ARKEL ARLINE
REMOTE ALARM, MONITORING AND INTERCOM SYSTEM
FOR LIFTS
USER MANUAL
Arkel ArLine User Manual V1.23
This document has been created to be a guide for Arkel customers. Reproduction, transfer, distribution or storage of part or all
the contents in this document in any form without the prior written permission of Arkel is prohibited. Arkel reserves the right to
make changes and improvements to any of the products described in this document without prior notice.
Arkel is not responsible for those mistakes that may be found in this manual and for the damages that they may cause.
Arkel ArLine User Manual V1.23
TABLE OF CONTENT
1. SAFETY PRECAUTIONS ................................................................................................................................................. 5
2. GENERAL INFORMATION ............................................................................................................................................. 5
3. PACKAGE CONTENTS .................................................................................................................................................... 5
4. TECHNİCAL SPECIFICATIONS .................................................................................................................................... 6
4.1. ARKEL ARLINE-M TECHNICAL SPECIFICATIONS ........................................................................................................... 6
4.2. ARKEL ARLINE-S-COP TECHNICAL SPECIFICATIONS ................................................................................................... 7
4.3. ARKEL ARLINE-S-TP TECHNICAL SPECIFICATIONS ...................................................................................................... 7
4.4. ARKEL ARLINE-S-INT TECHNICAL SPECIFICATIONS .................................................................................................... 7
5. OVERVIEW ........................................................................................................................................................................ 8
5.1. GENERAL OVERVIEW .................................................................................................................................................... 8
5.2. OVERVIEW ARKEL ARLINE-M ...................................................................................................................................... 9
5.3. OVERVIEW ARKEL ARLINE-S-COP ............................................................................................................................. 10
5.4. OVERVIEW ARKEL ARLINE-S-TP ................................................................................................................................ 10
5.5. OVERVIEW ARKEL ARLINE-S-INT .............................................................................................................................. 11
6. INSTALLATION .............................................................................................................................................................. 11
6.1. INSTALLATION OF ARKEL ARLINE-M .......................................................................................................................... 11
6.2. INSTALLATION OF ARKEL ARLINE-S-COP .................................................................................................................. 11
6.3. INSTALLATION OF ARKEL ARLINE-S-TP ..................................................................................................................... 12
6.4. INSTALLATION OF ARKEL ARLINE-S-INT ................................................................................................................... 12
7. CONNECTIONS ............................................................................................................................................................... 13
7.1. ARKEL ARLINE-M CONNECTIONS ............................................................................................................................... 13
7.2. ARKEL ARLINE-S-COP CONNECTIONS ....................................................................................................................... 14
7.3. ARKEL ARLINE-S-TP/ARKEL ARLINE-S-INT CONNECTIONS ..................................................................................... 16
8. ARKEL ARLINE-S-TP/ARKEL ARLINE-S-INT DIP-SWITCH SETTINGS........................................................... 16
9. ARKEL ARLINE-S SOUND ADJUSTMENT ................................................................................................................ 16
10. USING THE BUTTON ON THE ARKEL ARLINE-M ................................................................................................ 16
11. LED INFORMATION ...................................................................................................................................................... 17
11.1. ARKEL ARLINE-M LED INFORMATİON ....................................................................................................................... 17
11.2. ARKEL ARLINE-S-COP LED INFORMATİON ............................................................................................................... 17
11.2. ARKEL ARLINE-S-TP LED INFORMATİON .................................................................................................................. 17
11.3. ARKEL ARLINE-S-INT LED INFORMATİON ................................................................................................................ 18
12. INPUT FUNCTIONS ........................................................................................................................................................ 18
13. OUTPUT (RELAY) FUNCTIONS .................................................................................................................................. 19
14. SIM CARD ......................................................................................................................................................................... 19
14.2. SIM CARD SPECIFICATIONS ........................................................................................................................................ 19
14.3. REMOVING THE PIN CODE .......................................................................................................................................... 19
14.4. INSERTING/REMOVING THE SIM CARD ....................................................................................................................... 19
15. ALARM .............................................................................................................................................................................. 19
16. INTERCOM ....................................................................................................................................................................... 22
17. AUTOMATIC COMMUNICATION TEST (3 DAYS TEST) ...................................................................................... 22
