C ATA LO G
Time relays
CT-C, CT-S, CT-D
—
Available in three different ranges
to cover every application, CT
range time relays are used to
provide reliable timing functions
worldwide. They have proven their
excellent functionality in daily use
under the toughest conditions.
—
Time relays
Table of contents
11 CT-C range
23 CT-S range
44 CT-D range
55 Timing functions
62 Index
4 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 5
—
Time relays for industrial
applications
Table of contents
6 Offer overview
7 Type selection
9 Applications
11 CT-C range
23 CT-S range
6 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
Time relays for industrial applications
Offer overview
—
Time relays for industrial applications
Type selection
B OFF-delay CT-MFC, CT-MKC, CT-AHC CT-MVS, CT-MFS, CT-MBS CT-APS, CT-AHS, CT-ARS
CT-ARC
AB ON- and OFF-delay CT-MVS, CT-MXS, CT-MFS,
CT-MBS
CA Impulse-ON CT-MFC, CT-MKC CT-VWC CT-MVS, CT-MFS, CT-MBS,
CT-WBS
CB Impulse-OFF CT-MFC, CT-MKC, CT-MVS, CT-MFS, CT-MBS
CT-ARC
CE Impulse-ON and OFF CT-MXS
DA Flasher starting with ON CT-MFC, CT-MKC CT-EBC CT-MFS, CT-MBS, CT-WBS
DB Flasher staring with OFF CT-MFC, CT-MKC CT-EBC CT-MFS, CT-MBS, CT-WBS
DE Flasher starting with ON CT-MVS
or OFF
ED Pulse generator starting CT-TGC CT-MXS
with ON or OFF
H Pulse former CT-MFC, CT-MKC CT-MVS, CT-MFS, CT-MBS
F Star-delta change-over CT-SDC, CT-SAC CT-SDS
A detailed explanation of the different timing functions can be found in the chapter “Timing functions”.
—
Synonyms
Used expression Alternative expression(s)
1 c/o contact SPDT
2 c/o contacts DPDT
voltage-related wet / non-floating
volt-free dry / floating
8 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 9
—
Time relays for industrial applications
Applications
ABB offers a wide selection of time relays – from economic to high-end – to suit
every application for businesses worldwide. ABB time relays provide simple, reliable
and economical control solutions in all types of panel. They are typically used in
industrial applications and OEM equipment, providing time-delayed switching to
start a motor, control a load or manage a process.
Remote control of time delays with a Cyclic switching of machinery, for Lighting control, for example the
remote potentiometer. example the weekly startup of a fan to delayed switching of multiple rows of
prevent them sticking or the flushing lamps in production facilities or green-
of pipes to keep them clear. houses.
Time controlled start up or shut down Alarm triggering in case of fault Star-delta motor starting to reduce
of machinery equipment, for example detection, for example to allow the starting current with changeover delay
the delayed switch off of conveyor flashing of a lamp in industrial applica- to prevent interphase short-circuits.
belts or the successive shut down of a tions or rolling stock.
plant.
—
CT-C range
Table of contents
13 Operating controls
14 Selection table
15 Ordering details
16 Technical data
20 Technical diagrams
12 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
CT-C range
Benefits and advantages
The CT-C range combines lower cost with higher value and performance by offering
essential functions in a 17.5 mm housing, freeing up room in any control cabinet. The
range includes 11 devices, offering both single and multifunctional types, with a time
range from 0.05 seconds to 100 hours. Equipped with wide voltage ranges, CT-C
time relays allow for use across a huge variety of applications worldwide.
With a width of just 17.5 mm, the CT-C range is 22% smaller than standard industrial housings for
time relays. Its reduced overall footprint saves space in control cabinets. For more flexibility both
Space savings 1 c/o and 2 c/o output versions are offered in the compact housing.
The CT-C range is an economical range that combines lower cost with higher value and perfor-
Cost effective mance. It suits basic applications where a time relay is needed, while offering improved function-
solution ality in each device.
By combining more functions into each device, the CT-C range makes it possible to reduce stock
by up to 75% compared to other ranges. All devices in the CT-C range offer a wide supply voltage
range as well as a wide time setting range from 0.05 seconds to 100 hours. This significantly
reduces order code variance, making the range more compact with just 15 order codes covering
Optimized logistics every requirement.
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 13
—
CT-C range
Operating controls
Width 17.5 mm
With a width of just 17.5mm, CT-C
time relays are ideal for installa-
tions with limited space.
Connection terminals
Wide terminal spacing makes
wiring connections easier:
2 x 1.5 mm2 (2 x 16 AWG) with wire Control input to start timing
end ferrules or 2 x 2.5 mm2 (2 x 14
AWG) without ferrules.
H Pulse former
14 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
CT-C range
Selection table
1SVR508020R0000
1SVR508150R0000
1SVR508100R0000
1SVR508130R0000
1SVR508160R0000
1SVR508120R0000
1SVR508110R0000
1SVR508010R1300
1SVR508020R1100
1SVR508180R0100
1SVR508100R0100
1SVR508160R0100
1SVR508210R0100
1SVR508110R0100
1SVR508211R0100
Order number
CT-VWC.12
CT-MKC.31
CT-MFC.21
CT-MFC.12
CT-AHC.22
CT-AHC.12
CT-SDC.22
CT-TGC.22
CT-ERC.22
CT-ARC.12
CT-EBC.12
CT-SAC.22
CT-PAC.22
CT-TGC.12
CT-ERC.12
Type
Timing function
ON-delay A J J J J J
OFF-delay with aux. voltage B J J J J J
OFF-delay w/o aux. voltage B J
Impulse-ON CA J J J J
Impulse-OFF with aux. voltage CB J J J
Impulse-OFF w/o aux. voltage CB J
Flasher starting with ON DA J J J J
Flasher starting with OFF DB J J J J
Pulse generator starting with ON or OFF ED J J
Pulse former H J J J
Star-delta change-over F J J
Alternating w/o time delay J
Features
Control input, voltage-related triggering J J J J J J J
Time range
0.05 s - 100 h J J J J J J J J J 2 2
0.05 s - 10 min J J J
Supply voltage
12-240 V AC/DC J J
24-48 V DC J J J J J J J J J J J J J
24-240 V AC J J J J J J J J J J J J J
Output
Solid state J
c/o contact 1 2 1 1 2 1 2 1 1 1 2
n/o contact 2 2 2
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 15
—
CT-C range
Ordering details
Description
The CT-C range combines lower cost with higher value and performance in a slim 17.5 mm-wide
housing. All relays have a wide time setting range from 0.05 seconds up to 100 hours. Combined
with a wide voltage range they are the perfect choice for applications worldwide.
