HOBT - AMX-220 Service Manual (1) - Compressed

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

www.dl-services.com spare.parts@dl-services.

com

SERVICE TRAINING CENTER HOBART GmbH


An ITW-Company

Service Manual EFFICIENT – RELIABLE – INNOVATIVE

AMX(X) / AUXX
SERIES - MARINE VERSION CV
STARTING FROM SERIAL NO 8658 0001

This document is produced for internal use only.


The detailed settings and servicing must be carried out
by service technicians qualified by HOBART.
Reproduction of this document is prohibited without the
written permission of Hobart GmbH.

ISSUE: 2010-03 © HOBART GmbH, Service Training Center


Before Maintenance Please Read SAFETY Instructions 1 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

CONTENTS
1. MACHINE DIMENSIONS .................................................................................................................................. 3
2. INSTALLATION . ............................................................................................................................................... 4
2.1 ELECTRICAL CONNECTION ................................................................................................................ 4
2.2 WATER CONNECTION ......................................................................................................................... 4
2.3 DRAIN CONNECTION ........................................................................................................................... 4
3. SMARTTRONIC CONTROLS ........................................................................................................................... 5
3.1 AMX / AUX SERIES – PROFI ............................................................................................................... 5
4. FIRST RUN / CUSTOMER MENU .................................................................................................................... 6
5. HYDRAULIC SCHEMATICS ............................................................................................................................. 7
5.1 LEGEND OF COMPONENTS . .............................................................................................................. 7
5.2 AMX(S) / AMXX(S) / AUXX(S) .............................................................................................................. 8
5.3 AMXT / AUXXT . ..................................................................................................................................... 8
6. FILLING . ........................................................................................................................................................... 9
6.1 IMPELLER SWITCH .............................................................................................................................. 9
6.2 PRESSURE TRANSMITTER B3 / B4 .................................................................................................. 10
6.3 DOSING EQUIPMENT . ...................................................................................................................... 11
6.3.1 HOBART DETERGENT / RINSE AID DISPENSER - (OPTIONAL) ..................................................... 11
6.3.2 ADJUSTMENT OF CHEMICALS DEFICIENCY SENSORS - (OPTIONAL) ........................................ 12
6.4 BOOSTER / TANK / TEMPERATURE PROBES . ................................................................................ 13
7. WASHING ....................................................................................................................................................... 14
7.1 WASH PUMP AND STRAINER SYSTEM ............................................................................................ 14
7.1.1 FUNCTION: . ........................................................................................................................................ 14
7.1.2 TECHNICAL DATA ............................................................................................................................... 15
7.1.3 CHECKING THE DIRECTION OF ROTATION .................................................................................... 15
7.2 RINSE PUMP ....................................................................................................................................... 15
8. HOOD – DETAILS . ......................................................................................................................................... 16
9. ELECTRONIC CONTROL .............................................................................................................................. 17
9.1 KEY COMBINATIONS . ........................................................................................................................ 17
9.1.1 BASIC OPERATION / CUSTOMER SETTINGS .................................................................................. 17
9.1.2 SERVICE MENU .................................................................................................................................. 18
9.1.3 PROGRAMMING / MODIFICATION OF BASIC DATA / SOFTENER TEST ........................................ 19
9.2 PRINTED CIRCUIT BOARDS . ............................................................................................................ 20
9.2.1 MAIN BOARD ...................................................................................................................................... 20
9.2.2 EXTENSION BOARD A3 ..................................................................................................................... 21
9.3 COUNTER FUNCTIONS ..................................................................................................................... 22
10. FAULTS ........................................................................................................................................................... 23
10.1 UNCRITICAL FAULTS ......................................................................................................................... 23
10.2 CRITICAL FAULTS . ............................................................................................................................. 24
10.3 OTHER INDICATIONS . ....................................................................................................................... 25

Page 2 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 2 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

1. MACHINE DIMENSIONS
758

AMX / AMXX AMXT


AUXX AUXXT
440

440
1995*

1995*
1510*

1510*
860*

860*
200*

200*
107

107
635

815

635

815
1268

1390

107
635

870
758

AMXR / AMXXR AUXXL


AUXXR
540

2195*
440

1995*

1610*
1510*

40
860*

860*

200*
110*

107
107
635

815

635

882

107 107
635 635

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 3


Before Maintenance Please Read SAFETY Instructions 3 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

2. INSTALLATION
2.1 ELECTRICAL CONNECTION
The machines will be supplied as standard with cable H07RN-F 4G 2.5 mm2 (cable length approx. 2.5 m
from cable gland).
According to EN 60 335 the appliance must be connected to an equipotential conductor.
The connecting screw ( ) is located beside the cable inlet.

2.2 WATER CONNECTION


The machines must be operated with potable water.
For water with an extremely high mineral content an external demineralisation is strongly
recommended.
Ideal conductivity value for washware made of stainless steel 80 μS/cm, for glasses 100 µS/cm and for
dishes 200 to 400 μS/cm

The machine should be connected to soft and if possible warm water (up to 3 °dh = 0.5 mmol/l, max. 60°C).

Line flow pressure 0.5 – 10 bar.


Important: the line flow pressure must not be less than 0.5 bar.
If the line flow pressure is above 10 bars provide pressure reducer at source.

Connect the union nut "A" (3/4") of the water supply hose to the site shut off valve.
Do not kink or cut the supply hose. Eventually needed extension has to be provided with a suitable
pressure hose (e.g. 00-324088-001).

2.3 DRAIN CONNECTION


Connection between machine and site
drain must not exceed the specified height
of max. 0.75 m.

Do not kink the drain hose.


