P1PD Medium Pressure Axial Piston Pumps-HY28-2665-01 - P1 - EN

Download as pdf or txt
Download as pdf or txt
You are on page 1of 72

P1/PD Series

Medium Pressure Axial Piston Pumps


Variable Displacement
Catalog HY28-2665-01/P1/EN
Effective: April 2021 | Replaces September 2020
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Contents P1/PD Series

Contents
General Information & Technical Specs................................................................................................................... 3
Ordering Information................................................................................................................................................ 4
Shaft Technical Data................................................................................................................................................. 6
Design Series Change Information........................................................................................................................... 7
Control Options........................................................................................................................................................ 8
Performance Data
Typical Pump Outlet Flow................................................................................................................................ 17
Typical Shaft Input Power................................................................................................................................ 19
Typical Shaft Bearing Life................................................................................................................................ 22
Typical Noise Characteristics.......................................................................................................................... 24
Dimensional Data
P1/PD 018....................................................................................................................................................... 29
P1/PD 028....................................................................................................................................................... 33
P1/PD 045....................................................................................................................................................... 37
P1/PD 060....................................................................................................................................................... 41
P1/PD 075 & 085............................................................................................................................................. 46
P1/PD 100....................................................................................................................................................... 51
P1/PD 140....................................................................................................................................................... 56
Controls........................................................................................................................................................... 61
Installation Information........................................................................................................................................... 67
Conversions & Formulas........................................................................................................................................ 68
Offer of Sale........................................................................................................................................................... 70
Content Index......................................................................................................................................................... 71

WARNING - USER RESPONSIBILITY


FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation
by users having technical expertise.

The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,
maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is
responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

OFFER OF SALE
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributor. This offer and its acceptance
are governed by the provisions stated in the detailed "Offer of Sale" elsewhere in this document.

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
2 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
General Information & Technical Specs P1/PD Series

Description • Variable displacement, axial piston pump for open-circuit applications


• Continuous operation at pressures up to 280 bar
• High drive speed models for mobile markets and low noise models
for industrial markets
• Quiet and efficient control capability
• Cam bearing design
Benefits • Compact overall package size
• High power density
• Many different standard control options
• Modular controls for easy conversions
• High operating efficiency for lower power consumption and reduced heat generation
• Elastomer seals that eliminate gaskets and external leakage
• Simple hydraulic controls with “no-leak” adjustments
• Fast and stable compensator response
• SAE and ISO standard mounting flanges and ports
• Long life, roller shaft bearings
• Long life, low friction, hydrostatically balanced swash plate saddle bearings
• Full power through-drive capability
• Multiple case drain ports for various mounting orientations
• Optional minimum and maximum displacement adjustments
• Easy to service

Technical Data
Model P1/PD 018 P1/PD 028 P1/PD 045 P1/PD 060 P1/PD 075 P1/PD 085 P1/PD 100 P1/PD 140
Maximum Displacement, cm3/rev 18 28 45 60 75 85 100 140
cu.in./rev 1.10 1.71 2.75 3.66 4.58 5.19 6.01 8.54
280 bar 250 bar 280 bar
Outlet Pressure – Continuous
(4060 psi) (3600 psi) (4060 psi)
320 bar 300 bar 320 bar
Intermittent*
(4640 psi) (4350 psi) (4640 psi)
350 bar 320 bar 350 bar
Peak
(5075 psi) (4600 psi) (5075 psi)
P1 Maximum Speed (1.3 bar abs inlet), rpm 3500 3400 3100 2800 2700 2700 2500 2400
P1 (1.0 bar abs inlet), rpm 3300 3200 2800 2500 2400 2400 2250 2100
P1 (0.8 bar abs inlet), rpm 2900 2900 2400 2200 2100 2100 1900 1800
PD Maximum Speed (1.0 bar abs inlet), rpm 1800
PD (0.8 bar abs inlet), rpm 1800
Minimum Speed, rpm 600
Inlet Pressure – Maximum 11 bar absolute (160 psi)
Rated 1.0 bar absolute (14.5 psi)
Minimum 0.8 bar absolute (11.6 psi)
Case Pressure – Peak, bar 4.0 bar absolute (58 psi) and less than 0.5 bar (7.3 psi) above inlet pressure
Rated, bar 2.0 bar absolute (29 psi) and less than 0.5 bar (7.3 psi) above inlet pressure
Fluid Temperature Range, °C -40 to +95
°F -40 to +203
Fluid Viscosity – Rated, cSt 7 to 160
Optimum Range, cSt 14-50 cSt.
Max. Intermittent, cSt 5000 (for cold starting)
Min. Intermittent, cSt 5
Fluid Contamination – Rated, ISO 20/18/14
Weight – End Port, kg (lb) 13.4 (29.5) 17.7 (39.0) 23 (50) 29 (64) 30 (66) 30 (66) 51 (112) 66 (145)
Side Port, kg (lb) 14.2 (31.3) 18.1 (40.0) 24 (52) 30 (67) 31 (68) 31 (68) 53 (117) 67 (147)
Thru-Drive, kg (lb) 15 (34) 22 (48) 27 (59) 34 (75) 35 (77) 35 (77) 55 (121) 82 (180)
Moment of Inertia kg·mm2 760 1555 3208 4548 5041 5041 12027 21400
Moment of Inertia Thru-Drive, kg·mm2 793 1618 3268 4687 5207 5207 12402 22343
*Intermittent is defined as less than 10% of operation time, not exceeding 20 successive seconds.

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 3
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
P1/PD Model Ordering Code P1/PD Series

S 5 B
Pump Circuit Type Shaft Rotation Fluorocarbon Controls Port Work Port Paint
Family Options Seal Material Orientation Type
Displacement Mounting Single Configuration Design Additional Displacement Thru-Drive Special
& Ports Shaft Seal Series Control Options Stops Mounting Pad & Features
Coupling

Pump Family Rotation Port Orientation


P1 Mobile R Clockwise E End Ports
PD Industrial L Counterclockwise S Side Ports (60-140cc only)
R Side Ports with ripple chamber (18-45cc only)
Displacement Configuration
T Side Ports with thru-drive
018 18cc/rev M Mobile (P1)
028 28cc/rev S Industrial (PD) Displacement Stops5
045 45cc/rev U2 Universal (45-140cc only) 0 None
060 60cc/rev 2 Comes with torque limiter ports drilled in the housing 1 Adjustable maximum stop
075 75cc/rev 2 Adjustable minimum stop
Controls
085 85cc/rev 3 Adjustable maximum & minimum stop
C0 Pressure Limiter
100 100cc/rev 5 Not standard with thru drive. Contact factory for approval.
L0 Load sensing & pressure limiter
140 140cc/rev
L2 Load sensing with bleed & pressure limiter Work Port Type
AM Remote pressure limiter 0 Flanged (Not with 18cc "E" or "R" ports)
Circuit Type
AN Remote pressure limiter with D03 interface 26 Threaded (18-60cc only)
P Open Circuit - One Side of Center
AE Prop. Pressure limiter (Min default - 12VDC)
6 On 60cc, only with SAE end ports
Open Circuit - Overcenter
X
(45-75, 100-140cc with P, T, S, U controls only)
AF Prop. Pressure limiter (Min default - 24VDC) Thru-Drive Designation Description
Mounting & Ports AG3 Prop. Pressure limiter (Max default - 24VDC) 0 None
S SAE mount; SAE work & aux ports AH3 Prop. Pressure limiter (Max default - 12VDC)
A SAE 82-2 (A), 9T coupling
A SAE mount; Metric work ports; BSPP aux ports ## See below for electronic controls
H SAE 82-2 (A), 11T coupling
Voltage, ECU,
M ISO mount; Metric work & aux ports # Electronic Valve # SAE 101-2 (B), 13T coupling
& Sensor B
(28-140cc only)
B ISO mount; Metric work ports; BSPP aux ports D1FB (Min Default)
P 0 12 VDC; No ECU SAE 101-2 (B), 15T coupling
No Pmax override Q
2-bolt SAE C mount; SAE work & aux ports (28-140cc only)
C
(60-85cc only) SAE 127-4 (C), 14T coupling
D1FB (Max Default)
2-bolt SAE C mount; metric work ports; T M 24 VDC; No ECU (60cc only)
D No Pmax override C
BSPP aux ports (60-85cc only) SAE 127-2/4 (C), 14T coupling
2-bolt SAE-B mount; SAE work & aux ports D1FB (Min Default) (75-140cc only)
J S D 12 VDC; With ECU
(60cc only) With Pmax override SAE 127-4 (C), 17T coupling
N
2-bolt SAE-B mount; Metric work ports; (100 & 140cc only)
K D1FB (Max Default) 12 VDC; With ECU &
BSPP aux ports (60cc only) U Y SAE 152-4 (D), 13T coupling
With Pmax override Pressure Sensor D
(140cc only)

Shaft Options
3 Requires application review. Consult factory.
Paint
01 SAE Spline
Additional Control Options
00 No Paint
02 SAE Keyed 0 No other options
PB Black Paint
04 ISO Keyed 2 Cam sensor (mandatory with P, T, S, U controls)
061 SAE Spline (18 & 100cc only) 34 Unload Valve - 12VDC (C0 or L0 control only) Special Features
08 SAE-B 13T Spline (28 & 45cc only) 64 Unload Valve - 24VDC (C0 or L0 control only) 00 Standard
09 SAE-BB 15T Spline (60cc only) 4 210 bar pressure limit (AG or AH control only) M2 Special Designation
SAE-B 13T Spline
10 7 280 bar pressure limit (AG or AH control only)
(60cc only; Not with thru drive)
1 18cc de-rated to 210 bar Torque Limiter
T
(45-140cc only; L0, AM, AN control only)
4 Available on 28-140cc only

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
4 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Model Code Descriptions P1/PD Series

Mounting Designation Descriptions

Code Standard 18 28 45 60 75 & 85 100 140

S&A SAE J744 SAE-A 2-Bolt SAE-B 2-Bolt SAE-B 2-Bolt SAE-C 4-Bolt SAE-C 4-Bolt SAE-C 4-Bolt SAE-D 4-Bolt
ISO 80mm ISO 100mm ISO 100mm ISO 125mm ISO 125mm ISO 125mm ISO 180mm
M&B ISO 3019/2
2-Bolt 2-Bolt 2-Bolt 4-Bolt 4-Bolt 4-Bolt 4-Bolt

C&D SAE J744 N/A N/A N/A SAE-C 2-Bolt SAE-C 2-Bolt N/A N/A

J&K SAE J744 N/A N/A N/A SAE-B 2-Bolt N/A N/A N/A

Shaft Descriptions

Code 18 28 45 60 75 & 85 100 140


SAE-BB 15T SAE-BB 15T SAE-CC 17T
01 SAE 11T spline SAE-C 14T spline SAE-C 14T spline SAE-D 13T spline
spline spline spline

02 SAE 19mm keyed SAE-BB keyed SAE-BB keyed SAE-C keyed SAE-C keyed SAE-CC keyed SAE-D keyed

04 ISO 20mm keyed ISO 25mm keyed ISO 25mm keyed ISO 32mm keyed ISO 32mm keyed ISO 40mm keyed DIN 50mm keyed

06 SAE-A 9T spline N/A N/A N/A N/A SAE-C 14T spline N/A

08 SAE-B 13T spline SAE-B 13T spline SAE-B 13T spline N/A N/A N/A N/A

09 N/A N/A N/A SAE-BB 15T spline N/A N/A N/A

10 N/A N/A N/A SAE-B 13T spline N/A N/A N/A

Maximum Flange Moment Ratings

Moment M = (L1*W1+L2*W2+L3*W3...) ÷ 102

P1/PD Displacement

Measurement Units 18 28 45 60 75 85 100 140

Maximum Static Moment Nm 500 650 1000 1200 1600 1600 2200 3200

Maximum Dynamic Moment


Nm 50 65 100 120 160 160 220 320
(at 10g acceleration)

Distance L1 (no thru drive) mm 73 93 107 110 119 119 154 154

Distance L1 (thru drive) mm 104 113 115 123 134 134 179 185

Distance Lp mm 199 233 229 253 264 264 340 364

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 5
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Shaft Loading Information P1/PD Series

Shaft Torque Ratings

Units 18 (1.1) 28 (1.71) 45 (2.75) 60 (3.66) 75 (4.58) 85 (5.19) 100 (6.1) 140 (8.54)

Nm 134 337 337 641 641 641 1217 1701


01
ft.lbs 99 249 249 473 473 473 898 1255
Nm 130 357 357 559 559 559 1134 1732
02
ft.lbs 96 264 264 413 413 413 837 1278
Nm 113 337 337 576 576 576 1157 1708
04
ft.lbs 84 249 249 425 425 425 854 1260
Maximum Nm 58 641
Input shaft 06 N/A N/A N/A N/A N/A N/A
torque ft.lbs 43 473
Nm 209 209
08 N/A N/A N/A N/A N/A N/A
ft.lbs 155 155
Nm 337
09 N/A N/A N/A N/A N/A N/A N/A
ft.lbs 249

Nm 209
10 N/A N/A N/A N/A N/A N/A N/A
ft.lbs 155
Maximum Nm 134 210 293 318 329 329 538 760
through-drive
shaft torque ft.lbs 99 155 217 235 243 243 397 561