18. BATTERY .......................................................................................................................................................................... 23
18.1. BATTERY TEST ............................................................................................................................................................ 23
18.2. BATTERY TEST ............................................................................................................................................................ 23
18.3. REPLACING THE BATTERY ........................................................................................................................................... 23
19. ARKEL CLOUD SYSTEM .............................................................................................................................................. 24
19.1. SETTING THE PRİMARY USER AND ADDİNG USERS...................................................................................................... 24
19.2. ADDING BUILDINGS ..................................................................................................................................................... 25
19.3. ADDING DEVICES ........................................................................................................................................................ 25
20. ARKEL CLOUD ARKEL ARLINE INTERFACE........................................................................................................ 25
20.1. INFORMATION .............................................................................................................................................................. 25
20.2. ELEVATOR ERRORS ..................................................................................................................................................... 25
20.3. ARKEL ARLINE SETTINGS ........................................................................................................................................... 26
20.4. EVENT LOGS ................................................................................................................................................................ 28
20.5. ADDING EMERGENCY CALL RECIPIENTS ..................................................................................................................... 28
21. REMOTE UPDATE .......................................................................................................................................................... 29
22. INSPECTION AND TESTING BEFORE THE LIFT ARE TAKEN INTO SERVICE (EN 81-28:2018, 6.3) ......... 29
22.1. ALARM ........................................................................................................................................................................ 29
22.2. END OF ALARM ........................................................................................................................................................... 29
22.3. EMERGENCY ELECTRIC POWER SUPPLY ...................................................................................................................... 29
22.4. INFORMATION IN THE LIFT CAR .................................................................................................................................... 29
22.5. COMMUNICATION ........................................................................................................................................................ 29
Arkel ArLine User Manual V1.23
1. Safety Precautions
• This product is designed and manufactured for use in lifts only.
• This product should be operated only by personnel authorized and trained on lift.
• The personnel must comply with all applicable health and safety requirements and standards related to the product.
• This product and its related connections must only be located in the areas which are accessible to the lift but not
accessible to unauthorized persons.
• For proper operation of the product, the instructions given in this manual and the other relevant guidelines must be
followed.
• The device should be de-energized before the SIM card, the GSM antenna and the other connections are made.
• The product must be installed in a way that it is protected from the effects of the environment (Water, moisture,
excessive dust, high temperature, etc.) which may cause damage.
• The product must not be used where there is a risk of explosion and where chemicals are used to a large extent.
• In order to ensure that the remote alarm system is kept in operational condition without interruption, and to take
necessary measures in case of a malfunction; the lift maintenance company, the lift owner and the rescue
service/personnel must be aware of and fulfill their duties. (See also EN 81-28 and EN 13015).
• ARKEL assumes no responsibility for accidents, flaws or possible defects caused by the user's lack of information or
carelessness. The same condition applies to all modifications to the product, except for ARKEL approval.
• ARKEL reserves the right to make changes in the product and this manual for functional or commercial reasons.
2. General Information
• Arkel ArLine is a remote alarm system designed for lifts. It complies with EN 81-28, EN 81-20 and EN 81-70 standards.
In addition to the remote alarm system, it can also function as an intercom system as required in EN 81-20.
• When an alarm is initiated from inside the car or from other trapped areas in the well, two-way communication is
provided to the system via pre-defined telephone numbers. In intercom operation, two-way communication is provided
between the speech units.
• All settings of the Arkel ArLine system are made via the web-based ARKEL Cloud system.
• When Arkel ArLine, which is designed to be compatible with all control panels, is used with ARKEL lift control
systems, some information obtained from the lift control system can be tracked online on the ARKEL Cloud website.
The Arkel ArLine system consists of 4 different units:
Arkel ArLine-M Main unit (With built-in GSM/GPRS module and battery)
Arkel ArLine-S-COP Alarm unit without enclosure used in the car operating panel
Arkel ArLine-S-TP Alarm unit with enclosure used in the well (Top of the car/under the car/in the pit)
Arkel ArLine-S-INT Intercom unit used in machine room or lift control panel
3. Package Contents
• Arkel ArLine-M main unit • Arkel ArLine-S-TP well alarm unit
• 1 x Arkel ArLine-M (Built-in battery) • 2 x Arkel ArLine-S-TP (The number of units
• 1 x external antenna (With 3m cable) is 2 in the normal package content. But it may
change according to the user’s request.)
• Arkel ArLine-S-COP car alarm unit
• 1 x Arkel ArLine-S-COP • Arkel ArLine-S-INT intercom unit
• 1 x Arkel ArLine-S-INT (Optional)
Check the contents of the package. Please contact ARKEL or your supplier if any items are missing or faulty.
Arkel ArLine User Manual V1.23
4. Technical Specifications
4.1. Arkel ArLine-M Technical Specifications
Mobile Frequency band Quad-Band 850/900/1800/1900 MHz
RF output power Class 4 for EGSM 850/900 MHz (2W/33dBm max.)