Do not place the drain hose loosely on the
floor (the hose could be rubbed through).
Fix it at site!
max. 750 mm

Page 4 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 4 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

3. SMARTTRONIC CONTROLS
3.1 AMX / AUX SERIES – PROFI
8 6

4 2 3 1 9 7 5

1 Machine ON/OFF Pushing this button switches the dishwasher on.


DRAIN By pushing and holding (3 s) this button, the drain and self cleaning cycle starts.
Once the drain cycle has completed the machine switches off automatically.
After switch off, the machine is not voltage free!
The button illuminates to indicate the mode of the machine:
GREEN (flashing) = machine fills and starts heating
GREEN (permanent) = ready for operation
BLUE (permanent) = wash cycle is running (basic data U02)
BLUE (flashing) = machine draining / switch-off
RED (permanent) = critical failure (machine type setting U01)
GREEN/RED (alternate flashing) = noncritical failure
BLUE/RED (alternate flashing) = negative pressure failure

By pushing this button it is possible to select between different preset


2 Program button programs, according to model and equipment.
The program no. will be shown in the upper Display.
3 High pressure / AUXX(L/T) models only: Activation of high pressure cleaning.
Service button Never use for cleaning glasses and light dishes (breakage) !

In case of operating error or faults, it is possible to switch-off the machine


4 Stop button immediately without drain cycle, by pushing this button.
After switch off, the machine is not voltage free!
5 Display Temperature indication Wash (°F)

6 Display Temperature indication Final Rinse (°F)

Indicates the need for regeneration salt to be added.


7 Salt required
(Only with built-in softener.) - not active
8 Detergent /
Indicates detergent (CH1) or rinse aid (CH2) deficiency. - not active
Rinse aid indicator
This symbol indicates that the dishwasher has developed a fault. In the rinse
9 Service indicator
temperature display appears a code (see page 23 to 25).

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 5


Before Maintenance Please Read SAFETY Instructions 5 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

4. FIRST RUN / CUSTOMER MENU


INITIAL FILL OF THE RINSE BOOSTER
On delivery, the switching function S28 (first booster filling) is set to "0". There is no menu "boF" as in
previous control. As the booster is controlled by a pressure transmitter, no initial fill must be carried out.
Therefore the booster heating is not locked.

REQUIREMENT: MACHINE "OFF" AND HOOD OPEN

If the hood will be closed or if no button is pressed within 10 seconds, the display switches off automatically
and the new settings will be saved.

Push Stop and Program button at the same time.

EXAMPLE: DISPLAY
parameter range
Select function with the program button. rinse wash
1 Detergent dosage CH1 XX C16 0-50 s
2 Rinse aid dosage – program P01 to P04 CH2 X.X C18 0-50 s
3 Detergent dosage – not used CH3 -- C20 0-50 s
4 Rinse aid dosage – program basic clean (AUP only) - not active CH4 X.X C19 0-50 s
Set chemicals values with the ON/OFF button (0.5s steps).
5 Water hardness adjustment H01 C60 - C63
Set value with the ON/OFF button (basic setting H02). up to
H01 = up to 7°dh / H02 = 8 to 14°dh / H03 = 15 to 21°dh / H04
H04 = 22 to 30°dh
To initiate a manually regeneration with the next wash cycle press the Hereby the softener function will be set to initial
stop button for 3 seconds (confirmed by the flashing water hardness condition. (With next wash cycle, regeneration
indication). starts automatically.)
6 Wash cycle counter PXX XXX C73 + C74 0-999999
Reset to "0" only via basic data (service menu).
7 Water consumption counter EXX XXX C77 + C78 0-999999
Reset to "0" only via basic data (service menu).
8 Remaining water quantity counter for external water treatment dXX XXX C79 + C80 0-999999
To reset the counter to pre-set value, press ON/OFF button for 3 seconds. S18
CLOSE THE Hood
9 Hose priming detergent (dispenser M4) SF1 --0 0/1
By pushing the ON/OFF button, relay 5 will be activated for 60 seconds. --1
10 Hose priming rinse aid (dispenser M3) SF2 --0 0/1
By pushing the ON/OFF button, relay 6 will be activated for: --1
AMX(X) / AUXX = 360 seconds / AUP = 130 seconds
To interrupt a priming cycle, push the ON/OFF button again.
11 Acoustic signal (AUP models only) - not active S S24 0/1
By pushing the ON/OFF button acoustic signals will be activated ("1") or S --0/--1
deactivated ("0"). There are 3 different signals:
end of program: 1 x 2.0s "ON"
noncritical failure: 2 x 0.5s with 0.5s pause
critical failure: 5s continuous signal
12 Chemicals deficiency sensor CH --0/--1 0/1
By pushing the ON/OFF button sensors will be activated ("1") or
deactivated ("0").
To quit the menu : – point 1 to 8 – close the hood, point 9 to 11 – open the hood
– or do not press any button during next 10 seconds
The indicator switches itself off and the new settings will be saved.

Page 6 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 6 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

5. HYDRAULIC SCHEMATICS

5.1 LEGEND OF COMPONENTS

B1 TEMPERATURE SENSOR BOOSTER


B2 TEMPERATURE SENSOR TANK
B3 PRESSURE TRANSMITTER BOOSTER
B4 PRESSURE TRANSMITTER TANK

E1 BOOSTER HEATING
E2 TANK HEATING

M1 WASH PUMP
M2 RINSE PRESSURE PUMP
M3 RINSE AID DISPENSER
M4 DETERGENT DISPENSER
M5 DRAIN PUMP

S1 REED-SWITCH – HOOD
S2 AIRGAP IMPELLER 1)
S3 SALT DEFICIENCY SWITCH 2)
S4 REED-SWITCH – STRAINER

Y1 SOLENOID VALVE – FILL


Y3.1 VALVE RESIN A 2)
Y3.2 VALVE RESIN B 2)
Y4.1 VALVE RESIN B/A 2)
Y4.2 VALVE DRAIN/BOOSTER 2)

  1 WATER SUPPLY HOSE


  2 WATER INLET AIRGAP 1)
  3 BOOSTER
  4 WASH ARM
  5 RINSE ARM
  6 SALT CHAMBER 2) 
  7 RESIN A / RESIN B 2)

1) AIRGAP ASSY.
2) SOFTENER ASSY.