Radial and Axial Shaft Load Ratings


Radial Load Diagram Axial Load Diagram

Fq Maximum Allowable Shaft Load


018 028 045 060 075 085 100 140
N 700 1,000 1,500 1,800 1,900 1,900 2,300 2,600
±F ax Radial Force
(At X/2) lbf 160 229 343 411 434 434 526 594
X/2 X/2 N 1,900 1,900 2,500 2,300 2,300 2,300 3,100 4,200
Axial Force
X lbf 434 434 571 526 526 526 709 960

Shaft Rotational Stiffness

Shaft 018 028 045 060 075/085 100 140


Units
Designation NRD RD NRD RD NRD RD NRD RD NRD RD NRD RD NRD RD
ft-lb/Rad 4,332 3,475 7,712 6,458 11,681 10,540 18,198 15,397 20,615 16,838 31,080 25,479 47,819 43,970
01
Nm/Rad 5,848 4,691 10,411 8,718 15,769 14,229 24,567 20,786 27,830 22,731 41,958 34,397 64,556 59,360
ft-lb/Rad 5,082 4,363 7,317 7,293 11,040 6,179 17,828 14,905 16,061 15,661 28,607 23,793 48,994 40,954
02
Nm/Rad 6,861 5,890 9,878 9,846 14,904 8,342 24,068 20,122 21,682 21,142 38,619 32,121 66,142 55,288
ft-lb/Rad 4,468 3,903 7,011 5,958 9,362 8,715 16,771 14,006 14,994 14,646 25,529 21,625 53,685 44,181
04
Nm/Rad 6,032 5,269 9,465 8,043 12,639 11,765 22,641 18,908 20,242 19,772 34,464 29,194 72,475 59,644
ft-lb/Rad 2,972 2,846 26,806 22,533
06 N/A N/A N/A N/A N/A
Nm/Rad 4,012 3,842 36,188 30,420
ft-lb/Rad 5,699 5,044 7,320 6,180 10,124 9,255
08 N/A N/A N/A N/A
Nm/Rad 7,694 6,809 9,882 8,343 13,667 12,494
ft-lb/Rad 16,615 13,370
09 N/A N/A N/A N/A N/A N/A
Nm/Rad 22,430 18,050
ft-lb/Rad 11,696 10,472
10 N/A N/A N/A N/A N/A N/A
Nm/Rad 15,790 14,137
NRD = No rear thru drive; RD = Rear thru drive

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
6 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Design Series Change Information P1/PD Series

The P1/PD has gone through a design series change for some control options. All the controls shown in this catalog are now
standard as Design Series B (B-mod). For the C, L, and AM controls, the controls were combined into a single universal control
housing that can be used for any of the three options. See details below. Therefore, converting between those controls is very
easy. For conversion details or other service information on the B-mod, please refer to the P1/PD B-mod Service Manual HY28-
2708-02/SVC/EN. For service information on the Design Series A (A-mod), please refer to HY-28-2665-02/SVC/EN. Both service
manuals and all of the most recent P1/PD literature can be found at www.parker.com or directly at the Hydraulic Pump and
Power Systems Division homepage (www.parker.com/HPS).

Design Series A (C, L, & AM Controls) Design Series B (C, L, & AM Controls)

Pressure Limiter: Pressure Limiter:


C00, C10 (CCW) C00, C10 (CW)

Pressure sense: Pressure sense:


L00, L20 (CCW) L00, L20 (CW)
"All in one compensator":
C00, (C00 replaces C10) L00,
L20, AM (CCW and CW)

Pilot operated Pilot operated


pressure limiter: pressure limiter:
AM (CCW) AM (CW)

Tank
Pressure LS
Pressure

Bias or
Control
Control
or Bias

Pressure
Pmax

Tank Control
Standard NG6/D03 Pattern Custom Control Pad Pattern

NOTE: Bolt pattern & size remains the same. No change to housing casting required.

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 7
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Controls Information P1/PD Series

Control Option “C” Control Option “L”


Pressure Limiter Load Sensing and Pressure Limiter
Adjustment Range = 26-280 bar (380-4060 psi) Pressure Limiter Adjustment Range = 26-280 bar (380-4060 psi)
Differential Adjustment Range = 10-40 bar (150-580 psi)

The "C0" pressure limiter control is used to limit the The "L0" and "L2" controls feature load sensing and
maximum system pressure. The control acts such that full maximum pressure compensation. A load sense line that
pump displacement is achieved unless the system valve comes from downstream of the main system throttling valve
restricts the output flow or the load pressure reaches the is connected to the "X" port on the control. This control
maximum setting of the control. If pump flow is restricted matches pump flow and pressure to system demands
by the system valve, the pump will provide only the flow by maintaining a constant pressure drop across the main
demanded, but at the maximum pressure setting of the system throttling valve, thus reducing horsepower losses.
compensator control. If the outlet flow is completely blocked, The pump automatically adjusts for changes in drive speed
the pump will destroke to zero displacement and maintain and load pressures. Choose the "L2" option if bleeding the
the pressure at the setting of the compensator spring. load sense line at the pump is desired.

pressure limiter control load sensing and pressure limiter control

4 bar maximum 4 bar maximum

flow
flow

pressure pressure

C0 Schematic L0 Schematic

Typical Control Response Time (ms)


Control Description Pump Operating Condition 018 028 045 060 075/085 100 140
Maximum Displacement to Zero 25 25 25 37 21 26 30
"C" Pressure Limiter
Zero Displacement to Maximum 80 80 106 119 89 108 125
Maximum Displacement to Zero 40 40 30 54 40 43 45
“L” Load Sensing
Zero Displacement to Maximum 70 70 120 186 97 189 280
* Based on NFPA testing standards

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
8 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Controls Information P1/PD Series

Control Options “AM” Control Option “AN”


Remote Operated Pressure Limiter Pilot Operated Control with ISO 4401 NG6
Interface for Customer Added Pressure Limiter

The "AM" control allows the pump pressure compensator The "AN" control is a standard pressure compensator, but
setting to be adjusted from a remote relief valve that is with a NG6 ( D03) valve interface. It is the same as the "AM"
connected to the "X" port on the control. The control acts control, but with the addition of an adapter block mounted
such that full pump displacement is achieved unless the between the pump housing and control to provide the NG6
system valve restricts the output flow or the load pressure (D03) interface. This allows a directional valve or proportional
relief valve to be mounted directly on the pump to achieve a
reaches the maximum setting of the control. If pump flow is
variety of pressure control circuits.
restricted by the system valve, the pump will provide only the
flow demanded, but at the maximum pressure setting of the Caution: Pumps shipped with the “AN” control need to have
compensator control. If the outlet flow is completely blocked, a valve mounted to the NG6 interface for operation. This is
the pump will destroke to zero displacement and maintain not a functional control as shipped.
the pressure at the setting of the remote relief valve.
pilot-operated pressure limiter control pilot-operated control

4 bar maximum
flow

flow

pressure pressure

AM Schematic AN Schematic

Typical Control Response Time (ms)


Control Description Pump Operating Condition 018 028 045 060 075/085 100 140
Maximum Displacement to Zero 25 25 46 43 37 39 40
“A” Pilot Operated Control
Zero Displacement to Maximum 80 80 131 125 115 123 130
* Based on NFPA testing standards

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 9
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Controls Information P1/PD Series

Control Options “AMT,” “ANT,” and “L0T”


Torque Limiting Controls: (45-140cc only)
AMT = Remote pressure limiting with torque limiting
ANT = Pilot operated pressure limiting with torque limiting
L0T = Load sense & pressure limiting with torque limiting
These controls provide the benefit of pressure limiting "L0T" Control
control, plus the ability to limit the input torque when the The "L0T" combines the functions of a pressure limiter, load
power available from the prime mover is limited; or when sense and torque limiter control. The pressure limiter function
the application power demand has both high flow/low limits the maximum pump outlet pressure. The load sense
pressure and low flow/high pressure operating conditions. control function requires the "X" port to be connected to the
highest load pressure via a load sense signal line. The control
“AMT” & "ANT" Control will match pump output flow and pressure to the system
The "AMT" and "ANT" combine the pilot pressure limiter demand , thus minimizing horsepower losses. The pump will
function with a torque limiting function. On the "AMT" operate in a load sense mode until the torque limiter setting
control, the pressure limiter function is controlled remotely is reached, and then the pump will maintain the input torque
by connecting an external relief valve to the "X" port. On the at the pre-selected setting. If the system pressure reaches
"ANT" control, the pilot relief valve is mounted directly on the pressure compensator setting, then the pump flow will
the pump via the NG6 interface on the control block. Once be lowered to the level needed to maintain the maximum
the torque limiter setting is reached, the pump will destroke pressure setting.
as pressure continues to rise in order to maintain the same
input torque. Once the pressure limiter setting is reached,
the pump will destroke to limit the system pressure. P1/PD*** with TORQUE LIMITER
TYPICAL DISPLACEMENT vs SYSTEM PRESSURE CURVE
Caution: The ANT control will not function without a 1800 RPM
120
valve mounted on the NG6 interface.
100
Displacement - %

80

60

25% Torque Setting


40

50% Torque Setting


20
75% Torque Setting

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
(35) (69) (105) (138) (174) (207) (243) (276) (316)
System Pressure- psi(bar)

AMT Torque Limiter ANT Torque Limiter L0T Torque Limiter

P1/PD*** with TORQUE LIMITER


TYPICAL DISPLACEMENT vs SYSTEM PRESSURE CURVE P1/PD*** with TORQUE LIMITER
1800 RPM TYPICAL PERCENT of FULL TORQUE vs SYSTEM PRESSURE CURVE
120
1800 RPM
100

90
100
75% Torque Setting
80 75%
Displacement - %

80 70
Full Torque - %

60
60 50 %
50

25% Torque Setting 40 50% Torque Setting


40
30 25%
50% Torque Setting
20
20
25% Torque Setting
75% Torque Setting
10

0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 0 500 1000 1500 2000 2500 3000 3500 4000 4500
(35) (69) (105) (138) (174) (207) (243) (276) (316) (35) (69) (105) (138) (174) (207) (243) (276) (316)
System Pressure- psi(bar) System Pressure- psi(bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
10 United States

P1/PD*** with TORQUE LIMITER


TYPICAL PERCENT of FULL TORQUE vs SYSTEM PRESSURE CURVE
1800 RPM
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Controls Information P1/PD Series

Control Options “AE” and “AF”


Electronic Proportional Pressure Limiting with Mechanical Pressure Limiter
Minimum Pressure Default
AE = 12 VDC Solenoid
AF = 24 VDC Solenoid

This control is the same as the AN control, but with Note: The pressure relief valve has a command
the proportional relief valve included. It allows the range up to 350 bar, but P1/PD pump is rated to
pump pressure compensator setting to be adjusted 280 bar continuous pressure.
by an on-board 4VP0150G24B1C1 (24V) or
RE06M35W2N1KWXG087 (12V) proportional, electronic The following are options to drive the
relief valve. The control acts such that full pump proportional valve on the AE or AF pump:
displacement is achieved unless the system pressure
Parker Part# Description
reaches the setting of the proportional relief valve or the
027-22071-0 Dual Driver Module (12/24V)
mechanical pressure limiter. If pump flow is restricted
027-22067-0 Plug-Top-Driver 12V (0-10V command)
by the system, the pump will provide only the flow
027-22066-0 Plug-Top-Driver 24V (0-10V command)
demanded, but at the pressure setting of the proportional
or mechanical control. If the outlet flow is completely
Note: Consult Factory for more driver options and information.
blocked, the pump will destroke to zero displacement
and maintain the pressure at the setting of the control.

The proportional relief valve defaults to minimum


displacement, so if no current is going to relief valve,
then the pump goes to minimum displacement at a low
pressure stand-by condition. Furthermore, as current
to the proportional relief valve increases, the pressure
setting of proportional relief valve increases.
pilot-operated pressure limiter control

4 bar maximum
flow

pressure

Pressure vs. Input Current


PSI Bar
5075 350

4350 300
Electric Characteristics
3625 250
RE06 4VP01
Pressure

Voltage 12VDC 24VDC 2900 200

Coil Resistance 4 Ohms 25 Ohms 2175 150


Max current 2.3 A 800mA
1450 100
Connector DIN 43650 Plug-in per ISO 4400
725 50
Protection Class IP65 IP65
0
0 20 40 60 80 100
Command Signal (%)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 11
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Controls Information P1/PD Series

Control Options “C03,” “C06,” “L03,” “L06”


Electronic Unload/Cold Start
C03 = Pressure limiting with 12VDC unload valve
C06 = Pressure limiting with 24VDC unload valve
L03 = Load sense & pressure limiting with 12VDC unload valve
L06 = Load sense & pressure limiting with 24VDC unload valve

This control contains a cartridge valve that is integrated into “L03” & “L06” Controls - Load sensing &
the pump control to unload the pump into a low pressure pressure limiting with unload function
stand-by condition in order to reduce the torque required When the unload valve is in the spring position
to turn the pump. This control is often used in cold start (de-energized), the pump is “loaded”. The load sense
conditions when the hydraulic fluid is very cold and viscous. function requires the signal port be connected to load
The high fluid viscosity causes the pump to require more pressure, and the valve sends the load pressure to the
torque when initially starting, so this option can be used to spring side of the differential spool, so that a pressure
de-stroke the pump upon start-up in order to reduce the differential is created between the spring side of the
torque load on the engine to prevent it from stalling. spool and the system side allowing the control to
function like a standard load sensing control.
“LOADED” CONDITION
“C03” & “C06” Controls - Pressure limiting “UNLOADED” CONDITION
with unload function When the unload valve is in the energizes, the pump is
When the unload valve is in the spring position “unloaded”. This means the valve dumps the pressure
(de-energized), the pump is “loaded”. This means the valve on the spring side of the differential spool, activating that
sends system pressure to the spring side of the differential spool which sends pressure to the control piston of the
spool, so that pressure on both sides of that spool is equal. pump and allows the pump to de-stroke into a low pressure
Therefore, the spring setting prevents the differential spool stand-by condition.
from moving, so only the Pmax spool is active. Thus the
control behaves just like a standard pressure limiting control.

