AMX(X) / AUXX
SERIES - MARINE VERSION CV
STARTING FROM SERIAL NO 8658 0001
CONTENTS
1. MACHINE DIMENSIONS .................................................................................................................................. 3
2. INSTALLATION . ............................................................................................................................................... 4
2.1 ELECTRICAL CONNECTION ................................................................................................................ 4
2.2 WATER CONNECTION ......................................................................................................................... 4
2.3 DRAIN CONNECTION ........................................................................................................................... 4
3. SMARTTRONIC CONTROLS ........................................................................................................................... 5
3.1 AMX / AUX SERIES – PROFI ............................................................................................................... 5
4. FIRST RUN / CUSTOMER MENU .................................................................................................................... 6
5. HYDRAULIC SCHEMATICS ............................................................................................................................. 7
5.1 LEGEND OF COMPONENTS . .............................................................................................................. 7
5.2 AMX(S) / AMXX(S) / AUXX(S) .............................................................................................................. 8
5.3 AMXT / AUXXT . ..................................................................................................................................... 8
6. FILLING . ........................................................................................................................................................... 9
6.1 IMPELLER SWITCH .............................................................................................................................. 9
6.2 PRESSURE TRANSMITTER B3 / B4 .................................................................................................. 10
6.3 DOSING EQUIPMENT . ...................................................................................................................... 11
6.3.1 HOBART DETERGENT / RINSE AID DISPENSER - (OPTIONAL) ..................................................... 11
6.3.2 ADJUSTMENT OF CHEMICALS DEFICIENCY SENSORS - (OPTIONAL) ........................................ 12
6.4 BOOSTER / TANK / TEMPERATURE PROBES . ................................................................................ 13
7. WASHING ....................................................................................................................................................... 14
7.1 WASH PUMP AND STRAINER SYSTEM ............................................................................................ 14
7.1.1 FUNCTION: . ........................................................................................................................................ 14
7.1.2 TECHNICAL DATA ............................................................................................................................... 15
7.1.3 CHECKING THE DIRECTION OF ROTATION .................................................................................... 15
7.2 RINSE PUMP ....................................................................................................................................... 15
8. HOOD – DETAILS . ......................................................................................................................................... 16
9. ELECTRONIC CONTROL .............................................................................................................................. 17
9.1 KEY COMBINATIONS . ........................................................................................................................ 17
9.1.1 BASIC OPERATION / CUSTOMER SETTINGS .................................................................................. 17
9.1.2 SERVICE MENU .................................................................................................................................. 18
9.1.3 PROGRAMMING / MODIFICATION OF BASIC DATA / SOFTENER TEST ........................................ 19
9.2 PRINTED CIRCUIT BOARDS . ............................................................................................................ 20
9.2.1 MAIN BOARD ...................................................................................................................................... 20
9.2.2 EXTENSION BOARD A3 ..................................................................................................................... 21
9.3 COUNTER FUNCTIONS ..................................................................................................................... 22
10. FAULTS ........................................................................................................................................................... 23
10.1 UNCRITICAL FAULTS ......................................................................................................................... 23
10.2 CRITICAL FAULTS . ............................................................................................................................. 24
10.3 OTHER INDICATIONS . ....................................................................................................................... 25
1. MACHINE DIMENSIONS
758
440
1995*
1995*
1510*
1510*
860*
860*
200*
200*
107
107
635
815
635
815
1268
1390
107
635
870
758
2195*
440
1995*
1610*
1510*
40
860*
860*
200*
110*
107
107
635
815
635
882
107 107
635 635
2. INSTALLATION
2.1 ELECTRICAL CONNECTION
The machines will be supplied as standard with cable H07RN-F 4G 2.5 mm2 (cable length approx. 2.5 m
from cable gland).
According to EN 60 335 the appliance must be connected to an equipotential conductor.
The connecting screw ( ) is located beside the cable inlet.
The machine should be connected to soft and if possible warm water (up to 3 °dh = 0.5 mmol/l, max. 60°C).
Connect the union nut "A" (3/4") of the water supply hose to the site shut off valve.
Do not kink or cut the supply hose. Eventually needed extension has to be provided with a suitable
pressure hose (e.g. 00-324088-001).