Class 1 for DCS 1800/1900 MHz (1W/30dBm max.)
Technology 2G (GSM), GPRS
SIM card slot Nano SIM (4FF), 12.30 x 8.80 x 0.67 mm
Antenna connection SMA (Female) connector
External antenna GSM, 2-3 dBi, 50 ohm (With 3m cable)
Internal battery Type 12V/1.2Ah maintenance-free dry battery
Connection Built-in, with 2-pin special connector cable
Charging 13,6 VDC, max. 100 Ma (Max. ~ 12 hours)
Supply time (With fully charged battery) Standby state ~ 3 hours, when there is alarm talk ~ 2
Inputs Unit supply hours
100, 1000 16-30V DC
Max. 500mA @ 24V DC
Programmable inputs IN1, IN2, IN3, 8-30V DC, 5 mA, Insulated with
IN4, IN5 double direction optocoupler
Outputs Arkel ArLine-S supply outputs Arkel ArLine-S 10-30V DC, Max. 400 mA
Supply (PWR,
GND)
Supply outputs for programmable inputs INCOM (COM+, 10-30V DC, Max. 200 mA
COM-)
Programmable relay outputs OUT1, OUT2 Max. 2A, Max. 230V AC
Max. 30V DC
Communication Speaker interface (Only compatible with CAR, PIT, EXT, RS-485 serial communication
interface the Arkel ArLine units) FF
Lift control system interface (Only CANBUS CANbus serial communication
compatible with ARKEL products) 4-pin custom connector
User interface 1 button, Information LEDs
General Dimensions 163,20 x 133,23 x 72,20 mm (Width x Length x
Weight Height)
1.3 kg (Including battery)
Operating temperature +5 C° - +40 C°
IP code IP20
Box Metal
Arkel ArLine User Manual V1.23
5. Overview
5.1. General Overview
1. Machine room
2. Inside the car
3. Top of the car
4. Under the car
5. Pit
6. Arkel ArLine-M, main unit
7. Arkel ArLine-S-COP, car speech unit
8. Arkel ArLine-S-TP, top of car speech unit
9. Arkel ArLine-S-TP, pit (or under car) speech unit (* 1)
10. Arkel ArLine-S-INT, machine room/control panel intercom
11. Lift control unit
12. Lift control panel
13. Car top/inspection box
14. Pit box
15. Two-way communication with rescue service/staff
16. ARKEL Cloud remote lift management system
17. Antenna connection (GSM / GPRS)
18. SIM card
19. 24V DC supply (100, 1000)
20. CANbus connection with ARKEL control systems (* 2). Input-
output connections don’t need to be done in parallel.
21. Parallel input and output connections in systems other than
ARKEL.
22. Car speech unit connections.
With 4 wires via car travelling cable.
23. Arkel ArLine-S-COP connection (4 wires).
24. Arkel ArLine-S-COP external alarm button, microphone,
speaker, yellow and green pictogram connections.
25. Arkel ArLine-S-TP top of car connection (4 wires).
26. Arkel ArLine-S-TP under car connection (* 1) (4 wires).
27. Arkel ArLine-S-TP pit connection (* 1) (4 wires).
28. Arkel ArLine-S-INT, machine room/control panel intercom
connection (4 wires).
*1: The speech unit can be placed under the car instead of the pit,
provided that the requirements of the standard EN 81-20 are met.
1 2 3 4 5 6 7
13
14
4
15
8 9 10 11 12
3
2
4
7
3
5
4
7
5
6 8
7 5
9 3 Figure 3 Arkel ArLine-S-COP appearance
5 2
7
8 3
4
6 2
8 11. Arkel ArLine-M (main unit) connection
Figure 4 Arkel ArLine-S-TP 4 12. Dip switch (identification)
appearance 6 13. Yellow pictogram and its LED
14. Green pictogram and its LED
15. Alarm button (yellow)
16. Intercom button (white)
17. Volume adjustment trimpot
18. Microphone
19. Speaker
20. Information LEDs
Arkel ArLine User Manual V1.23
4
6
2
5
4
3
2
5
Figure 5 Arkel ArLine-S-INT appearance
3
6. Installation
6.1. Installation of Arkel ArLine-M
Arkel ArLine-M main unit:
• If the machine room is available, it must be installed in a suitable place within the machine room (Preferably within the
lift control panel or near the panel).
• In hydraulic lifts, it should preferably be installed at the top of the lift shaft (Since the GSM signal level may not be
sufficient in the machine room).
• In the operations without machine room, (Preferably in the lift control panel or near the lift panel), it must be installed
at the top of the shaft.
