Advantech EKI-1242BNMS - Bacnet To Modbus Gateway
Advantech EKI-1242BNMS - Bacnet To Modbus Gateway
Advantech EKI-1242BNMS - Bacnet To Modbus Gateway
Features
Supports dual power input for power redundancy
Seamless integrate Modbus RTU/TCP and BACnet IP/MSTP communication
Modbus Client mode supports 64 connections
Mounts on DIN-rail and Wall mount
Designed for protocol extensibility and adaption
Built-in real time diagnostic to increase highly efficiency of device
management
'I' models support a wide operating temperature
Introduction
The EKI-1242BNMS Industrial Fieldbus gateway provides seamless communication between Fieldbus and Industrial Ethernet and supports different protocol devices integrating new and
existing Modbus RTU/TCP devices with BACnet IP/MSTP networks. EKI-1242BNMS is a simple and cost-effective way to bring the advantage of fast I/O data transfers between devices.
Specifications
Ethernet Communication General
Protocols BACnet IP, Modbus TCP LED Indicators System: Power, System Status, Protocol status
LAN: Speed, Link/Active, Error
Number of Ports 4
Reboot Trigger Built-in WDT (watchdog timer)
Speed 10/100 Mbps, Auto MDI/MDIX
MicroSD Card Configuration backup and restore
Connector 8-pin RJ45
Protection Built-in 1.5 KV magnetic isolation Mechanics
Dimensions (W x H x D) 42 x 140 x 95 mm (1.66" x 5.52" x 3.75")
Serial Communications Enclosure Metal with solid mounting hardware
Port Type RS-232/422/485, software selectable Mounting DIN-rail, Wall
No. of Ports 2 Weight 0.497 Kg
Protocol BACnet MSTP, Modbus RTU
Port Connector DB9 male Power Requirements
Data Bits 5, 6, 7, 8 Power Input 24 VAC/VDC, redundant dual inputs
Stop Bits 1, 1.5, 2 Power Connector Terminal block
Parity None, Odd, Even, Space, Mark Power Consumption 7.2W
Flow Control XON/XOFF, RTS/CTS Environment
Baud Rate 50 bps ~ 921.6 kbps Operating Temperature -10 ~ 60 °C (14 ~ 140 °F)
Serial Signals RS-232: TxD, RxD, CTS, RTS, DCD, RI, GND ' I' models: -40 ~ 75 °C (-40 ~ 167 °F)
RS-422: TxD+, TxD-, RxD+, RxD-, GND Storage Temperature -40 ~ 85 °C (-40 ~ 185 °F)
RS-485: Data+, Data-, GND Operating Humidity 10 ~ 95% RH
Software Regulatory Approvals
Modbus RTU/TCP EMC CE, FCC Part 15 Subpart B (Class A)
Mode Client
Functions Support 1, 2, 3, 4, 5, 6, 15, 16
Max. Number of Connections 64 connections
BACnet IP/MSTP
Class BACnet IP/Slave, BACnet MSTP/Master
Support objects AI, AO, BI, BO
Max object instance 200 objects each type
[0.457]
11.60
15
[0.591]
[0.808]
20.53
104 [4.094]
95 [3.740]
9.80 [0.386]
140 [5.512]
[1.852]
47.05
[1.888]
47.95
95 [3.740]
Ordering Information
EKI-1242BNMS Modbus RTU/TCP to BACnet Fieldbus Gateway
EKI-1242IBNMS Modbus RTU/TCP to BACnet Fieldbus Gateway with
wide operating temperature