C0* Pressure Compensator Control L0* Load Sense Control


with Unloading Valve with Unloading Valve

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
12 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Controls Information P1/PD Series

Control Options “AG” and “AH”


Electronic Proportional Pressure Limiting with Mechanical Pressure Limiter
Full Pressure Default
AG = 24 VDC
AH = 12 VDC

This control contains a Parker AP02B2YR35ALV proportional The proportional relief valve defaults to maximum
electronic pressure relief cartridge valve and mechanical displacement, so if no current is going to the valve then the
pressure limiter that are integrated into the pump control to pump goes to full displacement until the pressure setting
limit the maximum pressure of the pump either electronically of the mechanical pressure limiter is reached. Furthermore,
or mechanically. as current to the proportional relief valve is increased, the
pressure setting of the proportional relief decreases. This type
The control acts such that full pump displacement is of can is often used in fan drive applications so that maximum
achieved until the system pressure reaches the setting of cooling is achieved in the event of control signal loss.
the proportional relief or mechanical pressure limiter. If pump
flow is restricted by the system, the pump will provide only Note: For the "A*7" option, the pressure relief valve has a
the flow demanded, but at the pressure of the control setting. command range up to 350 bar, but P1/PD pump is rated
If the outlet flow is blocked, the pump will de-stroke to to 280 bar continuous pressure.
minimum displacement and maintain the pressure of the
control setting.

pilot-operated pressure limiter control

4 bar maximum
flow

pressure

A*7 Pressure vs. Input Current


PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
5000 345
Electric Characteristics Measured at coil stabilized
temperature and nominal flow
Coil Power 28 W* 4000 274

Coil Resistance 5.1 Ohms (12 VDC)


3000 205
Pressure

20.6 Ohms (24 VDC)


Max current 2.33 A (12 VDC) 2000 137
1.17 A (24 VDC)
PWM Signal 100-250 Hz (recommended) 1000 68

Hysteresis < 10%


0
Connection Deutsch DT04-2P (IP 67) 0
20 40 60 80 100

*18 W coils available on request Input Current (%)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 13
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Controls Information P1/PD Series

Control Options “P,” “T,” “S,” “U”


Electronic Proportional Displacement & Pressure Limiting
P = Min displacement default*
T = Max displacement default*
S = Min displacement default and hydromechanical pressure limiter
U = Max displacement default and hydromechanical pressure limiter
*Pumps without pressure limiter should be designed in a circuit with other means of pressure limitation.

The control uses the D1FB electronic proportional valve Cables are not included with the pump but
from Parker's Hydraulic Valve Division to provide the precise needed when ECU is purchased:
flow specified per a displacement input command and • 12-pin connector cable needed
maintain that flow level until a new displacement command • 6-pin connector cable needed
level is received, or until the pressure command overrides to • Com cable assembly
limit system pressure.
Parameters adjustment, calibration info and Interface
The holding current can vary from pump to pump, but is between ECU and Pump are described in the
typically between 1.3-1.6 Amps for the 12V valve and "Electronic Controls - Graphical User Interface
700-800 mA for the 24V valve. User Guide HY28-2674-01/P1/US"
A minimum of 25 bar servo pressure is required to control
the pump. To control the pump at system pressure below
25 bar, either a sequence valve in the pressure line or an
external servo source is required. Without adequate servo
pressure, the pump is biased on stroke.

An Electronic Control Unit (ECU) module can be provided


with the pump with analog or CANBUS control capability.
Additionally preset control values can be selected via a
RS232/USB connection using GUI software available on
Parker Hannifin’s website.

The mechanical pressure limiter will override the electronic


inputs and limit pump outlet pressure to the preset level.

Using electronic control, the pump can be used in


overcenter condition. (Energy recovery is one example
of application for this.)

Electronic Proportional Valve Information


Parameter 12 VDC 24 VDC
Resistance @ 20 C 4.4 Ohm 18.6 Ohm
Max Current 2.7 A 1.3 A
PWM Signal 100-250 Hz
Typical Hysteresis* <2%
"S" Control Schematic
Connector Deutsch DT04-2P
Protection Class IP66
Displacement Sensor Wiring
*Good results found with superimposed dither amplitude of +/- 200 mA for
12V valve and +/- 100 mA for 24V valve DT04-3P Deutsch Connector
Wire color Pin # Signal
Typical Control Response Times Red A +5VDC
Black B 0VDC
Response time (ms)
Blue C 0 to 5VDC
Displacement (cc) 18 28 45 60 75/85 100 140
For CW: For CCW:
Max to zero 40 40 43 63 96 101 109 Full stroke = 0.56VDC Full stroke = 4.44VDC
35 35 36 52 72 77 84 Zero stroke = 2.5VDC Zero stroke = 2.5VDC
Zero to max
100% overcenter = 4.44VDC 100% overcenter = 0.56VDC

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
14 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Controls Information P1/PD Series

Electronic Control Unit


General ECU Information 12 Pin Connector 6 Pin Connector
Temperature: -40C to +85C PIN Designation Type Signal PIN Designation Type Signal
Protection: Outdoor Use IP65 1 Coil High Input / Output PWM 1 RS232 Receive Input / Output –
Supply: 9 to 36 VDC 2 Power Input +9 to 36VDC 2 RS232 Ground Output –
Data Interface Type: CANJ1939
3 Pump Enable Input +9 to 36VDC 3 CANBUS Low Input / Output –
4 Source Output +5VDC 4 CANBUS High Input / Output –

5* Displacement 0 to 5VDC 5 Chassis Ground Output 0VDC


12 PIN Unshielded Control
Command Input or 4 to 20mA Cable ASSY, S2E-19179-0,
6 RS232 Transmit
Ordered Separately. Input –
6* Pressure 0 to 5VDC Not all Conductors Shown.
Command Input or 4 to 20mA Cable Length, 10ft.
12 PIN Unshielded Control
7* Torque Command Input 0 to 5VDC
Cables Available
Cable ASSY, S2E-19179-0,
Ordered Separately.
8 Pressure Signal Input 0 to 5VDC Not all Conductors Shown.
Cable Length, 10ft.
Displacement
9 Input 0 to 5VDC 12 PIN Unshielded Control
Signal Cable ASSY, S2E-19179-0,
Scale 0.3 Ordered Separately.
Scale 0.3 10 Signal Ground Input 0 VDC
Scale 0.3 11 Power Ground Input 0 VDC
Not all Conductors Shown.
Cable Length, 10ft.
6 PIN Unshielded CANBUS
74.3 12 Coil Low Input / Output PWM and Communication Cable
ASSY, S2E-19259-0,
Ordered Separately,
134.5 74.3 *10k ohm's minimum resistor suggested 10ft Length
134.5 6 PIN Unshielded CANBUS
2X Enlarged view of the and Communication Cable
Ø 2X
3.7
74.3 Ø 3.7
Dip Switches Configuration ASSY, S2E-19259-0,
Ordered Separately,
10ft Length
134.5 101.6
6 PIN Unshielded CANBUS
and Communication Cable
ASSY, S2E-19259-0,
101.6
118.0 Ordered Separately,
2X 118.0
CONNECTOR A
10ft Length

Ø 3.7 CONNECTOR
CONNECTORB A RS232
CONNECTOR B Communication Cable
ASSY S2E-19180-0
35.3 Ordered Separately
35.3
16.0 MOUNTING RS232
HOLE HEIGHT Communication Cable
16.0 MOUNTING
101.6
HOLEController
RDEC HEIGHT ASSY S2E-19180-0
Ordered Separately
Dimensions for Reference Only
RDEC Controller
118.0
S2E-19254-0
Dimensions for Reference Only RS232
S2E-19254-0 Communication Cable
ASSY S2E-19180-0
CONNECTOR A Ordered Separately

CONNECTOR B

35.3

16.0 MOUNTING
HOLE HEIGHT

RDEC Controller
Dimensions for Reference Only
S2E-19254-0

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 15
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Notes P1/PD Series

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
16 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

P1/PD Series Typical Pump Outlet Flow


PD Maximum Speed Rating = 1800 rpm

P1/PD 018 Outlet Flow - Full Stroke P1/PD 028 Outlet Flow - Full Stroke
50c inlet oil temperature - ISO VG32 fluid 50c inlet oil temperature - ISO VG32 fluid
70 90
3200 rpm
80
60 2800 rpm
3200 rpm
70
2400 rpm
50 2800 rpm
Pump outlet flow (lpm)

Pump outlet flow (lpm)


60 2100 rpm
2400 rpm
40 50 1800 rpm
2100 rpm
1500 rpm
30 1800 rpm 40
1200 rpm
1500 rpm
30
20 1200 rpm 800 rpm
20
800 rpm
10
10

0
0
0 50 100 150 200 250 300
0 50 100 150 200 250 300
Pump outlet pressure (bar)
Pump outlet pressure (bar)

P1/PD 045 Outlet flow - Full Stroke P1/PD 060 Outlet Flow - Full Stroke
50c inlet oil temperature, ISO VG32 fluid 50 C inlet oil temperature - ISO VG32 fluid - maximum displacement
130 150
2800 rpm 2400 rpm
120 140

130
110
2400 rpm
120
100
Pump outlet flow (lpm)

Pump outlet flow (lpm)

2100 rpm 110


90 1800 rpm
100
1800 rpm
80
90
1500 rpm
70
1500 rpm 80

60
70 1200 rpm
1200 rpm
50
60

40 50
800 rpm 800 rpm
30 40
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 17
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

P1/PD Series Typical Pump Outlet Flow


PD Maximum Speed Rating = 1800 rpm

P1/PD 075 Outlet Flow - Full Stroke P1/PD 085 Outlet Flow - Full Stroke
50 C inlet oil temperature - ISO VG32 fluid - maximum displacement 50 C inlet oil temperature - ISO VG 32 fluid - maximum displacement
180 200
2400 rpm 2400 rpm
170

160 180

150
160

Pump outlet flow (lpm)


Pump outlet flow (lpm)

140
1800 rpm
130 1800 rpm
140
120
1500 rpm
110
1500 rpm
120
100

90 1200 rpm
100 1200 rpm
80

70 80
800 rpm
60 800 rpm
50 60
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)

P1/PD 100 Outlet Flow - Full Stroke P1/PD 140 Outlet Flow - Full Stroke
50 C inlet oil temperature - ISO VG 32 fluid - maximum displacement 50 C inlet oil temperature - ISO VG 32 fluid - maximum displacement
220 300
2100 rpm
2100 rpm
280
200
260
180 1800 rpm 1800 rpm
240
Pump outlet flow (lpm)

Pump outlet flow (lpm)

160
220
1500 rpm
1500 rpm
140 200

120 180
1200 rpm
1200 rpm
160
100
140
80 800 rpm
120
800 rpm
60 100
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
18 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

P1/PD Series Typical Shaft Input Power


PD Maximum Speed Rating = 1800 rpm

P1/PD 018 P1/PD 018


shaft input power at zero outlet flow shaft input power at maximum displacement
50 C inlet oil temperature - ISO VG 32 fluid 50 C inlet oil temperature - ISO VG 32 fluid
5.0 35

4.5
30
4.0

25
Shaft input power (kW)

3.5

Shaft input power (kW)


3200 rpm
3.0
20 2800 rpm
2.5 2100 rpm

15 1800 rpm
2.0 3200 rpm
1500 rpm
2800 rpm
1.5 1200 rpm
2100 rpm 10
800 rpm
1.0 1800 rpm

1500 rpm 5
0.5
800 rpm
0.0
0 50 100 150 200 250 300 0
0 50 100 150 200 250 300
Pump outlet pressure (bar)
Pump outlet pressure (bar)

P1/PD 028 P1/PD 028


shaft input power at zero outlet flow shaft input power at maximum displacement
50 C inlet oil temperature - ISO VG 32 fluid 50 C inlet oil temperature - ISO VG 32 fluid
6.0 50.0

5.5
45.0
5.0
40.0
4.5
Shaft input power (kW)
Shaft input power (kW)

35.0 3200 rpm


4.0
2800 rpm
3.5 30.0
2100 rpm
3.0 25.0 1800 rpm

2.5 20.0 1500 rpm


3200 rpm
2.0 1200 rpm
2800 rpm 15.0
800 rpm
1.5 2100 rpm
10.0
1800 rpm
1.0
1500 rpm 5.0
0.5
800 rpm
0.0 0.0
0 50 100 150 200 250 300 0 50 100 150 200 250 300

Pump outlet pressure (bar) Pump outlet pressure (bar)

P1/PD 045 P1/PD 045


shaft input power at zero outlet flow shaft input power at maximum displacement
50 C inlet oil temperature - ISO VG 32 fluid 50 C inlet oil temperature - ISO VG 32 fluid
10 70

9
60

8
50
Shaft input power (kW)
Shaft input power (kW)

