P1PD Medium Pressure Axial Piston Pumps-HY28-2665-01 - P1 - EN
P1PD Medium Pressure Axial Piston Pumps-HY28-2665-01 - P1 - EN
P1PD Medium Pressure Axial Piston Pumps-HY28-2665-01 - P1 - EN
Contents
General Information & Technical Specs................................................................................................................... 3
Ordering Information................................................................................................................................................ 4
Shaft Technical Data................................................................................................................................................. 6
Design Series Change Information........................................................................................................................... 7
Control Options........................................................................................................................................................ 8
Performance Data
Typical Pump Outlet Flow................................................................................................................................ 17
Typical Shaft Input Power................................................................................................................................ 19
Typical Shaft Bearing Life................................................................................................................................ 22
Typical Noise Characteristics.......................................................................................................................... 24
Dimensional Data
P1/PD 018....................................................................................................................................................... 29
P1/PD 028....................................................................................................................................................... 33
P1/PD 045....................................................................................................................................................... 37
P1/PD 060....................................................................................................................................................... 41
P1/PD 075 & 085............................................................................................................................................. 46
P1/PD 100....................................................................................................................................................... 51
P1/PD 140....................................................................................................................................................... 56
Controls........................................................................................................................................................... 61
Installation Information........................................................................................................................................... 67
Conversions & Formulas........................................................................................................................................ 68
Offer of Sale........................................................................................................................................................... 70
Content Index......................................................................................................................................................... 71
The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,
maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is
responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.
OFFER OF SALE
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributor. This offer and its acceptance
are governed by the provisions stated in the detailed "Offer of Sale" elsewhere in this document.
Technical Data
Model P1/PD 018 P1/PD 028 P1/PD 045 P1/PD 060 P1/PD 075 P1/PD 085 P1/PD 100 P1/PD 140
Maximum Displacement, cm3/rev 18 28 45 60 75 85 100 140
cu.in./rev 1.10 1.71 2.75 3.66 4.58 5.19 6.01 8.54
280 bar 250 bar 280 bar
Outlet Pressure – Continuous
(4060 psi) (3600 psi) (4060 psi)
320 bar 300 bar 320 bar
Intermittent*
(4640 psi) (4350 psi) (4640 psi)
350 bar 320 bar 350 bar
Peak
(5075 psi) (4600 psi) (5075 psi)
P1 Maximum Speed (1.3 bar abs inlet), rpm 3500 3400 3100 2800 2700 2700 2500 2400
P1 (1.0 bar abs inlet), rpm 3300 3200 2800 2500 2400 2400 2250 2100
P1 (0.8 bar abs inlet), rpm 2900 2900 2400 2200 2100 2100 1900 1800
PD Maximum Speed (1.0 bar abs inlet), rpm 1800
PD (0.8 bar abs inlet), rpm 1800
Minimum Speed, rpm 600
Inlet Pressure – Maximum 11 bar absolute (160 psi)
Rated 1.0 bar absolute (14.5 psi)
Minimum 0.8 bar absolute (11.6 psi)
Case Pressure – Peak, bar 4.0 bar absolute (58 psi) and less than 0.5 bar (7.3 psi) above inlet pressure
Rated, bar 2.0 bar absolute (29 psi) and less than 0.5 bar (7.3 psi) above inlet pressure
Fluid Temperature Range, °C -40 to +95
°F -40 to +203
Fluid Viscosity – Rated, cSt 7 to 160
Optimum Range, cSt 14-50 cSt.
Max. Intermittent, cSt 5000 (for cold starting)
Min. Intermittent, cSt 5
Fluid Contamination – Rated, ISO 20/18/14
Weight – End Port, kg (lb) 13.4 (29.5) 17.7 (39.0) 23 (50) 29 (64) 30 (66) 30 (66) 51 (112) 66 (145)
Side Port, kg (lb) 14.2 (31.3) 18.1 (40.0) 24 (52) 30 (67) 31 (68) 31 (68) 53 (117) 67 (147)
Thru-Drive, kg (lb) 15 (34) 22 (48) 27 (59) 34 (75) 35 (77) 35 (77) 55 (121) 82 (180)
Moment of Inertia kg·mm2 760 1555 3208 4548 5041 5041 12027 21400
Moment of Inertia Thru-Drive, kg·mm2 793 1618 3268 4687 5207 5207 12402 22343
*Intermittent is defined as less than 10% of operation time, not exceeding 20 successive seconds.
S 5 B
Pump Circuit Type Shaft Rotation Fluorocarbon Controls Port Work Port Paint
Family Options Seal Material Orientation Type
Displacement Mounting Single Configuration Design Additional Displacement Thru-Drive Special