2CDC251030V0018
—
Ordering details
Timing Rated control Time Control Output Type Order code Weight
CT-MFC.12
function supply ranges input (1 pc)
voltage
kg (lb)
Multi 1)
12-240 V 7 (0.05 s - M Solid CT-MKC.31 1SVR508010R1300 0.060
AC/DC 100 h) state (0.132)
Multi1) 24-240 V AC M 1 c/o CT-MFC.12 1SVR508020R0000 0.060
24-48 V DC (0.132)
Multi1) 12-240 V M 2 c/o CT-MFC.21 1SVR508020R1100 0.065
AC/DC (0.143)
2CDC251029V0018
—
CT-C range
Technical data
—
CT-C range
Technical data
—
CT-C range
Technical data
—
CT-C range
Technical diagrams
—
Example of application - Star-delta changeover
L1 L2 L3
L1 F3
95 1 3 5
F2 -F1
96 2 4 6
S1 21
0
22
S2 13 53
I K2
14 54 1 3 5 1 3 5 1 3 5
-K2 2 4 6
-K3 2 4 6
-K1 2 4 6
17 17 13 13
K1T K2 K1
18 28 14 14
22 22 1 5 4 97 95
K3 K1 -F2
21 21 3 2 6
A1 A1 A1 A1 -M1
K1T K1 K3 K2
2CDC253009F0012
2CDC252128F0006
A2 A2 A2 A2 W1 W2
N V1 M V2
U1 3~ U2
Y i N
—
Connection diagrams
2CDC252115F0b06
2CDC252113F0b06
2CDC252177F0b05
A2 16 18 26 28 A2 16 18 A2 16 18 26 28 A2 16 18
18 16 Y1/B1 18 16
18 16 A2 18 16 A2
28 26 A2 28 26 A2
15-16/18 1st c/o contact A1-Y1/B1 Control input 15-16/18 1st c/o contact 15-16/18 1st c/o contact
25-26/28 2nd c/o contact 15-16/18 1st c/o contact 25-26/28 2nd c/o contact
20 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
CT-C range
Technical diagrams
—
Connection diagrams
2CDC252180F0B05
2CDC252116F0b06
2CDC252179F0b05
2CDC252117F0b06
A2 16 18 26 28 A2 16 18 A2 16 18 A2 16 18
18 16 Y1/B1
18 16 A2 18 16 A2 18 16 A2
28 26 A2
2CDC 252160F0b06
2CDC252118F0b06
2CDC252119F0b06
A2 16 18 26 28 A2 16 18 A2 18 28 A2 18 28
18 16 Y1/B1
18 16 A2 28 18 A2 28 18 A2
28 26 A2
A1 Y1/B1
2CDC 252 160 F0b06_n
A1 15
A1 A2
A1 15 A1 Y1/B1 17
A1 13
2CDC 252160F0b06_N
A2 16 18 A2 18
A2 14 24
18 16 A2 18 17 A2
24 14 13
A1-A2 Supply: A1-A2 Supply:
12-240 V AC/DC 12-240 V AC/DC
A1-A2 Supply: 15-16/18 1st c/o contact 15-16/18 1st c/o contact
24-48 V DC or
24-240 V AC
13-14 1st n/o contact
(relay R1)
13-24 2nd n/o contact
(relay R2)
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 21
—
CT-C range
Technical diagrams
—
Load limit curves
resistive load
resistive load
2CDC252013F0218
2CDC252150F0206
2CDC252013F0218
—
Derating factor F —
for inductive AC load Contact lifetime
1.0
2CDC 252 124 F0206
Derating factor F
0.9
0.8
0.7 250 V
resistive load
2CDC252148F0206
2CDC252124F0206
0.6
0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
cos ϕ
Switching current [A]
— —
Wiring notes for devices with Dimensional drawings
control input in mm and inches
L(+)
2CDC 252 102 F0b06
80 3.15“
45 1.77“
70 2.76“
45 1.77“
A1 Y1/B1
2CDC252130F0006
2CDC252131F0b06
2CDC252102F0006
2CDC
A2
CT-C devices with 1 c/o contact CT-C devices with 2 c/o contacts
or 2 n/o contacts
N(-)
22 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 23
—
CT-S range
Table of contents
28 Selection table
29 Ordering details -
multifunctional devices
30 Ordering details -
singlefunctional devices
32 Technical data
36 Technical diagrams
24 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
CT-S range
Benefits and advantages
The CT-S range allows simple tool free mounting and demounting on the DIN rail. Thanks to
the easy connect and the double-chamber cage connection technology simplified wiring with
Improve installation or without wire end ferrules is no problem. Both allow simple and easy installation, even in
efficiency case of different cable diameters.
The CT-S range’s extended features make it especially suited for harsh environments. The housing
material has the highest UL fire protection classification. All functions are available with Push-in
terminals, making operations in environments with high vibrations possible without retightening.
Additionally, the CT-S range offers devices with an extended temperature range, running operations
Reliable in harsh in temperatures as low as -40 °C effortlessly. Specific types are tested according to the latest rail
conditions industry standards, making them a perfect solution for rolling stock and other rail applications
Every device in the CT-S range is designed to provide a wide supply voltage range, making global
differences irrelevant. Additionally, the CT-S range meets a broad range of standards and require-
ments. Together with ABB’s global support and sales network, using CT-S gives customers the
Global availability confidence of worldwide sourcing – no matter where they build, install or operate their equipment.
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 25
—
CT-S range
Operating controls
Remote potentiometer
connection possible
—
CT-S range
Benefits and advantages
—
01 Tool-free mounting
of wires
—
02 Wiring of double-cage
chamber connection
terminals with screw driver
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 27
—
CT-S range
Made for extreme conditions
Selected products of the CT-S range comply to the latest rail standards like EN50155.
Designed for harsh environments, not only are standard screw type terminals offered
– push-in terminals with excellent vibration resistance are also available. Perfect for
use in rolling stock.
