Check Up For Operation of A LIAG / MAN Marine Gen Set
Check Up For Operation of A LIAG / MAN Marine Gen Set
Check Up For Operation of A LIAG / MAN Marine Gen Set
Please Note: This is a summery of the most important matters for operating LIAG Marine Generating Sets. Due to your special
wishes and to latest technological development LIAG can not guarantee for completeness of this document and reserves the
right to modify the content of this document without notification. Please read your complete final documentation for more
detailed information about operation of your LIAG-Generating Set.
Table of content
Revision mark.......................................................................................................................................... 2
General information ................................................................................................................................. 3
Description of Generating Set ................................................................................................................. 3
Instructions to avoid errors and damages: .............................................................................................. 4
Important Addresses and Phone numbers.............................................................................................. 8
Amendment 1: Filling standard for MAN Diesel Engines ........................................................................ 9
Amendment 2: Lifting Instruction........................................................................................................... 10
Amendment 3: Conversion Table.......................................................................................................... 11
Amendment 4: Check List ..................................................................................................................... 12
Revision mark
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 2 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014
General information
• This documentation instruction should be kept in a safe place for future use. It does not take all the
design details and variants nor all the possible chance occurrences and events which might happen
during installation, operation and maintenance into account.
• We retain all copyright for all LIAG-Documents . It is intended only for personal use by the owner of
the diesel generator set and / or for operation or installation of the LIAG-Generating Set.
• The documentation contains technical instructions and drawings which may not, as a whole or in
part, be reproduced, distributed or used in any unauthorized way for competitive purposes or
passed on to others.
• LIAG / MAN Marine Diesel Generating Sets produce electricity for several applications depending
on the kind of generating set. A generator, with the help of a diesel engine, produces power to be
used on your ship as an auxiliary for daily use, in harbour mode or as an emergency generating set.
• The LIAG / MAN Generating Set is build by Lindenberg-Anlagen GmbH in Rösrath, Germany. The
main component, the engine, is made by MAN. All spare parts and equipment are available from
Lindenberg-Anlagen GmbH - Spare Parts Department ([email protected]). Please
use the spare part numbers which can be found in this documentation for an easy and fast
procedure.
• For technical help or in case of any damages please contact our Service Department
([email protected]). Please keep the intervals of maintenances work and follow
the descriptions by manufacturer to prevent unnecessary damages.
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 3 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014
Instructions to avoid errors and damages:
(Most instructions are also summarized in the checklist in Amendment no. 1)
Important instructions
• It may be used only the manufacturer released and specified service and maintenance materials.
(For example filter, lube oil...)
• No warranty can be granted for damages, when the damage is based on working without
consideration of the regulations and / or the operating instructions. If any information cannot be
found in the documentation, please contact LIAG.
Transport
• Keep the instructions for transport and moving. LIAG gives you detailed instruction but you also
need to inform about national and local rules of transportation.
• Only use the bolts, designed for transport to lift up the gen set as shown in this example. Do not use
bolts directly on the engine or on the generator.
When lifting Generating Set always keep in mind that the lifting device
may brake.
Do not stand under Generating Set
Storage
• The generating set needs to be stored dry and safe. This includes no direct influence by weather or
seawater. The generating set must not dangle, incline nor be easily moveable.
• In case the generator set is stored for over 12 month the Engine needs to be conserved according
to MAN rule M3069-4 / C3 and arranged and confirmed by LIAG, otherwise warranty cannot be
granted.
Engines
• The LIAG / MAN commissioning certificate for generating sets has to be filled out for every engine.
It has to be sent back to Lindenberg-Anlagen GmbH - Service dept. The commissioning report can
be found in our Working / Final Documentation Chapter1 Notice / Documents.
• Please note that MAN can refuse warranty, if the commissioning certificate is not filled out
and sent back.
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 4 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014
The running generating set makes a noise level above 80 dB (A).
Everybody in the Engine room or near running generating set must
use hearing protection!!
Generator
• Check that all connection, cable glance and settings have been made as stated in operation /
installation and maintenance instructions by manufacturer to be found in working / final
documentation in Chapter 3 Alternator.
Coupling
• Check with a lamp if the coupling has any obvious damages before starting the engine for the first
time. Please repeat this check before each start of the generating set.
• The requirements for the cooling water as hardness, chloride, sulphates and PH-value have to be
considered and the cooling water has to be filled up with the prescribed additives according to the
regulations of the MAN. These can be checked on the internet page by MAN
http://www.man-engines.com/en/Ship_motors/Ship_motors.jsp. → Approved service products.
The additives have to be filled in, independently of the outside temperature. The antifreeze and
corrosion protection prevents cavitations of the cooling water pump.
• In the tropics there are also additives according MAN standard 249.
• Chemicals which are permitted for high power engines (for example MAN B&W) can not be used by
MAN engines.
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 5 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014
• For auxiliary engines the cooling water pressure has to be controlled.
• Just use MAN approved Lubrication Oils. See: Fuels, Lubricants and Coolants for MAN Diesel
Engines, please check the approved products on the internet page by MAN
http://www.man-engines.com/en/Ship_motors/Ship_motors.jsp → Approved service products
The Lube oil is strongly flame able. Do not smoke or light fire near
the engine or when refilling lube oil!
Fuel System
• The ship lateral installation, of fuel oil pre filter with water traps, has to be considered.
• Crude oil is not allowed to be used for MAN High Speed engines.
The fuel oil is strongly flame able. Do not smoke or light fire near
the engine or the fuel oil tank!
• The line has to be checked to be free of work materials. (steel, papers, tags)
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 6 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014
Exhaust System gets extremely hot. Do not touch or contact with
flame able material while or after engine runs!
The distance between in- and outflow holes must be long enough, so
that no short circuit develops!
Check screws if screws are tight and sealed. As well as air pressure
hoses are not damaged.
• In the ship lateral air supply line, has to be planned before the starter an air cleaner with automatic
water trap.
• Before using, each starter must have 18Æ30 bar starting pressure. (Depending on type of air
starter the starting pressure may vary.)
• The ambient temperature limit needs to be kept (depending on classification 45° C or 50° C) in the
engine room. Watch out for heating through exhaust material.
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 7 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014
Important Addresses and Phone numbers
Webpage
• www.lindenberg-anlagen.de
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 8 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014
Amendment 1: Filling standard for MAN Diesel Engines
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 9 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014
Amendment 2: Lifting Instruction
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 10 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014
Amendment 3: Conversion Table
Pressure
Bar Pascal
1 bar 100000 Pa
Temperature
Length
Inch Millimetre
1’’ (in) 25,4 mm
Energy
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 11 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014
Amendment 4: Check List
Please check following list before first start of the generating sets
Managing director: Postal address: Delivery address: Tel.: 0049 (0) 2204 48103 - 0 Page 12 / 12
Dipl.-Ing.(FH) Olaf Berghoff Lindenberg-Anlagen GmbH Lindenberg-Anlagen GmbH Fax.: 0049 (0) 2204 48103 - 109
Postfach 5164 Hoffnungsthaler Strasse 417 email: [email protected] Rev.: 02
Trade register: HRB 45514 51486 Overrath 51491 Overrath Internet: www.lindenberg-anlagen.de Date: 17.03.2011
DE 121 961 663 Document-No.:000 014