EM-PME375-T200: Electric Machine, Permanent Magnet External

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Data Sheet

EM-PME375-T200
Electric machine, permanent magnet external
FEATURES
• Synchronous Reluctance assisted Permanent
Magnet (SRPM) technology
• Extremely compact and robust structure
• Highest efficiency throughout the operation range
on the market (~96 %)
• Liquid cooled with plain water or water/glycol
mixture
• Low coolant flow required
• Allowed coolant temperature up to +65°C GENERAL
• Up to IP65 enclosure class to maximize reliability The machine is developed especially for demanding
• Multiple mounting possibilities applications. The design of these machines makes them
smaller, lighter and more efficient than conventional
products on the market.
GENERATOR SPECIFIC FEATURES The machine is designed to be shorter than normal motors
for applications where axial length is crucial parameter. The
• Standard SAE flange mounting to match the diesel machine is designed to be connected directly to the ICE
engine connection flywheel housing with part of the motor being inside the
flywheel housing further shortening the length of the motor.
• Wide selection of speed ratings allowing the
generator to be selected to customer specific
applications with various voltage requirements TYPICAL APPLICATIONS
• Generator for diesel-electric/ serial hybrid
• Can be also used as starter motor for the ICE
applications
• Traction/propulsion motor
MOTOR SPECIFIC FEATURES
• Generator/Motor for parallel hybrid applications
• Extended speed and torque capabilities compared
to standard PM motors from Danfoss reluctance
assisted permanent magnet motor technology
• Motor structure is designed to be able to produce
high starting torques: EM-PME motor can produce
instantly full to a non-moving axle
• Optimized speed range to meet the most common
gear ratios used in heavy mobile machinery

1 | © Danfoss | October 2019 AI312651107941en-000102


Data Sheet
EM-PME375-T200

SPECIFICATIONS
General electrical properties Minimum cooling 20 l/min
liquid flow
Nominal voltage (line 500 VAC
to line) Pressure loss 0.3 bar with 20 l/min
(+25°C coolant)
Voltage stress IEC 60034-25, Curve A: Without
filters for motors up to 500 VAC Cooling liquid +65°C (Derating required if
temperature max exceeded)
Nominal efficiency 96 %
Temperature rating
Pole pair number 10
Insulation class F (155°C)
Power supply Inverter fed. (IEC 60034-1)
Temperature rise 85°C
Minimum inverter 8 kHz (IEC 60034-1)
switching frequency
Maximum winding 150°C
Basic information temperature
Machine type Synchronous reluctance assisted Nominal ambient 65°C
permanent magnet temperature
(IEC 60034-1)
Mounting IM 3001 (Flange)
(IEC 60034-7) Min. ambient -40°C
temperature
Standard Flange D-end SAE 3, transmission housing
(SAE J617) Nominal altitude 1000 m
(IEC 60034-1)
Standard rotation Clockwise (both directions
direction possible) Connections
Protection class Up to IP65 Coolant connection 2 x G1/2 bores
(IEC 60034-5)
Duty type S9 HV cables 3 x 50 mm2 max.
(IEC 60034-1)
HV cable connector 3x AMPHENOL
Standard color Dark grey RAL7024 powder
HVBI005R10AMHARD
coating
HV cable mating 3 x AMPHENOL HVBI-7-05R10-XFC-
Mechanical connector XXXX-FG/PC (straight plug)
3x AMPHENOL HVBI-9-05R10-XFC-
Total weight 85 kg (no options) XXXX-FG/PC (right angle plug)
(check the exact codes form
Moment of inertia 0.77 kgm² connector manufacturer)
Rotating mass 27 kg HV cable Recommended H+S Radox
screened cable
Dimensions LV connector 12 pin TE HDSCS

Length (frame) 66 mm LV connecter type TE 1-1564520-1


Diameter (frame) 451 mm LV connector pin type Gold plated
Total length (frame + 215.6 mm LV mating connector TE 1-1703639-1
shaft) type
Cooling LV mating connector TE 1241380-2 (Gold plated)
pin type
Cooling liquid Plain water with appropriate
corrosive inhibitor (max. 50 % LV connector pin See table below
corrosive inhibitor) configuration
Cooling liquid Ethylene glycol Glysantin
corrosive inhibitor type G48 recommended
Cooling method IC 9S7Y7 (Liquid cooled, external
(IEC 60034-6) heat exchanger)

