Revealing The Secrets of The Brain: Bittium Neurone™ Tesla

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Revealing

the Secrets
of the Brain
Bittium NeurOne™ Tesla
Bittium Connectivity
NeurOne™ to be trusted. Bittium is a trusted Nordic company with

Tesla Bittium NeurOne™ Tesla neuroscience


measurement system offers more accuracy,
cleaner signal, faster sampling, modular
over 30 years of expertise in advanced radio
communication technologies and biosignal
processing.
solution and more flexibility and expandability
• DC EEG/ERP
by utilizing the latest advances in digital Bittium provides reliable and secure solutions
• TMS EEG
• fMRI-EEG signal processing. for connectivity, tactical communications and
• 40 to 1200 channels measuring and monitoring of biosignals.
• Up to 30 persons
Bittium NeurOne™ Tesla is a versatile system and
• 24 bit resolution
it can be used widely in different neuroscience and
• DC-3500 Hz Bittium offers medical technology in biosignals measuring
psychological applications. Bittium NeurOne™ Tesla is
and monitoring for cardiology, neurophysiology, neuroscience,
especially designed for use together with transcranial
rehabilitation, occupational health and sports medicine.
magnetic stimulators having extremely large dynamic
Bittium develops cutting-edge technology for cardiac
range and special reduction technology to remove
applications such as holtering, cardiac telemetry and
magnetic artifacts in short latencies. Advanced amplifier
cardiac rehabilitation, as well as high-end EEG solutions
design enables using both AC and DC recording modes
Medical Products for TMS-EEG and fMRI-EEG applications, remote monitoring
the way you want. Innovative Tesla MRI amplifier
Bittium Faros™ EEG applications, and emergency EEG applications. The
brings MRI compatibility to NeurOne™.
Bittium Cardiac Rehabilitation System™ products meet European Union medical CE requirements
Bittium NeurOne™ and the company’s quality system meets ISO 9001,
Bittium BrainStatus™ ISO 13485 directive MDD 93/42/EEC requirements.

Applications Advanced Technology Tesla Station Real-Time Digital Out

NeurOne™ real-time
NeurOne™ EEG Ethernet/UDP
digital out

40 ch 40 ch 40 ch

• 24-bit resolution Stimulation EEG Data Analysis


Syncbox system with • Wide band DC-3500 Hz
2 x 120 channels • Large dynamic range +/- 430 mV
• AC and DC measurement modes
switchable channel by channel
40 ch 40 ch 40 ch • 40-channel amplifiers having 32 EEG New add-on card to NeurOne™ Main unit,
and 8 bipolar channels upgrades available to existing systems!
• EEG/EP • 40 to 160 channels in basic version • Ethernet UDP
• ERP research • Real-time Ethernet/UDP output • Protocol based output channels selection
• EEG + TMS research • EEG sample synchronized triggering (see picture • 24 bit measurement data output with
• EMG research with many channels for actual measurement – hand held coil) Tesla station brings easily movable trolley, constant delivery rate of 100, 250, 500, 1000,
• Group studies (up to 30 amplifiers • Windows 64-bit software with online built in battery (110 Ah) and a 320 channels 2000, 3000, 4000 and 5000 Hz
and digital video) averaging and TMS artifact correction system with color coded cap connectors • Performance scales up when using
• fMRI-EEG research (optional) • Active or passive electrodes into one package. several Main Units
Copyright © 2018 Bittium. All rights reserved.
Specifications Designed & Manufactured in Finland

Description: Powerful and Versatile Electroencephalography Research system


Monopolar Channels: 32 channels per amplifier (full system 128) – expandable to 960 with Brainstorm technology
Bipolar Channels: 8 channels per amplifier (full system 32) – expandable to 240 with Brainstorm technology
High level Channels: Max. 8 per amplifier, connected through isolated analog adapter (to bipolar channels), range ± 5V or ± 10V (settable)
Digital (TTL) Inputs: 2 isolated trigger in/out lines, 8-bit unisolated trigger in (with Syncbox up to 10x)

Sampling method: All channels sampled simultaneously


Available sampling rates:
NeurOne™ NeurOne™ Brainstorm technology with Syncbox
• 250 Hz, 500 Hz, 1000 Hz, 2000 Hz, • 80 kHz (max. 10 x 20 channels, one amp/main unit),
5000 Hz, 10 kHz (160 ch) 40 kHz (max. 10 x 40 channels – one amp/main unit,
• 20 kHz (up to 80 ch), 40 kHz 20 kHz (max. 1200 channels)
(up to 40 ch), 80 kHz (up to 20 ch) • 250 Hz, 500 Hz, 1000 Hz, 2000 Hz, 5000 Hz, 10 kHz
A/D Resolution: 24 bit
Input Impedance: > 1 GΩ
CMRR: Typically 106 dB

DC Mode AC Mode
Bandwidth: LP: 3.5 kHz HP: 0,16 Hz, LP: 3.5 kHz
Full scale Input Range: ± 430 mV ± 86 mV
System Gain: 10 50
Sensitivity: 51 nV/bit 10.2 nV/bit
Noise: <0.8 µV RMS (0–200 Hz) <0.6 µV RMS (0.16–200 Hz)
<2.0 µV RMS (DC-3500 Hz) < 1.5 µV RMS (0.16–3500 Hz)
Transient Artifact Protection: High Speed Switch (settable)
Mute: Mute for AC/DC stage (settable)
Impedance measurement: 1 kΩ to 200 kΩ

Connections: Tesla amplifier Power 6V, Fibers, Cap connection (40 ch), Bipolar/Module (8 ch incl. power for modules ± 5V max. 1000 mA)
Main unit - Black Power 12V, Ethernet, Fibers to Headbox (x 4), Trig In/Out (x 2), 8-bit Trig, Audio Out (2 ch) *
Main unit - High Power 12V, Ethernet, SPI, Isolated Headbox Power (x 4), Fibers to Headbox (x 4),
Serial Port (x 3), Trig In/Out (x 2), 8-bit Trig, Analog Out (16 ch), Audio Out (2 ch) *
Syncbox Master Trig In and Trig button, External Clock In input (BNC or fiber), 10 fiber connectors (1 Master, 9 Slave)
* optional real-time Ethernet/UDP digital out
Amplifier size/color: 16 x 12 x 8 cm, 1.260 kg, Beige (Tesla), Black (Tesla MRI)
Main unit size, black: 33 x 27 x 7 cm, 2.9 kg
Main unit size, high: 33 x 27 x 12 cm, 3.6 kg

NeurOne™ software: 64-bit Windows, optional BCI2000 and SIMULINK driver, video. Readers for BESA and Matlab as well
as EEGLAB plug-in available for free
System Classification: MDD class lla. Type BF applied part
Safety Specification: EN 60601-1, EN 60601-1-1, EN 60601-1-2, EN 60601-1-4, EN 60601-2-26
Warranty: 2 years

Users of Bittium NeurOne™ in the USA please note:


Caution – For research use only. Not for use in diagnostic procedures. Device may be used for non-clinical laboratory research.

FOR MORE INFORMATION, PLEASE CONTACT:


[email protected] / www.bittium.com