS per sq.metre: 1.61kgs per sq.metre) as
(ARC10/WF/3.0/SS, ARC13/W0/3.0/SS, ARC13/ manufactured by Catnic under code reference
Stainless Angle bead shall be manufactured in WF/3.0/SS, ARC20/WF/3.0/SS. DL089 (DL111: DL161).
accordance with BS EN 103658: 2008 Parts 1 &
2 using stainless steel to BS EN 10088-2-1.4301 4. Movement bead Stainless Expanded metal lath shall be
with 53mm wing size as manufactured by Galvanised Movement beads shall be manufactured in accordance with BS EN
Catnic under code reference STD3.0SS. manufactured in accordance with BS EN 103658: 2008 Parts 1 & 2 using stainless steel to
103658: 2008 Parts 1 & 2 using galvanised steel BS EN 10088-2-1.4301 and weighing 1.11kgs
2. Plasterstop or casing bead to BS EN 10346: 2009-DX51D+Z275 and to per sq.metre as manufactured by Catnic under
Galvanised Plasterstops shall be manufactured suit plaster thickness of 12mm (15mm: 18mm: code reference DL111S.
in accordance with BS EN 103658: 2008 21mm) as manufactured by Catnic under code
Parts 1 & 2 using galvanised steel to BS EN reference MB10/3.0 (MB13/3.0: MB16/3.0: 7. Rib Lath
10327-DX51D+Z275 and to suit plaster MB19/3.0). Galvanised Rib Lath shall be manufactured
thickness of 10mm (13mm: 16mm: 19mm) as in accordance with BS EN 103658: 2008 Parts
manufactured by Catnic under code reference Stainless Movement beads shall be 1 & 2 using galvanised steel to BS EN 10346:
PS10/3.0 (PS13/3.0:PS16/3.0: PS19/3.0). manufactured in accordance with BS EN 2009-DX51D+Z275 with 10mm ribs at 100mm
103658: 2008 Parts 1 & 2 using stainless steel centres and weighing 1.48kgs per sq.metre
Stainless Plasterstops shall be manufactured in to BS EN 10088-2-1.4301 and to suit plaster (1.84kgs per sq.metre: 2.22 per sq.metre) as
accordance with BS EN 103658: 2008 Parts 1 & thickness of 12mm (15mm: 18mm: 21mm) as manufactured by Catnic under code reference
2 using stainless steel to BS EN 10088-2-1.4301 manufactured by Catnic under code reference RIB148 (RIB184: RIB222).
and to suit plaster thickness of 10mm (13mm: MB10/3.0/SS (MB13/3.0/SS: MB16/3.0/SS:
16mm: 19mm) as manufactured by Catnic MB19/3.0/SS). Stainless Rib Lath shall be manufactured in
under code reference PS10/3.0/SS (PS13/3.0/ accordance with BS EN 103658: 2008 Parts
SS: PS16/3.0/SS: PS19/3.0/SS). 5. Renderstop 1 & using stainless steel to BS EN 10088-2-
Galvanised Renderstops shall be manufactured 1.4301 with 10mm ribs at 100mm centres and
3. Architrave beads in accordance with BS EN 103658: 2008 Parts weighing 1.48kgs per sq.metre (1.84kgs per
Galvanised Architrave beads shall be 1 & 2 using galvanised steel to BS EN 10346: sq.metre) as manufactured by Catnic under
manufactured in accordance with BS EN 2009-DX51D+Z275 as manufactured by Catnic code reference RIB148/SS (RIB184/SS).
103658: 2008 Parts 1 & 2 using galvanised steel under code reference RS3.0.
to BS EN 10346: 2009-DX51D+Z275 and to suit 8. Steel lintels
plaster thickness of 10mm and 13mm without Stainless Renderstops shall be manufactured Steel lintels shall be manufactured
and with return flange as manufactured in accordance with BS EN 103658: 2008 Parts in accordance with BS EN 845: 2013
by Catnic under code reference ARC10/ 1 & 2 using stainless steel to BS EN 10088-2- using galvanised steel to BS EN 10346:
WF/3.0 (ARC13/WF/3.0: ARC20/WF/3.0) or 1.4301 as manufactured by Catnic under code 2009-DX51D+Z275 and coated with a
ARC10WO/3.0 (ARC13/WO/3.0). reference RS/3.0/SS. thermosetting polyester powder coating as
manufactured by Catnic.
49
CATNIC WORLD
Catnic Distributors
51
www.catnic.com
Catnic
Pontypandy Industrial Estate
Caerphilly
CF83 3GL
T: 029 2033 7900
F: 029 2086 7796
www.catnic.com
English version
52