SIMATIC WinCC Unified V17 TechSlides 2021 06 09 EN
SIMATIC WinCC Unified V17 TechSlides 2021 06 09 EN
SIMATIC WinCC Unified V17 TechSlides 2021 06 09 EN
Technical information
Unrestricted © Siemens 2021 www.siemens.com/wincc-unified
WinCC Unified V17
Change Log
WinCC Unified technical slides cover the overall functionality of the WinCC Unified system.
Please note the WinCC Unified Architecture slides that show typical configurations and use cases in detail !
Preconditions
Overview
Tools
Links
Overview
Tools
Links
Operating Systems
Configuration Engineering Runtime
(64-bit)
• Windows 10 Home Version 1909
Windows 10 Home • Windows 10 Home Version 2004
• Windows 10 Home Version 2009/20H2
Windows Server
• Windows Server 2016 Standard (Full Installation)
(for Unified PC RT with
• Windows Server 2019 Standard (Full Installation)
more than 5 Clients)
Operating
System (Client) Recommended Browser
Microsoft Windows • Google Chrome (Preferred) recommended 90.0 (at least version 77 or higher)
• Microsoft Edge Chromium recommended 90 (at least version 88 or higher)
• Mozilla Firefox recommended 88.0 (at least version 78 or higher)
• Mozilla Firefox ESR recommended 78.10 (at least version 78.6 or higher)
Reporting (Excel)
Local installation of MS Excel (32- or 64-Bit) as new as possible in accordance to operation system
Online access to Excel (Online Office 365)
Virtualization
VMware vSphere Hypervisor (ESXi) 6.7 (or higher)
VMware Workstation 12.5.5 or VMware Workstation 15.5.0 (or higher)
VMware Player 12.5.5 or VMware Player 15.5.0 (or higher)
Microsoft Hyper-V Server 2019
Overview
Tools
Links
Platform
Unified Comfort Panels, PC
Common engineering
Software
SIMATIC WinCC Unified
(TIA Portal) V17
Unified Unified
Core functionality Description Comfort Panels PC Runtime
User Interface Scalable for all devices
Unified Unified
Basic Options Description Comfort Panels PC Runtime
Unified Unified
SCADA Options Description Comfort Panels PC Runtime
Database Option Performant, large-scale and long-term managed logging
SSR
Plant Intelligence Unified Unified
Options1 Description Comfort Panels PC Runtime
Coordination and synchronization of machines/
Line Coordination2
units via recipe-controlled procedures
Flexible arrangement of automatic steps within
Sequence2
the production process including manual interaction
1 Technological hierarchy is mandatory 3 Edge App Performance Insight for Unified Comfort Panels SIOS (109780761)
2 No broad market for V17 (Sales special release by Product Management)
Please note: separate technical slides for PI Options are available at (MPM) after release.
SSR = Sales Special Release
Available Available (limited) In work Not available
Unified Unified
TIA Portal Options Description Comfort Panels PC Runtime
User Management
Central user management
Component
Comprehensive simulation of the controller functionality
PLCSIM (Advanced)
including interaction with virtual plant and machine models
Coordinated working within a team. Centrally track changes
Multiuser Engineering
with user comments and versions
TIA Portal
Boost the flexibility through engineering in your private cloud
Cloud Connector
Teamcenter Gateway Plant-wide storage of TIA Portal projects in Teamcenter
SIMATIC Visualization Standardized HMI visualizations efficiently
Architect SiVArc through automatic generation
ProDiag Efficient diagnosis of process errors to reduce downtimes
Energy Suite and
Energy transparency in production
S7-EE Monitor
PM-MAINT Maintenance planning tool designed for the use in preventive maintenance
PM-OPEN HOST/S Flexible communications solutions between the automation level and SAP ERP 3
PM-OPEN
View analytical and quality reports via MindSphere 3
MINDCONNECT
Please note the separate release info of PM-AddOns provided by CoC Mannheim in SIOS.
1Release of the PM-Agent to connect the PM-AddOns to WinCC Unified PC Runtime. Controls are
Available Available (limited) In work Not available not integrated in RT but run as separate program (either in parallel or using a separate PC station).