7
2600 rpm
6 40
2400 rpm
5 1800 rpm
2600rpm 30
4 1500 rpm
2400rpm 1200 rpm
3 20
1800rpm 800 rpm
2 1500rpm
10
1200 rpm
1
800 rpm
0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 19
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

P1/PD Series Typical Shaft Input Power


PD Maximum Speed Rating = 1800 rpm

P1/PD 060 P1/PD 060


shaft input power at zero outlet flow shaft input power at maximum displacement
50 C inlet oil temperature - ISO VG 32 fluid 50 C inlet oil temperature - ISO VG 32 fluid
14 90

80 2400 rpm
12

70
10
Shaft input power (kW)

Shaft input power (kW)


60 1800 rpm

8 1500 rpm
50

40 1200 rpm
6

2400 rpm
30 800 rpm
4 1800 rpm

1500 rpm 20
2
1200 rpm
10
800 rpm
0
0
0 50 100 150 200 250 300
0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)

P1/PD 075 P1/PD 075


shaft input power at zero outlet flow shaft input power at maximum displacement
50 C inlet oil temperature - ISO VG 32 fluid 50 C inlet oil temperature - ISO VG 32 fluid
14 90

80
12 2300 rpm

70
10
Shaft input power (kW)

Shaft input power (kW)

1800 rpm
60

8 1500 rpm
50

40 1200 rpm
6

2300 rpm 30
800 rpm
4 1800 rpm
20
1500 rpm
2 1200 rpm
10
800 rpm
0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)

P1/PD 085 P1/PD 085


shaft input power at zero outlet flow shaft input power at maximum displacement
50 C inlet oil temperature - ISO VG 32 fluid 50 C inlet oil temperature - ISO VG 32 fluid
14 90
2300 rpm
80
12
1800 rpm
70
10
Shaft input power (kW)

Shaft input power (kW)

60 1500 rpm

8 50 1200 rpm

6 40
800 rpm
2300 rpm 30
4
1800 rpm
20
1500 rpm
2
1200 rpm 10
800 rpm
0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
20 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

P1/PD Series Typical Shaft Input Power


PD Maximum Speed Rating = 1800 rpm

P1/PD 100 P1/PD 100


shaft input power at zero outlet flow shaft input power at maximum displacement
50 C inlet oil temperature - ISO VG 32 fluid 50 C inlet oil temperature - ISO VG 32 fluid
16 120

14 2100 rpm
100
2100 rpm
1800 rpm
12
1800 rpm
Shaft input power (kW)

Shaft input power (kW)


80
1500 rpm 1500 rpm
10
1200 rpm
1200 rpm
8 800 rpm 60

6
40 800 rpm

20
2

0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)

P1/PD 140 P1/PD 140


shaft input power at zero outlet flow shaft input power at maximum displacement
50 C inlet oil temperature - ISO VG 32 fluid 50 C inlet oil temperature - ISO VG 32 fluid
18 160
2000 rpm
16 1800 rpm 140 2000 rpm

14 1500 rpm 1800 rpm


120
1200 rpm
Shaft input power (kW)

Shaft input power (kW)

12
1500 rpm
800 rpm 100
10
80 1200 rpm
8

60 800 rpm
6

4 40

2 20

0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 21
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

P1/PD Series Typical Shaft Bearing Life


PD Maximum Speed Rating = 1800 rpm

P1/PD 018 Shaft Bearing L-10 Life (Max Displacement) P1/PD 028 Shaft Bearing L-10 Life (Max Displacement)
1,000,000 1,000,000

P1/PD 018 Shaft B


30,000
1200 rpm

1500 rpm
Shaft bearing L-10 life (hours)

Shaft bearing L-10 life (hours)


25,000
100,000 3200 rpm 100,000 1800 rpm

Shaft bearing L-10 life (hours)


20,000
2400 rpm
3000 rpm

2400 rpm 15,000


1800 rpm
10,000 10,000

1500 rpm 10,000

1200 rpm
5,000
1,000 1,000
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Duty cycle average pump outlet pressure (bar) Duty cycle average pump outlet pressure (bar) 0
0 50 100
Duty cycle av

P1/PD 045 Shaft Bearing L-10 Life (Max Displacement) P1/PD 060 Shaft Bearing L-10 Life (Max Displacement)
1,000,000 1,000,000

2400 rpm

1800 rpm
Shaft bearing L-10 life (hours)

Shaft bearing L-10 life (hours)

100,000 1200 rpm 100,000 1500 rpm

1200 rpm

1500 rpm
10,000 10,000
1800 rpm

2600 rpm

1,000 1,000
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Duty cycle average pump outlet pressure (bar) Duty cycle average pump outlet pressure (bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
22 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

P1/PD Series Typical Shaft Bearing Life


PD Maximum Speed Rating = 1800 rpm

P1/PD 075 P1/PD 085


shaft bearing B-10 life at maximum displacement shaft bearing B-10 life at maximum displacement
1,000,000 1,000,000

Shaft bearing B-10 life (hours)


Shaft bearing B-10 life (hours)

100,000 2300 rpm 100,000

1800 rpm 2300 rpm

1500 rpm 1800 rpm

1200 rpm 1500 rpm


10,000 10,000
1000 rpm 1200 rpm

600 rpm 1000 rpm

600 rpm

1,000 1,000
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Duty cycle average pump outlet pressure (bar) Duty cycle average pump outlet pressure (bar)

P1/PD 100 P1/PD 140


shaft bearing B-10 life at maximum displacement shaft bearing B-10 life at maximum displacement
1,000,000 1,000,000
Shaft bearing B-10 life (hours)
Shaft bearing B-10 life (hours)

100,000 100,000
600 rpm 2000 rpm

1000 rpm 1800 rpm

1200 rpm
1500 rpm
1500 rpm
10,000 10,000 1200 rpm
1800 rpm
1000 rpm

2100 rpm
600 rpm

1,000 1,000
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Duty cycle average pump outlet pressure (bar) Duty cycle average pump outlet pressure (bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 23
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

P1 Series Typical Noise Characteristics


(These are anechoic sound pressure readings)

P1 018 Sound Levels (Zero Flow) P1 018 Sound Levels (Full Flow)
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
90 90

85 85

80 80
Sound pressure level dB(A)

Sound pressure level dB(A)


3000 rpm

75 3000 rpm 75

2100 rpm
70 2100 rpm 70

1000 rpm
65 65
1000 rpm
60 60

55 55

50 50
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)

P1 028 Sound Levels (Zero Flow) P1 028 Sound Levels (Full Flow)
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
90 90

85 85

80 80
Sound pressure level dB(A)

Sound pressure level dB(A)

3000 rpm
75 3000 rpm 75

70 70 2100 rpm
2100 rpm

65 65
1000 rpm 1000 rpm

60 60

55 55

50 50
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)

P1 045 Sound Levels (Zero Flow) P1 045 Sound Levels (Full Flow)
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
85 83

2600 rpm 81
2600 rpm
79
80
Sound pressure level dB(A)
Sound pressure level dB(A)

2100 rpm 77

75 2100 rpm

75
73
1200 rpm

71

70
69 1200 rpm

67

65 65
50 100 150 200 250 300 0 50 100 150 200 250 300

Pump outlet pressure (bar) Pump outlet pressure (bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
24 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

P1 Series Typical Noise Characteristics


(These are anechoic sound pressure readings)

P1 060 Mobile Pump Typical Sound Level P1 075/085 Mobile Pump Typical Sound Level
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
90 90
2400 rpm 2300 rpm

1800 rpm 1800 rpm


85
1500 rpm 1500 rpm
85

Sound pressure level dB(A)


Sound pressure level dB(A)

1200 rpm 1200 rpm

80

80

75

75
70

solid lines are for maximum displacement and dashed lines are for zero flow solid lines are for maximum displacement and dashed lines are for zero flow
70 65
50 100 150 200 250 300 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)

P1 100 Mobile Pump Typical Sound Level P1 140 Mobile Pump Typical Sound Level
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
90 90
2100 rpm
solid lines are for maximum displacement and dashed lines are for zero flow 2000 rpm
1800 rpm
1800 rpm
85 1500 rpm 85
1500 rpm
Sound pressure level dB(A)
Sound pressure level dB(A)

1200 rpm
1200 rpm
1000 rpm
80 80 1000 rpm

75 75

70 70

solid lines are for maximum displacement and dashed lines are for zero flow

65 65
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 25
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

PD Series Typical Noise Characteristics


(These are anechoic sound pressure readings)

PD 018 Sound Levels (Zero Flow) PD 018 Sound Levels (Full Flow)
ISO VG32 fluid - 50C inlet oil temperature ISO VG32 fluid - 50C inlet oil temperature
80 80

1800 rpm 1800 rpm

75 75
1500 rpm 1500 rpm

Sound pressure level dB(A)


Sound pressure level dB(A)

70 70

65 1200 rpm 65 1200 rpm

1000 rpm 1000 rpm

60 60

55 55

50 50
0 50 100 150 200 250 300 0 50 100 150 200 250 300

Pump outlet pressure (bar) Pump outlet pressure (bar)

PD 028 Sound Levels (Zero Flow) PD 028 Sound Levels (Full Flow)
ISO VG32 fluid - 50C inlet oil temperature ISO VG32 fluid - 50C inlet oil temperature
80 80

1800 rpm 1800 rpm

75 1500 rpm 75 1500 rpm


Sound pressure level dB(A)
Sound pressure level dB(A)

70 70

65 65

1200 rpm 1200 rpm

60 60 1000 rpm
1000 rpm

55 55

solid lines are for maximum displacement and dashed lines are for zero flow
50 50
0 50 lines are for maximum
100 150 and dashed200 250 300 0 50 100 150 200 250 300
solid displacement lines are for zero flow
Pump outlet pressure (bar) Pump outlet pressure (bar)

PD 045 Sound Levels (Zero Flow) PD 045 Sound Levels (Full Flow)
ISO VG32 fluid - 50C inlet oil temperature ISO VG32 fluid - 50C inlet oil temperature
74 78

76
72
1800 rpm
74
Sound pressure level dB(A)
Sound pressure level dB(A)

70 1500 rpm
72
1200 rpm
68 70 1800 rpm

66 68 1500 rpm

66 1200 rpm
64
64

62
62

60 60
50 100 150 200 250 300 0 50 100 150 200 250 300
Pump output pressure (bar) Pump outlet pressure (bar)
solid lines are for maximum displacement and dashed lines are for zero flow
solid lines are for maximum displacement and dashed lines are for zero flow

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
26 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Performance Data P1/PD Series

PD Series Typical Noise Characteristics


(These are anechoic sound pressure readings)

PD 060 Industrial Pump Typical Sound Level PD 075/085 Industrial Pump Typical Sound Level
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
85 85

1800 rpm 1800 rpm

80 80 1500 rpm
1500 rpm

Sound pressure level dB(A)


Sound pressure level dB(A)

1200 rpm 1200 rpm

75 75

70 70

solid lines are for maximum displacement and dashed lines are for zero flow solid lines are for maximum displacement and dashed lines are for zero flow
65 65

60 60
0 50 100 150 200 250 300 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)

PD 100 Industrial Pump Typical Sound Level PD 140 Industrial Pump Typical Sound Level
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
85 85
1800 rpm
solid lines are for maximum displacement and dashed lines are for zero flow 1800 rpm
1500 rpm
1500 rpm
80
Sound pressure level dB(A)

80 1200 rpm
Sound pressure level dB(A)

1200 rpm

75

75

70

70
65

solid lines are for maximum displacement and dashed lines are for zero flow

60 65
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 27
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Notes P1/PD Series

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
28 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-018


Input Shaft Dimensions

P1/PD-018 Mounting Flange & Shaft Dimensions

Dimension ISO Key (Code 04) SAE (Code 01 or 02) SAE (Code 06)

AA 20.01/19.99 19.05/19.02 N/A

AB 22.5 21.25/20.95 N/A

AC 36.0 32.8/31.2 N/A

AD ISO E20N SAE J744 19-1 N/A

BA N/A 12.0 12.5

BB N/A 30.0 24.0

BC N/A 38.2 32.2

SPLINE: ANSI 92.1-1996 SPLINE: ANSI 92.1-1996


SAE 19-4 INVOLUTE SPLINE SAE 16-4 (A) INVOLUTE SPLINE
CLASS 7 FLAT ROOT SIDE FIT CLASS 7 FLAT ROOT SIDE FIT
NUMBER OF TEETH - 11 NUMBER OF TEETH - 9
BD N/A
PITCH - 16/32 PITCH - 16/32
PRESSURE ANGLE - 30° PRESSURE ANGLE - 30°
MAJOR DIAMETER - 19.05/18.49 MAJOR DIAMETER - 15.88/15.32
PITCH DIAMETER - 17.463 PITCH DIAMETER - 12.288

CA ISO 3019-2: 80A2SW SAE J744: JUN 96 82-2 (A) SAE J744: JUN 96 82-2 (A)

CB 11.1 11.1 11.1

CC 54.5 53.2 53.2

CD 109.0 106.4 106.4

CE 80.00/79.95 82.55/82.50 82.55/82.50

CF 7.0 6.35 6.35

Key Width 6.05/6.00 4.81/4.76 N/A

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 29
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-018


End Port
“L” or “AM” Control Option

P1/PD-018 Port Sizes


Ports SAE Threaded Metric Threaded BSPP
"A" Inlet SAE-16 M33x2 -
"B" Outlet SAE-12 M27x2 -
BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-6 M16x1.5 3/8"