& Ports Shaft Seal Series Control Options Stops Mounting Pad & Features
Coupling
Shaft Options
3 Requires application review. Consult factory.
Paint
01 SAE Spline
Additional Control Options
00 No Paint
02 SAE Keyed 0 No other options
PB Black Paint
04 ISO Keyed 2 Cam sensor (mandatory with P, T, S, U controls)
061 SAE Spline (18 & 100cc only) 34 Unload Valve - 12VDC (C0 or L0 control only) Special Features
08 SAE-B 13T Spline (28 & 45cc only) 64 Unload Valve - 24VDC (C0 or L0 control only) 00 Standard
09 SAE-BB 15T Spline (60cc only) 4 210 bar pressure limit (AG or AH control only) M2 Special Designation
SAE-B 13T Spline
10 7 280 bar pressure limit (AG or AH control only)
(60cc only; Not with thru drive)
1 18cc de-rated to 210 bar Torque Limiter
T
(45-140cc only; L0, AM, AN control only)
4 Available on 28-140cc only
S&A SAE J744 SAE-A 2-Bolt SAE-B 2-Bolt SAE-B 2-Bolt SAE-C 4-Bolt SAE-C 4-Bolt SAE-C 4-Bolt SAE-D 4-Bolt
ISO 80mm ISO 100mm ISO 100mm ISO 125mm ISO 125mm ISO 125mm ISO 180mm
M&B ISO 3019/2
2-Bolt 2-Bolt 2-Bolt 4-Bolt 4-Bolt 4-Bolt 4-Bolt
C&D SAE J744 N/A N/A N/A SAE-C 2-Bolt SAE-C 2-Bolt N/A N/A
J&K SAE J744 N/A N/A N/A SAE-B 2-Bolt N/A N/A N/A
Shaft Descriptions
02 SAE 19mm keyed SAE-BB keyed SAE-BB keyed SAE-C keyed SAE-C keyed SAE-CC keyed SAE-D keyed
04 ISO 20mm keyed ISO 25mm keyed ISO 25mm keyed ISO 32mm keyed ISO 32mm keyed ISO 40mm keyed DIN 50mm keyed
06 SAE-A 9T spline N/A N/A N/A N/A SAE-C 14T spline N/A
08 SAE-B 13T spline SAE-B 13T spline SAE-B 13T spline N/A N/A N/A N/A
P1/PD Displacement
Maximum Static Moment Nm 500 650 1000 1200 1600 1600 2200 3200
Distance L1 (no thru drive) mm 73 93 107 110 119 119 154 154
Distance L1 (thru drive) mm 104 113 115 123 134 134 179 185
Units 18 (1.1) 28 (1.71) 45 (2.75) 60 (3.66) 75 (4.58) 85 (5.19) 100 (6.1) 140 (8.54)
Nm 209
10 N/A N/A N/A N/A N/A N/A N/A
ft.lbs 155
Maximum Nm 134 210 293 318 329 329 538 760
through-drive
shaft torque ft.lbs 99 155 217 235 243 243 397 561
The P1/PD has gone through a design series change for some control options. All the controls shown in this catalog are now
standard as Design Series B (B-mod). For the C, L, and AM controls, the controls were combined into a single universal control
housing that can be used for any of the three options. See details below. Therefore, converting between those controls is very
easy. For conversion details or other service information on the B-mod, please refer to the P1/PD B-mod Service Manual HY28-
2708-02/SVC/EN. For service information on the Design Series A (A-mod), please refer to HY-28-2665-02/SVC/EN. Both service
manuals and all of the most recent P1/PD literature can be found at www.parker.com or directly at the Hydraulic Pump and
Power Systems Division homepage (www.parker.com/HPS).
Design Series A (C, L, & AM Controls) Design Series B (C, L, & AM Controls)
Tank
Pressure LS
Pressure
Bias or
Control
Control
or Bias
Pressure
Pmax
Tank Control
Standard NG6/D03 Pattern Custom Control Pad Pattern
NOTE: Bolt pattern & size remains the same. No change to housing casting required.
The "C0" pressure limiter control is used to limit the The "L0" and "L2" controls feature load sensing and
maximum system pressure. The control acts such that full maximum pressure compensation. A load sense line that
pump displacement is achieved unless the system valve comes from downstream of the main system throttling valve
restricts the output flow or the load pressure reaches the is connected to the "X" port on the control. This control
maximum setting of the control. If pump flow is restricted matches pump flow and pressure to system demands
by the system valve, the pump will provide only the flow by maintaining a constant pressure drop across the main
demanded, but at the maximum pressure setting of the system throttling valve, thus reducing horsepower losses.
compensator control. If the outlet flow is completely blocked, The pump automatically adjusts for changes in drive speed
the pump will destroke to zero displacement and maintain and load pressures. Choose the "L2" option if bleeding the
the pressure at the setting of the compensator spring. load sense line at the pump is desired.
flow
flow
pressure pressure
C0 Schematic L0 Schematic
The "AM" control allows the pump pressure compensator The "AN" control is a standard pressure compensator, but
setting to be adjusted from a remote relief valve that is with a NG6 ( D03) valve interface. It is the same as the "AM"
connected to the "X" port on the control. The control acts control, but with the addition of an adapter block mounted
such that full pump displacement is achieved unless the between the pump housing and control to provide the NG6
system valve restricts the output flow or the load pressure (D03) interface. This allows a directional valve or proportional
relief valve to be mounted directly on the pump to achieve a
reaches the maximum setting of the control. If pump flow is
variety of pressure control circuits.
restricted by the system valve, the pump will provide only the
flow demanded, but at the maximum pressure setting of the Caution: Pumps shipped with the “AN” control need to have
compensator control. If the outlet flow is completely blocked, a valve mounted to the NG6 interface for operation. This is
the pump will destroke to zero displacement and maintain not a functional control as shipped.
the pressure at the setting of the remote relief valve.
pilot-operated pressure limiter control pilot-operated control
4 bar maximum
flow
flow
pressure pressure
AM Schematic AN Schematic
80
60
0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
(35) (69) (105) (138) (174) (207) (243) (276) (316)
System Pressure- psi(bar)
90
100
75% Torque Setting
80 75%
Displacement - %
80 70
Full Torque - %
60
60 50 %
50
0 0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 0 500 1000 1500 2000 2500 3000 3500 4000 4500
(35) (69) (105) (138) (174) (207) (243) (276) (316) (35) (69) (105) (138) (174) (207) (243) (276) (316)
System Pressure- psi(bar) System Pressure- psi(bar)
This control is the same as the AN control, but with Note: The pressure relief valve has a command
the proportional relief valve included. It allows the range up to 350 bar, but P1/PD pump is rated to
pump pressure compensator setting to be adjusted 280 bar continuous pressure.
by an on-board 4VP0150G24B1C1 (24V) or
RE06M35W2N1KWXG087 (12V) proportional, electronic The following are options to drive the
relief valve. The control acts such that full pump proportional valve on the AE or AF pump:
displacement is achieved unless the system pressure
Parker Part# Description
reaches the setting of the proportional relief valve or the
027-22071-0 Dual Driver Module (12/24V)
mechanical pressure limiter. If pump flow is restricted
027-22067-0 Plug-Top-Driver 12V (0-10V command)
by the system, the pump will provide only the flow
027-22066-0 Plug-Top-Driver 24V (0-10V command)
demanded, but at the pressure setting of the proportional
or mechanical control. If the outlet flow is completely
Note: Consult Factory for more driver options and information.
blocked, the pump will destroke to zero displacement
and maintain the pressure at the setting of the control.