Functional comparison
internal use only
The Knowledge Base also includes a technical
comparison of Unified Comfort Panels and
Unified PC Runtime
Version
V16 V17
Overview
Tools
Links
19” Panel
Improvement “Snaplines”
• works by adjusting the size of objects
• preview snapline by insert new screen
objects
Improvement “Multi-Selection”
change the common attributes of multiple objects
Extension of Drag&Drop
works now on switch and trend control,
Drag & Drop e.g. select multiple tags and insert to trend control
(multiple tags)
Unrestricted © Siemens 2021
Page 23 SIMATIC WinCC Unified V17
WinCC Unified V17 – User Interface
Engineering efficiency
Transfer Format
Transfer format copying formatting
Object handling
• Align objects (left, right, top, bottom)
Object Alignment
• set select objects to the same height and/or width
• Distribute objects evenly vertically/horizontally
Evenly distribute
vertically
Layer handling
Move objects one layer up or down
Select a color
*only for control with active header
Unrestricted © Siemens 2021
Page 26 SIMATIC WinCC Unified V17
WinCC Unified V17 - Engineering efficiency
Extended Animation dialog
Copy & Paste conditions of animation dialog for further screen objects
Multi selection
to move several screen items to another layer
Default
New flat styles
▪ Adapted look and feel e.g. for bar
▪ Responsive behavior depends of the item size
Bright
Touch area
Homogenous engineering
• Consistent visualizations
• Independent from technology
e.g., Unified Comfort Panel or web-browser
Versioning
• Unified Faceplates are handled like simple type
versions
• Instanced can be rewired to a higher or lower version
as well as to other types
• Different versions of one type can be used in parallel
Conversion from Common Data: Unified V16 Faceplates will be moved and
converted to TIA Portal Library automaticly. Add PLC UDTs as type to the library in • Definition of a „default version“ to be used
V16 to reuse them on the interface,
Faceplates in Libraries
create, delete and version faceplate types
➢ Identical interfaces
of icon and operation window
➢ Popup is created at runtime.
Must not be placed in a screen.
Snippet for the call
➢ Faceplate interface is passed at runtime
Detail faceplate
Resource list
• Extension for graphic list
Choose a version
Parent Property
use Faceplate.Parent.YourProperty to have
access to the detail properties from the faceplate
container in Runtime. UseCase e.g. positions or
visibility
Connected Interface to
Faceplate
Multilanguage support
Export all Library texts add or delete a Runtime language does not
change the version of the library type
Global handling
Export/Import all library text at the same time
Unified Unified
Unified
Comfort Panels Comfort Panels
PC Runtime
7”- 12” 15”-22”
No. of Trends 600 600 1000
No. Of trends
20 20 60
per trend view
Trend areas
2 5 5
per trend view
No, of (Bit-/Analog)
9.000 / 300 9.000 / 300 200.000 / 10.000
alarms
No. of alarms
2048
per alarm view
• Consistent design, • Integrated SVG library with • Define standards for visuali-
usability and functionality static and dynamic SVGs zation and operation of plant
• Innovated Controls for for many industries assets e.g., related to PLC
efficient operation • High quality graphics, fully UDTs
scalable for all resolutions • Efficient engineering and
• Customized graphics upon reusability of faceplate types
demand (e.g., motor object and motor
operation)
• High performance in com-
bination with structured
data types
Choose free a
replacement character
Possibility to have
dynamic DB numbers Multiplex array index of symbolic Array tags
Array of Standard data types
and
Array of PLC UDT
Trusted certificates for communication partner Time savings when integrating different
systems via standardized interface
Add User
OPC UA Client with Security policies and User & password authentication
Unrestricted © Siemens 2021
Page 66 SIMATIC WinCC Unified V17
WinCC Unified V17
OPC UA Server for alarm and condition
Acknowledge alarms
OPC UA direct on the OPC UA
client
de-DE
Immediate notification of process states, warnings or Alarm control for efficient handling e.g., filter,
critical alarms for quick reactions and shorter downtimes.
sort, acknowledge, manually or via scripting
Configurable colors
(background and text)
HMI alarms
• Bit alarms
Program alarm ProDIAG alarm • Analog alarms
• Install SIMATIC WinCC Unified Add-in from DVD2 • Install SIMATIC WinCC Unified Add-in from DVD2
• Share Folder (read only) using Explorer • Insert Report Add-in to Excel
…\WinCCUnifiedReporting\Excelmanifest (WinCCUnifiedReportingExcelAddIn.xml)
located in …\WinCCUnifiedReporting\Excelmanifest\
• add folder to Trusted Add-in catalog (Excel Options -Trust Center)
• Insert Report Add-in to Excel (Excelmanifest)
X O O O =
Report Template
XO=
Report
Report
OOO
Report
Report
OOO
Report
Report
=
Execute report template
• Manual or automated generation of reports
Report
OOO Report
OOO =
X OOO
Report Template Editor
Unified RT
WinCC Unified ES
MS Excel 2 • Engineer WinCC Unified Screen with Report Control
Create report template • Download Project to
WinCC Unified PC Station
or HMI Unified Comfort Panel
Import Report Select Import Report Select
Template Online data Template Online data
1 UCP: Libre Office is used to generate pdf 2 Local installation or Online Office 365
WinCC Unified PC Unified Comfort Panel1 1Unified Comfort Panel: online/offline configuration only via WinCC Unified Client!
