Energy Saving Switch MANUAL

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

IMPORTANT SAFETY INSTRUCTIONS

1. Read these instructions WARNING


2. Keep these instructions. Turn the power supply to the instrument OFF before wiring or
3. Heed all warnings. checking.Working or touching the terminal with the power switched
4. Follow all instructions.
5. Do not place product referred in this manual long-term in the extreme environment ON may result in an Electric Shock which could cause severe injury
6. Install in accordance with the manufacturer’s instructions. or death.
7. Use accessories only specified by the manufacturer.
8. Refer all servicing to the qualified service personnel.Servicing is required when the product has been INSTALL:
damaged in any way. 1. Uninstall front frame and card container
2. Wire and check as following drawing
INTRODUCTION 3. Fill it in the junction box placed in the wall in advance.
Congratulations on your selection of Energy saving switch product. 4. Screw down to the junction box
It offers a energy saving solution for the rooms of hotel, apartment and any other place it suitable. 5. Recover front frame and card container
When guest is in room, insert card in and the power comes.But when he is not in room power is not
supplied.Another function is keep the keycard for guest to find it easy.
Before using the instrument, be sure to carefully read through the instructions contained in this manual. Live line out
Please keep all information for future reference.
Live line in Zero line
SPECIFICATIONS
Working voltage AC 180V~250V(110V required customize)
Working current <100 mA Reder
fix clip
Electric current MAX 30A
Card container
Working Tempreature 32 F~158 F(0 C~70 C) fix clip
Working Humidity 15~85%RH
Color white
Screw hole to
Size 86×86×48mm(29mm bury in wall) junction box
Delay 15sec AC 180V-250V
30A
LED light Insert keycard here

Front frame
fix clip
NOTICE:
1. User prepare junction box(standard 86x86cm)
Card container 2. Unit don’t include wires and screws of junction box
3. Live line out terminal is connected with the room load

Energy saving switch user’s manual


-model S2508/2308/2208 series
S2508/2308/2208 series www.xeeder.us
INITIALIZE:
1. Read Authorized card to switch
(IC card switch requires insert card)
Function form of S2508/S2308/S2208 series

green light flash for succeed S2508series S2308series S2208series


red light flash for failed work by insert...

name card/credit card/ NO NO NO


paper
2. Read Time card to switch
(IC card switch requires insert card)
Yes if same card type
in-correct guest card NO NO IC/M1
green light flash for succeed
red light flash for failed
correct room guest
Yes if same card type
card but already NO YES IC/M1
expired

Yes if same card type


3. Read Room setting card to switch proper guest card YES YES IC/M1
(IC card switch requires insert card)

Safe class A B C
green light flash for succeed
red light flash for failed

Time card and Setting card comes from REQUIRED REQUIRED NO

Initialize ISO 14443A/ ISO 14443A&B&15693


S2508series S2308series S2208series support card type ISO 14443A/
/IC(SLE4442)
IC(SLE4442) IC(SLE4442)
1. read Authorized card REQUIRED REQUIRED NO

2. read Time card REQUIRED NO NO

3. read Setting card REQUIRED REQUIRED NO