4 bar maximum
flow
pressure
4350 300
Electric Characteristics
3625 250
RE06 4VP01
Pressure
This control contains a cartridge valve that is integrated into “L03” & “L06” Controls - Load sensing &
the pump control to unload the pump into a low pressure pressure limiting with unload function
stand-by condition in order to reduce the torque required When the unload valve is in the spring position
to turn the pump. This control is often used in cold start (de-energized), the pump is “loaded”. The load sense
conditions when the hydraulic fluid is very cold and viscous. function requires the signal port be connected to load
The high fluid viscosity causes the pump to require more pressure, and the valve sends the load pressure to the
torque when initially starting, so this option can be used to spring side of the differential spool, so that a pressure
de-stroke the pump upon start-up in order to reduce the differential is created between the spring side of the
torque load on the engine to prevent it from stalling. spool and the system side allowing the control to
function like a standard load sensing control.
“LOADED” CONDITION
“C03” & “C06” Controls - Pressure limiting “UNLOADED” CONDITION
with unload function When the unload valve is in the energizes, the pump is
When the unload valve is in the spring position “unloaded”. This means the valve dumps the pressure
(de-energized), the pump is “loaded”. This means the valve on the spring side of the differential spool, activating that
sends system pressure to the spring side of the differential spool which sends pressure to the control piston of the
spool, so that pressure on both sides of that spool is equal. pump and allows the pump to de-stroke into a low pressure
Therefore, the spring setting prevents the differential spool stand-by condition.
from moving, so only the Pmax spool is active. Thus the
control behaves just like a standard pressure limiting control.
This control contains a Parker AP02B2YR35ALV proportional The proportional relief valve defaults to maximum
electronic pressure relief cartridge valve and mechanical displacement, so if no current is going to the valve then the
pressure limiter that are integrated into the pump control to pump goes to full displacement until the pressure setting
limit the maximum pressure of the pump either electronically of the mechanical pressure limiter is reached. Furthermore,
or mechanically. as current to the proportional relief valve is increased, the
pressure setting of the proportional relief decreases. This type
The control acts such that full pump displacement is of can is often used in fan drive applications so that maximum
achieved until the system pressure reaches the setting of cooling is achieved in the event of control signal loss.
the proportional relief or mechanical pressure limiter. If pump
flow is restricted by the system, the pump will provide only Note: For the "A*7" option, the pressure relief valve has a
the flow demanded, but at the pressure of the control setting. command range up to 350 bar, but P1/PD pump is rated
If the outlet flow is blocked, the pump will de-stroke to to 280 bar continuous pressure.
minimum displacement and maintain the pressure of the
control setting.
4 bar maximum
flow
pressure
The control uses the D1FB electronic proportional valve Cables are not included with the pump but
from Parker's Hydraulic Valve Division to provide the precise needed when ECU is purchased:
flow specified per a displacement input command and • 12-pin connector cable needed
maintain that flow level until a new displacement command • 6-pin connector cable needed
level is received, or until the pressure command overrides to • Com cable assembly
limit system pressure.
Parameters adjustment, calibration info and Interface
The holding current can vary from pump to pump, but is between ECU and Pump are described in the
typically between 1.3-1.6 Amps for the 12V valve and "Electronic Controls - Graphical User Interface
700-800 mA for the 24V valve. User Guide HY28-2674-01/P1/US"
A minimum of 25 bar servo pressure is required to control
the pump. To control the pump at system pressure below
25 bar, either a sequence valve in the pressure line or an
external servo source is required. Without adequate servo
pressure, the pump is biased on stroke.
Ø 3.7 CONNECTOR
CONNECTORB A RS232
CONNECTOR B Communication Cable
ASSY S2E-19180-0
35.3 Ordered Separately
35.3
16.0 MOUNTING RS232
HOLE HEIGHT Communication Cable
16.0 MOUNTING
101.6
HOLEController
RDEC HEIGHT ASSY S2E-19180-0
Ordered Separately
Dimensions for Reference Only
RDEC Controller
118.0
S2E-19254-0
Dimensions for Reference Only RS232
S2E-19254-0 Communication Cable
ASSY S2E-19180-0
CONNECTOR A Ordered Separately
CONNECTOR B
35.3
16.0 MOUNTING
HOLE HEIGHT
RDEC Controller
Dimensions for Reference Only
S2E-19254-0
P1/PD 018 Outlet Flow - Full Stroke P1/PD 028 Outlet Flow - Full Stroke
50c inlet oil temperature - ISO VG32 fluid 50c inlet oil temperature - ISO VG32 fluid
70 90
3200 rpm
80
60 2800 rpm
3200 rpm
70
2400 rpm
50 2800 rpm
Pump outlet flow (lpm)
0
0
0 50 100 150 200 250 300
0 50 100 150 200 250 300
Pump outlet pressure (bar)
Pump outlet pressure (bar)
P1/PD 045 Outlet flow - Full Stroke P1/PD 060 Outlet Flow - Full Stroke
50c inlet oil temperature, ISO VG32 fluid 50 C inlet oil temperature - ISO VG32 fluid - maximum displacement
130 150
2800 rpm 2400 rpm
120 140
130
110
2400 rpm
120
100
Pump outlet flow (lpm)
60
70 1200 rpm
1200 rpm
50
60
40 50
800 rpm 800 rpm
30 40
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)
P1/PD 075 Outlet Flow - Full Stroke P1/PD 085 Outlet Flow - Full Stroke