Office PC
(no RT connection)
Unified
Unified
Comfort Panel 1 2
PC
1 2 Use external storage media to transfer offline configuration file or Report Templates
online/offline configuration only via WinCC Unified Client !
Select “Alarm”
Frequency of your
Alarms
Global settings
• For Email distribution
• Export & Import of RT configuration to setup a new station
Overview executed
reports
By default is it not
possible to use Gmail
https://myaccount.google.com/lesssecureapps
2. Enter email
address
1. Add a contact
8.
7.Add
Add aa contact
contact
• Scheduler:
Script execution time-based and event triggered (on tag value change / alarm state change)
C# API
ODK
Create custom solutions based on an
extensive C#/C++ runtime object model –
Open Developer Kit (ODK)
3rd
WinCC
Party
Unified
apps
Language independent
C#/C++ Programming languages
e.g.: C#, C++, JavaScript, PowerShell, …
Online and Logging Tags, Archives, Alarms, Read/Write access to data Online Tags,
Users, Technological Hierarchy plant objects of WinCC Unified data Alarms (read only)
Individual solutions for a specialized visualization use cases. Custom-specific functionalities, e.g.,
Programming skills are required for implementation, regarding according to industry specific requirements
performance, robustness and maintenance
Enable search
Search field
Activate
“Breadcrumb”
Go Back
1. Navigation Type
Dynamic
Dynamic navigation reduces visible tree size by showing only one hierarchy level at a time
in runtime
Configure any node as the root node. Visualize only the part of the tree of your interest.
New snippet
• Object oriented approach based • Plant status information • One model in engineering
on standardized plant assets regarding e.g., alarm or and in runtime
• Efficient Engineering due to performance of sub nodes • Reduced effort for configuration
standardized plant objects • Fast overview of the plant and maintenance
status at a glance
V16 V17
Login (UMC)
Login (UMC)
Central User Management
please check WinCC Unified architecture slides
for typical configurations
Unified Comfort Panel WinCC Unified Unified PC
Overview
Tools
Links
Databased
Changeover to databased logging (optional)
possible due to identical logging structures
Logging Tags
Planned
Power Tags
Central logging as overall plant
archiving solution (optional)
Universal logging functionality for machine-level requirements
regarding handling of archive data e.g., copy/paste log files
Unrestricted © Siemens 2021
Page 120 SIMATIC WinCC Unified V17
SIMATIC WinCC Unified – Logging Tags
Licensing
Unified PC Systems
• File-based Logging up to 5,000 Logging Tags
• Licenses for Logging Tags:
100; 500; 1,000; 5,000 (countable)
0
File based
Comparison, Value, Relative Value, Swinging Door Smoothing Comparison, Value, Relative Value, Swinging Door
Yes (e.g. day, week) Compression archives Yes (e.g. day, week, month, year)
Yes (copy©log
Unrestricted file manually)
Siemens 2021 Backup Yes (automated backup)
Page 122 SIMATIC WinCC Unified V17
WinCC Unified V17 – Logging –
Background
• WinCC Unified uses an event-driven logging concept which is essentially different to former polling concept.
PLC communication also uses Event-Driven concept.
o With event-driven approach, only the changes are logged, but at reading data from the log the accurate information can be "restored".
• With "On change" data changes are logged very precisely (up to 100ns accuracy), logging is as precise as the data acquisition on driver level.
• Unified logs are kind of time-series database
• "On change“ configuration of logging system ensures higher throughput
and is thus better for both the performance and database size
• Using "Cyclic" logging means a considerable overhead which reduces performance
• If a real cyclic logging data is required e.g. for evaluation, it is better to restore (fill-up) intermediate data on demand on Client / User side and
not store these in the log database.