Conductor car
• In the event of the press switch not switching off the
auxiliary release pumps of the breaking system, a delayed
switch off is triggered by the time relays
• While switching between hold-on and start-up coil on the
main switch, a time relay can prolong the pulse
• The reliable and safe functionality of the compressor is
essential for trains
Passenger cars
• The control of air flow and interior lighting is controlled by
time relays. A time interval can trigger a delayed start and fin-
ish for the air circulation as well as turning on or off the lights
inside the cabin
• The advanced CT-S range of time relays from ABB is designed
to fulfill all necessary requirements for rail applications
—
Electronic relays for railway solutions brochure
For more information about time relays in rolling stock applications visit:
new.abb.com/low-voltage/products/electronicrelays
—
CT-S range
Selection table
CT-WBS.22l 1SVR70040R3300
CT-MVS.21l 1SVR70020R0200
CT-MVS.22l 1SVR70020R3300
CT-MXS.22l 1SVR70030R3300
1SVR70010R0200
1SVR70180R0300
CT-MBS.22l 1SVR70010R3200
1SVR70100R0300
1SVR70180R3300
1SVR70100R3300
CT-MVS.12l 1SVR70020R3100
1SVR70120R3300
CT-MVS.23l 1SVR70021R2300
1SVR70210R3300
1SVR70180R3100
1SVR70100R3100
1SVR70110R3300
1SVR70120R3100
1SVR70211R2300
Order number*
CT-AHS.22l
CT-MFS.21l
CT-SDS.23l
CT-SDS.22l
CT-APS.22l
CT-ERS.22l
CT-APS.12l
CT-ARS.21l
CT-ERS.12l
CT-APS.21l
CT-ERS.21l
CT-ARS.11l
Type*
—
Timing function
Order number and type
All devices are available ON-delay A J J J J J J J J J J
either with push-in termi-
nals (P-type) or double-
ON-delay, accumulative A(+) J J J J J
chamber cage connection OFF-delay w. aux. voltage B J J J J J J J J J J
terminals (S-type). OFF-delay w. aux. voltage, accumulative B J
OFF-delay w/o aux. voltage B J J
Terminal Type Order
number
ON- and OFF-delay, symmetrical AB J J J J J J
Push-in l=P =4
ON- and OFF-delay, symmetrical, accumulative AB J
Screw l=S =3 ON- and OFF-delay, asymmetrical AB J
ON/OFF function G J J J J J J J J
Impulse-ON CA J J J J J J J
Impulse-ON, accumulative CA J
Impulse-OFF w. aux. voltage CB J J J J J J
Impulse-OFF w. aux. voltage, accumulative CB J
Impulse-ON and OFF CE J
Fixed impulse with adjustable time delay AC J
Adjustable impulse with fixed time delay AC J
Flasher starting with ON DA J J J
Flasher with reset, starting with ON DA J J
Flasher starting with OFF DB J J J
Flasher with reset, starting with OFF DB J J
Flasher starting with ON or OFF DE J J J J
Pulse generator starting with ON or OFF ED J
Single pulse generator EC J
Pulse former H J J J J J J
Star-delta change-over F J J
Star-delta change-over with impulse FC J J J J J
Features
Control input, voltage-related triggering J J J J J J J J
Control input, volt-free triggering 2 1 J
Remote potentiometer connection J 2 J J
2nd c/o contact selectable as instantaneous contact J J J
Extended temperature range (-40...+60 °C) J J J J
Time range
0.05 s - 10 min J J J J
0.05 s - 300 h J J J J 2 J J J J J J J J J J
Supply voltage
24-48 V DC J J J J J J J J J J J
24-240 V AC J J J J J J J J J J J
24-240 V AC/DC J J J J J J
380-440 V AC J J
Output
c/o contact 2 2 2 1 2 2 2 2 2 2 1 2 2 1 2 1 2
n/o contact 2 2
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 29
—
CT-S range
Ordering details - multifunctional devices
Description
The high-performance CT-S range is ideally suited for universal use and is available with two
different connection technologies:
• Double-chamber cage connection terminals (Screw terminals)
• Easy Connect Technology (Push-in terminals)
2CDC 251 024 V0011
—
Ordering details
CT-MVS.21P
Timing Rated control Time Control Output Type Order code Weight
function 5) supply ranges input (1 pc)
voltage
kg (lb)
Multi 24- 240 10 (0.05 s - M 2 c/o CT-MVS.21S 1) 2) 3) 1SVR730020R0200 0.148
V AC/DC 300 h) (0.326)
CT-MVS.21P 1) 2) 3) 1SVR740020R0200 0.136
(0.30)
2CDC 251 023 V0011
1)
Extended temperature range -40 °C
2)
Remote potentiometer connection
3)
2nd c/o contact selectable as instantaneous contact
4)
2 remote potentiometer connections
5)
See selection table on previous page
S: Screw connection
P: Push-in / easy connect
30 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
CT-S range
Ordering details - singlefunctional devices
—
Ordering details
Timing Rated control Time Control Output Type Order code Weight
function supply ranges input (1 pc)
voltage
2CDC 251 030 V0011
kg (lb)
ON-delay 24-240 V AC/ 10 (0.05 s - 2 c/o CT-ERS.21S1) 1SVR730100R0300 0.13
DC - 300 h) (0.287)
CT-ERS.21P1) 1SVR740100R0300 0.121
CT-ERS.21P (0.267)
24-48 V DC, CT-ERS.22S 1SVR730100R3300 0.121
24-240 V AC (0.267)
CT-ERS.22P 1SVR740100R3300 0.113
(0.249)
24-48 V DC, - 1 c/o CT-ERS.12S 1SVR730100R3100 0.106
24-240 V AC (0.234)
CT-ERS.12P 1SVR740100R3100 0.101
2CDC 251 033 V0011
(0.222)
OFF- 24-240 V AC/ 10 (0.05 s M 2 c/o CT-APS.21S1) 1SVR730180R0300 0.146
delay DC - 300 h) (0.322)
CT-APS.21P1) 1SVR740180R0300 0.125
CT-AHS.22P (0.276)
24-48 V DC, CT-APS.22S 1SVR730180R3300 0.138
24-240 V AC (0.304)
CT-APS.22P 1SVR740180R3300 0.127
(0.28)
M 1 c/o CT-APS.12S 1SVR730180R3100 0.109
(0.24)
CT-APS.12P 1SVR740180R3100 0.103
(0.227)
2CDC 251 040 V0011
1)
Extended temperature range -40 °C
2)
Without auxiliary voltage
3)
50 ms transition time
S: Screw connection
P: Push-in / easy connect
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 31
—
CT-S range
Ordering details - Accessories
The CT-S range offers the possibility of using accessories such as a remote potentiometer to
adjust the time delay or a sealable, transparent cover to protect against unauthorized changes
of time and threshold values.