50 C inlet oil temperature - ISO VG32 fluid - maximum displacement 50 C inlet oil temperature - ISO VG 32 fluid - maximum displacement
180 200
2400 rpm 2400 rpm
170
160 180
150
160
140
1800 rpm
130 1800 rpm
140
120
1500 rpm
110
1500 rpm
120
100
90 1200 rpm
100 1200 rpm
80
70 80
800 rpm
60 800 rpm
50 60
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)
P1/PD 100 Outlet Flow - Full Stroke P1/PD 140 Outlet Flow - Full Stroke
50 C inlet oil temperature - ISO VG 32 fluid - maximum displacement 50 C inlet oil temperature - ISO VG 32 fluid - maximum displacement
220 300
2100 rpm
2100 rpm
280
200
260
180 1800 rpm 1800 rpm
240
Pump outlet flow (lpm)
160
220
1500 rpm
1500 rpm
140 200
120 180
1200 rpm
1200 rpm
160
100
140
80 800 rpm
120
800 rpm
60 100
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)
4.5
30
4.0
25
Shaft input power (kW)
3.5
15 1800 rpm
2.0 3200 rpm
1500 rpm
2800 rpm
1.5 1200 rpm
2100 rpm 10
800 rpm
1.0 1800 rpm
1500 rpm 5
0.5
800 rpm
0.0
0 50 100 150 200 250 300 0
0 50 100 150 200 250 300
Pump outlet pressure (bar)
Pump outlet pressure (bar)
5.5
45.0
5.0
40.0
4.5
Shaft input power (kW)
Shaft input power (kW)
9
60
8
50
Shaft input power (kW)
Shaft input power (kW)
7
2600 rpm
6 40
2400 rpm
5 1800 rpm
2600rpm 30
4 1500 rpm
2400rpm 1200 rpm
3 20
1800rpm 800 rpm
2 1500rpm
10
1200 rpm
1
800 rpm
0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)
80 2400 rpm
12
70
10
Shaft input power (kW)
8 1500 rpm
50
40 1200 rpm
6
2400 rpm
30 800 rpm
4 1800 rpm
1500 rpm 20
2
1200 rpm
10
800 rpm
0
0
0 50 100 150 200 250 300
0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)
80
12 2300 rpm
70
10
Shaft input power (kW)
1800 rpm
60
8 1500 rpm
50
40 1200 rpm
6
2300 rpm 30
800 rpm
4 1800 rpm
20
1500 rpm
2 1200 rpm
10
800 rpm
0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)
60 1500 rpm
8 50 1200 rpm
6 40
800 rpm
2300 rpm 30
4
1800 rpm
20
1500 rpm
2
1200 rpm 10
800 rpm
0 0
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)
14 2100 rpm
100
2100 rpm
1800 rpm
12
1800 rpm
Shaft input power (kW)
6
40 800 rpm
20
2
0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)
12
1500 rpm
800 rpm 100
10
80 1200 rpm
8
60 800 rpm
6
4 40
2 20
0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)
P1/PD 018 Shaft Bearing L-10 Life (Max Displacement) P1/PD 028 Shaft Bearing L-10 Life (Max Displacement)
1,000,000 1,000,000
1500 rpm
Shaft bearing L-10 life (hours)
1200 rpm
5,000
1,000 1,000
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Duty cycle average pump outlet pressure (bar) Duty cycle average pump outlet pressure (bar) 0
0 50 100
Duty cycle av
P1/PD 045 Shaft Bearing L-10 Life (Max Displacement) P1/PD 060 Shaft Bearing L-10 Life (Max Displacement)
1,000,000 1,000,000
2400 rpm
1800 rpm
Shaft bearing L-10 life (hours)
1200 rpm
1500 rpm
10,000 10,000
1800 rpm
2600 rpm
1,000 1,000
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Duty cycle average pump outlet pressure (bar) Duty cycle average pump outlet pressure (bar)
600 rpm
1,000 1,000
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Duty cycle average pump outlet pressure (bar) Duty cycle average pump outlet pressure (bar)
100,000 100,000
600 rpm 2000 rpm
1200 rpm
1500 rpm
1500 rpm
10,000 10,000 1200 rpm
1800 rpm
1000 rpm
2100 rpm
600 rpm
1,000 1,000
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Duty cycle average pump outlet pressure (bar) Duty cycle average pump outlet pressure (bar)
P1 018 Sound Levels (Zero Flow) P1 018 Sound Levels (Full Flow)
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
90 90
85 85
80 80
Sound pressure level dB(A)
75 3000 rpm 75
2100 rpm
70 2100 rpm 70
1000 rpm
65 65
1000 rpm
60 60
55 55
50 50
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)
P1 028 Sound Levels (Zero Flow) P1 028 Sound Levels (Full Flow)
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
90 90
85 85
80 80
Sound pressure level dB(A)
3000 rpm
75 3000 rpm 75
70 70 2100 rpm
2100 rpm
65 65
1000 rpm 1000 rpm
60 60
55 55
50 50
0 50 100 150 200 250 300 0 50 100 150 200 250 300
Pump outlet pressure (bar) Pump outlet pressure (bar)
P1 045 Sound Levels (Zero Flow) P1 045 Sound Levels (Full Flow)
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
85 83
2600 rpm 81
2600 rpm
79
80
Sound pressure level dB(A)
Sound pressure level dB(A)
2100 rpm 77
75 2100 rpm
75
73
1200 rpm
71
70
69 1200 rpm
67
65 65
50 100 150 200 250 300 0 50 100 150 200 250 300
P1 060 Mobile Pump Typical Sound Level P1 075/085 Mobile Pump Typical Sound Level
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
90 90
2400 rpm 2300 rpm
80
80
75
75
70
solid lines are for maximum displacement and dashed lines are for zero flow solid lines are for maximum displacement and dashed lines are for zero flow
70 65
50 100 150 200 250 300 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)
P1 100 Mobile Pump Typical Sound Level P1 140 Mobile Pump Typical Sound Level
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
90 90
2100 rpm
solid lines are for maximum displacement and dashed lines are for zero flow 2000 rpm
1800 rpm
1800 rpm
85 1500 rpm 85
1500 rpm
Sound pressure level dB(A)
Sound pressure level dB(A)
1200 rpm
1200 rpm
1000 rpm
80 80 1000 rpm
75 75
70 70
solid lines are for maximum displacement and dashed lines are for zero flow
65 65
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)
PD 018 Sound Levels (Zero Flow) PD 018 Sound Levels (Full Flow)
ISO VG32 fluid - 50C inlet oil temperature ISO VG32 fluid - 50C inlet oil temperature
80 80
75 75
1500 rpm 1500 rpm
70 70
60 60
55 55
50 50
0 50 100 150 200 250 300 0 50 100 150 200 250 300
PD 028 Sound Levels (Zero Flow) PD 028 Sound Levels (Full Flow)
ISO VG32 fluid - 50C inlet oil temperature ISO VG32 fluid - 50C inlet oil temperature