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 7


Before Maintenance Please Read SAFETY Instructions 7 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

5.2 AMX(S) / AMXX(S) / AUXX(S)

WITHOUT SOFTENER

5.3 AMXT / AUXXT

WITHOUT SOFTENER

Page 8 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 8 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

6. FILLING
6.1 IMPELLER SWITCH

The impeller switch S2 monitors the incoming water flow by counting impulses and then relaying that
information back to the main PCB. The count rate is 200 impulses per litre.
1. Water consumption counter [C77] + [C78] (counted litres are added to basic value "0").
2. Remaining water quantity counter for external water treatment [C79] + [C80] + [S18] (counted litres are
subtracted from preset value). See also chap. 9.3, page 22.

MAINTENANCE – TO BE CHECKED:
Whether leaking water from the airgap overflow enters the wash tank chamber (visual
inspection). If so, the leaking water quantity must not exceed 100 ml per fill step.
Whether the impeller sensor works. This can be carried out in two ways.
1. Service Menu: Select input S2 and activate the fill valve by pushing the ON/OFF button
(--0 / --1 will be displayed alternately). See also chap. 9.1.2, page 18.
2. Visual check: quick flashing LED on main board (see page 20).

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 9


Before Maintenance Please Read SAFETY Instructions 9 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

6.2 PRESSURE TRANSMITTER B3 / B4


Via air traps (booster / wash tank) compressed air will be directed via clear hoses to the pressure
transmitter booster (B3) and wash tank (B4). The transmitter changes the upcoming pressure into
DC voltage which will be processed by the control as water level message.
If there is no fault, the voltage value can be displayed:
– via the service menu F03 fill level booster / F04 fill level wash tank or
– set switching function [S56] to "1" (menu U02).
Possible faults see page 24.

Output voltage * Pressure transmitter B3 (booster)


approx. 0.50 V Booster is empty. Fill valve will be activated.
approx. 0.62 V Booster heating will be switched on (heating up to fill start temperature 85°C).
approx. 0.90 V Booster is filled. Fill valve closes.

Output voltage * Pressure transmitter B4 (tank) – example AMX


approx. 0.50 V Wash tank is empty.
approx. 0.65 V Tank heating will be switched on.
approx. 1.00 V Machine is ready for operation (tank is filled).
approx. 1.15 V With a delay-time of 5 seconds drain pump will be activated until normal water level
is reached. (Error UL)
approx. 0.60 V At the end of the self cleaning cycle water remains in the wash tank.
When the machine will be switched on the next time, "AL" error will be displayed.

Voltage value* additions for pressure transmitter B4 (tank):

Model tank heating tank filled safety level AL negative


ON (UL) pressure
AMX / AMXT 0.65V (ca. 13 l) 1.00V (ca. 21 l) 1.30V (ca. 27 l) 0.60V (ca. 12 l) 0.58V (ca. 11 l)
AMXX 0.65V (ca. 13 l) 1.55V (ca. 33 l) 1.90V (ca. 40 l) 0.60V (ca. 12 l) 0.80V (ca. 15 l)
AUXX(L) / AUXXT 0.65V (ca. 13 l) 1.90V (ca. 40 l) 2.25V (ca. 48 l) 0.60V (ca. 12 l) 0.80V (ca. 15 l)

* Voltage values may not be changed by


the service technician (only on instruction
of HOBART).

B3
MACHINES WITH EXTERNAL FILLING
If external filling is activated (S20 set to "1"),
a voltage regulation of 0.1 V must take place
within 30 seconds, after a holding time of
60 seconds.
Otherwise the error message FIL will be
displayed.

B4

Page 10 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 10 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

6.3 DOSING EQUIPMENT

6.3.1 HOBART DETERGENT / RINSE AID DISPENSER - (OPTIONAL)

DISPENSERS
AMX / AUXX Detergent (00-883860-002): delivery rate 3.0 l/hr hose inside: Kit 00-883860-012
Rinse aid (00-883860-001): delivery rate 1.3 l/hr hose inside: Kit 00-883860-011
PRE-ADJUSTED VALUES
Detergent CH1 All models: "8" = 8.0 s ≈ 2.40 g/l (possible range 0-50 s ≈ 0-15.4 g/l)
Rinse aid CH2 AMX(X)/AUXX: "7.0" = 7.0 s ≈ 0.31 g/l (possible range 0-50 s ≈ 0-2.2 g/l)
AUP: "2.5" = 2.5 s ≈ 0.33 g/l (possible range 0-50 s ≈ 0-6.6 g/l)
DOSAGE
Detergent Pre-dosing is activated simultaneous with rinse pump M2.
Wash dosing is activated simultaneous with the wash pump.
Rinse aid Pre-dosing is activated after the end of the fill cycle.
Wash dosing is activated after the end of wash cycle.
Hose priming and factory settings see page 6 "Customer Menu".

MAINTENANCE
1. Check hoses, dispensers and connections.
2. As a precaution, the dosing hoses have to be replaced every two years (hoses inside dispensers,
suction and pressure hoses).
Dosing hoses (sold by meter) – part no. 01-246301-099

Installation of dosing hoses (e.g. AMXX):

Do not use adhesive clamp!

Dosing PCB

Inspection window
Check if plug is connected correctly.

detergent rinse aid

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 11


Before Maintenance Please Read SAFETY Instructions 11 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

6.3.2 ADJUSTMENT OF CHEMICALS DEFICIENCY SENSORS - (OPTIONAL)

POTENTIOMETER:
Graduations: 1 to 9
Sensitivity: 1 (non-sensitive chemical sensing /
detergent
sensitive failure indication)
LED 9 (sensitive chemical sensing /
non-sensitive failure indication)
Basic setting: 3
rinse aid
LED detergent

rinse aid

Due to the physical properties of rinse aid (e.g. wetting), even smallest rinse aid quantities inside the hose
will be detected by the deficiency sensor. If the sensor is adjusted too sensitively, maybe deficiency will not
be released.

– TEST "DEFICIENCY"
Flush the suction hose thoroughly with fresh water to remove any chemicals.
When the hose is drained, the respective LED should be "OFF".