Note A: SAE o-ring port conforms to SAE J514


Note B: Metric o-ring boss port conforms to ISO 6149-1
Note C: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
30 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-018


Side Port
“L” or “AM” Control Option

"B" Outlet Port

P1/PD-018 Port Sizes


Ports SAE Threaded Metric Threaded BSPP
"A" Inlet SAE-16 M33x2 -
"B" Outlet SAE-12 M27x2 -
BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-6 M16x1.5 3/8"

Note A: SAE o-ring port conforms to SAE J514


Note B: Metric o-ring boss port conforms to ISO 6149-1
Note C: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 31
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-018 P1/PD-018 Port Sizes


Side Ports with Thru-Drive Ports SAE Flanged SAE Threaded Metric Flanged Metric Threaded BSPP

“L” or “AM” Control Option "A" Inlet 1" Code 61 SAE-16 DN25 M33x2 -

W Threads 3/8-16 UNC-2B - M10x1.5-6H - -


"B" Outlet 3/4" Code 61 SAE-12 DN20 M27x2 -
Y Threads 3/8-16 UNC-2B - M10x1.5-6H - -
BG, X SAE-4 M12x1.5 1/4"
D1, D2, D3 SAE-6 M16x1.5 3/8"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE J514
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Thru-Drive Mounting Options

SAE-A Mounting Options Information


Model Number T0*A
Spline: ANSI B92.1 1996
SAE 16-4 (A) Involute Spline
Class 7 Flat Root Side Fit
Number of Teeth - 9
Pitch - 16/32
Pressure Angle - 30°
Major Diameter - 13.06/12.93 mm
Pitch Diameter - 14.29 mm
Model Number T0*H
Spline: ANSI B92.1 1996
SAE 19-4 Involute Spline
Class 7 Flat Root Side Fit
Number of Teeth - 11
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 16.14/16.02 mm
Pitch Diameter - 17.46 mm

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
32 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-028


Input Shaft Dimensions

P1/PD-028 Mounting Flange & Shaft Dimensions


Dimension ISO (Code 04) SAE (Code 01 or 02) SAE (Code 08)
AA 25.00/24.95 25.40/25.35 N/A
AB 28.20/27.80 28.38/28.12 N/A
AC 48.8/47.2 46.8/45.2 N/A
AD ISO E25N SAE J744 25-1 (B-B) N/A

BA N/A 20.0 15.0

BB N/A 38.0 33.0


BC N/A 46.8/45.2 41.8/40.2
SPLINE: ANSI B92.1-1996 SPLINE: ANSI B92.1-1996
SAE 25-4 (B-B) INVOLUTE SPLINE SAE 22-4 (B) INVOLUTE SPLINE
CLASS 7 FLAT ROOT SIDE FIT CLASS 7 FLAT ROOT SIDE FIT
NUMBER OF TEETH - 15 NUMBER OF TEETH - 13
BD N/A
PITCH - 16/32 PITCH - 16/32
PRESSURE ANGLE - 30° PRESSURE ANGLE - 30°
MAJOR DIAMETER - 25.40/24.84 MAJOR DIAMETER - 22.23/21.67
PITCH DIAMETER - 23.813 PITCH DIAMETER - 20.638
CA ISO 3019-2: 100B2SW SAE J744: JUN96 101-2 (B) SAE J744: JUN96 101-2 (B)

CB 13.7/13.3 14.6/14.2 14.6/14.2

CC 70.0 73.0 73.0

CD 140.0 146.0 146.0

CE 100.00/99.95 101.60/101.55 101.60/101.55


CF 9.5/9.0 9.7/9.5 9.7/9.5
Key Width 8.03/7.98 6.40/6.35 N/A

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 33
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-028


End Port
“L” or “AM” Control Option

P1/PD-028 Port Sizes


SAE SAE Metric Metric
Ports BSPP
Flanged Threaded Flanged Threaded
1-1/4"
"A" Inlet SAE-20 DN32 M42x2 -
Code 61
7/16-14
W Threads - M10x1.5-6H - -
UNC-2B
3/4"
"B" Outlet SAE-12 DN19 M27x2 -
Code 61
3/8-16
Y Threads - M10x1.5-6H - -
UNC-2B
BG, X SAE-4 M12x1.5 1/4"
D1, D2, D3 SAE-8 M22x1.5 1/2"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE J514
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
34 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-028


Side Port
“L” or “AM” Control Option

P1/PD-028 Port Sizes


SAE SAE Metric Metric
Ports BSPP
Flanged Threaded Flanged Threaded
1-1/4"
"A" Inlet SAE-20 DN32 M42x2 -
Code 61
7/16-14
W Threads - M10x1.5-6H - -
UNC-2B
3/4"
"B" Outlet SAE-12 DN19 M27x2 -
Code 61
3/8-16
Y Threads - M10x1.5-6H - -
UNC-2B
BG, X SAE-4 M12x1.5 1/4"
D1, D2, D3 SAE-8 M22x1.5 1/2"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE J514
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 35
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-028 P1/PD-028 Port Sizes


Side Ports with Thru-Drive Ports SAE Flanged SAE Threaded Metric Flanged Metric Threaded BSPP

“L” or “AM” Control Option "A" Inlet 1-1/4" Code 61 SAE-20 DN32 M42x2 -
W Threads 7/16-14 UNC-2B - M10x1.5-6H - -
"B" Outlet 3/4" Code 61 SAE-12 DN19 M27x2 -
Y Threads 3/8-16 UNC-2B - M10x1.5-6H - -
BG, X SAE-4 M12x1.5 1/4"
D1, D2, D3 SAE-8 M22x1.5 1/2"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE J514
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Thru-Drive Mounting Options

SAE-A Mounting Options Information


Model Number T0*A Model Number T0*H
Spline: ANSI B92.1 1996 Spline: ANSI B92.1 1996
SAE 16-4 (A) Involute Spline SAE 19-4 Involute Spline
Class 7 Flat Root Side Fit Class 7 Flat Root Side Fit
Number of Teeth - 9 Number of Teeth - 11
Pitch - 16/32 Pitch - 16/32
Pressure Angle - 30° Pressure Angle - 30°
Major Diameter - 13.06/12.93 mm Minor Diameter - 16.14/16.02 mm
Pitch Diameter - 14.29 mm Pitch Diameter - 17.46 mm

SAE-B Mounting Options Information


Model Number T0*B Model Number T0*Q
Spline: ANSI B92.1 1996 Spline: ANSI B92.1 1996
SAE 22-4 (B) Involute Spline SAE 25-4 (B-B) Involute Spline
Class 7 Flat Root Side Fit Class 7 Flat Root Side Fit
Number of Teeth - 13 Number of Teeth - 15
Pitch - 16/32 Pitch - 16/32
Pressure Angle - 30° Pressure Angle - 30°
Minor Diameter - 19.28/19.15 mm Minor Diameter - 22.40/22.28 mm
Pitch Diameter - 20.64 mm Pitch Diameter - 23.81 mm

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
36 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-045


Input Shaft Dimensions

P1/PD-045 Mounting Flange & Shaft Dimensions


Dimension ISO (Code 04) SAE (Code 01 or 02) SAE (Code 08)
AA 25.01/24.99 25.40/25.35 N/A
AB 28.13/27.87 28.23/27.97 N/A
AC 48.8/47.2 46.8/45.2 N/A

AD ISO E25N SAE J744 25-1 (B-B) N/A

BA N/A 28.5 23.0

BB N/A 38.0 33.00


BC N/A 46.8/45.2 41.8/40.2
SPLINE: ASA B5.15-1960 SPLINE: ASA B5.15-1960
SAE 25-4 (B-B) INVOLUTE SPLINE SAE 22-4 (B) INVOLUTE SPLINE
CLASS 2 FLAT ROOT SIDE FIT CLASS 2 FLAT ROOT SIDE FIT
NUMBER OF TEETH - 15 NUMBER OF TEETH - 13
BD N/A
PITCH - 16/32 PITCH - 16/32
PRESSURE ANGLE - 30° PRESSURE ANGLE - 30°
MAJOR DIAMETER - 24.98/24.85 MAJOR DIAMETER - 21.81/21.67
PITCH DIAMETER - 23.813 PITCH DIAMETER - 20.638
CA ISO 3019-2: 100B2SW SAE J744: JUN96 101-2 (B) SAE J744: JUN96 101-2 (B)

CB 13.8/13.5 14.6/14.2 14.6/14.2

CC 70.0 73.0 73.0

CD 140.0 146.0 146.0

CE 100.00/99.95 101.60/101.55 101.60/101.55


CF 9.5/9.0 9.7/9.2 9.7/9.2
Key Width 8.01/7.96 6.40/6.35 N/A

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 37
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-045


End Port
“L” or “AM” Control Option

P1/PD-045 Port Sizes


SAE SAE Metric Metric
Ports BSPP
Flanged Threaded Flanged Threaded
1-1/2"
"A" Inlet SAE-24 DN38 M48x2 -
Code 61
1/2-13
W Threads - M12x1.75-6H - -
UNC-2B
1"
"B" Outlet SAE-16 DN25 M33x2 -
Code 61
3/8-16
Y Threads - M10x1.5-6H - -
UNC-28
BG, X SAE-4 M12x1.5 1/4"
D1, D2, D3 SAE-10 M22x1.5 1/2"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
38 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-045


Side Port
“L” or “AM” Control Option

P1/PD-045 Port Sizes


SAE SAE Metric Metric
Ports BSPP
Flanged Threaded Flanged Threaded
1-1/2"
"A" Inlet SAE-24 DN38 M48x2 -
Code 61
1/2-13
W Threads - M12x1.75-6H - -
UNC-2B
1"
"B" Outlet SAE-16 DN25 M33x2 -
Code 61
3/8-16
Y Threads - M10x1.5-6H - -
UNC-28
BG, X SAE-4 M12x1.5 1/4"
D1, D2, D3 SAE-10 M22x1.5 1/2"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 39
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-045 P1/PD-045 Port Sizes

Side Ports with Thru-Drive SAE Flanged SAE Threaded Metric Flanged Metric Threaded BSPP
"A" Inlet 1-1/2" Code 61 SAE-24 DN38 M48x2 -
“L” or “AM” Control Option W Threads 1/2-13 UNC-2B - M12x1.75-6H - -
"B" Outlet 1" Code 61 SAE-16 DN25 M33x2 -

Y Threads 3/8-16 UNC-28 - M10x1.5-6H - -

BG, X SAE-4 M12x1.5 1/4"


D1, D2, D3 SAE-10 M22x1.5 1/2"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Thru-Drive Mounting Options


SAE-A Mounting Options Information
Model Number T0*A Model Number T0*H
Spline: ANSI B92.1 1996 Spline: ANSI B92.1 1996
SAE 16-4 (A) Involute Spline SAE 19-4 Involute Spline
Class 7 Flat Root Side Fit Class 7 Flat Root Side Fit
Number of Teeth - 9 Number of Teeth - 11
Pitch - 16/32 Pitch - 16/32
Pressure Angle - 30° Pressure Angle - 30°
Major Diameter - 13.06/12.93 mm Minor Diameter - 16.14/16.02 mm
Pitch Diameter - 14.29 mm Pitch Diameter - 17.46 mm

SAE-B Mounting Options Information


Model Number T0*B Model Number T0*Q
Spline: ANSI B92.1 1996 Spline: ANSI B92.1 1996
SAE 22-4 (B) Involute Spline SAE 25-4 (B-B) Involute Spline
Class 7 Flat Root Side Fit Class 7 Flat Root Side Fit
Number of Teeth - 13 Number of Teeth - 15
Pitch - 16/32 Pitch - 16/32
Pressure Angle - 30° Pressure Angle - 30°
Minor Diameter - 19.28/19.15 mm Minor Diameter - 22.40/22.28 mm
Pitch Diameter - 20.64 mm Pitch Diameter - 23.81 mm

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
40 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-060


Input Shaft Dimensions

P1/PD-060 Mounting Flange & Shaft Dimensions


Dimension ISO (Code 04) SAE (Code 01 or 02) SAE (Code 09) SAE (Code 10)

AA 32.03/32.00 31.75/31.70 N/A N/A

AB 35.00/34.71 35.33/35.02 N/A N/A


AC 68.8/67.2 56.8/55.2 N/A N/A

AD ISO E32N SAE J744 32-1 (C) N/A N/A

BA N/A 36.0 26.0 15.5

BB N/A 48.0 38.0 33.0


BC N/A 56.0 46.0 41.2
SPLINE: ASA B5.15-1960 SPLINE: ANSI B92.1-1996 SPLINE: ANSI B92.1-1996
SAE 32-4 (C) INVOLUTE SPLINE SAE 25-4 (B-B) INVOLUTE SPLINE SAE 22-4 (B) INVOLUTE SPLINE
CLASS 2 FLAT ROOT SIDE FIT CLASS 7 FLAT ROOT SIDE FIT CLASS 7 FLAT ROOT SIDE FIT
NUMBER OF TEETH - 14 NUMBER OF TEETH - 15 NUMBER OF TEETH - 13
BD N/A
PITCH - 12/24 PITCH - 16/32 PITCH - 16/32
PRESSURE ANGLE - 30° PRESSURE ANGLE - 30° PRESSURE ANGLE - 30°
MAJOR DIAMETER - 31.22/31.09 MAJOR DIAMETER - 25.00/24.84 MAJOR DIAMETER - 22.23/21.67
PITCH DIAMETER - 29.634 PITCH DIAMETER - 23.813 PITCH DIAMETER - 20.638
CA ISO 3019-2: 125B4SW SAE J744: JUN 96 127-4 (C) SAE J744: JUN96 101-2 (B) SAE J744: JUN96 101-2 (B)