• Do not install on the car.
The main unit must be installed in an easily accessible place when needed. The button on the unit must be easily accessible and
the LEDs should be visible. Appropriate space should be left for the intervention in the SIM card, antenna and all connectors.
The main unit and the antenna must be installed in the place with the best possible reception. The unit and the antenna can be
placed in a temporary location until the first operation stage. Once the necessary connections and settings have been made and
the GSM communication of the alarm system has been activated, the best location for the antenna can be selected using the GSM
light on the main unit. Whenever you change the position of the antenna, wait for 10 seconds for the GSM signal level to be
detected again. The fact that the GSM light is on means that the alarm system receives enough reception to operate.
A standard mobile phone can also help with the determination of the installation place. For this purpose, the operator of the
mobile phone and the SIM card to be used on the Arkel ArLine-M device must be identical. Place the mobile phone in the area
where you intend to install the product. Make a call and speak. If there is a distortion or interruption in the conversation, select
another location and repeat the same steps.
The following points should be taken into consideration when selecting the installation place:
• The cable length of the antenna is limited to 3m.
• The antenna must be fixed in an upright position on a metal plate that is in horizontal position.
• The antenna must be placed at least 1 meter away from electronic devices to prevent GSM interference.
• Metal cabinets/doors/covers weaken the GSM signal. The antenna must not be placed in a closed metal cabinet.
• For the antenna, parts/walls of the building close to the outside should be preferred.
• If the position of the antenna is changed, the GSM signal level must be checked again.
The location and dimensions of the mounting holes of this unit are shown in the “Dimensions” section of this manual. Install the
unit on a stable surface using suitable screws.
6.2. Installation of Arkel ArLine-S-COP
The Arkel ArLine-S-COP unit is designed to be installed at the rear side of the operating panel inside the car.
For the installation of the products, necessary assembly preparations must have been made in the operating panel.
Arkel ArLine User Manual V1.23
In the “Dimensions” section of this manual, the dimensions and templates required for the installation of this unit are given.
The mechanical installation of the external speaker and microphone will have an impact on the sound quality. The number of the
holes in front of the loudspeaker must be sufficient for the sound to pass. The microphone hole in the operating panel must be
aligned with the hole in front of the microphone to achieve maximum sound quality.
Alarm button, yellow and green pictograms (LEDs) are not included in the product, they are connected externally to the unit.
The operating panel supplier must have made the necessary preparation for the alarm button and pictograms.
Microphone, speaker and related connections are not included. The operating panel supplier must supply these parts. The
properties of these parts are as follows.
The speaker connection is non-directional. The microphone connection is directional. See Figure 15 for the microphone and
speaker connections.
6.3. Installation of Arkel ArLine-S-TP
The Arkel ArLine-S-TP unit is designed to be placed in the well. On the unit, the alarm button, intercom button and yellow-
green pictograms and LEDs are internally present.
It can be installed on top of the car and under the car/in the pit (*) at a suitable location so that the alarm button can be pressed
from any refuge space within 30 cm horizontal distance.
*The speech unit can be installed under the car instead of the pit, provided that the requirements of the EN 81-20 standard are
met. The only way for personnel to be trapped in the pit is that the car closes the exit way of the personnel. In this method, there
will be no need to use additional wires in the pit for the speech unit.
Install the unit on an open and stable surface using suitable screws. If the front or sides of the unit are closed, this may cause
echo problems between the speaker and the microphone.
The location and dimensions of the mounting holes of this unit are shown in the “Dimensions” section of this manual.
6.4. Installation of Arkel ArLine-S-INT
The Arkel ArLine-S-TP unit is designed to be placed in the machine room or on the lift control panel. There is an intercom button
on the unit.
It should be located in the area where the emergency rescue operation is to be carried out (In the machine room or on the lift
control panel).
Install the unit on an open and stable surface, as appropriate. If the front or sides of the unit are closed, this may cause echo
problems between the speaker and the microphone.
The location and dimensions of the mounting holes of this unit are shown in the “Dimensions” section of this manual.
Arkel ArLine User Manual V1.23
7. Connections
7.1. Arkel ArLine-M Connections
GSM antenna connection.
The external GSM antenna that is supplied with the Arkel ArLine-M must be used.
The antenna connector must be fully inserted into the threads in its housing and tightened completely.
The antenna should be placed away from the other electronic devices that may interfere with GSM
communication.
To prevent damage to the product, the GSM antenna must be connected to the connector before the supply.
In the “Installation of Arkel ArLine-M” section, information is given about the location of the antenna and the
signal strength.