80 80
70 70
65 65
60 60 1000 rpm
1000 rpm
55 55
solid lines are for maximum displacement and dashed lines are for zero flow
50 50
0 50 lines are for maximum
100 150 and dashed200 250 300 0 50 100 150 200 250 300
solid displacement lines are for zero flow
Pump outlet pressure (bar) Pump outlet pressure (bar)
PD 045 Sound Levels (Zero Flow) PD 045 Sound Levels (Full Flow)
ISO VG32 fluid - 50C inlet oil temperature ISO VG32 fluid - 50C inlet oil temperature
74 78
76
72
1800 rpm
74
Sound pressure level dB(A)
Sound pressure level dB(A)
70 1500 rpm
72
1200 rpm
68 70 1800 rpm
66 68 1500 rpm
66 1200 rpm
64
64
62
62
60 60
50 100 150 200 250 300 0 50 100 150 200 250 300
Pump output pressure (bar) Pump outlet pressure (bar)
solid lines are for maximum displacement and dashed lines are for zero flow
solid lines are for maximum displacement and dashed lines are for zero flow
PD 060 Industrial Pump Typical Sound Level PD 075/085 Industrial Pump Typical Sound Level
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
85 85
80 80 1500 rpm
1500 rpm
75 75
70 70
solid lines are for maximum displacement and dashed lines are for zero flow solid lines are for maximum displacement and dashed lines are for zero flow
65 65
60 60
0 50 100 150 200 250 300 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)
PD 100 Industrial Pump Typical Sound Level PD 140 Industrial Pump Typical Sound Level
anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature anechoic conditions - ISO VG 32 fluid - 50 C inlet oil temperature
85 85
1800 rpm
solid lines are for maximum displacement and dashed lines are for zero flow 1800 rpm
1500 rpm
1500 rpm
80
Sound pressure level dB(A)
80 1200 rpm
Sound pressure level dB(A)
1200 rpm
75
75
70
70
65
solid lines are for maximum displacement and dashed lines are for zero flow
60 65
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350
Pump outlet pressure (bar) Pump outlet pressure (bar)
Dimension ISO Key (Code 04) SAE (Code 01 or 02) SAE (Code 06)
CA ISO 3019-2: 80A2SW SAE J744: JUN 96 82-2 (A) SAE J744: JUN 96 82-2 (A)
“L” or “AM” Control Option "A" Inlet 1" Code 61 SAE-16 DN25 M33x2 -
“L” or “AM” Control Option "A" Inlet 1-1/4" Code 61 SAE-20 DN32 M42x2 -
W Threads 7/16-14 UNC-2B - M10x1.5-6H - -
"B" Outlet 3/4" Code 61 SAE-12 DN19 M27x2 -
Y Threads 3/8-16 UNC-2B - M10x1.5-6H - -
BG, X SAE-4 M12x1.5 1/4"
D1, D2, D3 SAE-8 M22x1.5 1/2"
Side Ports with Thru-Drive SAE Flanged SAE Threaded Metric Flanged Metric Threaded BSPP
"A" Inlet 1-1/2" Code 61 SAE-24 DN38 M48x2 -
“L” or “AM” Control Option W Threads 1/2-13 UNC-2B - M12x1.75-6H - -
"B" Outlet 1" Code 61 SAE-16 DN25 M33x2 -
Side Ports with Thru-Drive Ports SAE Flanged Metric Flanged BSPP
SAE-A
SAE-A Mounting Options Information
Model Number T0*A
Spline: ANSI B92.1 1996
SAE 16-4 (A) Involute Spline
Class 7 Flat Root Side Fit
Number of Teeth - 9
Pitch - 16/32
Pressure Angle - 30°
Major Diameter - 13.06/12.93 mm
Pitch Diameter - 14.29 mm
Model Number T0*H
Spline: ANSI B92.1 1996
SAE 19-4 Involute Spline
Class 7 Flat Root Side Fit
Number of Teeth - 11
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 16.14/16.02 mm
Pitch Diameter - 17.46 mm
SAE-B
SAE-B Mounting Options Information
Model Number T0*B
Spline: ANSI B92.1 1996
SAE 22-4 (B) Involute Spline
Class 7 Flat Root Side Fit
Number of Teeth - 13
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 19.28/19.15 mm
Pitch Diameter - 20.64 mm
Model Number T0*Q
Spline: ANSI B92.1 1996
SAE 25-4 (B-B) Involute Spline
Class 7 Flat Root Side Fit
Number of Teeth - 15
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 22.40/22.28 mm
Pitch Diameter - 23.81 mm
SAE-C
Pump Installation - P1/PD-075 & 085 P1/PD-075 & 085 Port Sizes
Side Ports with Thru-Drive Ports SAE Flanged Metric Flanged BSPP
SAE-C
Dimension ISO (Code 04) SAE (Code 01 or 02) SAE (Code 06)
Side Ports with Thru-Drive Ports SAE Flanged Metric Flanged BSPP
SAE-A
SAE-A Mounting Options Information
Model Number T0*A
Spline: ANSI B92.1 1996
SAE 16-4 (A) Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 9
Pitch - 16/32
Pressure Angle - 30°
Major Diameter - 13.06/12.93 mm
Pitch Diameter - 14.29 mm
Model Number T0*H
Spline: ANSI B92.1 1996
SAE 19-4 Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 11
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 16.14/16.02 mm
Pitch Diameter - 17.46 mm
SAE-B
SAE-B Mounting Options Information
Model Number T0*B
Spline: ANSI B92.1 1996
SAE 22-4 (B) Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 13
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 19.28/19.15 mm
Pitch Diameter - 20.64 mm
Model Number T0*Q
Spline: ANSI B92.1 1996
SAE 25-4 (B-B) Involute Spline
Class 5 Flat Root Side Fit
Number of Teeth - 15
Pitch - 16/32
Pressure Angle - 30°
Minor Diameter - 22.40/22.28 mm
Pitch Diameter - 23.81 mm
SAE-C
SAE-C Mounting Options Information
Model Number T0*C
Spline: ANSI B92.1 1996
SAE 32-4 (C) Involute Spline
Class 1 Flat Root Side Fit
Number of Teeth - 14
Pitch - 12/24
Pressure Angle - 30°
Minor Diameter - 27.74/27.61 mm
Pitch Diameter - 29.63 mm
Model Number T0*N
Spline: ANSI B92.1 1996
SAE 38-4 (C-C) Involute Spline
Class 1 Flat Root Side Fit
Number of Teeth - 17
Pitch - 12/24
Pressure Angle - 30°
Minor Diameter - 34.01/33.88 mm
Pitch Diameter - 35.98 mm
AB 53.50/53.21 49.43/49.17
AC 92.8/91.2 75.8/74.2
BA N/A 39.0
BB N/A 67.0
BC N/A 75.0
CB 18.2/17.8 20.9/20.5
CC 79.2 80.8
CD 158.4 161.6
CE 180.00/179.95 152.40/152.35
CF 9.5/9.0 12.7/12.2
Side Ports with Thru-Drive Ports SAE Flanged Metric Flanged BSPP
C0 Control
For C0 control dimensions see frame size dimensional section because the C0
control uses the same control housing as L & AM controls.
