RADspeed Pro Style Edition Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

C501-E052

RADspeed Pro style edition


Manual
RADspeed Pro style edition
Manual

High Productivity and Reliability: Superb Performance & Efficiency


Hallmarks of Shimadzu X-Ray Systems! MC Type MF Type
A ceiling-mounted X-ray tube system with a wide range The system is for compact floor-mounted tube support
of movement allows excellent imaging, technique installations.
flexibility and easy access to the patient. Designed to exacting specifications, the system delivers
This enhanced flexibility is ideal for imaging centers high-performance, high-quality, and cost-effective
that demand high productivity to meet fast patient operation in a superior general radiographic system.
throughput.

Space Saving Concept Space Saving Concept


The compact, space-saving high voltage generator provides more working The compact, space-saving high-frequency generator and tube support
space as well as a flexible layout. A ceiling-mounted X-ray tube further provide greater working space and flexible layout.
increases the spatial area around the patient on a Bucky table or trolley.

With over a century of experience in manufacturing X-ray apparatus,

Shimadzu's expertise in X-ray systems is well recognized.

For years, Shimadzu's X-ray products have been associated with legendary reliability,

cost-effectiveness and quality in the medical industry.

Shimadzu's general radiographic systems are imbued with the Shimadzu heritage.

Additionally, our general radiographic system features state-of-the-art technology that enhances productivity,

user-operability, patient comfort and safety.

2 3
More Possibility to Make Your System
Operation Even Easier

Patient Care Concept Generator Equipped with Free Rotation around the Support Axis Synchronized Vertical Movements of
Illumination Functions OPTION High-Frequency Inverter Technology Rotation around the vertical axis is enabled, by activating the X-Ray Tube Unit and Bucky Unit OPTION

rotation-switch, which is located on the control panel. The lock can be set
This advanced feature allows the X-ray generator to provide solutions to the The RADspeed Pro general radiographic system is equipped with an in any position, allowing precise, accurate positioning. The focal point of the X-ray tube unit moves up and down in
following problems, allowing the operator to concentrate on patient care: advanced-level generator designed using state-of-the-art high-frequency conjunction with the vertical positioning of the X-ray Bucky stand and
• Infant and frail elderly patients who need constant attention inverter technology, which produces sharp and high-contrast X-ray X-ray Bucky table. This allows the operator to attend the patient in a
• Split-second timing is required for patients who have difficulty holding images. User-friendly sequential multi-directional radiography functions standing position while positioning the equipment.
their breath. allow the operator to register and then utilize up to 7 sequential preset For a table study, the X-ray tube automatically moves to a preset SID,
• Quick positioning and image capture when required memory parameters. enabling accurate and fast positioning.

50 kHz High-Frequency Generator

7
Up to
Sequential Multi-Directional
Radiography Exposure Presets

Heavy Duty Height-Adjustable Bucky


New energy saving collimator with a Table with 4-Way Floating Tabletop
bright irradiation field The Bucky table BK-120MK can easily lift up to 200 kg. Patient positioning
LEDs have been adopted as the is made easier with the extremely smooth-moving tabletop. The unit's
l i g h t s o u rc e t o i n d i c a t e t h e minimum height of 535 mm makes it easy for old and young patients alike Automatic synchronization
irradiation field. This reduces to get on and off the examination table. The BK-120MK includes a Bucky
power consumption while unit with a cassette tray and grid.
improving brightness levels and
durability.

The hand switch


also lights up to
indicate status.

Orderly Cable Management OPTION

Shimadzu provides a tractable cable management system along the ceiling


Illumination Color and Alarm Sound When rails that supports smooth positioning.
FPD Rotation Tray OPTION

Preparation for Exposure Is Complete The FPD tray can be rotated 90 degree to change the orientation of FPD.