100 +24V DC Supply input.
1000 0V
It must be taken from the lift control panel.
The device has an internal battery. It is not necessary to supply via external battery or UPS.
The 100-1000 supply input must be connected even when using the CANbus connection.
24V DC
CANbus serial communication connection.
Filtering inputs do not need to be made in parallel.
It works
24V DC only with the compatible ARKEL control systems. In these systems, the necessary settings for the
Arkel ArLine are explained in the following sections. Car CANbus line must be used.
PWR Arkel ArLine-S supply + Arkel ArLine-S units supply output.
GND Arkel ArLine-S supply - Can be used for cabin units.
PWR Arkel ArLine-S supply + Arkel ArLine-S units supply output.
GND Arkel ArLine-S supply - Can be used for lift shaft and intercom units.
24V DC when there is power, 12V DC when there is no power.
Unit supplies must be connected to PWR and GND so that speech units can continue to operate from the supervised battery
in case of a power failure.
EXT A Arkel ArLine-M unit communication link for the group lifts (Design phase)
B
FF A Communication link with the machine room/control panel intercom unit
B
PIT A Communication with the pit alarm unit
B
CAR A Communication link between the cabin (Cabin interior, top and bottom) and the alarm units
B
The connection between the Arkel ArLine-M supply connection and the Arkel ArLine-S devices is shown below.
Arkel ArLine-M
Arkel ArLine-M
Arkel ArLine-S-COP inside the car Arkel ArLine-S-TP Arkel ArLine-S-INT intercom
Arkel ArLine-S-TP car top Pit
Arkel ArLine-S-TP car bottom
Arkel ArLine-S-INT intercom
Figure 6 Connection between Arkel ArLine units
Arkel ArLine-S-TP
Arkel ArLine-S-COP inside the car Pit
Figure 7 Input connection with Figure 8 + (100) triggered input Figure 9 - (1000) triggered input
internal supply connection connection
OUT1 R1 Programmable relay 1 contact partner (COM)
R1O Programmable relay 1 open contact output (NO)
OUT2 R2 Programmable relay 2 contact partner (COM)
R2O Programmable relay 2 open contact output (NO)
Max. 1A @ 230V AC / 30V DC can be switched.
The relays must not be used to switch the lift safety circuit.
When the relays and inductive loads (Relay, contactor, etc.) are switched, the protection element must be used parallel to the
loads (Reverse diode in DC circuit, varistor or RC in AC circuit).
The status of the relays is indicated by LEDs. The functions that can be assigned to the programmable relay outputs are
described in detail in the section "Output functions".
7.2. Arkel ArLine-S-COP Connections
PWR Supply+ from Arkel ArLine-M PWR terminal
GND Supply- from Arkel ArLine-M GND terminal
A/B Communication line from Arkel ArLine-M CAR A-B terminals
BAT connector is not used, must be left blank.
The PWR-GND power supply via the Arkel ArLine-M has battery backup. 24V DC when there is power, 12V DC when
there is no electricity. For cable connection, the following must be observed in the travelling cable:
• Use 4 cables next to each other.
• The GND (1000) or PE line must be moved from the left and right of the cables if possible.
• These cables must be kept away from high-voltage cables and other cables that may cause electromagnetic
interference (Ex. door unlocking magnets).
See Figure 6 for connection to the Arkel ArLine-M unit.
COM+ + signal common for alarm button input and pictogram outputs
It has the same potential as 100 and PWR terminals.
COM- - signal common for alarm button input and pictogram outputs
It has the same potential as 1000 and GND terminals.
It is limited to a maximum of 200 mA.
Arkel ArLine User Manual V1.23
Figure 10 Dry contact input Figure 11 + (100) triggered input Figure 12 - (1000) triggered input
connection connection connection
In Arcode and ARL-700 control systems, the following method can be used to connect the same contact to both the Arkel
ArLine-S-COP and the control system if the single contact alarm button is used.
Arkel ArLine-S-COP CPC/CPC-T operatingFigure 13 Common connection of the alarm button in Arcode and
panel board
ARL-700 control systems
Yellow
symbol
Green
LED
symbol
LED
Pit alarm
ID: 03
Machine room /
control panel
intercom ID: 04
Trimpot is shown with this symbol: . The trimpot is rotated clockwise to increase the volume and rotate counterclockwise
to reduce the volume.
The loudspeaker sound during the alarm call must be set to comply with the site conditions.
After the alarm button is pressed and the alarm is acknowledged, the acoustic signal given until the voice communication is
established should be set to a sound pressure level between 35 dB (A) and 65 dB (A) at a distance of 1m from the speaker.