1SFC 151 139 V0001
—
MT-x50B
Remote potentiometer
50 kΩ ±20 % - 0.2 Ω, degree of protection IP66
pieces g / oz
Plastic, black KA1-8029 1SFA616920R8029 1
Metal, chrome KA1-8030 1SFA616920R8030 1
—
Accessories for CT-S
(0.009)
Marker label for devices w/o DIP MAR.01 1SVR366017R0100 10 0.001
switches (0.002)
Sealable transparent cover Marker label for devices with DIP MAR.12 1SVR730006R0000 10 0.001
for CT-S in new housing switches (0.002)
32 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
CT-S range
Technical data
CT-S
Input circuit - Supply circuit
Rated control supply voltage Us CT-xxx.x1 24-240 V AC/DC
CT-xxx.x2 24-48 V DC, 24-240 V AC
CT-xxx.x3 380-440 V AC
Rated control supply voltage US tolerance -15...+10 %
Rated frequency DC or 50/60 Hz
Frequency range AC 47-63 Hz
Typical power consumption max. 16 VA
Power failure buffering time 24 V DC min. 15 ms
230/400 V AC min. 20 ms
Release voltage > 10 % of the minimum rated control supply voltage Us
Minimum energizing time 100 ms (CT-ARS)
Formatting time 1) 5 min (CT-ARS)
Input circuit - Control circuit
Kind of triggering CT-MVS, CT-MXS, CT-APS voltage-related triggering
Control input, Control function A1-Y1/B1 start timing external
Parallel load / polarized yes / no
Maximum cable length to the control input 50 m - 100 pF/m
Minimum control pulse length 20 ms
Control voltage potential see rated control supply voltage
Current consumption of the control input 24 V DC 1.2 mA
230 V AC 8 mA
400 V AC 6 mA
Kind of triggering CT-MFS, CT-MBS, CT-AHS volt-free triggering
Control input, Control function Y1-Z2 start timing external
X1-Z2 pause timing / accumulative functions (CT-MFS)
Maximum switching current in the control circuit 1 mA
Maximum cable length to the control input 50 m - 100 pF/m
Minimum control pulse length 20 ms
No-load voltage at the control inputs 10-40 V DC
Remote potentiometer
Remote potentiometer connections, resistance value Z1-Z2 50 kΩ (CT-MFS, CT-MBS, CT-MVS.21, CT-MXS)
Z3-Z2 50 kΩ (CT-MXS)
Maximum cable length to remote potentiometer 2 x 25 m, shielded with 100 pF/m
Shield connection Z2
Timing circuit
Time ranges 10 time ranges 0.05 s - 300 h 1.) 0.05-1 s 2.) 0.15-3 s 3.) 0.5-10 s 4.) 1.5-30 s 5.) 5-100 s
6.) 15-300 s 7.) 1.5-30 min 8.) 15-300 min 9.) 1.5-30 h
10.) 15-300 h
7 time ranges 0.05 s - 10 min (CT-SDS, CT- 1.) 0.05-1 s 2.) 0.15-3 s 3.) 0.5-10 s
ARS) 4.) 1.5-30 s 5.) 5-100 s 6.) 15-300 s 7.) 0.5-10 min
Recovery time 24-240 V AC/DC < 50 ms
24-48 V DC, 24-240 V AC < 80 ms
380-440 V AC < 60 ms
Accuracy within the rated control supply voltage tolerance it < 0.004 % / V
Accuracy within the temperature range it < 0.03 % / °C
Repeat accuracy (constant parameters) < ±0.2 %
Setting accuracy of time delay ±6 % of full-scale value
Star-delta transition time fixed 50 ms (CT-SDS, CT-MBS, CT-MFS, CT-MVS.2x)
Star-delta transition time tolerance ±2 ms
1)
Prior to first commisioning and after a six-month stop in operation
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 33
—
CT-S range
Technical data
—
CT-S range
Technical data
Environmental data
Ambient temperature ranges operation / storage -25...+60 °C / -40...+85 °C,
-40...+60 °C / -40...+85 °C for CT-MVS.21, CT-MFS.21, CT-ERS.21,
CT-APS.21
Relative humidity range 25 % to 85 %
Vibration, sinusoidal (IEC/EN 60068-2-6) functioning 40 m/s2, 10-58/60-150 Hz
resistance 60 m/s2, 10-58/60-150 Hz, 20 cycles
Vibration, seismic (IEC/EN 60068-3-3) functioning 20 m/s2
Shock, half-sine (IEC/EN 60068-2-27) functioning 150 m/s2, 11 ms, 3 shocks/direction
resistance 300 m/s2 , 11 ms, 3 shocks/direction
Isolation data CT-S with 1 c/o CT-S with 2 c/o
Rated insulation voltage Ui input circuit / output circuit 500 V
output circuit 1 / output circuit 2 not available 300 V
Rated impulse withstand voltage Uimp between all isolated circuits 4 kV; 1.2/50 µs
except devices CT-xxx.23:
input / output: 6 kV; 1.2/50 µs
output 1 / output 2: 4 kV; 1.2/50 µs
Power-frequency withstand voltage between all isolated circuits 2.0 kV; 50 Hz; 60 s
(test voltage)
Basic insulation (IEC/EN 60664-1) input circuit / output circuit 500 V
Protective separation (IEC/EN 60664-1) input circuit / output circuit 250 V
Pollution degree (IEC/EN 60664-1) 3
Overvoltage category (IEC/EN 60664-1) III
Standards / Directives
Standards IEC/EN 61812-1
Low Voltage Directive 2014/35/EU
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU
Electromagnetic compatibility
Interference immunity to IEC/EN 61000-6-2, IEC/EN 61000-6-1
electrostatic discharge IEC/EN 61000-4-2 Level 3, 6 kV / 8 kV
radiated, radio-frequency IEC/EN 61000-4-3 Level 3, 10 V/m (1 GHz) 3 V/m (2 GHz) 1 V/m (2.7 GHz)
electromagnetic field
electrical fast transient / burst IEC/EN 61000-4-4 Level 3, 2 kV / 5 kHz
surge IEC/EN 61000-4-5 Level 4, 2 kV A1-A2