Log A
For best performance and optimal footprint
- Data the set of fixed configuration data is separated
Log Segments from the dynamic, continuous values.
Log B
- Data
Log Segments
Same structure for file based logging(SQLite)
and Microsoft SQL logging
Aggregation methods
• On request – event-triggered archiving e.g. archiving current process value after a production step is finished
Smoothing modes
• No smoothing – All values are logged
• Comparing values – Time interval – value changes within interval will not be logged
• Value – Limit value (hysteresis) – log only if distance to last value is exceeded
• Relative value – Deviation (in %) – log only if deviation to last value is exceeded
• Swinging Door – Compression of values according to defined rate of change
(choose between deviation of minimal or maximal time)
• Easy to handle for • Data acquisition up to 100 ms • Choose your logging concept
machine-level solutions and aggregation modes (e.g.,
• High compression for minimum month, year) upon on demand
• Consistent evaluation footprint (e.g., Swinging Door)
using trends • Grow with your requirements
from no logging at all up to
5,000 logging tags file-based
Precondition – UDTs are already Add new Parameter set type Assign UDT as data type to Parameter
created and available in the library within project tree set type to derive structure from UDT
Add structure tag to exchange Para- Configure properties e.g., Display Use Control tags for automatic ex-
1 meter sets between HMI and PLC 2 name, Unit of measurement 2 change between HMI and PLC (optional)
Efficient engineering
• No duplicated
engineering by linking
existing screens of other
devices
44.78 94.78 4.78
46.23 A 66.23 B 6.23 C
Flexible operation
• Common usability
A A A for local and collaboration
screens
B B B
C
44.78
46.23 C
94.78
66.23 C
4.78
6.23 • Show insights to other
machines or lines
• Full integration of screens
Unrestricted © Siemens 2021 – no extra login required
Page 134 SIMATIC WinCC Unified V17
WinCC Unified – Collaboration
News V17
Role Fct_Right 2 x
Role Fct_Right 2 x It is mandatory to match function rights (spelling)
“Admin” “Operator”
Fct_Right 3 x Fct_Right 3
User1 Fct_Right 4 x
User2 Fct_Right 4
Role
Change Value x
Role x
If Local user management (UMAC) is used,
Fct_Right 2 x Fct_Right 2
“Admin”
Fct_Right 3 x
“Operator”
Fct_Right 3
identical user names can be configured with
User1 Fct_Right 4 x
User1 Fct_Right 4 different roles and different function rights
A A Recommendation
B B Make sure to use the same roles and function
44.78 44.78 rights for same users
C 46.23
C 46.23
Central User Management (UMC)
is recommended for cross-project collaboration
WinCC Unified Remote Control of Machine A
Machine A via Collaboration
System ID, Collaboration name and IP address / Hostname must be unique in collaboration network
Runtime settings need to be adjusted on each collaboration device
Pending alarms
Name of partner station
Logged alarms
System alarm and system information is generated if connection cannot be established to partner device
The time on WINCCUNIFIED and WINCCUNIFIED2 differs approximately 468 sec. ->> Time synchronization!
Certification file error: initialization failed ->> Something with the certificate went wrong
PC
Client "Operate"
enables remote operation according to
assigned user role
Clients "Monitor"
enables remote operation in view-only mode
Every WinCC Unified PC Runtime system includes: Asynchronous access of numerous users
- The local visualization Client (installed or via browser)
(simultaneous access is licensed)
- ONE “Operate” Client
- ONE “Monitor” Client Windows 10 Server is mandatory
The maximum number of clients can be extended (optional). for more than 5 Clients !