Green Turned on Alarm talk is taking place / Intercom talk is taking place.
Arkel ArLine User Manual V1.23
15. Alarm
The stages of alarming via Arkel ArLine-S-COP alarm unit are as follows:
• Press and hold the button connected to the Arkel ArLine-S-COP external alarm button input for 3 seconds.
• It the filtering feature is enabled via ARKEL Cloud, filtering is checked.
• The alarm that fails to pass the filter is removed.
• If the alarm passes the filter, the alarm information is transmitted to the recovery service via ARKEL Cloud and
optionally via SMS. The yellow pictogram LED output is activated.
• The ALARM LED on the Arkel ArLine-M unit is activated.
• The alarm call is started. A beep will be heard until communication with the rescue service is established.
Arkel ArLine User Manual V1.23
• The green pictogram LED is activated when the voice communication is started with the rescue service.
The stages of alarming via the Arkel ArLine-S-TP alarm unit are as follows:
• Press and hold the yellow alarm button on the unit for 3 seconds. Alarm filtering is not applied to the Arkel ArLine-S-
TP units.
• Alarm information is transmitted to the recovery service via ARKEL Cloud and optionally via SMS. The yellow
pictogram LED output is activated.
• The ALARM LED on the Arkel ArLine-M unit is activated.
• The alarm call is started. A beep will be heard until communication with the rescue service is established.
• The green pictogram LED is activated when the voice communication is started with the rescue service
The alarm stages with the programmable input "ALB - Alarm button" on the Arkel ArLine-M unit are as follows:
• The external alarm connected to the Arkel ArLine-M unit is pressed for 3 seconds. Alarm filtering is not applied to the
Arkel ArLine-M unit.
• This method will communicate with the Arkel ArLine-S-COP unit. Therefore, the next steps are the same as the alarm
stages in the Arkel ArLine-S-COP unit.
One of the following methods can be used to terminate the alarm:
• Press and hold the button on the Arkel ArLine-M device for 3 seconds.
• By activating an input to which an "EOA - Alarm termination" function is assigned on the Arkel ArLine-M device.
• Alarm termination tool on the ARKEL Cloud menu.
When an alarm is triggered from an alarm unit, the yellow pictogram LEDs of the other units are activated with the alarm unit
as well. When the speech is started with the rescue service, only the green pictogram LED on the unit that performs the call is
activated.
Communication can only be terminated by the rescue service.
After the communication is terminated, pressing the alarm button again for 3 seconds will repeat the call.
Rescue service can establish voice communication again with the alarm unit if it is desired.
Arkel ArLine User Manual V1.23
No Yes
Is filter
active?
No Yes
Is filtered?
Is this the No
first call?
Yes
No
Answer?
Yes
Answer? Yes
No
Initiating
Yes voice
Answer? Rescue service User
comm.
No
Yes
Answer?
No
Yes
Yes
Answer?
Answer?
No No
16. Intercom
As per EN 81-20 standard;
• No direct voice communication between in the car and emergency rescue place is not possible (Eg. in hydraulic lifts)
• Or where the movement distance of the lift exceeds 30 m,
• A two-way communication system (Intercom) should be installed between the inside the car and the emergency rescue
area (Machine room/control panel).
An Arkel ArLine-S-INT unit added to the Arkel ArLine system can be used to provide the intercom specification described in
EN 81-20. In addition, in the Arkel ArLine system, two-way communication can be made between all speech units.
The ID of the Arkel ArLine-S-INT unit to be used for intercom in the machine room must be set to "04" with the dip-switch (See
section Arkel ArLine-S-TP / Arkel ArLine-S-INT Dip-switch Settings).
The Arkel ArLine-S-TP and Arkel ArLine-S-INT units are equipped with an intercom button, which is indicated by a white
ICOM.
The priority between alarm and intercom work is as follows:
• Intercom communication cannot be performed while the alarm service is active with the rescue service.
• If an alarm is triggered during intercom communication, the intercom is deactivated. Intercom communication is
restored when the alarm communication is switched off.
• Intercom calls can be made when there is an alarm condition that has not yet been terminated, but only when there is
no alarm voice communication with the rescue service.
Intercom operation can occur in two different ways when there is no alarm communication priority:
1) Between outdoor units and car unit:
• When the intercom button on the Arkel ArLine-S-INT or any Arkel ArLine-S-TP unit is held down for less than 3
seconds while no intercom communication is available, communication is initiated between that unit and the in-car
Arkel ArLine-S-COP unit.