3. SMARTTRONIC CONTROLS
3.1 AMX / AUX SERIES – PROFI
8 6
4 2 3 1 9 7 5
If the hood will be closed or if no button is pressed within 10 seconds, the display switches off automatically
and the new settings will be saved.
EXAMPLE: DISPLAY
parameter range
Select function with the program button. rinse wash
1 Detergent dosage CH1 XX C16 0-50 s
2 Rinse aid dosage – program P01 to P04 CH2 X.X C18 0-50 s
3 Detergent dosage – not used CH3 -- C20 0-50 s
4 Rinse aid dosage – program basic clean (AUP only) - not active CH4 X.X C19 0-50 s
Set chemicals values with the ON/OFF button (0.5s steps).
5 Water hardness adjustment H01 C60 - C63
Set value with the ON/OFF button (basic setting H02). up to
H01 = up to 7°dh / H02 = 8 to 14°dh / H03 = 15 to 21°dh / H04
H04 = 22 to 30°dh
To initiate a manually regeneration with the next wash cycle press the Hereby the softener function will be set to initial
stop button for 3 seconds (confirmed by the flashing water hardness condition. (With next wash cycle, regeneration
indication). starts automatically.)
6 Wash cycle counter PXX XXX C73 + C74 0-999999
Reset to "0" only via basic data (service menu).
7 Water consumption counter EXX XXX C77 + C78 0-999999
Reset to "0" only via basic data (service menu).
8 Remaining water quantity counter for external water treatment dXX XXX C79 + C80 0-999999
To reset the counter to pre-set value, press ON/OFF button for 3 seconds. S18
CLOSE THE Hood
9 Hose priming detergent (dispenser M4) SF1 --0 0/1
By pushing the ON/OFF button, relay 5 will be activated for 60 seconds. --1
10 Hose priming rinse aid (dispenser M3) SF2 --0 0/1
By pushing the ON/OFF button, relay 6 will be activated for: --1
AMX(X) / AUXX = 360 seconds / AUP = 130 seconds
To interrupt a priming cycle, push the ON/OFF button again.
11 Acoustic signal (AUP models only) - not active S S24 0/1
By pushing the ON/OFF button acoustic signals will be activated ("1") or S --0/--1
deactivated ("0"). There are 3 different signals:
end of program: 1 x 2.0s "ON"
noncritical failure: 2 x 0.5s with 0.5s pause
critical failure: 5s continuous signal
12 Chemicals deficiency sensor CH --0/--1 0/1
By pushing the ON/OFF button sensors will be activated ("1") or
deactivated ("0").
To quit the menu : – point 1 to 8 – close the hood, point 9 to 11 – open the hood
– or do not press any button during next 10 seconds
The indicator switches itself off and the new settings will be saved.
5. HYDRAULIC SCHEMATICS
E1 BOOSTER HEATING
E2 TANK HEATING
M1 WASH PUMP
M2 RINSE PRESSURE PUMP
M3 RINSE AID DISPENSER
M4 DETERGENT DISPENSER
M5 DRAIN PUMP
S1 REED-SWITCH – HOOD
S2 AIRGAP IMPELLER 1)
S3 SALT DEFICIENCY SWITCH 2)
S4 REED-SWITCH – STRAINER
1) AIRGAP ASSY.
2) SOFTENER ASSY.
WITHOUT SOFTENER
WITHOUT SOFTENER
6. FILLING
6.1 IMPELLER SWITCH
The impeller switch S2 monitors the incoming water flow by counting impulses and then relaying that
information back to the main PCB. The count rate is 200 impulses per litre.
1. Water consumption counter [C77] + [C78] (counted litres are added to basic value "0").
2. Remaining water quantity counter for external water treatment [C79] + [C80] + [S18] (counted litres are
subtracted from preset value). See also chap. 9.3, page 22.
MAINTENANCE – TO BE CHECKED:
Whether leaking water from the airgap overflow enters the wash tank chamber (visual
inspection). If so, the leaking water quantity must not exceed 100 ml per fill step.
Whether the impeller sensor works. This can be carried out in two ways.
1. Service Menu: Select input S2 and activate the fill valve by pushing the ON/OFF button
(--0 / --1 will be displayed alternately). See also chap. 9.1.2, page 18.