– TEST "FULL"
Fill the suction hose (see chapter 4, page 6).
The respective LED should light up. If not, adjust potentiometer until the LED lights up.
Now the hose should be completely filled and without air bubbles.

TESTING THE PCB


– Select Service Mode (see chapter 9.1.2, page 18).
– Hoses are empty and deficiency sensor potentiometers turned to left stop:
Switching functions "S07" (detergent) and "S08" (rinse aid) must be "0". No sensor LED lights up.
– Potentiometers turned to right stop:
Switching functions "S07" (detergent) and "S08" (rinse aid) must be "1". The LED of the respective
circuit lights up.


Detergent deficiency indication "- - 0" Rinse aid hose filled "- - 1"

– After testing:
Set potentiometers (detergent and rinse aid) to value "3" (based on tests with the most common
products).

Page 12 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 12 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

6.4 BOOSTER / TANK / TEMPERATURE PROBES

BOOSTER
Total volume: 10.3 liter
Useable volume: 5.2 liter
Water consumption / rinse cycle: 2.5 liter

TANK
AMX AMXX AUXX AMXT AUXXT
Tank volume (liter):
21 33 40 42 80

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 13


Before Maintenance Please Read SAFETY Instructions 13 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

7. WASHING
7.1 WASH PUMP AND STRAINER SYSTEM
The pump unit includes motor with flange, mechanical shaft seal, impeller and capacitor (AMX only).
A non return flap (called Flipper) allows the draining of the circulation system.
The Flipper prevents soil, collected in the pump sump, from reentering the circulating system.

7.1.1 FUNCTION:
During wash cycle, the wash liquid is distributed to the upper and lower wash arm. The back flowing wash
liquid is passing a strainer system, the integrated intake strainer and enters the wash pump from the outer
annular space of the suction unit via the main duct.
Drain system: Used for partial draining of the soiled wash liquid (Genius X2) during wash cycle (approx.
20 seconds after program start) or for the complete draining of the wash tank. Pressure-side the soiled
wash liquid will enter the drain via hose system and ventilation valve.
During draining or self-cleaning cycle the flipper is open.

Sectional drawing Genius X2

"A"

"A" flow direction during wash cycle

Flipper closed (during recirculation)

When the overflow pipe is missing,


flap "A" closes to provide water filtration
during recirculation.
Flipper open (during draining)

MAINTENANCE NOTE:
– Check movability of flipper. Tank strainer and fine strainer have to be
– Clean fine strainer if necessary. cleaned daily.
– Remove drain pump and clean it.
– Subsequently carry out leakage test.
Furthermore the ventilation valve has to be checked
for soiling.

Page 14 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 14 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

7.1.2 TECHNICAL DATA

WASH PUMPS – CONNECTED LOAD

Part no. Voltage / Frequency / Phases Current Capacitor Power Impeller


00-883617-001 220-240V / 50Hz / 1P 3.2A 16μF 0.73kW 105mm
AMX / AMXT
00-883617-002 220-240V / 60Hz / 1P 3.4A 16μF 0.73kW 90mm
00-883526-001 220-240V (380-415V) / 50Hz / 3P 3.5A (2.1A) --- 1.1kW 105mm
AMXX / AUXX / 00-883526-002 220-240V (380-415V) / 60Hz / 3P 3.2A (1.8A) --- 1.1kW 90mm
AUXXT
00-883526-003 254-277V (440-480V) / 60Hz / 3P 2.8A (1.6A) --- 1.1kW 90mm
00-883525-001 220-240V (380-415V) / 50Hz / 3P 3.5A (2.1A) --- 1.1kW 105mm
AUXX / AUXXT 00-883525-002 220-240V (380-415V) / 60Hz / 3P 3.2A (1.8A) --- 1.1kW 90mm
00-883525-003 254-277V (440-480V) / 60Hz / 3P 2.8A (1.6A) --- 1.1kW 90mm

WASH PUMPS – SERVICE KITS


00-883617-010 50Hz
AMX / AMXT The Service Kits include:
00-883617-020 60Hz
00-883526-010 50Hz 1. O-ring
AMXX / AUXX /
2. Impeller
AUXXT 00-883526-020 60Hz 3. Mechanical shaft seal
00-883525-010 50Hz
AUXX / AUXXT
00-883525-020 60Hz

7.1.3 CHECKING THE DIRECTION OF ROTATION

To be done with first run or after pump replacement (only


with filled wash tank).
1. Remove panels.
2. Put a binder approx. 2 cm into the motor ventilation
housing grid and keep it hold.
3. Switch on machine.
Determine, into which direction of rotation the motor
starts. The direction of rotation must always point to
direction of arrow (see picture).
4. If motor turns in the opposite direction, interchange two
of the three phases at the power supply cable.
5. Check direction of rotation again.
Switch off machine and put panels back into place. direction of rotation requirement
NOTE: (example AUXX/AUP)
Check is not necessary with AM/AMX models (alternating
current pumps).

7.2 RINSE PUMP


Part number 00-775854-001 00-775854-002 average average
rinse time rinse time
Voltage 220-240 V = value value
Frequency 50 Hz 60 Hz 7.5 s 2.5 l 9.5 s 3.2 l
Current 0.46 A = 8.0 s 2.8 l 10.0 s 3.4 l
Power 0.14 kW = 8.5 s 2.9 l 10.5 s 3.5 l
Capacitor 5.0 µF / 400V 9.0 s 3.1 l 11.0 s 3.6 l

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 15


Before Maintenance Please Read SAFETY Instructions 15 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

8. HOOD – DETAILS
MAINTENANCE
Check plastic bearings for sufficient lubrication.

Hood lift handle Support

Y
6
3
60
6

There are two different spring bolts:


883683-1 (x = 8 mm / y = 18 mm)
883683-2 (x = 12 mm / y = 22 mm)

See also table below.

Adjustment of tension springs Example: AMX


Distance "A" from lower edge of bent to upper edge
of channel:
approx. 12 cm – insulated hood
approx. 18.5 cm – non-insulated hood

Insufficient spring force:


The hood keeps not safe in "stand-by" position or
A

closes.