• The Arkel ArLine-S-INT / TP units use the push-to-talk and listen method. The Arkel ArLine-S-COP talk is active
unless the Arkel ArLine-S-INT / TP unit is used to talk.
• Communication time is 3 minutes. Each time it is pressed, the intercom button will be set back to 3 minutes. If the
button is pressed 2 times within 1 second, the communication is ended.
2) Between outdoor units:
• When there is no intercom communication, pressing and holding the intercom button on the Arkel ArLine-S-INT or
any Arkel ArLine-S-TP unit for longer than 3 seconds will sound an audible signal on other Arkel ArLine-S-INT / TP
units. Communication is initiated with the intercom button on the unit. Other units cannot initiate communication until
this communication is terminated.
• Communication time is 3 minutes. This time will be set back to 3 minutes each time you press the intercom button
during the call. If the button is pressed twice within 1 second, communication is terminated.
18. Battery
18.1. Battery Test
According to the EN 81-28 standard, the remote alarm system operated by GSM mobile communication should continue to
operate at least 60 minutes (Including 15 minutes of talk) from the emergency electrical power supply in case of power failure.
The status of this emergency electrical power supply and the correct charging of the batteries must be monitored continuously.
The fault status should be reported to the rescue service/personnel automatically and indicated by appropriate means in the lift
installation.
18.2. Battery Test
The Arkel ArLine-M includes one 12V / 1.2Ah maintenance-free dry battery. The charging and automatic testing of the batteries
are performed by the Arkel ArLine-M.
In the Arkel ArLine system, the battery's capacity is tested at regular intervals (1 week). The test can take up to 30 minutes.
During the test, the battery alarm is activated when it is determined that the battery capacity, including 15 minutes of talk, is not
sufficient to allow the alarm system to run for 60 minutes.
It may take up to 12 hours to fully charge an empty battery. The first battery test is performed after 24 hours of operation. The
battery test is not performed during power failure. If a power failure occurs during the battery test, the test is terminated
immediately. The battery alarm is activated without delay if the battery is not plugged in, is connected incorrectly or has a short
circuit.
The following operations are performed during the battery alarm:
• The battery failure is automatically reported to the rescue service/personnel (ARKEL Cloud shows the battery failure,
the battery alarm is sent as a SMS message to the number which is assigned for technical alarms).
• The BAT LED on the Arkel ArLine-M is set to turning on or flashing according to the alarm status.
• The Arkel ArLine-M programmable relay function 'BATF - Battery alarm' is active.
After a successful automatic battery capacity test, the battery alarm is reset and the above-mentioned fault conditions return to
normal.
It is automatically notified to the rescue service/personnel that the battery failure is terminated (ARKEL Cloud is shown to end
battery failure, and it is sent as SMS to the phone number entered for the technical alarm). However, if the battery capacity
problem is not resolved, the same fault condition will repeat in the next automatic battery capacity test.
15 minutes after the power cut, the rescue service/personnel is informed of the power cut. When the battery voltage falls below
a certain level, the battery is disconnected and the Arkel ArLine-M shuts down to prevent deep discharge damage of the battery
in the event of a power failure. Before the switch-off, if there is no active alarm call, the rescue service/personnel is informed
that the device will be switched off. The device will restart automatically when the power is restored.
18.3. Replacing the Battery
The replacement phases of the battery in the Arkel ArLine-M unit are as follows:
• Disconnect the Arkel ArLine-M unit support. Then press and hold the button for 5 seconds to cut off the internal battery
supply and turn off the unit completely.
• Remove the top cover of the unit by removing the 4 screws.
• Remove the battery connector on the Arkel ArLine-M pcb.
• Disconnect the Arkel ArLine-M pcb from the box by removing 4 plastic distensions. The battery will appear under the
pcb.
• Remove the black-red cable connected to the battery.
• The battery is fixed to the top box with a metal plate. Release the battery by unscrewing the plate. Carefully remove the
faulty battery.
• Place the new battery in the same position. Install the fixing plate screws.
• Install the battery cables with paying attention to +/-.
• Secure the Arkel ArLine-M pcb back into the box with the aid of plastic distances.
• Replace the Arkel ArLine-M top cover and replace the screws.
• Connect the supply to the Arkel ArLine-M unit.
‼ Warning: Only 12V / 1.2Ah dry type maintenance-free battery of the same size as the original battery should be used.
‼ Warning: The battery must be replaced every 3 years to guarantee the operating time from the battery.
Arkel ArLine User Manual V1.23
‼ Warning:
Make sure that the faulty battery is disposed of in accordance with local regulations.