P*075 shown
P*060 shown
P*060 60 82 159 25 94
P*075/085 70 85 169 28 97
P*100 117 101 216 58 113
P*140 129 113 228 51 125
P*075 shown
Parker Hannifin Corporation
Hydraulic Pump and Power Systems Division
United States 63
HY28-2665-01/P1/EN | April 2021 Axial Piston Pumps
Dimensional Data - Controls P1/PD Series
P*075 shown
AG/AH Control
CCW ORIENTATION
P*075 shown
CW ORIENTATION
P*075 shown
Cam Sensor
Pressure Compensator
Adjusting Screw
Mounting These pumps are designed to operate with the shaft horizontal or pointing downward.
For shaft up mounting consult factory. The pump shaft must be in alignment with the shaft
of the source driver and should be checked with a dial indicator. The mating pilot bore and
coupling must be concentric. This concentricity is particularly important if the shaft is rigidly
connected to the driven load without a flexible coupling.
Shaft Information Splined: The shafts will accept a maximum misalignment of 0.15mm, 0.005 inch, total
indicator reading. Angular misalignment at the external and internal spline axis must be
less than ± 0,002 mm per mm of shaft radius, ± 0.002 inches per inch of shaft radius.
The coupling interface must be lubricated. PARKER recommends lithium molydisulfide or
similar grease. The internal coupling should be hardened to Rc 27-34 and must conform to
SAE-J498c, class 5 flat root side fit.
Keyed: High strength heat treated keys must be used. Replacement keys must be hardened
to 27-34 Rc. The key corners must be chamfered 0.81-1.0 mm, 0.032”-0.040”, at 45° to
clear radii that exist in the keyway.
Side Load Capacity The P1/PD series is designed for inline-drive. Side loading on the shaft is not recommended.
If this is unavoidable consult your nearest PARKER representative.
Fluid Connections Connect inlet and outlet lines to the port block of the pump. The maximum case pressure is
2 bar (30 psi) continuous, 4 bar (60 psi) intermittent. The case pressure must never exceed
inlet pressure by more than .5 bar (7 psi). When connecting case drain line make certain that
drain plumbing passes above highest point of the pump before passing to the reservoir. The
case leakage line must be of sufficient size to prevent back pressure in excess of 2 bar(30
psi) and returned to the reservoir below the surface of the oil as far from the supply inlet as
possible. All fluid lines, whether pipe, tubing, or hose must be adequate size and strength
to assure free flow through the pump. An undersize inlet line will prevent the pump from
operating properly at full rated speed. An undersize outlet line will cause back pressure and
cause heat generation and increased noise. Flexible hose lines are recommended. If rigid
piping is used, the workmanship must be accurate to eliminate strain on the pump port block
or to the fluid connections. Sharp bends in the lines must be eliminated wherever possible.
All system piping must be cleaned and flushed before installing pump. Make sure the entire
hydraulic system is free of dirt, lint, scale, or other foreign material.
CAUTION: Do not use galvanized pipe. Galvanized coating can flake off with continued use.
System Relief Valves Although the P1/PD series pumps have very fast off-stroke compensator response, system
relief valves are recommended in all cases for safety considerations.
Recommended Fluids The fluid recommended for use in these pumps has a petroleum base and contains agents
which provide oxidation inhibition and anti-rust, anti-foam and de-aerating properties as
described in PARKER standard HF-1. Where anti-wear additive fluids are specified, see
PARKER standard HF-0.
Viscosity Index 90 V. I. minimum. Higher values extend the range of operating temperature but may reduce
the service life of the fluid.
Temperature Determined by the viscosity characteristics of the fluid used. Because high temperatures
degrade seals, reduce the service life of the fluid and create hazards, fluid temperature
should not exceed 110°C (230°F) at the case drain.
Maintenance The pump is self-lubricating and preventative maintenance is limited to keeping system
fluid clean by changing filters frequently. Keep all fittings and screws tight. Do not operate
at pressures and speeds in excess of the recommended limit. If the pump does not operate
properly, check the troubleshooting chart before attempting to overhaul the unit. Overhauling
may be accomplished by referring to the disassembly, rework limits of wear parts, and
assembly procedures as provided in this service manual.
Fluid Cleanliness Fluid must be cleaned before and continuously during operation, by filters that maintain a
cleanliness level of ISO 20/18/14. Better cleanliness levels will significantly extend the life
of the components. As contaminant generation may vary with each application, each must
be analyzed to determine proper filtration to maintain the required cleanliness level.