2. Visual check: quick flashing LED on main board (see page 20).
B3
MACHINES WITH EXTERNAL FILLING
If external filling is activated (S20 set to "1"),
a voltage regulation of 0.1 V must take place
within 30 seconds, after a holding time of
60 seconds.
Otherwise the error message FIL will be
displayed.
B4
DISPENSERS
AMX / AUXX Detergent (00-883860-002): delivery rate 3.0 l/hr hose inside: Kit 00-883860-012
Rinse aid (00-883860-001): delivery rate 1.3 l/hr hose inside: Kit 00-883860-011
PRE-ADJUSTED VALUES
Detergent CH1 All models: "8" = 8.0 s ≈ 2.40 g/l (possible range 0-50 s ≈ 0-15.4 g/l)
Rinse aid CH2 AMX(X)/AUXX: "7.0" = 7.0 s ≈ 0.31 g/l (possible range 0-50 s ≈ 0-2.2 g/l)
AUP: "2.5" = 2.5 s ≈ 0.33 g/l (possible range 0-50 s ≈ 0-6.6 g/l)
DOSAGE
Detergent Pre-dosing is activated simultaneous with rinse pump M2.
Wash dosing is activated simultaneous with the wash pump.
Rinse aid Pre-dosing is activated after the end of the fill cycle.
Wash dosing is activated after the end of wash cycle.
Hose priming and factory settings see page 6 "Customer Menu".
MAINTENANCE
1. Check hoses, dispensers and connections.
2. As a precaution, the dosing hoses have to be replaced every two years (hoses inside dispensers,
suction and pressure hoses).
Dosing hoses (sold by meter) – part no. 01-246301-099
Dosing PCB
Inspection window
Check if plug is connected correctly.
POTENTIOMETER:
Graduations: 1 to 9
Sensitivity: 1 (non-sensitive chemical sensing /
detergent
sensitive failure indication)
LED 9 (sensitive chemical sensing /
non-sensitive failure indication)
Basic setting: 3
rinse aid
LED detergent
rinse aid
Due to the physical properties of rinse aid (e.g. wetting), even smallest rinse aid quantities inside the hose
will be detected by the deficiency sensor. If the sensor is adjusted too sensitively, maybe deficiency will not
be released.
– TEST "DEFICIENCY"
Flush the suction hose thoroughly with fresh water to remove any chemicals.
When the hose is drained, the respective LED should be "OFF".
– TEST "FULL"
Fill the suction hose (see chapter 4, page 6).
The respective LED should light up. If not, adjust potentiometer until the LED lights up.
Now the hose should be completely filled and without air bubbles.
Detergent deficiency indication "- - 0" Rinse aid hose filled "- - 1"
– After testing:
Set potentiometers (detergent and rinse aid) to value "3" (based on tests with the most common
products).
BOOSTER
Total volume: 10.3 liter
Useable volume: 5.2 liter
Water consumption / rinse cycle: 2.5 liter
TANK
AMX AMXX AUXX AMXT AUXXT
Tank volume (liter):
21 33 40 42 80
7. WASHING
7.1 WASH PUMP AND STRAINER SYSTEM
The pump unit includes motor with flange, mechanical shaft seal, impeller and capacitor (AMX only).
A non return flap (called Flipper) allows the draining of the circulation system.
The Flipper prevents soil, collected in the pump sump, from reentering the circulating system.
7.1.1 FUNCTION:
During wash cycle, the wash liquid is distributed to the upper and lower wash arm. The back flowing wash
liquid is passing a strainer system, the integrated intake strainer and enters the wash pump from the outer
annular space of the suction unit via the main duct.
Drain system: Used for partial draining of the soiled wash liquid (Genius X2) during wash cycle (approx.
20 seconds after program start) or for the complete draining of the wash tank. Pressure-side the soiled
wash liquid will enter the drain via hose system and ventilation valve.
During draining or self-cleaning cycle the flipper is open.
"A"
MAINTENANCE NOTE:
– Check movability of flipper. Tank strainer and fine strainer have to be
– Clean fine strainer if necessary. cleaned daily.
– Remove drain pump and clean it.
– Subsequently carry out leakage test.
Furthermore the ventilation valve has to be checked
for soiling.