conducted disturbances, induced IEC/EN 61000-4-6 Level 3, 10 V
by radio-frequency fields
harmonics and interharmonics IEC/EN 61000-4-13 Class 3
Interference emission IEC/EN 61000-6-3, IEC/EN 61000-6-4
high-frequency radiated IEC/CISPR 22, EN 55022 Class B
high-frequency conducted IEC/CISPR 22, EN 55022 Class B
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 35
—
CT-S range
Technical diagrams
—
DIP switch configuration CT-MXS.22x
4 3 2 1
ON
OFF Pulse generator, starting with ON or OFF
ON
OFF Single pulse generator, starting with OFF
ON
OFF Asymmetrical ON- and OFF-delay
ON
OFF Impulse-ON and Impulse-OFF
ON
OFF No function
ON
OFF ON/OFF function
—
Example of application - Star-delta changeover
L1 L2 L3
L1 F3
1 3 5
95 -F1
F2 2 4 6
96
S1 21
0
22
S2 13 53
I K2 1 3 5 1 3 5 1 3 5
14 54
-K2 2 4 6
-K3 2 4 6
-K1 2 4 6
17 17 13 13
K1T K2 K1
18 28 14 14
2CDC 253 009 F0012
1 5 4 97 95
22 22
K3 K1 -F2 98 96
2CDC 252 128 F0b06
21 21 3 2 6
A1 A1 A1 A1
-M1
K1T K1 K3 K2
2CDC252128F0006
2CDC253009F0012
A2 A2 A2 A2 W1 W2
N V1 M V2
U1 3~ U2
Y i N
—
CT-S range
Technical diagrams
—
Connection diagrams
2CDC252004F0b06
2CDC252003F0b06
2CDC252002F0b06
2CDC252003F0b06
A2 16 18 26 28 A2 16 18 26 28 A2 16 18 26 28 A2 16 18
22 24
28 24 26 22 28 26 28 26
18 16 A2 18 16 A2 18 16 A2 18 16 A2
2CDC252008F0b06
2CDC252005F0b06
2CDC252007F0b06
A2 16 18 26 28 A2 16 18 26 28 A2 16 18 26 28 A2 16 18 26 28
22 24 22 24
28 26 Y1/B1 28 24 26 22 Y1 28 24 26 22 Y1 28 26
18 16 A2 18 16 A2 18 16 A2 18 16 A2
A1-A2 Supply: 24-48 V DC or A1-A2 Supply: A1-A2 Supply: 24-48 V DC or A1-A2 Supply: 24-48 V DC or
24-240 V AC 24-240 V AC/DC 24-240 V AC 24-240 V AC
A1-Y1/B1 Control input 15-16/18 1st c/o contact 15-16/18 1st c/o contact 15-16/18 1st c/o contact
15-16/18 1st c/o contact 25-26/28 2nd c/o contact 25-26/28 2nd c/o contact 25-26/28 2nd c/o contact
25-26/28 2nd c/o contact 21-22/24 2nd c/o contact as 21-22/24 2nd c/o contact as
Z1-Z2 Remote potentiometer instantaneous contact instantaneous contact
connection Y1-Z2 Control input Y1-Z2 Control input
Z3-Z2 Remote potentiometer X1-Z2 Control input Z1-Z2 Remote potentiometer
connection Z1-Z2 Remote connection
potentiometer
connection
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 37
—
CT-S range
Technical diagrams
—
Connection diagrams
A1 15 25 A1 15 25 A1 15
2CDC 252 009 F0b06
2CDC252009F0b06
2CDC252002F0b06
2CDC252010F0b06
A2 16 18 26 28 A2 16 18 26 28 A2 16 18
28 26 28 26
18 16 A2 18 16 A2 18 16 A2
15-16/18 1st c/o contact 15-16/18 1st c/o contact 15-16/18 1st c/o contact
25-26/28 2nd c/o contact 25-26/28 2nd c/o contact
A1 15 25 A1 15 25 A1 15 Y1/B1 A1 15 25
2CDC 252 011 F0b06
2CDC252013F0b06
2CDC252011F0b06
2CDC252011F0b06
A2 16 18 26 28 A2 16 18 26 28 A2 16 18 A2 16 18 26 28
28 26 28 26 28 26 Y1
18 16 A2 18 16 A2 18 16 A2 18 16 A2
A1-A2 Supply: A1-A2 Supply: 24-48 V DC or A1-A2 Supply: 24-48 V DC or A1-A2 Supply: 24-48 V DC or
24-240 V AC/DC 24-240 V AC 24-240 V AC 24-240 V AC
A1-Y1/B1 Control input A1-Y1/B1 Control input A1-Y1/B1 Control input Y1-Z2 Control input
15-16/18 1st c/o contact 15-16/18 1st c/o contact 15-16/18 1st c/o contact 15-16/18 1st c/o contact
25-26/28 2nd c/o contact 25-26/28 2nd c/o contact 25-26/28 2nd c/o contact
B CT-ARS.11 B CT-ARS.21
F CT-SDS.22 F CT-SDS.23
A1 15 A1 15 25
2CDC 252 014 F0b06
A1 17
2CDC 252 016 F0b06
A1 17
2CDC 252 016 F0b06
A1 15 A1 15 25 A1 17 A1 17
2CDC252014F0b06
2CDC252015F0b06
2CDC252016F0b06
2CDC252016F0b06
A2 16 18 A2 16 18 26 28 A2 18 28 A2 18 28
28 26
18 16 A2 18 16 A2 18 28 A2 18 28 A2
A1-A2 Supply: A1-A2 Supply: A1-A2 Supply: 24-48 V DC or A1-A2 Supply: 380-440 V AC
24-240 V AC/DC 24-240 V AC/DC 24-240 V AC 17-18 1st n/o contact
15-16/18 1st c/o contact 15-16/18 1st c/o contact 17-18 1st n/o contact 17-28 2nd n/o contact
25-26/28 2nd c/o contact 17-28 2nd n/o contact
38 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
CT-S range
Technical diagrams
—
Load limit curves
100 100
80 80
60 60
252 194 F0205
50 50
40 40
2CDC2CDC252194F0205
2CDC252193F0205
30 30
20 20
10 10
0.1 0.2 0.5 1 2 4 6 10 0,1 0,2 0,5 1 2 4 6 10
I A I A
— —
Derating factor F for inductive AC load Contact lifetime
1.0
0.9
0.8
0.7 250 V
resistive load
0.6
2CDC252124F0206
2CDC252148F0206
0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
cos ϕ
Switching current [A]
—
Wiring notes
L(+) L(+) +V
2CDC 252 105 F0b06
2CDC 252 101 F0b06
A1 X1 Y1 A1 Y1
2CDC252105F0b06
2CDC252101F0b06
A2 Z2 A2 Z2
N(-) N(-) 0V
—
CT-S range
Technical diagrams
—
Wiring notes
2CDC252104F0b06
2CDC252103F0b06
2CDC252102F0b06
A2 A2 A2 Z2
The control input Y1/B1 is triggered with electric potential against A2. It is
possible to use the control supply voltage from terminal A1 or any other voltage
within the rated control supply voltage range.