Too much spring force:


The hood does not keep tightly closed during wash
cycle.

Make sure, that in "stand-by" position the hood


neither opens nor slowly closes.

Spring bolt Part No. AMX AMXX AUXX AMXT AUXXT AUXXL
insulated 00-883683-001 x x x
hood 00-883683-002 x x x
non-insulated
00-883683-002 x x x x x x
hood

Tension spring
2x1 00-883636-001 x x x
1x2 right hand 00-883957-001 x x x
1x2 left hand 00-883958-001 x x x

Page 16 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 16 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

9. ELECTRONIC CONTROL
9.1 KEY COMBINATIONS

9.1.1 BASIC OPERATION / CUSTOMER SETTINGS

SERVICE ON/OFF
PROGRAM
STOP

X = button to be pushed

BASIC OPERATION STOP PROGR. SERVICE ON/OFF REQUIREMENTS HOOD


Machine ON X Machine "off" Open or Close
Machine OFF X Machine "off" at any time Open or Close
Drain program X>3s Start at any time Close
Program selection X Machine on / Fill program completed Open or Close
Program start X Machine on / Fill program completed Close
Temperature display X>3s Temperature display for 10 seconds Open or Close
Special programs X Machine on / Fill program completed Open or Close

CUSTOMER SETTINGS X X Machine Off OPEN


DISPLAY
UPPER LOWER
Detergent dosage CH1 value C16 Open
Rinse aid dosage CH2 value C18 Open
Select function with the program button.
Detergent dosage Cold 1 CH3 value C19 Open
Detergent dosage Cold 2 CH4 value C20 Set value with the ON/OFF button. Open
Hardness H01 - H04 Open
Wash cycle counter P + C74 value C73 Open
Reset only by Service.
Water counter - Total E + C78 value C77 Open
Water counter - Demi d + C80 value C79 Reset by pushing the ON/OFF button for 3 seconds. Open
CLOSE HOOD
Hose priming detergent SF1 0-1 Select function with the program button. Close
Hose priming rinse aid SF2 0-1 Activate appropriate dosing pump with the ON/OFF button. Close
Acoustic signal S 0-1 Activate / deactivate with the ON/OFF button. Close
Chemicals sensor CH 0-1 Activate / deactivate with the ON/OFF button. Close

See also page 6 "First run / Customer Menu" and page 22 "Counter Functions".

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 17


Before Maintenance Please Read SAFETY Instructions 17 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

9.1.2 SERVICE MENU

Requirements: Machine OFF and Hood open.


Push Stop, Program and Service button to enter the Service Menu.
DISPLAY: UPPER LOWER
S01 - - 0 (ON/OFF button illuminates green)
CLOSE HOOD (door switch test S1) S01 --1
Select appropriate Input or Output by pushing the Program button.
Inputs test:
X13.3 Impeller switch S02 --0 no signal / - - 1 signal from S2
Push ON/OFF to activate additionally fill valve Y1. --0 / - - 1 will be displayed alternately
X13.5 Salt switch status S03 --0 salt container is filled / - - 1 when empty
X13.7 Strainer S04 --0 not in place / - - 1 strainer in place
X13.9 Reserve S05 --0
X13.11 Reserve S06 --0
X12.3 Detergent deficiency1) S07 --0 no deficiency / - - 1 when empty
X12.4 Rinse aid deficiency1) S08 --0 no deficiency / - - 1 when empty
1) Push ON/OFF to activate the respective dispenser (M4/M3). ... moving light point – dispenser activated
Activation will persist until remedy of deficiency.
Temperature probes test: 0-105°C = okay / - - 1 = short circuit (>99°C) / - - 2 = open circuit (< 0°C)
X14.1/2 Temperature sensor booster B1 F01 actual Temperature
X14.3/4 Temperature sensor tank B2 F02 actual Temperature
Pressure transmitter test: 0.3 - 4.0V = okay / - - 1 = > 4.0V / - - 2 = open circuit < 0.3V
X14.7 Pressure transmitter booster B3 F03 voltage display (booster level)
X14.10 Pressure transmitter tank B4 F04 voltage display (tank level)
Outputs test: - - 0 = not active / - - 1 = active
Hood must be closed. Selected output can be activated with the ON/OFF button. Starting from A01: push Stop button to scroll back.
Voltage supply Triac RL1.1 A00 --0
X1.1/3 Bypass Triac RL1 A01 --0
X2.1/2 Tank heating E2 (K2) RL2 A02 --0
X3.1/3 Wash pump High Pressure RL3 A03 --0 AUXX
Wash pump (Low Pressure) – left AMXT / (AUXXT)
X4.1/3 External fill Y2 RL4 A04 --0 (option)
X5.1/3 Detergent dosage M4 RL5 A05 --0
X6.1/3 Rinse aid dosage M3 RL6 A06 --0
X7.1/3 Fill valve Y1 RL7+RL14 A07 --0
X8.1/3 Drain pump M5 RL8 A08 --0
X9.1/3 Rinse pump M2 RL9 A09 --0
X10.1/3 Booster heating E1 RL10 A10 --0
X21.6 Softener - salting A Y3.1 RL11 A11 --0 only with built-in extension board
X21.7 Softener - salting B Y3.2 RL12 A12 --0 only with built-in extension board
X21.8 Fill B-A Y4.1 RL13 A13 --0 only with built-in extension board
X21.9 Drain / booster Y4.2 RL14 A14 --0 only with built-in extension board
X22.1/3 Reserve RL15 A15 --0 only with built-in extension board
X23.1/3 Reserve RL16 A16 --0 only with built-in extension board
X24.1/2 PFK1 RL17 A17 --0 only with built-in extension board
X25.1/2 PFK2 RL18 A18 --0 only with built-in extension board
X26.1/2 PFK3 / RL19 A19 --0 only with built-in extension board
Wash pump High Pressure – left + right AUXXT
X1.1/3 Wash pump (Low Pressure) RL1+RL1.1 A20 AMX / AMXX / (AUXX)
Wash pump (Low Pressure) – right AMXT / (AUXXT)
Handle lightning Grl - FF
Operation unit test BAE --0
Counter reset (C72-C80 + C84-C85) r ES --0 / - -1 when ON/OFF button is pushed (3s)

EXIT THE TEST PROGRAM BY OPENING THE HOOD (only possible with menu item "outputs test").