PC
“User management”
for user administration
“Certificate Authority”
Install HTTPS certificates to the local client
(tile visible if certificates are prepared on the RT
station)
Unrestricted © Siemens 2021
Page 144 SIMATIC WinCC Unified V17
WinCC Unified V17 – PC Systems
WinCC Unified Clients “Operate” & “Monitor”
PC
WinCC Unified PC Runtime
offering Clients for remote Monitoring or Operation
Please note
There are separate licenses for Client Operate and
Secure remote access using Web standards Client Monitor (independent from each other)
Manual Certificate Manager SIOS (109779117)
PC
PC
User dependent configuration
• New right and role “HMI Monitor only”
• Standard visualization is possible
At Runtime, the Monitor Client is marked via orange frame around base screen
HMI Monitor Client
• HMI Monitor client can be combined with
system- and user defined runtime-rights
PC
Disabled operation on alarms
• acknowledge active alarms
• Reset active alarms
• Comment of logged alarms
• Clear archive of logged alarms
• Configure enable and disable alarm
PC
Disabled operation on alarms
• acknowledge active alarms
• Reset active alarms
• Comment of logged alarms
• Clear archive of logged alarms (via system
function)
• Configure enable and disable alarm
System Function
PC
• Flexible remote access for any number
of users (concurrent access)
150
• Grow on demand increase number of Clients
by 1, 3, 10, 30, 100 (countable)
Confirmation type
▪ None
▪ Acknowledgement (requires user authentication)
Own textlist
• Name of the Audit Entry String, HMI tag, Screen Object
• Category String, HMI tag, Screen Object
• Operation type modify (0), delete (1), new (2)
• Old Value Integer, Double, Bool, String, Color, HMI Tag, Screen Obj
• New value Integer, Double, Bool, String, Color, HMI Tag, Screen Obj
• Confirmation type None (0), Acknowledgement (1), Comment (2)
• Reason optional
OnChange function
Use Snippet to create Audit .CSV file to get a Auit Trail preview !
Please note: Audit Trails incl. Detection of manipulation“ must be done via Unified Reporting.
Add
2. Add
absolute
absolutetimes
times
e.g.
e.g.
last
last
24h24h
3.Add
Addproperties
propertiesfor
foraa
legend if needed
5.5.
Select
Select
the
the
Audit
Audit
source
source
4. Add data source items
Systemfuntion
InsertElectronicRecord Remote, with required
comment
No reset or
Reset Audit trails
Record changes
of process data
(manual, automated, Script)
Overview
Links
Databased
Data archive according to industrial requirements
or legal instructions e.g., for 10 years
Logging Tags
Planned
Power Tags
Central logging as overall plant
archiving solution (optional)
Powerful SCADA-level archiving to store and
analyze a huge number of tags over long periods
+
0 Database option
Databased (nur PC Systeme)
(PC systems only)
For logging of more than 5,000 Tags
• Choose your logging concept • Data acquisition up to 100ms • Grow on demand to a central,
and aggregation modes (e.g. reliable, plant wide data archive
month, year) upon on demand. • Flexible aggregation and
smoothing (e.g., Swinging Door) • One point of data for data
• Grow with your requirements to of data for for minimum footprint evaluation and integration
archive according to industry
specific or legal requirements • Efficient long-term logging as
base for founded analysis
(trends, statistics)
Overview
Tools
Links
Additional Properties
• Additional settings for Runtime start with
auto scale, reset options, settings (debug, certificates,..)
Restoring segments
In Runtime you have the option of restoring segments
of logs for which a backup was created (backup setting as
defined in Unified Logging).
Restored data can be visualized e.g. via trend view
WinCC Unified
Certificate Manager at
the Unified RT PC
Use the WinCC Unified Certificate Manager SIOS (109779117) to create and transfer certificates.
C:\Program Files\Siemens\Automation\WinCCUnified\WebConfigurator
An OPC client tries The connection is refused Open SIMATIC Decide to trust the Certificate is trusted and
to connect to WinCC and the certificate is Runtime Manager certificate, the certificate connection can be
Unified Runtime stored in untrusted and go to Settings -> is moved to trusted established
station certificates Certificates certificates
Note: in the background the certificates will be placed to the certificate store of the Runtime station
C:\ProgramData\SCADAProjects\certstore
Unrestricted © Siemens 2021
Page 185 SIMATIC WinCC Unified V17
SIMATIC WinCC Unified – Tools
Tag Simulator - simulate internal and process tags
Overview
Tools
Links
Find all the supporting materials for the WinCC Unified System at a glance
https://support.industry.siemens.com/cs/ww/en/view/109777887
Direct access to the most important technical information and solutions for Visualization
for newcomers and experienced WinCC Unified users.
TIA Selection Tool for quick, easy and smart configuration: TIA Selection Tool
Unrestricted © Siemens 2021
Page 192 SIMATIC WinCC Unified V17
SIMATIC WinCC Unified V17
www.siemens.com.vn
www.facebook.com/Siemens.Vietnam
Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may
not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested
performance features are binding only when they are expressly agreed upon in the concluded contract.
All product designations, product names, etc. may contain trademarks or other rights of Siemens AG, its affiliated companies or third parties.
Their unauthorized use may infringe the rights of the respective owner.
siemens.com/wincc-unified-system