8200vector V040 Safe Standstill

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Technical data

3 Technical data

3.1 Safety relay - Technical data/ wiring


The safety relay is connected to the front of the controller by means of the 4-pole plug X11. The safety
relay is equipped with a freewheeling diode and a reverse voltage protection diode.
Wiring
DC =

31
K
32
+24V

K
33
34
X3.1
X3.1 34 33 K32 K31
+

KSR

+5V

IGBT
8200 vector
Terminal assignment Data
33 Reference ppotential for the Safetyy relayy Coil voltage at +40°C DC +24 V (+19.5 ... 36 V)
safety
f shutdown
h d iinput Coil current at 24 V DC 30 mA
Test voltage - contact → coil AC 1500 Vrms for 1 min
34 Safetyy shutdown input
p Test voltage - contact → contact AC 1500 Vrms for 1 min
Electrical service life at rated load ~ 107 operating cycles
Mechanical service life ~ 107 operating cycles
K31 Feedback contact Switching voltage DC 24 V
Feedback contact
K32 Continuous current 5 ... 700 mA

Warning!
The electrical reference point for the safety relay coil must be connected to the PE conductor
system (DIN EN 60204-1 paragraph 9.4.3)!
This is the only way to protect the unit from earth faults.

4 ba_UOMMbkJsMQM NKM L
Installation

4 Installation

4.1 Circuit for “Safe standstill with safety relay”

The example shows the minimum wiring of the components. This ensures the troublefree operation
of the “Safe standstill” function with the 8200 vector V040 frequency inverter. (Note: A standard or
application I/O is necessary)

E m e rg e n c y o ff P r o te c tio n d o o r m o n ito r in g S ta rt-S to p m o m e n ta ry c o n ta c t p u s h b u tto n

S 4

S 3 S 1 S 2
E m e rg e n c y o ff O F F O N

E m e rg e n c y o ff P r o te c tio n d o o r K 3 K 4 K 3
tA tA
s w itc h in g u n it
1
s w itc h in g u n it 2

A 1 A 2

K 2 a

L 1
L 2
L 3
K 4 C W C C W K 4 K 2 a K 3
r o ta tio n r o ta tio n
F 1 ..F 3

K 4

+ 2 4 V
0 V

X 1 1 K 3 2 K 3 1 3 4 3 3 E 3 E 4 2 8 3 9 X 3
Q S P R F R G N D
K S R
C W C C W
r o ta tio n r o ta tio n

8 2 0 0 v e c to r
E 8 2 Z A F S /
V 0 4 0 IG B T E 8 2 Z A F A
A 3

Fig. 1 Minimum wiring for 8200 vector V040 frequency inverter with safety relay
according to EN 954-1 control category 3 and EN 1037, stop category 1 to EN 60204-1

4.1.1 Description
For a circuit with a safety relay for emergency off and door lock follow EN 954-1 control category
3 and EN 1037. The circuit in Fig. 1 shows a stop function of stop category 1 to EN 60204-1:
• The circuits for emergency off and door lock are two-channel circuits protected against short
circuits between signal cable. The integrated switching devices are equipped with positively
driven contacts.
• The 24 V DC supply for the start/stop button (S1 “OFF”, S2 “ON”) flows through the contacts
of A1 (emergency off) and A2 (protection door).
• A1 and A2 and the relay K3 have an additive effect on the input “Quick-Stop” (QSP) of the
controller (A3) via terminal E3 (CW rotation) and terminal E4 (CCW rotation).
• The following units must be integrated to ensure a reversal of direction of rotation:
• Opening the protection door during operation results in a slow dropping of the mains
contactor (K4) and thus the power supply for the drive controller. This is not the case if the
feedback contact K31 - K32 of the safety relay (KSR) indicates activation of the external pulse
inhibit via the plug X3.1 in the drive controller (2. switch-off circuit).