CONVERSION FACTORS
DEFINITION & UNIT
Displacement in3/rev x 16.387 = cm3/rev cm3/rev x 0.06102 = in3/rev
Flow gpm x 3.78 = L/min L/min x 0.2642 = gpm
Power hp x 0.7457 = kW kW x 1.341 = hp
Torque lb-ft x 1.3567 = Nm Nm x 0.7376 = lb-ft
Pressure lbs/in2 (psi) x 0.06895 = bar bar x 14.50 = lbs/in2 (psi)
lbs/in2 (psi) x 6.895 = kPa kPa x 0.1450 = lbs/in2 (psi)
Weight lb x 0.4536 = kg kg x 2.205 = lbs
Force lb x 4.448 = N N x 0.2248 = lbs
Volume in3 x 16.387 = cm3 cm3 x 0.06102 = in3
Area in2 x 6.452 = cm2 cm2 x 0.1550 = in2
Length in x 25.4 = mm mm x 0.03937 = in
Temperature
degree F-32 = °C 1.8 x C+32 = °F
1.8
Viscosity cSt x 1.0 = mm2/sec mm2/sec x 1.0 = cSt
SSU = cSt x 4.25 + 14 20 cSt = 99 SSU
Piston, bladder and Self-contained with a motor, Standard and custom Parker’s unique IQAN approach
diaphragm type accumulators, gear pump, reservoir, internal hydraulic cylinders for combines sturdy, well-tested
gas bottles and KleenVent valving, load hold checks and industrial and mobile hardware with intelligent, flexible
reservoir isolators. relief valves. applications. computing power.
www.parker.com/accumulator www.parker.com/oildyne www.parker.com/cylinder www.parker.com/iqan
Pressure and return line Solutions for complex circuits Full line of high and low Parker Chelsea leads the
filters enhances machine that include threaded cartridge speed motors provides industry for engineering,
life, reduces maintenance valves integrated into a single power up to 15,000 in-lbs innovation and performance
and lowers costs. manifold. of torque. in auxiliary power systems.
www.parker.com/hydraulicfilter www.parker.com/hcs www.parker.com/hps www.parker.com/chelsea
The most complete line of Broad line of energy-efficient Industry leader in the Hydraulic valves for virtually
standard, pre-engineered, hydraulic pumps that includes design and manufacture every hydraulic equipment
cataloged hydraulic power piston, vane and gear pumps. of hydraulic rack and pinion, application, from simple to
units in the industry. and vane style rotary actuators. precise control.
www.parker.com/hps www.parker.com/hps www.parker.com/cylinder www.parker.com/hydraulicvalve
The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, Hydraulics Group, and its authorized distributors (“Seller”) are
hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions.
Buyer’s order for any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All goods or work described will be
referred to as “Products”.
1. Terms and Conditions. Seller’s willingness to offer Products, or accept an order for 11. Buyer’s Obligation; Rights of Seller. To secure payment of all sums due or otherwise,
Products, to or from Buyer is expressly conditioned on Buyer’s assent to these Terms and Seller shall retain a security interest in the goods delivered and this agreement shall be
Conditions and to the terms and conditions found on-line at www.parker.com/saleterms/. deemed a Security Agreement under the Uniform Commercial Code. Buyer authorizes
Seller objects to any contrary or additional term or condition of Buyer’s order or any other Seller as its attorney to execute and file on Buyer’s behalf all documents Seller deems
document issued by Buyer. necessary to perfect its security interest. Seller shall have a security interest in, and lien
2. Price Adjustments; Payments. Prices stated on the reverse side or preceding pages upon, any property of Buyer in Seller’s possession as security for the payment of any
of this document are valid for 30 days. After 30 days, Seller may change prices to reflect amounts owed to Seller by Buyer.
any increase in its costs resulting from state, federal or local legislation, price increases 12. Improper Use and Indemnity. Buyer shall indemnify, defend, and hold Seller harmless
from its suppliers, or any change in the rate, charge, or classification of any carrier. The from any claim, liability, damages, lawsuits, and costs (including attorney fees), whether for
prices stated on the reverse or preceding pages of this document do not include any sales, personal injury, property damage, patent, trademark or copyright infringement or any other
use, or other taxes unless so stated specifically. Unless otherwise specified by Seller, all claim, brought by or incurred by Buyer, Buyer’s employees, or any other person, arising out
prices are F.O.B. Seller’s facility, and payment is due 30 days from the date of invoice. After of: (a) improper selection, improper application or other misuse of Products purchased by
30 days, Buyer shall pay interest on any unpaid invoices at the rate of 1.5% per month or Buyer from Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Seller’s use
the maximum allowable rate under applicable law. of patterns, plans, drawings, or specifications furnished by Buyer to manufacture Product;
3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate and or (d) Buyer’s failure to comply with these terms and conditions. Seller shall not indemnify
Seller shall not be responsible for any damages resulting from any delay. Regardless of the Buyer under any circumstance except as otherwise provided.
manner of shipment, title to any products and risk of loss or damage shall pass to Buyer 13. Cancellations and Changes. Orders shall not be subject to cancellation or change
upon tender to the carrier at Seller’s facility (i.e., when it’s on the truck, it’s yours). Unless by Buyer for any reason, except with Seller’s written consent and upon terms that will
otherwise stated, Seller may exercise its judgment in choosing the carrier and means indemnify, defend and hold Seller harmless against all direct, incidental and consequential
of delivery. No deferment of shipment at Buyers’ request beyond the respective dates loss or damage. Seller may change product features, specifications, designs and avail-
indicated will be made except on terms that will indemnify, defend and hold Seller harmless ability with notice to Buyer.
against all loss and additional expense. Buyer shall be responsible for any additional ship- 14. Limitation on Assignment. Buyer may not assign its rights or obligations under this
ping charges incurred by Seller due to Buyer’s changes in shipping, product specifications agreement without the prior written consent of Seller.
or in accordance with Section 13, herein. 15. Entire Agreement. This agreement contains the entire agreement between the Buyer
4. Warranty. Seller warrants that the Products sold hereunder shall be free from defects and Seller and constitutes the final, complete and exclusive expression of the terms of the
in material or workmanship for a period of eighteen months from the date of delivery to agreement. All prior or contemporaneous written or oral agreements or negotiations with
Buyer. The prices charged for Seller’s products are based upon the exclusive limited respect to the subject matter are herein merged.
warranty stated above, and upon the following disclaimer: DISCLAIMER OF WARRANTY: 16. Waiver and Severability. Failure to enforce any provision of this agreement will not
THIS WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TO waive that provision nor will any such failure prejudice Seller’s right to enforce that provision
PRODUCTS PROVIDED HEREUNDER. SELLER DISCLAIMS ALL OTHER WARRAN- in the future. Invalidation of any provision of this agreement by legislation or other rule of
TIES, EXPRESS AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR A law shall not invalidate any other provision herein. The remaining provisions of this agree-
PARTICULAR PURPOSE. ment will remain in full force and effect.