Page 18 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 18 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

9.1.3 PROGRAMMING / MODIFICATION OF BASIC DATA / SOFTENER TEST

SERVICE ON/OFF
PROGRAM
STOP

REQUIREMENT: MACHINE "OFF" AND HOOD OPEN.

– Push Program and Service button together.


Software release will be displayed short-time.

– Push Stop button to select the menu item.


U01 = Machine type selection
U02 = Basic data sheet
U03 = Softener test program

– The selected function will be confirmed with the ON/OFF button and
indicated by the illuminated ON/OFF button.
Red = Machine type selection
Blue = Basic data sheet
Green = Softener test program

MACHINE TYPE SETTING: U01


– Set machine type with the Stop button (01 – 26, sequential scan only).
Program Number see page 3.

– Push ON/OFF button for 2 seconds.

The selected program with the basic data’s will be saved and the "Red" illuminated
ON/OFF button switches off.

MODIFICATION OF BASIC DATA: U02


– Set function with the Stop button (forwards) or first Program button and then Stop button (backwards).
(Sequential scan or quick scan by holding the button.)

– Change value upwards (+) with the Program button and downwards (–) with the Service button.
(Sequential scan or quick scan by holding the button.)

– Decimal points will appear.

– Push and hold the ON/OFF button.

New value is saved when the points disappear.

SOFTENER TEST PROGRAM: U03

– Push ON/OFF button.

Test program starts according to diagram.

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 19


Before Maintenance Please Read SAFETY Instructions 19 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

9.2 PRINTED CIRCUIT BOARDS

[B10]
9.2.1 MAIN BOARD

DETERGENT DEFICIENCY
RINSE AID DEFICIENCY
DEFICIENCY OF SALT

E3
IMPELLER SWITCH

R13

R12
DOOR SWITCH

E2
STRAINER

RESERVE

RESERVE

E3
E2

5V
S1

S2

S3

S4

S5

S6

S7
S8
3
4
2
1
1
2
3
4
Jumpers are open

PE
1
2
3
4
5
6
7
8
9
10
11
12

1
2
3
4
X13

S7
S8
9 10
O

0
U
T

J2

5
PRES. TRANSMITTER B4 X12
P

A1
LED 1

LED 2

TANK
T N

8
U I

J1

1
O

321
PRES. TRANSMITTER B3
P

BOOSTER SLOT: E-EPROM (897547-4) N / L2


N

1
I

X14

5 3 1
4

TEMP. PROBE B2
LED 3 L1
3

3
TANK
X0
2

TEMP. PROBE B1 PE
1

5
BOOSTER

L1
X15

1
OPERATION PANEL 1 3
1

NOTE: X11A
N / L2

3
X20A Only the fully equipped
X16

RL1.1
PCB 00-897545-001
1

is available as replacement.
X17

INTERFACE RL1
1

RL2
X18

RL9 RL8 RL7 RL6 RL5 RL4 RL3


1

RL10
L
1

L
1

L
1

L
1

L
1

L
1

L
1

L
1
1

1 2 3
3 2

3 2

3 2

3 2

3 2

3 2

3 2

3 2
2
N

X10 X9 X8 X7 X6 X5 X4 X3 X2 X1

LED 1 hood switch: ON = hood closed


LED 2 impeller switch: unsteady = water flow (pulses)
LED 3 processor function: flashing = voltage on, processor running
permanent = voltage on, processor not running

Note: The control works with or without plugged E-EPROM 00-897547-004.


TO INSTALL A NEW SOFTWARE RELEASE:
1. Disconnect control fuse F1.
2. Plug in the new E-EPROM and reconnect F1.
A check is carried out and the stored software will be updated automatically
(the progress is indicated at the display by L9, L8, ...).
3. Set machine type – see page 19, menu U01 (also to be done after replacing the PCB).
4. Disconnect control fuse F1, remove E-EPROM and reconnect F1.

Page 20 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 20 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

9.2.2 EXTENSION BOARD A3

POT. FREE CONTACT S63 (AUXXT = HIGH PRESSURE)

MAIN BOARD
A1 X11A.1
A1 X11A.3
1
X26

POWER SUPPLY
RL19

L1
RL17

RL16

RL15

RL14

RL13

RL12

RL11

1
X11B
X20B
N/L2
RL18

X25 X24 X23 X22 X21


N N N N
1 1 N 1 N 1 L 1
POT. FREE CONTACT S62

POT. FREE CONTACT S61

RESERVE

RESERVE

Y4.2
Y4.1
Y3.2
Y3.1
DRAIN / BOOSTER
FILL B-A
SALTING B
SALTING A

NOTE:
The additional board (00-897546-001) is only built in at machines with softener.

This PCB has three potential-free contacts. Each one can be assigned to different switching functions
via one parameter (only on extension board):

Parameter [S61] = RL17 (X24) switches: PFK1


0 = machine "On"
1 = program "On"
2 = temperature F02 / F05 below pre-set value
3 = fill or wash progam active

Parameter [S62] = RL18 (X25) switches: PFK2


0 = program "On"
1 = machine "On"
2 = rinse pump "On" (switch-off delay [C86])
3 = fill progam active

Parameter [S63] = RL19 (X26) switches PFK31)


0 = fill progam active
1 = rinse pump "On" (switch-off delay [C86])
2 = temperature F02 / F05 below pre-set value
3 = fill or wash progam active
1) With AUXXT models: high pressure switching.

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 21


Before Maintenance Please Read SAFETY Instructions 21 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

9.3 COUNTER FUNCTIONS

Request for hygiene program [C71] – down-counter


The number of wash cycles will be subtracted from the preset value ([S19] "on").
When "0" is reached, start of hygiene program is requested.
After hygiene cleaning is completed, this counter will be reset to basic value.