Automatically follows changes in table height


(BK-120MK only)

Using Bucky stand Using Bucky table

4 5
Wide Range of Choices to Meet Your Needs
X-Ray Tube Support Bucky Tables Bucky Stand Collimator
CH-200M BK-200 BR-120M R-20J
Celing-mounted tube support Heavy duty Bucky table A Bucky unit height of just 552 mm Manual Collimator
Longitudinal travel: 2950 up to 4450 mm (selectable) Height range: 535 mm to 850 mm (Vertical movement is not synchronized with CH-200M)
and a convenient lower cutout Max. 430 mm × 430 mm irradiation field at 100 cm SID
Lateral travel: 1400 up to 2700 mm (selectable) Max. lifting weight: 295 kg make this unit both compact and Light switch with automatic off function
Vertical travel: 1600 mm Tabletop floating range: 1150 mm (long.), 250 mm (transverse) convenient for patients. Accessory rails
Tube angulation around the horizontal axis: +120° to -180° Bucky unit movement range: 400 mm LED lamp
Vertical rotation: ±180° Grid is removable Vertical travel range: 1500 mm
Vertical tracking unit (option) FPD rotation tray (option) Grid is removable
Orderly cable management (option) FPD rotation tray (option)

BK-120MK X-Ray High Voltage Generators


Height-adjustable Bucky table
Height range: 535 mm to 850 mm
Max. lifting weight: 200 kg

FH Series Tabletop floating range: 1100 mm (long.), 250 mm (transverse)


Bucky unit movement range: 380 mm
FH-20HR: Floor-mounted tube support FPD rotation tray (option)
(2 rails: both on floor)

FH-21HR: Floor/Wall or Floor/


Ceiling-mounted tube support
(2 rails: one on floor, other on ceiling or wall)
Longitudinal travel: 2500 mm
Lateral travel (telescopic arm): 250 mm
Vertical travel: 1550 mm
Tube angulation around the horizontal axis: ±180°continuous
Column rotation for lateral tabletop radiography: ±90°

BK-12HK High Grade Type Standard Type


Bucky table Large capacity and high-frequency inverter High-frequency inverter
Max. allowable load : 200kg
Exposure timing indicated by light and sound Exposure timing indicated by light and sound (option)
Tabletop floating range: 1100 mm (long.), 250 mm (transverse) All APR units include a sharp, easy-to-read color LCD A large-character readout LED and hybrid keys
Tabletop height: 700 mm touch panel. allow easy, one-touch setting of APR exposure
Bucky unit movement range: 380 mm
Quick setup with jog dials and Up/Down buttons parameters.
Grid is removable
FPD rotation tray (option)
Model UD150B-40 UD150V-40 UD150L-40 Model UD150L-40E UD150L-40F
Max. output power (kW) 80 65 50 Max. output power (kW) 50 (32 kW /single 200 V power supply)
Tube voltage range (kV) 40 to 150 40 to 150 40 to 150 Tube voltage range (kV) 40 to 150
Tube current (mA@100 kV) 800 650 500 Tube current (mA@100 kV) 500 (320)
(mA@80 kV) 1000 800 630 (mA@80 kV) 630 (400)
Exposure time (sec) 0.001 to 10 Exposure time (sec) 0.001 to 10
Anatomical programs (APR) 800 (adjustable layout) Anatomical programs (APR) 245
Panel operation Color LCD + Touch panel Panel operation Membrane keys

FH-20HR FH-21HR Number of X-ray tubes connectable 1 2

6 7
Founded in 1875, Shimadzu Corporation, a leader in the development of
advanced technologies, has a distinguished history of innovation built on the
foundation of contributing to society through science and technology. We
maintain a global network of sales, service, technical support and applications
centers on six continents, and have established long-term relationships with a
host of highly trained distributors located in over 100 countries. For information
about Shimadzu, and to contact your local office, please visit our website at Shimadzu Corporation Medical Systems Division has been certified by TÜV
www.shimadzu.com Rheinland as a manufacturer of medical systems in compliance with ISO9001:2015
Quality Management Systems and ISO13485:2016 Medical Devices
Quality Management Systems.

Remarks:
• Every value in this catalogue is a standard value, and it may vary a little from the
actual at each site.
• The appearances and specifications are subject to change for reasons of
improvement without notice.
• Items and components in the photos may include optional items. Please confirm
Headquarters with your sales representative for details.
1, Nishinokyo-Kuwabara-cho, Nakagyo-ku, Kyoto 604-8511, Japan • Certain configurations may not be available pending regulatory clearance.
https://www.shimadzu.com/med/ Contact your Shimadzu representative for information on specific configurations.
• Before operating this system, you should first thoroughly review the Instruction
Manual.

Printed in Japan 6032-01905-20AMF