5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon 17. Termination. This agreement may be terminated by Seller for any reason and at
delivery. No claims for shortages will be allowed unless reported to the Seller within 10 any time by giving Buyer thirty (30) days written notice of termination. In addition, Seller
days of delivery. No other claims against Seller will be allowed unless asserted in writing may by written notice immediately terminate this agreement for the following: (a) Buyer
within 60 days after delivery or, in the case of an alleged breach of warranty, within 30 commits a breach of any provision of this agreement (b) the appointment of a trustee,
days after the date within the warranty period on which the defect is or should have been receiver or custodian for all or any part of Buyer’s property (c) the filing of a petition for relief
discovered by Buyer. Any action based upon breach of this agreement or upon any other in bankruptcy of the other Party on its own behalf, or by a third party (d) an assignment for
claim arising out of this sale (other than an action by Seller for any amount due to Seller the benefit of creditors, or (e) the dissolution or liquidation of the Buyer.
from Buyer) must be commenced within thirteen months from the date of tender of delivery 18. Governing Law. This agreement and the sale and delivery of all Products hereunder
by Seller or, for a cause of action based upon an alleged breach of warranty, within thirteen shall be deemed to have taken place in and shall be governed and construed in accor-
months from the date within the warranty period on which the defect is or should have dance with the laws of the State of Ohio, as applicable to contracts executed and wholly
been discovered by Buyer. performed therein and without regard to conflicts of laws principles. Buyer irrevocably
6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS OPTION, agrees and consents to the exclusive jurisdiction and venue of the courts of Cuyahoga
REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE PURCHASE PRICE. County, Ohio with respect to any dispute, controversy or claim arising out of or relating
IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL, INDIRECT, to this agreement. Disputes between the parties shall not be settled by arbitration unless,
INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS THE RESULT after a dispute has arisen, both parties expressly agree in writing to arbitrate the dispute.
OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS OF USE OF THE 19. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no
PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR EXPENSES OF ANY liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets
NATURE INCURRED WITHOUT SELLER’S WRITTEN CONSENT, EVEN IF SELLER HAS or similar rights except as provided in this Section. Seller will defend and indemnify Buyer
BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR OTHER LEGAL THEORY. IN against allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade
NO EVENT SHALL SELLER’S LIABILITY UNDER ANY CLAIM MADE BY BUYER EXCEED dress and trade secrets (“Intellectual Property Rights”). Seller will defend at its expense
THE PURCHASE PRICE OF THE PRODUCTS. and will pay the cost of any settlement or damages awarded in an action brought against
7. Contingencies. Seller shall not be liable for any default or delay in performance if Buyer based on an allegation that a Product sold pursuant to this Agreement infringes
caused by circumstances beyond the reasonable control of Seller. the Intellectual Property Rights of a third party. Seller’s obligation to defend and indemnify
8. User Responsibility. The user, through its own analysis and testing, is solely responsible Buyer is contingent on Buyer notifying Seller within ten (10) days after Buyer becomes
for making the final selection of the system and Product and assuring that all performance, aware of such allegations of infringement, and Seller having sole control over the defense
endurance, maintenance, safety and warning requirements of the application are met. The of any allegations or actions including all negotiations for settlement or compromise. If a
user must analyze all aspects of the application and follow applicable industry standards Product is subject to a claim that it infringes the Intellectual Property Rights of a third party,
and Product information. If Seller provides Product or system options, the user is respon- Seller may, at its sole expense and option, procure for Buyer the right to continue using the
sible for determining that such data and specifications are suitable and sufficient for all Product, replace or modify the Product so as to make it noninfringing, or offer to accept
applications and reasonably foreseeable uses of the Products or systems. return of the Product and return the purchase price less a reasonable allowance for depre-
9. Loss to Buyer’s Property. Any designs, tools, patterns, materials, drawings, confi- ciation. Notwithstanding the foregoing, Seller shall have no liability for claims of infringe-
dential information or equipment furnished by Buyer or any other items which become ment based on information provided by Buyer, or directed to Products delivered hereunder
Buyer’s property, may be considered obsolete and may be destroyed by Seller after two for which the designs are specified in whole or part by Buyer, or infringements resulting
consecutive years have elapsed without Buyer placing an order for the items which are from the modification, combination or use in a system of any Product sold hereunder. The
manufactured using such property. Seller shall not be responsible for any loss or damage foregoing provisions of this Section shall constitute Seller’s sole and exclusive liability and
to such property while it is in Seller’s possession or control. Buyer’s sole and exclusive remedy for infringement of Intellectual Property Rights.
10. Special Tooling. A tooling charge may be imposed for any special tooling, including 20. Taxes. Unless otherwise indicated, all prices and charges are exclusive of excise,
without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. sales, use, property, occupational or like taxes which may be imposed by any taxing
Such special tooling shall be and remain Seller’s property notwithstanding payment of any authority upon the manufacture, sale or delivery of Products.
charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging to 21. Equal Opportunity Clause. For the performance of government contracts and where
Seller which is utilized in the manufacture of the Products, even if such apparatus has been dollar value of the Products exceed $10,000, the equal employment opportunity clauses
specially converted or adapted for such manufacture and notwithstanding any charges in Executive Order 11246, VEVRAA, and 41 C.F.R. §§ 60-1.4(a), 60-741.5(a), and 60-250.4,
paid by Buyer. Unless otherwise agreed, Seller shall have the right to alter, discard or are hereby incorporated.
otherwise dispose of any special tooling or other property in its sole discretion at any time.
March 2020 Corrected AN, AE/AF, & 45 & 60 L0T/AMT control images
Corrected minor miscellaneous errors
WARNING
The products described in this catalog can expose you to chemicals, including Lead, which is known to the State of California to cause cancer and birth defects or other
reproductive harm. For more information go to www.p65warnings.ca.gov.