Number of hygiene cycles [C72] – up-counter / basic value "0"


The number of completed hygiene cycles is counted.
Reset only possible via basic data.
Note: Control, how often the program has been started.

Number of wash cycles [C73] + [C74] – up-counter / basic value "0"


The number of wash cycles will be counted.
Example 1420 cycles: [C73] = 420 / [C74] = 1
Note: Readout and note down in the report.

Service interval [C75] + [C76] – down-counter


The number of wash cycles will be subtracted from the preset value ([S17] "on").
When [C75] + [C76] is "0", the service indicator illuminates.
Reset only possible via basic data.
Note: Of interest in case of service contract.

Water consumption [C77] + [C78] – up-counter / basic value "0"


After 200 input pulses of S2 (= 1 litre water flow), the counter value will be increased by 1.
Input pulses below 200 are buffered and counting will continue with the next input pulses.
Reset only possible via basic data.
Note: The customer can readout the actual water consumption (see page 8 "customer menu").

Remaining water quantity (external water treatment) [C79] + [C80] + [S18] – down-counter
This function will be programmed via service mode U02 (see page 17).
[S18] = activation
[C79]+[C80] = water treatment capacity (liter). Possible settings are [C79] 0-999, [C80] 0-999 x 1000.
Example 5500 litres: [C79] = 500 / [C80] = 5
After 200 input pulses of S2 (= 1 litre water flow), the counter value will be decreased by 1.
Input pulses below 200 are buffered and counting will continue with the next input pulses.
When "0" is reached, "d 0" will be displayed.
Reset to pre-set value via customer menu by pushing the ON/OFF button (see page 6).
Note: The actual value can be checked via customer menu (indication for next replacement of external
demineralisation cartridge for example).

Number of salt fillings – deficiency of salt [C84] – up-counter


The number of "salt indicator switch-on" will be counted.
Note: With this parameter you can check how often the softener has been refilled.

Wash cycles with deficiency of salt [C85] – up-counter


The number of started wash cycles in spite of salt deficiency (illuminated salt indicator) will be counted.
Note: Maybe an evidence in the case of calcified machine or heating elements for example.

NOTE:
Starting from E-EPROM rev. 3.0, the actual counter readings keep unchanged after software update
as well as settings of detergent and rinse aid dispensers (rev. 3.9).
Reset of all counters can be carried out via menue option rES in Service Menu (see also page 18).

Page 22 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 22 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

10. FAULTS
10.1 UNCRITICAL FAULTS
Fill, wash and drain program can be started.
During the fill program, uncritical faults are only indicated by the indicator lights and error codes (none
green/red flashing ON/OFF button).

INDICATOR THE ON/OFF BUTTON IS FLASHING GREEN/RED ALTERNATELY.


Rinse Wash Lamp FAULT PARAM.
AL Drain fault Level switch value [F11] still exceeded at the end of the drain cycle. F11
To reset, repeat drain program until value is below [F11].
Possible cause Remedy
1. Kinked drain hose. 1. Place drain hose correctly.
2. Drain pump does not run (jammed or 2. Check drain pump, dismantle if necessary.
defective).
3. Pressure transmitter B4 defective 3. Check voltage level (service menu).
(wiring, PCB).
4. Trap possibly clogged. 4. Check trap.

HEI Thermostop The thermostop time [C25] is exceeded (max. heating period for C25
wash and fill cycle). S02
Reset via machine "OFF-ON". S58
Possible cause Remedy
1. Booster heating defective. 1. Replace booster heating.
2. Missing phases. 2. Check phases (also at site).
3. Machine single-phase connected (230 V). 3. Connect to three-phase current if possible.
4. Tank heating defective (with termostop 4. Replace tank heating.
tank) parameter S58.

CH1 Chemical Detergent deficiency X12.3 "on" / rinse aid deficiency X12.4 "on".
deficiency If both containers are empty, CH1/CH2 is displayed alternately.
CH2
Possible cause Remedy
1. Chemical container empty / suction 1. Refill container / carry out hose priming.
hoses not filled.
2. Adjustment of chemical deficiency 2. Check settings (see chap. 7.3.2, page 17).
sensors not correct.
3. Missing electrical supply (X12.1/2). 3. Check voltage (X12.1 +5V, X12.2 0V) /
check crimp connection.

SAL Salt deficiency Softener salt deficiency indication – X13.5 "on" S05
(only if softener [S05] = "1").
Possible cause Remedy
1. Salt container empty. 1. Refill container with regeneration salt.
2. Float switch inside salt container 2. Loose the container a little and shake
jammed [S3]. slightly.
3. Loose contact on PCB (X13.5/6). 3. Check crimp connection and contacts.

d0 External water Only if activated in service mode [S18]. C79


treatment (option) The preset water quantity [C79] + [C80] is reached (down-counter). C80
For reset see customer menu. S18
Possible cause Remedy
1. Counter reading of preset water quantity 1. Reset counter (see customer menu).
(liter) is "0".
2. Switching function [S18] is set to "1" 2. Enter the desired water quantity (liter).
without specified water quantity.

CLOSE Hood Cause Remedy


Fill cycle interrupted as hood is open. Close hood, filling will continue.
(running indication)

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 23


Before Maintenance Please Read SAFETY Instructions 23 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

10.2 CRITICAL FAULTS


Only the drain program can be started. Fill program and all wash programs are locked.

INDICATOR THE ON/OFF BUTTON ILLUMINATES RED.


Rinse Wash Lamp FAULT PARAM.
F01 --1 Temperature probe Booster heating RL10 will be switched off immediately.
BOOSTER B1 Fill and wash programs are locked, drain program can be started.
--2
Possible cause Remedy
1. - - 1 = short circuit (temperature probe 1. Check wires, replace temperature
or wires to probe). probe.
2. - - 2 = open circuit. 2. Replace wiring, replace temperature
probe if necessary.
3. Inlet temperature to low. 3. Check inlet temperature.