—
Dimensional drawings
in mm and inches
113.4 4.47”
105.9 4.17” 22.5 0.89”
85.6 3.37”
2CDC252009F0011
2CDC25008F0010
103.7 4.08”
8 0.32”
22.5 0.89” 4.8 0.19”
68 2.68”
0.315”
3A11
8
2CDC252186F0005
2CDC252010F0011
20
front to back 0.787”
110.5 4.31”
COV.11 sealable transparent cover MAR.01 marker label
40 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 41
—
Time relays for building
applications
Table of contents
43 Applications
46 Selection table
47 Ordering details
48 Technical data
52 Technical diagrams
42 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 43
—
Time relays for building applications
Applications
The CT-D range is designed in a modular housing, making it well suited for building
and residential applications. In just 12 order codes the CT-D range covers all the main
timing functions needed for building automation, safely and reliably.
A typical application for timers is Air conditioning systems, heaters and Elevators, escalators, gates, compres-
delayed switching. Switching several fans can be found everywhere in sors and doors - here too ABB timers
rows of lamps on and off in corridors, buildings - just like the CT-D timers ensure optimum and time-delayed
stairwells, staircases, etc, is a long used to switch them. On-delay, opening as required. ABB ́ s CT-D
widespread application in which the off-delay and a range of other timers cover most functions with just
excellent functionality of the CT-D functions cover all requirements. 12 order codes.
timers is undisputed.
44 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
CT-D range
Benefits and advantages
The CT-D range is ideal for building applications and installation panels, due to its
compact modular housing. For maximum flexibility in operation, nine single-function
as well as two multifunction devices with seven timing functions are available. The
devices offer four or seven time ranges from 0.05 seconds up to 100 hours. Their
wide supply voltage range allows their use in applications worldwide.
The CT-D range is ideal for installation panels thanks to its compact modular housing. The housing’s
design helps make the status and configuration more clearly visible. The CT-D range also offers a
higher output current than standard industrial types. As well as the 1 c/o contacts, ABB offers
Space savings devices with 2 c/o contacts for maximum flexibility.
Direct reading scales help make time setting quick and easy. A pre-selection for the time range
together with an additional scale for fine adjustments help improve installation efficiency. For more
flexibility, the delay time can even be changed when processes are running, making optimization to
Easy to install fit the application even simpler. All devices can be mounted and demounted tool-free.
The CT-D range fulfills various global standards and approvals, supporting business worldwide.
Additionally, all devices from the CT-D range have a wide supply voltage from 24-48 V DC and
Global availabilty 24-240 V AC, making it ideal for the use in installation panels around the world.
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 45
—
CT-D range
Operating controls
Width 17.5 mm
With a width of just 17.5 mm, the
CT-D range timers are ideally
suited for installation in distribu-
tion panels.
Connection terminals
Wide terminal spacing makes
connection of wires simpler:
2 x 1.5 mm² (2 x 16 AWG) with wire
end ferrules or 2 x 2.5 mm² (2 x 14
AWG) without ferrules.
—
CT-D range
Selection table
1SVR500020R0000
1SVR500150R0000
1SVR500100R0000
1SVR500130R0000
1SVR500160R0000
1SVR500110R0000
1SVR500020R1100
1SVR500100R0100
1SVR500160R0100
1SVR500210R0100
1SVR500110R0100
1SVR500211R0100
Order number
CT-VWD.12
CT-MFD.21
CT-MFD.12
CT-AHD.22
CT-AHD.12
CT-SDD.22
CT-TGD.22
CT-ERD.22
CT-SAD.22
CT-EBD.12
CT-TGD.12
CT-ERD.12
Type
Timing function
ON-delay A J J J J
OFF-delay with aux. voltage B J J J J
Impulse-ON CA J J J
Impulse-OFF with aux. voltage CB J J
Flasher starting with ON DA J J J
Flasher starting with OFF DB J J
Pulse generator starting with ON or OFF ED J J
Pulse former H J J
Star-delta change-over F J J
Features
Control input, voltage-related triggering J J J J J J
Time range
0.05 s - 100 h J J J J J J J J 2 2
0.05 s - 10 min J J
Supply voltage
12-240 V AC/DC J
24-48 V DC J J J J J J J J J J J
24-240 V AC J J J J J J J J J J J
Output
c/o contact 1 2 1 2 1 2 1 1 1 2
n/o contact 2 2
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 47
—
CT-D range
Ordering details
Description
The CT-D range with its modular design is a perfect solution for installation panels. For
maximum flexibility in operation, 10 single-function as well as two multifunction devices
with seven timing functions are available. The devices offer four or seven time ranges from
0.05 seconds up to 100 hours. Their wide input range allows their use in applications
2CDC251002V0018
worldwide.
—
CT-MFD.12 Ordering details
Timing Rated control Time Control Output Type Order code Weight
function supply ranges input (1 pc)
voltage
kg (lb)
1)
Functions: ON-delay, OFF-delay with auxiliary voltage, Impulse-ON, Impulse-OFF with
auxiliary voltage, Flasher starting with ON, Flasher starting with OFF, Pulse former
2)
ON and OFF times adjustable independently: 2 x 7 time ranges 0.05 s - 100 h
3)
Transition time 50 ms fixed
4)
Transition time adjustable
48 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
CT-D range
Technical data
—
CT-D range
Technical data
—
CT-D range
Technical data
—
CT-D range
Technical diagrams
—
Example of application - Star-delta changeover
L1 F3 L1 L2 L3
95 1 3 5
F2 -F1
96 2 4 6
S1 21
0
22
S2 13 53
I K2
14 54
1 3 5 1 3 5 1 3 5
-K2 2 4 6
-K3 2 4 6
-K1 2 4 6
17 17 13 13
K1T K2 K1
18 28 14 14
22 22 1 5 4 97 95
K3 K1 -F2
21 21 98 96
3 2 6
A1 A1 A1 A1
K1T K1 K3 K2 -M1
2CDC253009F0012
2CDC252128F0006
A2 A2 A2 A2 W1 W2
N V1 M V2
U1 3~ U2
Y i N
—
CT-D range
Technical diagrams
—
Connection diagrams
2CDC252114F0b06
2CDC252115F0b06
2CDC252113F0b06
2CDC252177F0b05
A2 16 18 26 28 A2 16 18 A2 16 18 26 28 A2 16 18
18 16 Y1/B1 18 16
18 16 A2 18 16 A2
28 26 A2 28 26 A2
15-16/18 1st c/o contact A1-Y1/B1 Control input 15-16/18 1st c/o contact 15-16/18 1st c/o contact
25-26/28 2nd c/o contact 15-16/18 1st c/o contact 25-26/28 2nd c/o contact
A1 15 25 A1 15 Y1/B1 A1 15 A1 15
Y1/ Y1/
B1 A1 15 25 B1 A1 15 A1 15 A1 15
2CDC252180F0B05
2CDC252116F0b06
2CDC252179F0b05
2CDC252117F0b06
A2 16 18 26 28 A2 16 18 A2 16 18 A2 16 18
18 16 Y1/B1
18 16 A2 18 16 A2 18 16 A2
28 26 A2
A1 15 25 A1 15 Y1/B1 A1 17 A1 17
Y1/ Y1/
B1 A1 15 25 B1 A1 15 A1 17 A1 17
2CDC 252160F0b06
2CDC 252160F0b06
2CDC252118F0b06
2CDC252119F0b06
A2 16 18 26 28 A2 16 18 A2 18 28 A2 18 28
18 16 Y1/B1
18 16 A2 28 18 A2 28 18 A2
28 26 A2
—
CT-D range
Technical diagrams
—
Load limit curves