2 | © Danfoss | October 2019 AI312651107941en-000102


Data Sheet
EM-PME375-T200

Table 1 Pin configuration of LV-connector


PIN Description
1 Resolver, RES_COSN
2 Resolver, RES_SINN
3 Resolver, EXCN
4 Temperature, PT100, Windings
5 Temperature, PT100, Windings
6 Temperature, PT100, Windings
7 Resolver, RES_COSP
8 Resolver, RES_SINP
9 Resolver, EXCP
10 Temperature, PT100, Windings GND
11 Temperature, PT100, Windings GND
12 Temperature, PT100, Windings GND

PRESSURE LOSS VS COOLANT FLOW


0,7
0,6
Pressure loss [bar]

0,5
0,4
0,3
0,2
0,1
0
0 5 10 15 20 25 30 35
Volume flow [l/min]
chine
Picture 1 Pressure loss vs coolant flow

MOTORS
Coolant temperature +65°C Coolant temperature +40°C Coolant temperature +40 / +65°C
Cont. Cont. Nom. Nom. Nom.
Type Cont. Torque Cont. Power Max. speed Peak torque
Torque Power Current Current speed
[Nm] [kW] [rpm] [Nm]
[Nm] [kW] [A] [A] [rpm]
EM-PME375-T200-1500 191 30 37.5 191 30 38 1500 3000 800
EM-PME375-T200-1800 180 36 45 210 40 53 1800 3600 800
EM-PME375-T200-2300 184 48 60 208 50 68 2300 4000 800
EM-PME375-T200-2600 172 50 63 200 54 73 2600 4000 800
(* Peak torque achieved with 1 (350A) inverter
(** Peak torque achieved with 2 (350A) inverter

GENERATORS
Coolant temperature +65°C Coolant temperature +40°C Coolant temperature +40 / +65°C
Volt/
Apparent Cont. Nom. Apparent Nom. Nom. Nom.
Type Cont. Power Power speed
power power Current power Current speed Freq.
[kW] factor ratio
[kVA] [kW] [A] [kVA] [A] [rpm] [Hz]
[V/rpm]
EM-PME375-T200-1500 32 31 36.5 31 31 36 1575 262.5 0.99 0.367
EM-PME375-T200-1800 38 37 44 44 42 51 1890 315.0 0.96 0.298
EM-PME375-T200-2300 50 49 58 57 55 65 2415 402.5 0.96 0.229
EM-PME375-T200-2600 53 52 62 61 58 71 2739 456.5 0.95 0.206
(*** Back EMF for cold (20 °C) generator

3 | © Danfoss | October 2019 AI312651107941en-000102


Data Sheet
EM-PME375-T200

Integrated machine is commonly connected directly to the diesel engine flywheel housing. In such application part of the motor
is inside the diesel engine. Exploded view of this kind of application is shown below.

Picture 2 Integrated machine connected to diesel engine flywheel housing

4 | © Danfoss | October 2019 AI312651107941en-000102


Data Sheet
EM-PME375-T200

PRODUCT CODE AND OPTIONS


Use product code including all needed options for ordering. Standard options do not need to be listed in the code as they are
selected by default if a non-standard option is not selected.

Product code Description


EM-PME375-T200-1800 Standard unit with standard options
EM-PME375-T200-1800+TEMP4 Standard otherwise but with additional temperature sensors (6 pcs total)
Table 2 Product code examples

s = standard
o = option

Standard
Description
Variant code
High voltage connector High voltage plug-in connectors for 50 One plug-in connector per phase for 50
* s
mm2 cables mm2 cable
High voltage plug-in connectors for 35 One plug-in connector per phase for 35
+HVC1 o
mm2 cables mm2 cable
Rotation sensor * None s No resolver
+RES1 Resolver o In-built non contacting resolver, 5-pole pair

Winding temperature
sensors * Temperature surveillance s 3 x PT100 (two wire) in windings

+TEMP4 Redundant temperature surveillance o 6 x PT100 (two wire) in windings


Table 3 Option list

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its
products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in
specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are
trademarks of Danfoss A/S. All rights reserved.

5 | © Danfoss | October 2019 AI312651107941en-000102