F02 --1 Temperature probe Tank heating RL2 will be switched off immediately.
TANK B2 Fill and wash programs are locked, drain program can be started.
--2
Possible cause Remedy
1. - - 1 = short circuit (temperature probe 1. Check wires, replace temperature
or wires to probe). probe.
2. - - 2 = open circuit 2. Replace wiring, replace temperature
probe if necessary.

F03 --1 Pressure trans­mitter Control of input voltage X14.7 – min. 0.3V up to max. 4.0V.
BOOSTER B3 If the input voltage is out of range, the running program will be
--2 stopped.
Fill and wash programs are locked, drain program can be started.
Possible cause Remedy
1. - - 1 = short circuit (transmitter or wires 1. Check wires, replace transmitter B3.
to transmitter) / > 4.0V.
2. - - 2 = open circuit / < 0.3V. 2. Replace wiring, replace B3 if necessary.

F04 --1 Pressure trans­mitter Control of input voltage X14.10 – min. 0.3V up to max. 4.0V.
TANK B4 If the input voltage is out of range, the running program will be
--2 stopped.
Fill and wash programs are locked, drain program can be started.
Possible cause Remedy
1. - - 1 = short circuit (transmitter or wires 1. Check wires, replace transmitter B4.
to transmitter) / > 4.0V.
2. - - 2 = open circuit / < 0.3V. 2. Replace wiring, replace B4 if necessary.

--3 Pressure trans­mitter The max. water quantity [C82] is exceeded and value [F16] is not C82
TANK B4 / reached. Only "draining" possible. F16
SOFTENER
Possible cause Remedy
1. Air trap blocked or leaky. 1. Check air trap, clean or replace if
necessary.
2. Hose to pressure transmitter leaky. 2. Replace hose.
3. Valve Y4.2 locked (drain direction) or coil 3. Run Softener Test. Replace switching
defective. valve if necessary.
4. Extension board not correctly plugged to 4. Plug in correctly.
Main PCB.
To quit the fault: start drain program or reload machine program no. (U01 see page 23).

SIE STRAINER Reed-switch [S4] (X13.7) more than 5 seconds "off". S38
CONTROL Start of fill and wash programs is locked automatically.
Possible cause Remedy
1. Tank strainer is missing or not correctly 1. Put strainer correctly in place.
positioned.
2. Magnet at the strainer is missing. 2. Fit magnet.
3. Reed switch in wrong position. 3. Put reed switch in correct position.
4. Cable break. 4. Replace reed switch and cable.

Page 24 / AMX(X)/AUXX Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 24 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

INDICATOR THE ON/OFF BUTTON ILLUMINATES RED.


Rinse Wash Lamp FAULT PARAM.
FIL FILL 1 The fill valve Y1 (RL7) is triggered and the impeller switch S2 does
not count (no impulses on X14.3).
Reset via input pulses on X14.3 or machine "OFF".
Possible cause with incoming water Remedy
1. Bad contact at impeller switch plug 1. Check contacts, solder plug (airgap) if
(airgap) or PCB. necessary.
2. Impeller switch PCB not correctly locked. 2. Check PCB and lock in place.
3. Reed switch in wrong position. 3. Put reed switch in correct position.

Possible cause without incoming water Remedy


1. Shut-off valve is closed. 1. Open shut-off valve at site.
2. Fill valve Y1 defective (wiring and pin). 2. Check fill valve via service mode and
replace if necessary.
3. No output signal from PCB A1 (X7.1/3). 3. Replace PCB.
FIL FILL 2 Exceeded fill time [C43]. C43
The fill valve Y1 (RL7) and all other outputs will be switched off
immediately. Reset via machine "OFF".
Possible cause Remedy
1. See above. 1. See above.
2. Line flow pressure very low. 2. Check line flow pressure.
3. Line strainer clogged. 3. Clean line strainer.
FIL FILL 3 External fill valve is triggered, tank level does not rise. C34
F27
Possible cause Remedy S37
1. Shut-off valve is closed. 1. Open shut-off valve at site.
2. Fill valve Y1 defective (wiring and pin). 2. Check fill valve via service mode and
replace if necessary.
3. Line strainer clogged. 3. Clean line strainer.
UL OVERFLOW When [F18] is exceeded, a running program will be stopped: F17
PROTECTION - after 5 seconds [S37] = "1" F18
- immediately [S37] = "0". S37
The drain pump RL8 will be switched on until [F17] is below preset
value.
Possible cause Remedy
1. Fill valve is jammed and water is running 1. Replace fill valve Y1
permanently.
2. Hose from air trap to pressure transmitter 2. Drain tank manually and replace hose.
tank (B4) is leaky.
3. Not enough water is pumped out. 3. Drain tank manually.
- Drain pump clogged. - Dismantle and clean drain pump or
replace if necessary.
- Kinked drain hose. - Place drain hose correctly.
ERR INTERFACE Communication problem.
Possible cause Remedy
1. Broken connection: Display / Main PCB 1. Check plugs/cable and connect correctly.
2. Defective Circuit Board. 2. Replace PCB.

10.3 OTHER INDICATIONS


INDICATOR THE ON/OFF BUTTON IS FLASHING BLUE/RED ALTERNATELY.
Rinse Wash Lamp FAULT PARAM.
Negative Pressure
Possible cause Remedy
1. Wash tank filters blocked. 1. Remove and flush strainers.

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 25


Before Maintenance Please Read SAFETY Instructions 25 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

NOTES

Page 26 / AMX(X)/AUXX/Series - Marine Version CV 21769-A-03-10


Before Maintenance Please Read SAFETY Instructions 26 sur 28
www.dl-services.com [email protected]
SERVICE TRAINING CENTER

NOTES

21769-A-03-10 AMX(X)/AUXX Series - Marine Version CV / Page 27


Before Maintenance Please Read SAFETY Instructions 27 sur 28
www.dl-services.com [email protected]

SERVICE TRAINING CENTER

An ITW-Company

Before Maintenance Please Read SAFETY Instructions 28 sur 28