8. HOOD – DETAILS
MAINTENANCE
Check plastic bearings for sufficient lubrication.
Y
6
3
60
6
closes.
Spring bolt Part No. AMX AMXX AUXX AMXT AUXXT AUXXL
insulated 00-883683-001 x x x
hood 00-883683-002 x x x
non-insulated
00-883683-002 x x x x x x
hood
Tension spring
2x1 00-883636-001 x x x
1x2 right hand 00-883957-001 x x x
1x2 left hand 00-883958-001 x x x
9. ELECTRONIC CONTROL
9.1 KEY COMBINATIONS
SERVICE ON/OFF
PROGRAM
STOP
X = button to be pushed
See also page 6 "First run / Customer Menu" and page 22 "Counter Functions".
EXIT THE TEST PROGRAM BY OPENING THE HOOD (only possible with menu item "outputs test").
SERVICE ON/OFF
PROGRAM
STOP
– The selected function will be confirmed with the ON/OFF button and
indicated by the illuminated ON/OFF button.
Red = Machine type selection
Blue = Basic data sheet
Green = Softener test program
The selected program with the basic data’s will be saved and the "Red" illuminated
ON/OFF button switches off.
– Change value upwards (+) with the Program button and downwards (–) with the Service button.
(Sequential scan or quick scan by holding the button.)
[B10]
9.2.1 MAIN BOARD
DETERGENT DEFICIENCY
RINSE AID DEFICIENCY
DEFICIENCY OF SALT
E3
IMPELLER SWITCH
R13
R12
DOOR SWITCH
E2
STRAINER
RESERVE
RESERVE
E3
E2
5V
S1
S2
S3
S4
S5
S6
S7
S8
3
4
2
1
1
2
3
4
Jumpers are open
PE
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
X13
S7
S8
9 10
O
0
U
T
J2
5
PRES. TRANSMITTER B4 X12
P
A1
LED 1
LED 2
TANK
T N
8
U I
J1
1
O
321
PRES. TRANSMITTER B3
P
1
I
X14
5 3 1
4
TEMP. PROBE B2
LED 3 L1
3
3
TANK
X0
2
TEMP. PROBE B1 PE
1
5
BOOSTER
L1
X15
1
OPERATION PANEL 1 3
1
NOTE: X11A
N / L2
3
X20A Only the fully equipped
X16
RL1.1
PCB 00-897545-001
1
is available as replacement.
X17
INTERFACE RL1
1
RL2
X18
RL10
L
1
L
1
L
1
L
1
L
1
L
1
L
1
L
1
1
1 2 3
3 2
3 2
3 2
3 2
3 2
3 2
3 2
3 2
2
N
X10 X9 X8 X7 X6 X5 X4 X3 X2 X1
MAIN BOARD
A1 X11A.1
A1 X11A.3
1
X26
POWER SUPPLY
RL19
L1
RL17
RL16
RL15
RL14
RL13
RL12
RL11
1
X11B
X20B
N/L2
RL18
RESERVE
RESERVE
Y4.2
Y4.1
Y3.2
Y3.1
DRAIN / BOOSTER
FILL B-A
SALTING B
SALTING A
NOTE:
The additional board (00-897546-001) is only built in at machines with softener.
This PCB has three potential-free contacts. Each one can be assigned to different switching functions
via one parameter (only on extension board):
Remaining water quantity (external water treatment) [C79] + [C80] + [S18] – down-counter
This function will be programmed via service mode U02 (see page 17).
[S18] = activation
[C79]+[C80] = water treatment capacity (liter). Possible settings are [C79] 0-999, [C80] 0-999 x 1000.
Example 5500 litres: [C79] = 500 / [C80] = 5
After 200 input pulses of S2 (= 1 litre water flow), the counter value will be decreased by 1.
Input pulses below 200 are buffered and counting will continue with the next input pulses.
When "0" is reached, "d 0" will be displayed.
Reset to pre-set value via customer menu by pushing the ON/OFF button (see page 6).
Note: The actual value can be checked via customer menu (indication for next replacement of external
demineralisation cartridge for example).
NOTE:
Starting from E-EPROM rev. 3.0, the actual counter readings keep unchanged after software update
as well as settings of detergent and rinse aid dispensers (rev. 3.9).