—
AC load (resistive) DC load (resistive) Derating factor F
for inductive AC load
CT-D.1x CT-D.1x
1.0
2CDC 252 044 F0207
Derating factor F
0.9
0.8
2CDC252124F0206
0.6
2CDC252044F0207
2CDC252045F0207
0.5
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
AC current [A] cos ϕ
DC current [A]
—
CT-D.2x CT-D.2x
Contact lifetime
2CDC 252 122 F0206
Switching cycles
2CDC252123F0206
AC current [A] DC current [A]
Switching current [A]
— —
Wiring notes for devices with Dimensional drawings
control input in mm and inches
L(+)
2CDC 252 102 F0b06
80 3.15“
45 1.77“
70 2.76“
45 1.77“
A1 Y1/B1
2CDC252130F0006
2CDC252131F0b06
2CDC252102F0006
2CDC
A2
CT-D devices with 1 c/o contact CT-D devices with 2 c/o contacts
or 2 n/o contacts
N(-)
54 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 55
—
Timing functions
56 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
Timing functions
CT-C, CT-S, CT-D
OFF-delay with auxiliary voltage This function requires a continuous control supply voltage
for timing. If the control input is closed, the output relay
Supply
energizes immediately. If the control input is opened, the
Control input
time delay starts. When the selected time delay is complete,
Output
t <t the output relay de-energizes.
If control input re-closes before the time delay is complete,
the time delay is reset and the output relay does not change
state. Timing starts again when the control input re-opens.
If the control supply voltage is interrupted, the output relay
de-energizes and the time delay is reset.
OFF-delay without auxiliary voltage The OFF-delay function without auxiliary voltage does not
require a continuous control supply voltage for timing.
Supply
Applying a control supply voltage energizes the output relay.
Output
If the control supply voltage is interrupted, the OFF-delay
t
starts. When timing is complete, the output relay
de-energizes.
If a control supply voltage is re-applied before the time delay
is complete, the time delay is reset and the output relay
remains energized. A control supply voltage must be applied
for the minimum energizing time (200 ms), for correct
operation.
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 57
—
Timing functions
CT-C, CT-S, CT-D
OFF-delay with auxiliary voltage, accumulative This function requires a continuous control supply voltage
for timing. If the control input is closed, the output relay
Supply
Control input 1 energizes immediately. If the control input is opened, the
Output time delay starts. When the selected time delay is complete,
t= delay
the output relay de-energizes. If the control input closes
2nd instanteous
contact before the time delay is complete, the time delay is reset
Control input 2
t1 t3 t2
and the output relay does not change state. Timing starts
t=t1+t2 t3 = pause again when the control input reopens.
Impulse-ON functions CA
Impulse-ON (interval)
This function requires a continuous control supply voltage
Supply
for timing. The output relay energizes immediately when the
Output control supply voltage is applied and de-energizes after the
t <t set pulse time is complete. If the control supply voltage is
interrupted, the output relay de-energizes and the time
delay is reset.
—
Timing functions
CT-C, CT-S, CT-D
Impulse-OFF functions CB
Impulse-OFF with auxiliary voltage This function requires a continuous control supply voltage
for timing. The output relay energizes immediately when the
Supply
control input is de-energized and the output de-energizes
Control input
after the set pulse time is complete. If the control supply
Output
t <t voltage is interrupted, the output relay de-energizes and the
time delay is reset.
Impulse-OFF without auxiliary voltage This function does not require a continuous control supply
voltage for timing.
Supply If the control supply voltage is interrupted, the output relay
Output
energizes and the OFF time starts. When timing is complete,
t
the output relay de-energizes. If a control supply voltage is
re-applied before the time delay is complete, the time delay
is reset and the output relay de-energizes. A control supply
voltage must be applied for the minimum energizing time
(200 ms), for proper operation.
Impulse-OFF with auxiliary voltage This function requires a continuous control supply voltage
(Trailing edge interval) accumulative for timing. If a control supply voltage is applied, opening
control input 1 energizes the output relay immediately and
Supply
starts timing. When the selected pulse time is complete, the
Control input 1
output relay de-energizes. Closing control input 1, before
Output
t the pulse time is complete, de-energizes the output relay
2nd instanteous and resets the pulse time.
contact
Control input 2
Pause timing / Accumulative impulse-OFF:
t1 t3 t2 Timing can be paused by closing control input 2. The elapsed
t3 = pause
t1 + t2 = t
time t1 is stored and continues from this time value when
control input 2 is re-opened. This can be repeated as often
as required. If the control supply voltage is interrupted, the
output relay de-energizes and the time delay is reset.
Impulse-ON and impulse-OFF This function requires a continuous control supply voltage
for timing. If a control supply voltage is applied, closing the
Supply control input energizes the output relay immediately and
Control input
starts the pulse time t1. When t1 is complete, the output
Output
t1 t2 <t1
relay de-energizes. Re-opening the control input energizes
the output relay immediately and starts the pulse time t2.
When t2 is complete, the output relay de-energizes. t1 and t2
are independently adjustable. If the control input changes
state before the pulse time is complete, the output relay
de-energizes and the pulse time is reset. If the control input
changes state again, the interrupted pulse time restarts. If
the control supply voltage is interrupted, the output relay
de-energizes and the time delay is reset.
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 59
—
Timing functions
CT-C, CT-S, CT-D
Flasher starting with ON Applying a control supply voltage starts timing with
symmetrical ON & OFF times. The cycle starts with an ON
Supply
time first. If the control supply voltage is interrupted, the
Output
t t
output relay de-energizes and the time delay is reset.
Flasher with reset starting with ON Applying a control supply voltage starts timing with
symmetrical ON & OFF times. The cycle starts with an ON
Supply time first. The time delay can be reset by closing the control
Control input
input. Opening the control input starts the timer pulsing
Output
t t t t
again with symmetrical ON & OFF times. If the control
2nd contact supply voltage is interrupted, the output relay de-energizes
instantaneous
and the time delay is reset.