‼ Warning: The temperature during use has a significant effect on the service life and capacity of the battery. Ambient
temperatures between 10-25°C and operating temperatures from 20 to 40°C are ideal. Do not store or operate the Arkel
ArLine-M in temperatures above 40°C!
‼ Warning: There is an effect of GSM signal level on the battery operating time. Set the GSM signal level to the highest
possible level.
After the input assignment is made, in which case the function is active is selected:
• If NO is selected, the function will be active when the signal is applied to the input.
• If NC is selected, the function will be active if the signal is interrupted.
For example, if the REV (Maintenance / revision) function is selected and the input type is set to NC, it will be informed that the
lift is in revision when there is no signal at the relevant input.
If no input is to be used, the "NONE - Undefined" function must be assigned to the input.
Arkel ArLine User Manual V1.23
• Assignments of output functions are made under the 'Outputs' section. The functions that can be assigned to the
programmable relay outputs are described in detail in the section ‘13 Outputs (Relay) Functions’.
If no output (Relay) is to be used, the output must be assigned to "NONE - Undefined" function.
• The 'Status' section displays the current information about the device.
Status Description
Firmware Version Shows the firmware version of Arkel ArLine-M unit.
Hardware Version Shows the hardware version of Arkel ArLine-M unit.
IO Status Shows the status of the input and output signals online:
• The active signal is indicated by a green color.
• The signal in the passive state is shown in red.
CANbus Connection Indicates the connection status of the Arkel ArLine-M unit to the CANbus line.
Battery Voltage Indicates the voltage of the battery in the Arkel ArLine-M device.
Supply Voltage Shows the Arkel ArLine-M input supply voltage.
Number Shows the SIM card number inserted in the Arkel ArLine-M device.
Signal Strength The signal strength indicators are as follows:
Perfect Best signal strength
Good Strong signal strength. Suitable for device usage.
Medium Medium signal strength. The device is sufficient for use but interruptions may occur.
Weak Weak signal strength. The device is not available. Replace the antenna installation
location.
No signal There is no connection. The device is not available. Check the antenna connection
and change the installation location.
Terminate the Alarm This button can be used for the remote alarm termination of the rescue service/personnel in case
of false alarm. Alarm termination in real alarm situations; after the rescue of the
passenger/personnel stuck in the related lift, must be performed by the personnel performing the
recovery (With the help of this button or with the alarm termination methods on the Arkel ArLine
device).
The units connected to the lift can be displayed live via the visual section under the status section. The following example
illustrates:
• With the Arkel ArLine-M device; It is shown that the inside the car, car top and machine room units are connected.
• Bottom and pit alarm units are not connected.
22. Inspection and testing before the lift are taken into service (EN 81-28:2018, 6.3)
22.1. Alarm
1. Press the alarm button in the car for more than 30 seconds. The alarm starts.
2. Check the response of the rescue service/personnel.
22.2. End of Alarm
1. After performing the alarm test in item 21.1, terminate the alarm in one of the following ways:
2. Press and hold the button on the Arkel ArLine-M device for 3 seconds.
3. By activating an input to which the "EOA - Alarm end" function is assigned on the Arkel ArLine-M device or,
4. With the alarm termination tool on ARKEL Cloud menu.
5. Check that the yellow pictogram LED is turned off.
22.3. Emergency Electric Power Supply
1. Disconnect the 24V supply (100-1000) of the Arkel ArLine-M device. The device will continue to operate from the
battery.
2. Check the alarm in accordance with 21.1.
3. Reconnect the 24V supply of the Arkel ArLine-M device.
4. Disconnect the battery supply.
5. Open the Arkel ArLine-M box and remove the battery connector on the pcb.
6. Check for a battery failure:
7. Check that the BAT LED on the Arkel ArLine-M is lit.
8. Check the ARKEL Cloud screen for a battery alarm.
9. Check that a battery alarm SMS message is sent to the phone number entered for the technical alarm.
10. If used, check that the Arkel ArLine-M programmable relay function 'BATF - Battery alarm' is active.
11. Reconnect the battery supply.
Reconnect the battery connector on the Arkel ArLine-M pcb and close the box.
22.4. Information in the lift car
During the test in article 21.1, verify the yellow-green pictograms, audible signals and voice communication.
22.5. Communication
1 Press the alarm button for 3 seconds when the car and landing doors are not fully open in the lift.
2 The alarm starts.
3 Check answer.
4 Ask the rescue service/staff to turn off the voice communication.
5 Restart the alarm and check the response before terminating the alarm.
Arkel ArLine User Manual V1.23
23. Dimensions
23.1. Arkel ArLine-M