Reset of all counters can be carried out via menue option rES in Service Menu (see also page 18).
10. FAULTS
10.1 UNCRITICAL FAULTS
Fill, wash and drain program can be started.
During the fill program, uncritical faults are only indicated by the indicator lights and error codes (none
green/red flashing ON/OFF button).
HEI Thermostop The thermostop time [C25] is exceeded (max. heating period for C25
wash and fill cycle). S02
Reset via machine "OFF-ON". S58
Possible cause Remedy
1. Booster heating defective. 1. Replace booster heating.
2. Missing phases. 2. Check phases (also at site).
3. Machine single-phase connected (230 V). 3. Connect to three-phase current if possible.
4. Tank heating defective (with termostop 4. Replace tank heating.
tank) parameter S58.
CH1 Chemical Detergent deficiency X12.3 "on" / rinse aid deficiency X12.4 "on".
deficiency If both containers are empty, CH1/CH2 is displayed alternately.
CH2
Possible cause Remedy
1. Chemical container empty / suction 1. Refill container / carry out hose priming.
hoses not filled.
2. Adjustment of chemical deficiency 2. Check settings (see chap. 7.3.2, page 17).
sensors not correct.
3. Missing electrical supply (X12.1/2). 3. Check voltage (X12.1 +5V, X12.2 0V) /
check crimp connection.
SAL Salt deficiency Softener salt deficiency indication – X13.5 "on" S05
(only if softener [S05] = "1").
Possible cause Remedy
1. Salt container empty. 1. Refill container with regeneration salt.
2. Float switch inside salt container 2. Loose the container a little and shake
jammed [S3]. slightly.
3. Loose contact on PCB (X13.5/6). 3. Check crimp connection and contacts.
F02 --1 Temperature probe Tank heating RL2 will be switched off immediately.
TANK B2 Fill and wash programs are locked, drain program can be started.
--2
Possible cause Remedy
1. - - 1 = short circuit (temperature probe 1. Check wires, replace temperature
or wires to probe). probe.
2. - - 2 = open circuit 2. Replace wiring, replace temperature
probe if necessary.
F03 --1 Pressure transmitter Control of input voltage X14.7 – min. 0.3V up to max. 4.0V.
BOOSTER B3 If the input voltage is out of range, the running program will be
--2 stopped.
Fill and wash programs are locked, drain program can be started.
Possible cause Remedy
1. - - 1 = short circuit (transmitter or wires 1. Check wires, replace transmitter B3.
to transmitter) / > 4.0V.
2. - - 2 = open circuit / < 0.3V. 2. Replace wiring, replace B3 if necessary.
F04 --1 Pressure transmitter Control of input voltage X14.10 – min. 0.3V up to max. 4.0V.
TANK B4 If the input voltage is out of range, the running program will be
--2 stopped.
Fill and wash programs are locked, drain program can be started.
Possible cause Remedy
1. - - 1 = short circuit (transmitter or wires 1. Check wires, replace transmitter B4.
to transmitter) / > 4.0V.
2. - - 2 = open circuit / < 0.3V. 2. Replace wiring, replace B4 if necessary.
--3 Pressure transmitter The max. water quantity [C82] is exceeded and value [F16] is not C82
TANK B4 / reached. Only "draining" possible. F16
SOFTENER
Possible cause Remedy
1. Air trap blocked or leaky. 1. Check air trap, clean or replace if
necessary.
2. Hose to pressure transmitter leaky. 2. Replace hose.
3. Valve Y4.2 locked (drain direction) or coil 3. Run Softener Test. Replace switching
defective. valve if necessary.
4. Extension board not correctly plugged to 4. Plug in correctly.
Main PCB.
To quit the fault: start drain program or reload machine program no. (U01 see page 23).
SIE STRAINER Reed-switch [S4] (X13.7) more than 5 seconds "off". S38
CONTROL Start of fill and wash programs is locked automatically.
Possible cause Remedy
1. Tank strainer is missing or not correctly 1. Put strainer correctly in place.
positioned.
2. Magnet at the strainer is missing. 2. Fit magnet.
3. Reed switch in wrong position. 3. Put reed switch in correct position.
4. Cable break. 4. Replace reed switch and cable.