Flasher starting with OFF Applying a control supply voltage starts timing with
symmetrical ON & OFF times. The cycle starts with an OFF
Supply
time first. If the control supply voltage is interrupted, the
Output
t t
output relay de-energizes and the time delay is reset.
Flasher with reset starting with OFF Applying a control supply voltage starts timing with
symmetrical ON & OFF times. The cycle starts with an OFF
Supply
time first. The time delay can be reset by closing the control
Control input
input. Opening the control input starts the timer pulsing
Output
t t t t again with symmetrical ON & OFF times. If the control
supply voltage is interrupted, the output relay de-energizes
2nd contact
instantaneous and the time delay is reset.
—
Timing functions
CT-C, CT-S, CT-D
Pulse former H
Puls former (single shot) This function requires a continuous control supply voltage
for timing. Closing the control input energizes the output
Supply relay immediately and starts timing. Operating the control
Control input
input during the time delay has no effect. When the selected
Output
t t ON time is complete, the output relay de-energizes. After
the ON time is complete, it can be restarted by closing the
control input. If control supply voltage is interrupted, the
output relay de-energizes and the time delay is reset.
Single-pulse generator EC
Single-pulse generator, starting with OFF This function requires a continuous control supply voltage
for timing. Applying a control supply voltage while the
Supply
Control input
control input is open energizes the output relay after the
Output OFF time t1 is complete. When the following ON time t2 is
t1 t2 t1 t2 complete, the output relay de-energizes. Alternatively, when
a control supply voltage is already applied, the timing
process can be started by opening control input. Closing the
control input with a control supply voltage applied,
de-energizes the output relay and re- sets the time delay.
The ON & OFF times are independently adjustable.
Pulse generator ED
Starting with the ON or OFF time This function requires a continuous control supply voltage
(Recycling unequal times, ON or OFF first) for timing. Applying a control supply voltage, with closed
control input, starts timing with an OFF time first. Applying
Supply a control supply voltage, with open control input, starts
Control input
timing with an ON time first. If the control supply voltage is
Output
t1 t2 t2 t1 interrupted, the output relay de-energizes and the time
delay is reset.
Fixed impulse with adjustable time delay This function requires a continuous control supply voltage
for timing. The time delay t1 starts when a control supply
Supply voltage is applied. When t1 is complete, the output relay
Output energizes for the fixed impulse time t2 of 500 ms.
t1 t2 <t1
If the control supply voltage is interrupted, the time delay is
re- set. The output relay does not change state.
Adjustable impulse with fixed time delay This function requires a continuous control supply voltage
for timing. As soon as the control supply voltage is applied,
Supply the time delay t2 (fixed 500 ms) starts. When t2 is complete,
Output the output relay energizes and the selected pulse time t1
t2 t1 t2 <t1
starts. When t1 is complete, the output relay de-energizes. If
the control supply voltage is interrupted, the pulse time is
reset and the output relay de-energizes.
ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS 61
—
Timing functions
CT-C, CT-S, CT-D
Symmetrical ON- and OFF-delay 1) This function requires a continuous control supply voltage
for timing. Closing the control input starts the ON-delay
Supply time t1. When timing is complete, the output relay energizes.
Control input
Opening the control input starts the OFF-delay time t2.
Output
t1 t2 t1 <t2 When the OFF-delay t2 is complete, the output relay
2nd instanteous de-energizes. If the control input opens before the ON-delay
contact
t1=t2 (<t1) is complete, the time delay is reset and the output relay
remains de-energized. If control input closes before the
OFF-delay time (<t2) is complete, the time delay is reset and
the output relay remains energized.
1) Variant with 2nd control input for pause timing is available too.
Asymmetrical ON- and OFF-delay This function requires a continuous control supply voltage for
timing. Closing the control input starts the ON-delay t1. When
Supply timing is complete, the output relay energizes. Opening the
Control input
control input starts the OFF-delay t2. When the OFF-delay is
Output
t1 t2 t1 <t2 complete, the output relay de-energizes. The ON-delay and
OFF-delay are independently adjustable.
If the control input opens before the ON-delay is complete
(<t1), the time delay is reset and the output relay remains
de-energized. If the control input closes before the OFF-delay
is complete (<t2), the time delay is reset and the output relay
remains energized. If the control supply voltage is interrupted,
the output relay de-energizes and the time delay is reset.
Star-Delta changeover (with impulse) F FC This function requires a continuous control supply voltage
for timing. Applying a control supply voltage, energizes the
star contactor connected to output 1 and begins the set
Supply starting time t1. When the starting time is complete, the
Output 1 first output contact de-energizes the star contactor. When
Output 2
the transition time t2 is complete, the second output
t1 t2 t1 = adjusted starting time
t2 = transition time contact energizes the delta contactor. The delta contactor
remains energized as long as the control supply voltage is
applied. t2 is fixed to 50 ms or in some variants adjustable.
Further functions This function is used for test purposes during commis-
sioning and troubleshooting. If the selected maximum value
ON/OFF function G of the time range is smaller than 300 hours (front-face
potentiometer “Time sector” ≠ 300 h), applying a control
Supply supply voltage energizes the output relay immediately. Inter-
Output
rupting the control supply voltage, de-energizes the output
Time sector ≠ 300 h Time sector = 300 h
relay. If the selected maximum value of the time range is 300
hours (front- face potentiometer “Time sector” = 300 h) and a
control supply voltage is applied the output relay does not
energize.
Alternating without time delay The alternating function is designed to evenly use the electro-
mechanical resource of a twin pump, compressors and gener-
Supply
ators. The alternating relay has two normally open contacts,
Output 1
Output 2
which are closed alternately each time the control supply
voltage is applied.
62 ELECTRONIC RELAYS AND CONTROLS CATALOG TIME RELAYS
—
Index
Product type
—
Index
Order code
abb.com/lowvoltage
2CDC11004C0210_01 Rev. I (11/2021)
—
We reserve the right to make technical We reserve all rights in this document and
changes or modify the contents of this in the subject matter and illustrations con-
document without prior notice. With tained therein. Any reproduction, disclo-
regard to purchase orders, the agreed par- sure to third parties or utilization of its
ticulars shall prevail. ABB AG does not contents – in whole or in parts – is forbid-
accept any responsibility whatsoever for den without prior written consent of
potential errors or possible lack of infor- ABB AG Copyright© 2021 ABB AG
mation in this document. All rights reserved