CB 13.8/13.5 14.6/14.2 14.6/14.2 14.6/14.2

CC 56.6 56.8 N/A N/A

CD 113.1 square 113.5 square N/A N/A

CE 125.00/124.94 127.00/126.95 101.60/101.55 101.60/101.55


CF 9.5/9.0 12.7/12.2 9.7/9.2 9.7/9.2
Key Width 10.01/9.96 8.00/7.95 N/A N/A

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 41
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-060


End Port
“L” or “AM” Control Option

P1/PD-060 Port Sizes


Ports SAE Flanged SAE Threaded Metric Flanged BSPP
"A" Inlet 2" Code 61 2-1/2-12 UNF-2B DN51 2"
W Threads 1/2-13 UNC-2B - M12x1.75-6H -
"B" Outlet 1" Code 61 1-5/8-12 UNF-2B DN25 1-1/4"
Y Threads 3/8-16 UNC-28 - M10x1.5-6H -

BG, X SAE-4 M12x1.5 1/4"


D1, D2, D3 SAE-10 M22x1.5 3/4"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1
*Cannot use standard SAE Code 61 split flanges with the end ported option

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
42 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-060


Side Port
“L” or “AM” Control Option

P1/PD-060 Port Sizes


Ports SAE Flanged Metric Flanged BSPP

"A" Inlet 2" Code 61 DN51 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -


"B" Outlet 1" Code 61 DN25 -
Y Threads 3/8-16 UNC-28 M10x1.5-6H -
BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-10 M22x1.5 3/4"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 43
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-060 P1/PD-060 Port Sizes

Side Ports with Thru-Drive Ports SAE Flanged Metric Flanged BSPP

“L” or “AM” Control Option "A" Inlet 2" Code 61 DN51 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -


"B" Outlet 1" Code 61 DN25 -
Y Threads 3/8-16 UNC-28 M10x1.5-6H -

BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-10 M22x1.5 3/4"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
44 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-060


Side Ports with Thru-Drive
Mounting Options

SAE-A
SAE-A Mounting Options Information
Model Number T0*A
Spline: ANSI B92.1 1996
SAE 16-4 (A) Involute Spline
Class 7 Flat Root Side Fit
Number of Teeth - 9
Pitch - 16/32
Pressure Angle - 30°
Major Diameter - 13.06/12.93 mm
Pitch Diameter - 14.29 mm
Model Number T0*H
Spline: ANSI B92.1 1996
SAE 19-4 Involute Spline
Class 7 Flat Root Side Fit
Number of Teeth - 11
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 16.14/16.02 mm
Pitch Diameter - 17.46 mm

SAE-B
SAE-B Mounting Options Information
Model Number T0*B
Spline: ANSI B92.1 1996
SAE 22-4 (B) Involute Spline
Class 7 Flat Root Side Fit
Number of Teeth - 13
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 19.28/19.15 mm
Pitch Diameter - 20.64 mm
Model Number T0*Q
Spline: ANSI B92.1 1996
SAE 25-4 (B-B) Involute Spline
Class 7 Flat Root Side Fit
Number of Teeth - 15
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 22.40/22.28 mm
Pitch Diameter - 23.81 mm

SAE-C

SAE-C Mounting Options Information


Model Number T0*C
Spline: ANSI B92.1 1996
SAE 32-4 (C) Involute Spline
Class 2 Flat Root Side Fit
Number of Teeth - 14
Pitch - 12/24
Pressure Angle - 30°
Minor Diameter - 27.74/27.61 mm
Pitch Diameter - 29.63 mm

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 45
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-075 & 085


Input Shafts

P1/PD-075 & 085 Mounting Flange & Shaft Dimensions


Dimension ISO (Code 04) SAE (Code 01 or 02)
AA 32.03/32.00 31.75/31.70
AB 35.00/34.71 35.33/35.02
AC 68.8/67.2 56.8/55.2
AD ISO E32N SAE J744 32-1 (C)
BA N/A 36.0
BB N/A 48.0
BC N/A 56.0
SPLINE: ASA B5.15-1960
SAE 32-4 (C) INVOLUTE SPLINE
CLASS 1 FLAT ROOT SIDE FIT
NUMBER OF TEETH - 14
BD N/A
PITCH - 12/24
PRESSURE ANGLE - 30°
MAJOR DIAMETER - 31.22/31.09
PITCH DIAMETER - 29.634
CA ISO 3019-2: 125B4SW SAE J744: JUN 96 127-4 (C)
CB 13.8/13.5 14.6/14.2
CC 56.6 56.8
CD 113.1 square 113.5 square
CE 125.00/124.95 127.00/126.95
CF 9.5/9.0 12.7/12.2
Key Width 10.01/9.96 8.00/7.95

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
46 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-075 & 085


End Port
“L” or “AM” Control Option

P1/PD-075 & 085 Port Sizes


Ports SAE Flanged Metric Flanged BSPP

"A" Inlet 2" Code 61 DN51 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -


"B" Outlet 1" Code 61 DN25 -
Y Threads 3/8-16 UNC-28 M10x1.5-6H -

BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-12 M27x2 3/4"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 47
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-075 & 085


Side Port
“L” or “AM” Control Option

P1/PD-075 & 085 Port Sizes


Ports SAE Flanged Metric Flanged BSPP

"A" Inlet 2" Code 61 DN51 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -


"B" Outlet 1" Code 61 DN25 -
Y Threads 3/8-16 UNC-28 M10x1.5-6H -

BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-12 M27x2 3/4"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
48 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-075 & 085 P1/PD-075 & 085 Port Sizes

Side Ports with Thru-Drive Ports SAE Flanged Metric Flanged BSPP

“L” or “AM” Control Option "A" Inlet 2" Code 61 DN51 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -


"B" Outlet 1" Code 61 DN25 -
Y Threads 3/8-16 UNC-28 M10x1.5-6H -

BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-12 M27x2 3/4"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 49
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-075 & 085


Side Ports with Thru-Drive
Mounting Options

SAE-A SAE-A Mounting Options Information


Model Number T0*A
Spline: ANSI B92.1 1996
SAE 16-4 (A) Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 9
Pitch - 16/32
Pressure Angle - 30°
Major Diameter - 13.06/12.93 mm
Pitch Diameter - 14.29 mm
Model Number T0*H
Spline: ANSI B92.1 1996
SAE 19-4 Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 11
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 16.14/16.02 mm
Pitch Diameter - 17.46 mm

SAE-B SAE-B Mounting Options Information


Model Number T0*B
Spline: ANSI B92.1 1996
SAE 22-4 (B) Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 13
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 19.28/19.15 mm
Pitch Diameter - 20.64 mm
Model Number T0*Q
Spline: ANSI B92.1 1996
SAE 25-4 (B-B) Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 15
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 22.40/22.28 mm
Pitch Diameter - 23.81 mm

SAE-C

SAE-C Mounting Options Information


Model Number T0*C
Spline: ANSI B92.1 1996
SAE 32-4 (C) Involute Spline
Class 1 Flat Root Side Fit
Number of Teeth - 14
Pitch - 12/24
Pressure Angle - 30°
Minor Diameter - 27.74/27.61 mm
Pitch Diameter - 29.63 mm

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
50 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-100


Input Shafts

P1/PD-100 Mounting Flange & Shaft Dimensions

Dimension ISO (Code 04) SAE (Code 01 or 02) SAE (Code 06)

AA 40.02/40.00 38.10/38.05 N/A

AB 43.71/43.00 42.35/42.17 N/A

AC 92.8/91.2 62.8/62.1 N/A

AD ISO E40N SAE J744 38-1 (C-C) N/A

BA N/A 42.1 36.0

BB N/A 54.0 48.0

BC N/A 62.0 56.0


SPLINE: ASA-B5.15-1960 SPLINE: ASA-B5.15-1960
SAE 38-4 (C-C) INVOLUTE SPLINE SAE 32-4 (C) INVOLUTE SPLINE
CLASS 1 FLAT ROOT SIDE FIT CLASS 1 FLAT ROOT SIDE FIT
NUMBER OF TEETH - 17 NUMBER OF TEETH - 14
BD N/A
PITCH - 12/24 PITCH - 12/24
PRESSURE ANGLE - 30 PRESSURE ANGLE - 30
MAJOR DIAMETER - 37.57/37.44 MAJOR DIAMETER - 31.22/31.09
PITCH DIAMETER - 35.984 PITCH DIAMETER - 29.634
CA ISO 3019-2: 125B4SW SAE J744: JUN 96 127-4 (C) SAE 744: JUN 96 127-4 (C)

CB 13.8/13.5 14.6/14.2 14.6/14.2

CC 56.6 56.8 56.8

CD 113.1 square 113.5 square 113.5 square

CE 125.00/124.95 127.00/126.95 127.00/126.95

CF 9.5/9.0 12.7/12.2 12.7/12.2

Key Width 12.01/11.96 9.58/9.53 8.00/7.95

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 51
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-100


End Ports
“L” or “AM” Control Option

P1/PD-100 Port Sizes


Ports SAE Flanged Metric Flanged BSPP

"A" Inlet 2-1/2" Code 61 DN63 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -


"B" Outlet 1-1/4" Code 62 DN32 -
Y Threads 1/2-13 UNC-28 M12x1.75-6H -

BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-12 M27x2 3/4"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
52 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-100


Side Ports
“L” or “AM” Control Option

P1/PD-100 Port Sizes


Ports SAE Flanged Metric Flanged BSPP

"A" Inlet 2-1/2" Code 61 DN63 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -


"B" Outlet 1-1/4" Code 62 DN32 -
Y Threads 1/2-13 UNC-28 M12x1.75-6H -

BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-12 M27x2 3/4"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 53
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-100 P1/PD-100 Port Sizes

Side Ports with Thru-Drive Ports SAE Flanged Metric Flanged BSPP

“L” or “AM” Control Option "A" Inlet 2-1/2" Code 61 DN63 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -


"B" Outlet 1-1/4" Code 62 DN32 -
Y Threads 1/2-13 UNC-28 M12x1.75-6H -

BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-12 M27x2 3/4"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
54 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-100


Side Ports with Thru-Drive
Mounting Options

SAE-A
SAE-A Mounting Options Information
Model Number T0*A
Spline: ANSI B92.1 1996
SAE 16-4 (A) Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 9
Pitch - 16/32
Pressure Angle - 30°
Major Diameter - 13.06/12.93 mm
Pitch Diameter - 14.29 mm
Model Number T0*H
Spline: ANSI B92.1 1996
SAE 19-4 Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 11
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 16.14/16.02 mm
Pitch Diameter - 17.46 mm

SAE-B
SAE-B Mounting Options Information
Model Number T0*B
Spline: ANSI B92.1 1996
SAE 22-4 (B) Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 13
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 19.28/19.15 mm
Pitch Diameter - 20.64 mm
Model Number T0*Q
Spline: ANSI B92.1 1996
SAE 25-4 (B-B) Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 15
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 22.40/22.28 mm
Pitch Diameter - 23.81 mm

SAE-C
SAE-C Mounting Options Information
Model Number T0*C
Spline: ANSI B92.1 1996
SAE 32-4 (C) Involute Spline
Class 1 Flat Root Side Fit
Number of Teeth - 14
Pitch - 12/24
Pressure Angle - 30°
Minor Diameter - 27.74/27.61 mm
Pitch Diameter - 29.63 mm
Model Number T0*N
Spline: ANSI B92.1 1996
SAE 38-4 (C-C) Involute Spline
Class 1 Flat Root Side Fit
Number of Teeth - 17
Pitch - 12/24
Pressure Angle - 30°
Minor Diameter - 34.01/33.88 mm
Pitch Diameter - 35.98 mm

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 55
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-140


Input Shafts

P1/PD-140 Mounting Flange & Shaft Dimensions

Dimension ISO (Code 04) SAE (Code 01 or 02)

ØAA 50.03/50.00 44.45/44.43

AB 53.50/53.21 49.43/49.17

AC 92.8/91.2 75.8/74.2

AD ISO E50N SAE J744 44-1 (D)

BA N/A 39.0

BB N/A 67.0

BC N/A 75.0

SPLINE: SAE J498-B 1969


SAE 44-4( D) INVOLUTE SPLINE
CLASS 1 FLAT ROOT SIDE FIT
NUMBER OF TEETH - 13
BD N/A
PITCH - 8/16
PRESSURE ANGLE - 30°
MAJOR DIAMETER - 43.71/43.59
PITCH DIAMETER - 41.275

CA ISO 3019-2: 180B4SW SAE J744: JUN 96 152-4 (D)

CB 18.2/17.8 20.9/20.5

CC 79.2 80.8

CD 158.4 161.6

CE 180.00/179.95 152.40/152.35

CF 9.5/9.0 12.7/12.2

Key Width 14.00/13.95 11.14/11.09

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
56 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-140


End Ports
“L” or “AM” Control Option

P1/PD-140 Port Sizes


Ports SAE Flanged Metric Flanged BSPP

"A" Inlet 2-1/2" Code 61 DN63 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -


"B" Outlet 1-1/4" Code 62 DN32 -
Y Threads 1/2-13 UNC-28 M12x1.75-6H -

BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-16 M33x2 1"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 57
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-140


Side Ports
“L” or “AM” Control Option

P1/PD-140 Port Sizes


Ports SAE Flanged Metric Flanged BSPP

"A" Inlet 2-1/2" Code 61 DN63 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -

"B" Outlet 1-1/4" Code 62 DN32 -

Y Threads 1/2-13 UNC-28 M12x1.75-6H -

BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-16 M33x2 1"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
58 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-140 P1/PD-140 Port Sizes

Side Ports with Thru-Drive Ports SAE Flanged Metric Flanged BSPP

“L” or “AM” Control Option "A" Inlet 2-1/2" Code 61 DN63 -

W Threads 1/2-13 UNC-2B M12x1.75-6H -

"B" Outlet 1-1/4" Code 62 DN32 -

Y Threads 1/2-13 UNC-28 M12x1.75-6H -

BG, X SAE-4 M12x1.5 1/4"

D1, D2, D3 SAE-16 M33x2 1"

Note A: SAE flanged ports conform to SAE J518


Note B: SAE o-ring port conforms to SAE 1926
Note C: Metric flanged ports conform to ISO 6162
Note D: Metric o-ring boss port conforms to ISO 6149-1
Note E: BSPP port conforms to ISO 228-1

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 59
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data P1/PD Series

Pump Installation - P1/PD-140


Side Ports with Thru-Drive
Mounting Options

SAE-A Mounting Options Information SAE-B Mounting Options Information


Model Number T0*A Model Number T0*H Model Number T0*B Model Number T0*Q
Spline: ANSI B92.1 1996 Spline: ANSI B92.1 1996 Spline: ANSI B92.1 1996 Spline: ANSI B92.1 1996
SAE 16-4 (A) Involute Spline SAE 19-4 Involute Spline SAE 22-4 (B) Involute Spline SAE 25-4 (B-B) Involute Spline
Class 5 Flat Root Side Fit Class 5 Flat Root Side Fit Class 5 Flat Root Side Fit Class 5 Flat Root Side Fit
Number of Teeth - 9 Number of Teeth - 11 Number of Teeth - 13 Number of Teeth - 15
Pitch - 16/32 Pitch - 16/32 Pitch - 16/32 Pitch - 16/32
Pressure Angle - 30° Pressure Angle - 30° Pressure Angle - 30° Pressure Angle - 30°h
Major Diameter - 13.06/12.93 mm Minor Diameter - 16.14/16.02 mm Minor Diameter - 19.28/19.15 mm Minor Diameter - 22.40/22.28 mm
Pitch Diameter - 14.29 mm Pitch Diameter - 17.46 mm Pitch Diameter - 20.64 mm Pitch Diameter - 23.81 mm

SAE-C Mounting Options Information SAE-D Mounting Options Information


Model Number T0*C Model Number T0*N Model Number T0*D
Spline: ANSI B92.1 1996 Spline: ANSI B92.1 1996 Spline: ANSI B92.1 1996
SAE 32-4 (C) Involute Spline SAE 38-4 (C-C) Involute Spline SAE 44-4 (D) Involute Spline
Class 5 Flat Root Side Fit Class 5 Flat Root Side Fit Class 1 Flat Root Side Fit
Number of Teeth - 14 Number of Teeth - 17 Number of Teeth - 13
Pitch - 12/24 Pitch - 12/24 Pitch - 8/16
Pressure Angle - 30° Pressure Angle - 30° Pressure Angle - 30°
Minor Diameter - 27.74/27.61 mm Minor Diameter - 34.01/33.88 mm Minor Diameter - 38.38/38.25 mm
Pitch Diameter - 29.63 mm Pitch Diameter - 35.98 mm Pitch Diameter - 41.28 mm

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
60 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data - Controls P1/PD Series

C0 Control
For C0 control dimensions see frame size dimensional section because the C0
control uses the same control housing as L & AM controls.

Pressure compensator adjustment

P*075 shown

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 61
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data - Controls P1/PD Series

L0T & AMT Control

L0T & AMT (45cc) L0T & AMT (60-140cc)


The L0T & AMT controls on the 45cc use the
same adapter block that is used on the
AN & ANT controls.

CW torque limiter port

CCW torque limiter port

P*045 CCW shown P*100 CW shown

L0T & AMT Control Dimensions (mm)


Model L M N T
P*045 ** 65 21 15
P*060 ** 70 25 20
P*075/085 64 72 ** 15
P*100 95 103 ** 16
P*140 117 128 ** 16

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
62 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data - Controls P1/PD Series

AN & ANT Control


The AN & ANT controls use the AM compensator with the addition of an adapter block and tubing.

AN Control (All sizes) ANT Control (45-140cc only)

P*060 shown

AN & ANT Control Dimensions (mm)


Model G J K N P
P*018 18 65 117 ** 77
P*028 37 71 135 ** 83
P*045 47 78 146 21 90

P*060 60 82 159 25 94
P*075/085 70 85 169 28 97
P*100 117 101 216 58 113
P*140 129 113 228 51 125

P*075 shown
Parker Hannifin Corporation
Hydraulic Pump and Power Systems Division
United States 63
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data - Controls P1/PD Series

AE/AF Control C0*, L0* Unload Control


The AE/AF control uses the AM compensator
with same adapter block that used on the
AN & ANT controls

P*075 shown

AE/AF Control Dimensions by Frame Size (mm)


Model D E F Unload (*03 & *06) Control Dimensions by Frame Size (mm)
P*018 207 188 65 Model A B C D E J
P*028 225 206 71 P*028 134 109 77 25 12 142
P*045 236 217 78 P*045 145 120 88 35 15 149
P*060 248 229 82 P*060 157 132 100 48 27 153
P*075/085 271 252 85 P*075/085 167 142 110 71 50 156
P*100 305 286 101 P*100 214 189 157 105 86 172
P*140 317 298 113 P*140 226 201 169 117 94 184

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
64 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data - Controls P1/PD Series

AG/AH Control

CCW ORIENTATION
P*075 shown

CW ORIENTATION
P*075 shown

AG/AH Control Dimensions by Frame Size (mm)


Model A B F G J
P*018 116 71 79 111 142
P*028 134 89 85 116 148
P*045 145 100 92 124 155
P*060 157 112 96 128 160
P*075/085 168 123 99 131 162
P*100 214 169 115 147 179
P*140 226 181 127 159 190

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 65
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data - Controls P1/PD Series

P, T, S, U Electronic Control Options

Optional Pressure Compensator

Cam Sensor

Pressure Compensator
Adjusting Screw

CW ORIENTATION CCW ORIENTATION


P*075 shown P*075 shown

External Servo Block


for Overcenter Option "X" CCW ORIENTATION
P*075 shown

RDEC Control Dimensions by Frame Size (mm)


Model A B C D L P S
P*018 203 85 116 49 ** 85 **
P*028 209 89 135 56 ** 91 **
P*045 216 96 145 60 91 123 116

P*060 220 105 158 64 95 127 133


P*075/085 223 108 168 68 98 130 138
P*100 239 121 215 101 114 146 185
P*140 251 130 227 96 126 158 196

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
66 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Installation Information P1/PD Series

Mounting These pumps are designed to operate with the shaft horizontal or pointing downward.
For shaft up mounting consult factory. The pump shaft must be in alignment with the shaft
of the source driver and should be checked with a dial indicator. The mating pilot bore and
coupling must be concentric. This concentricity is particularly important if the shaft is rigidly
connected to the driven load without a flexible coupling.

Shaft Information Splined: The shafts will accept a maximum misalignment of 0.15mm, 0.005 inch, total
indicator reading. Angular misalignment at the external and internal spline axis must be
less than ± 0,002 mm per mm of shaft radius, ± 0.002 inches per inch of shaft radius.
The coupling interface must be lubricated. PARKER recommends lithium molydisulfide or
similar grease. The internal coupling should be hardened to Rc 27-34 and must conform to
SAE-J498c, class 5 flat root side fit.
Keyed: High strength heat treated keys must be used. Replacement keys must be hardened
to 27-34 Rc. The key corners must be chamfered 0.81-1.0 mm, 0.032”-0.040”, at 45° to
clear radii that exist in the keyway.

Side Load Capacity The P1/PD series is designed for inline-drive. Side loading on the shaft is not recommended.
If this is unavoidable consult your nearest PARKER representative.

Fluid Connections Connect inlet and outlet lines to the port block of the pump. The maximum case pressure is
2 bar (30 psi) continuous, 4 bar (60 psi) intermittent. The case pressure must never exceed
inlet pressure by more than .5 bar (7 psi). When connecting case drain line make certain that
drain plumbing passes above highest point of the pump before passing to the reservoir. The
case leakage line must be of sufficient size to prevent back pressure in excess of 2 bar(30
psi) and returned to the reservoir below the surface of the oil as far from the supply inlet as
possible. All fluid lines, whether pipe, tubing, or hose must be adequate size and strength
to assure free flow through the pump. An undersize inlet line will prevent the pump from
operating properly at full rated speed. An undersize outlet line will cause back pressure and
cause heat generation and increased noise. Flexible hose lines are recommended. If rigid
piping is used, the workmanship must be accurate to eliminate strain on the pump port block
or to the fluid connections. Sharp bends in the lines must be eliminated wherever possible.
All system piping must be cleaned and flushed before installing pump. Make sure the entire
hydraulic system is free of dirt, lint, scale, or other foreign material.
CAUTION: Do not use galvanized pipe. Galvanized coating can flake off with continued use.

System Relief Valves Although the P1/PD series pumps have very fast off-stroke compensator response, system
relief valves are recommended in all cases for safety considerations.

Recommended Fluids The fluid recommended for use in these pumps has a petroleum base and contains agents
which provide oxidation inhibition and anti-rust, anti-foam and de-aerating properties as
described in PARKER standard HF-1. Where anti-wear additive fluids are specified, see
PARKER standard HF-0.

Viscosity Index 90 V. I. minimum. Higher values extend the range of operating temperature but may reduce
the service life of the fluid.

Temperature Determined by the viscosity characteristics of the fluid used. Because high temperatures
degrade seals, reduce the service life of the fluid and create hazards, fluid temperature
should not exceed 110°C (230°F) at the case drain.

Maintenance The pump is self-lubricating and preventative maintenance is limited to keeping system
fluid clean by changing filters frequently. Keep all fittings and screws tight. Do not operate
at pressures and speeds in excess of the recommended limit. If the pump does not operate
properly, check the troubleshooting chart before attempting to overhaul the unit. Overhauling
may be accomplished by referring to the disassembly, rework limits of wear parts, and
assembly procedures as provided in this service manual.

Fluid Cleanliness Fluid must be cleaned before and continuously during operation, by filters that maintain a
cleanliness level of ISO 20/18/14. Better cleanliness levels will significantly extend the life
of the components. As contaminant generation may vary with each application, each must
be analyzed to determine proper filtration to maintain the required cleanliness level.

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 67
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Conversions & Formulas P1/PD Series

CONVERSION FACTORS
DEFINITION & UNIT
Displacement in3/rev x 16.387 = cm3/rev cm3/rev x 0.06102 = in3/rev
Flow gpm x 3.78 = L/min L/min x 0.2642 = gpm
Power hp x 0.7457 = kW kW x 1.341 = hp
Torque lb-ft x 1.3567 = Nm Nm x 0.7376 = lb-ft
Pressure lbs/in2 (psi) x 0.06895 = bar bar x 14.50 = lbs/in2 (psi)
lbs/in2 (psi) x 6.895 = kPa kPa x 0.1450 = lbs/in2 (psi)
Weight lb x 0.4536 = kg kg x 2.205 = lbs
Force lb x 4.448 = N N x 0.2248 = lbs
Volume in3 x 16.387 = cm3 cm3 x 0.06102 = in3
Area in2 x 6.452 = cm2 cm2 x 0.1550 = in2
Length in x 25.4 = mm mm x 0.03937 = in
Temperature
degree F-32 = °C 1.8 x C+32 = °F
1.8
Viscosity cSt x 1.0 = mm2/sec mm2/sec x 1.0 = cSt
SSU = cSt x 4.25 + 14 20 cSt = 99 SSU

FLUID POWER FORMULAS


Pump output flow U.S. gpm rpm x displacement (in³/rev) x volumetric eff.
231
Pump input torque ft lbs pressure (psi) x displacement (in³/rev)
24� x mech. eff.
Pump input power hp rpm x torque (ft-lbs) x 2� = flow (GPM) x pressure (psi)
33000 1714 x overall eff.
Fluid motor speed rpm 231 x flow rate(U.S. gpm) x volumetric eff.
displacement (in3/rev)
Fluid motor torque ft lbs pressure (psi) x displacement (in³/rev) x mech. eff.
24�
Fluid motor power hp rpm x torque (ft-lbs) x 2� = flow (GPM) x pressure (psi) x overall eff.
33000 1714
(Metric)
Pump output flow Lpm rpm x displacement (cm³/rev) x volumetric eff.
1000
Pump input torque Nm pressure(bar) x displacement (cm³/rev)
20� x mech. eff.
Pump input power kW rpm x torque (Nm) x 2� = flow (Lpm) x pressure (bar)
60000 600 x overall eff.
Fluid motor speed rpm 1000 x flow rate (Lpm) x volumetric eff.
displacement (cm3/rev)
Fluid motor torque Nm pressure(bar) x displacement (cm³/rev) x mech. eff.
20�
Fluid motor power kW rpm x torque (Nm) x 2� = flow (Lpm) x pressure (bar) x overall eff.
60000 600

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
68 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
P1/PD Series

Extensive Hydraulic Product Offering


Accumulators Compact Hydraulics Cylinders Electronics/Remote
Controls

Piston, bladder and Self-contained with a motor, Standard and custom Parker’s unique IQAN approach
diaphragm type accumulators, gear pump, reservoir, internal hydraulic cylinders for combines sturdy, well-tested
gas bottles and KleenVent valving, load hold checks and industrial and mobile hardware with intelligent, flexible
reservoir isolators. relief valves. applications. computing power.
www.parker.com/accumulator www.parker.com/oildyne www.parker.com/cylinder www.parker.com/iqan

Filtration Integrated Hydraulic Motors Power Take Off


Circuits

Pressure and return line Solutions for complex circuits Full line of high and low Parker Chelsea leads the
filters enhances machine that include threaded cartridge speed motors provides industry for engineering,
life, reduces maintenance valves integrated into a single power up to 15,000 in-lbs innovation and performance
and lowers costs. manifold. of torque. in auxiliary power systems.
www.parker.com/hydraulicfilter www.parker.com/hcs www.parker.com/hps www.parker.com/chelsea

Power Units Pumps Rotary Actuator Valves and Controls

The most complete line of Broad line of energy-efficient Industry leader in the Hydraulic valves for virtually
standard, pre-engineered, hydraulic pumps that includes design and manufacture every hydraulic equipment
cataloged hydraulic power piston, vane and gear pumps. of hydraulic rack and pinion, application, from simple to
units in the industry. and vane style rotary actuators. precise control.
www.parker.com/hps www.parker.com/hps www.parker.com/cylinder www.parker.com/hydraulicvalve

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 69
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Offer of Sale P1/PD Series

The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, Hydraulics Group, and its authorized distributors (“Seller”) are
hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions.
Buyer’s order for any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All goods or work described will be
referred to as “Products”.

1. Terms and Conditions. Seller’s willingness to offer Products, or accept an order for 11. Buyer’s Obligation; Rights of Seller. To secure payment of all sums due or otherwise,
Products, to or from Buyer is expressly conditioned on Buyer’s assent to these Terms and Seller shall retain a security interest in the goods delivered and this agreement shall be
Conditions and to the terms and conditions found on-line at www.parker.com/saleterms/. deemed a Security Agreement under the Uniform Commercial Code. Buyer authorizes
Seller objects to any contrary or additional term or condition of Buyer’s order or any other Seller as its attorney to execute and file on Buyer’s behalf all documents Seller deems
document issued by Buyer. necessary to perfect its security interest. Seller shall have a security interest in, and lien
2. Price Adjustments; Payments. Prices stated on the reverse side or preceding pages upon, any property of Buyer in Seller’s possession as security for the payment of any
of this document are valid for 30 days. After 30 days, Seller may change prices to reflect amounts owed to Seller by Buyer.
any increase in its costs resulting from state, federal or local legislation, price increases 12. Improper Use and Indemnity. Buyer shall indemnify, defend, and hold Seller harmless
from its suppliers, or any change in the rate, charge, or classification of any carrier. The from any claim, liability, damages, lawsuits, and costs (including attorney fees), whether for
prices stated on the reverse or preceding pages of this document do not include any sales, personal injury, property damage, patent, trademark or copyright infringement or any other
use, or other taxes unless so stated specifically. Unless otherwise specified by Seller, all claim, brought by or incurred by Buyer, Buyer’s employees, or any other person, arising out
prices are F.O.B. Seller’s facility, and payment is due 30 days from the date of invoice. After of: (a) improper selection, improper application or other misuse of Products purchased by
30 days, Buyer shall pay interest on any unpaid invoices at the rate of 1.5% per month or Buyer from Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Seller’s use
the maximum allowable rate under applicable law. of patterns, plans, drawings, or specifications furnished by Buyer to manufacture Product;
3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate and or (d) Buyer’s failure to comply with these terms and conditions. Seller shall not indemnify
Seller shall not be responsible for any damages resulting from any delay. Regardless of the Buyer under any circumstance except as otherwise provided.
manner of shipment, title to any products and risk of loss or damage shall pass to Buyer 13. Cancellations and Changes. Orders shall not be subject to cancellation or change
upon tender to the carrier at Seller’s facility (i.e., when it’s on the truck, it’s yours). Unless by Buyer for any reason, except with Seller’s written consent and upon terms that will
otherwise stated, Seller may exercise its judgment in choosing the carrier and means indemnify, defend and hold Seller harmless against all direct, incidental and consequential
of delivery. No deferment of shipment at Buyers’ request beyond the respective dates loss or damage. Seller may change product features, specifications, designs and avail-
indicated will be made except on terms that will indemnify, defend and hold Seller harmless ability with notice to Buyer.
against all loss and additional expense. Buyer shall be responsible for any additional ship- 14. Limitation on Assignment. Buyer may not assign its rights or obligations under this
ping charges incurred by Seller due to Buyer’s changes in shipping, product specifications agreement without the prior written consent of Seller.
or in accordance with Section 13, herein. 15. Entire Agreement. This agreement contains the entire agreement between the Buyer
4. Warranty. Seller warrants that the Products sold hereunder shall be free from defects and Seller and constitutes the final, complete and exclusive expression of the terms of the
in material or workmanship for a period of eighteen months from the date of delivery to agreement. All prior or contemporaneous written or oral agreements or negotiations with
Buyer. The prices charged for Seller’s products are based upon the exclusive limited respect to the subject matter are herein merged.
warranty stated above, and upon the following disclaimer: DISCLAIMER OF WARRANTY: 16. Waiver and Severability. Failure to enforce any provision of this agreement will not
THIS WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TO waive that provision nor will any such failure prejudice Seller’s right to enforce that provision
PRODUCTS PROVIDED HEREUNDER. SELLER DISCLAIMS ALL OTHER WARRAN- in the future. Invalidation of any provision of this agreement by legislation or other rule of
TIES, EXPRESS AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A law shall not invalidate any other provision herein. The remaining provisions of this agree-
PARTICULAR PURPOSE. ment will remain in full force and effect.
5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon 17. Termination. This agreement may be terminated by Seller for any reason and at
delivery. No claims for shortages will be allowed unless reported to the Seller within 10 any time by giving Buyer thirty (30) days written notice of termination. In addition, Seller
days of delivery. No other claims against Seller will be allowed unless asserted in writing may by written notice immediately terminate this agreement for the following: (a) Buyer
within 60 days after delivery or, in the case of an alleged breach of warranty, within 30 commits a breach of any provision of this agreement (b) the appointment of a trustee,
days after the date within the warranty period on which the defect is or should have been receiver or custodian for all or any part of Buyer’s property (c) the filing of a petition for relief
discovered by Buyer. Any action based upon breach of this agreement or upon any other in bankruptcy of the other Party on its own behalf, or by a third party (d) an assignment for
claim arising out of this sale (other than an action by Seller for any amount due to Seller the benefit of creditors, or (e) the dissolution or liquidation of the Buyer.
from Buyer) must be commenced within thirteen months from the date of tender of delivery 18. Governing Law. This agreement and the sale and delivery of all Products hereunder
by Seller or, for a cause of action based upon an alleged breach of warranty, within thirteen shall be deemed to have taken place in and shall be governed and construed in accor-
months from the date within the warranty period on which the defect is or should have dance with the laws of the State of Ohio, as applicable to contracts executed and wholly
been discovered by Buyer. performed therein and without regard to conflicts of laws principles. Buyer irrevocably
6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS OPTION, agrees and consents to the exclusive jurisdiction and venue of the courts of Cuyahoga
REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE PURCHASE PRICE. County, Ohio with respect to any dispute, controversy or claim arising out of or relating
IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL, INDIRECT, to this agreement. Disputes between the parties shall not be settled by arbitration unless,
INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS THE RESULT after a dispute has arisen, both parties expressly agree in writing to arbitrate the dispute.
OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS OF USE OF THE 19. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no
PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR EXPENSES OF ANY liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets
NATURE INCURRED WITHOUT SELLER’S WRITTEN CONSENT, EVEN IF SELLER HAS or similar rights except as provided in this Section. Seller will defend and indemnify Buyer
BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR OTHER LEGAL THEORY. IN against allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade
NO EVENT SHALL SELLER’S LIABILITY UNDER ANY CLAIM MADE BY BUYER EXCEED dress and trade secrets (“Intellectual Property Rights”). Seller will defend at its expense
THE PURCHASE PRICE OF THE PRODUCTS. and will pay the cost of any settlement or damages awarded in an action brought against
7. Contingencies. Seller shall not be liable for any default or delay in performance if Buyer based on an allegation that a Product sold pursuant to this Agreement infringes
caused by circumstances beyond the reasonable control of Seller. the Intellectual Property Rights of a third party. Seller’s obligation to defend and indemnify
8. User Responsibility. The user, through its own analysis and testing, is solely responsible Buyer is contingent on Buyer notifying Seller within ten (10) days after Buyer becomes
for making the final selection of the system and Product and assuring that all performance, aware of such allegations of infringement, and Seller having sole control over the defense
endurance, maintenance, safety and warning requirements of the application are met. The of any allegations or actions including all negotiations for settlement or compromise. If a
user must analyze all aspects of the application and follow applicable industry standards Product is subject to a claim that it infringes the Intellectual Property Rights of a third party,
and Product information. If Seller provides Product or system options, the user is respon- Seller may, at its sole expense and option, procure for Buyer the right to continue using the
sible for determining that such data and specifications are suitable and sufficient for all Product, replace or modify the Product so as to make it noninfringing, or offer to accept
applications and reasonably foreseeable uses of the Products or systems. return of the Product and return the purchase price less a reasonable allowance for depre-
9. Loss to Buyer’s Property. Any designs, tools, patterns, materials, drawings, confi- ciation. Notwithstanding the foregoing, Seller shall have no liability for claims of infringe-
dential information or equipment furnished by Buyer or any other items which become ment based on information provided by Buyer, or directed to Products delivered hereunder
Buyer’s property, may be considered obsolete and may be destroyed by Seller after two for which the designs are specified in whole or part by Buyer, or infringements resulting
consecutive years have elapsed without Buyer placing an order for the items which are from the modification, combination or use in a system of any Product sold hereunder. The
manufactured using such property. Seller shall not be responsible for any loss or damage foregoing provisions of this Section shall constitute Seller’s sole and exclusive liability and
to such property while it is in Seller’s possession or control. Buyer’s sole and exclusive remedy for infringement of Intellectual Property Rights.
10. Special Tooling. A tooling charge may be imposed for any special tooling, including 20. Taxes. Unless otherwise indicated, all prices and charges are exclusive of excise,
without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. sales, use, property, occupational or like taxes which may be imposed by any taxing
Such special tooling shall be and remain Seller’s property notwithstanding payment of any authority upon the manufacture, sale or delivery of Products.
charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging to 21. Equal Opportunity Clause. For the performance of government contracts and where
Seller which is utilized in the manufacture of the Products, even if such apparatus has been dollar value of the Products exceed $10,000, the equal employment opportunity clauses
specially converted or adapted for such manufacture and notwithstanding any charges in Executive Order 11246, VEVRAA, and 41 C.F.R. §§ 60-1.4(a), 60-741.5(a), and 60-250.4,
paid by Buyer. Unless otherwise agreed, Seller shall have the right to alter, discard or are hereby incorporated.
otherwise dispose of any special tooling or other property in its sole discretion at any time.

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
70 United States
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Content Index P1/PD Series

April 2021 Revised shaft torques


Revised AMT & L0T
Revised formulas page

September 2020 Changed remaining A-mod controls to B-mod


Added conversion & formulas page
Corrected minor miscellaneous errors

March 2020 Corrected AN, AE/AF, & 45 & 60 L0T/AMT control images
Corrected minor miscellaneous errors

November 2019 Added B-mod information


Consolidated model code pages
Added P1/PD-085
Updated controls information to B-mod
Added AG/AH controls
Added unload controls
Added valve specs on electrical controls
Added housing & shaft options on 060
Remove 4-bolt SAE-B thru mount option
Removed 24V "M" electronic control option
Revised performance data section
Updated dimensional section with B-mod dimensions
Updated controls dimensional section

August 1, 2014 Add 1A valve to standard options


Miscellaneous minor updates

January 30, 2014 P1045 - All drawings updated

April 1, 2013 Addition of P1/PD018 thru drive


Miscellaneous drawings updates
Shaft torque rating consolidation
Electrical connector information

July 1, 2012 Addition of electronic controls

March 1, 2012 New ordering code format

WARNING
The products described in this catalog can expose you to chemicals, including Lead, which is known to the State of California to cause cancer and birth defects or other
reproductive harm. For more information go to www.p65warnings.ca.gov.

Parker Hannifin Corporation


Hydraulic Pump and Power Systems Division
United States 71
© 2021 Parker Hannifin Corporation, all rights reserved Catalog HY28-2665-01/P1/EN
Effective: April 2021
Parker Hannifin Corporation
Hydraulic Pump and Power Systems Division
14249 Industrial Pkwy
Marysville, OH 43040 USA
phone 937 644 4435
fax 937 642 3639
www.parker.com

You might also like