Datasheet Abb Uno DM 1-2 2-0 3-0 TL Plus Q

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

SOL AR INVERTERS

ABB string inverters


UNO-DM-1.2/2.0/3.0-TL-PLUS-Q
1.2 to 3.0 kW
The UNO-DM-TL-PLUS-Q
single-phase inverter family, with
power ratings from 1.2 to 3.0 kW, is
the optimal solution for residential
installations.

— One size fits all The advanced communication interfaces (WLAN,


UNO-DM-TL-PLUS-Q
outdoor string inverter
The design wraps ABB’s quality and engineering into a Ethernet, RS485) combined with an efficient
lightweight and compact package thanks to Modbus (RTU/TCP) communication protocol,
technological choices optimized for installations with Sunspec compliant, allow the inverter to be easily
a uniform orientation. integrated within any smart environment and with
third party monitoring and control systems.
All power ratings share the same overall volume, A complete set of control functions with the
allowing higher performance in a minimum space, embedded efficient algorithm, enabling dynamic
and are available with single Maximum Power Point control of the feed-in (i.e. zero injection), make the
Trackers. inverter suitable for worldwide applications in
compliance with regulatory norms and needs of the
Easy to install, fast to commission utilities.
The presence of Plug and Play connectors, both on
the DC and AC side, as well as the wireless ABB Ability™ Energy Viewer for solar plants
communication, enable a simple, fast and safe This new tool allows residential customers to
installation without the need of opening the front remotely monitor the performance of their own
cover of the inverter. solar plant and provides all information necessary to
The featured easy commissioning routine removes increase energy self-reliance and self-sufficiency.
the need for a long configuration process, resulting
in lower installation time and costs. Highlights
Improved user experience thanks to the build in • Wireless access to the embedded Web User
User Interface (UI) or the Installer for Solar Inverters Interface
app which enable access to features such as advanced • Easy commissioning capability
inverter configuration settings, dynamic feed-in • Future-proof with embedded connectivity for smart
control and load manager, from any WLAN enabled building and smart grid integration
device (smartphone, tablet or PC). • Dynamic feed-in control (for instance “zero
injection”)
Smart capabilities • Remote firmware upgrade for inverter and
The embedded logging capabilities and direct components
transferring of the data to Internet (via Ethernet or • Modbus TCP/RTU Sunspec compliant
WLAN) allow customers to enjoy the whole Aurora • Lifetime free of charge access to Aurora Vision
Vision® remote monitoring experience.
P R O D U C T F LY E R F O R U N O - D M - 1 . 2 / 2 . 0/ 3 . 0 -T L - P L U S - Q A B B S O L A R I N V E R T E R S


ABB string inverters
UNO-DM-1.2/2.0/3.0-TL-PLUS-Q
1.2 to 3.0 kW


Technical data and types

Type code UNO-DM-1.2-TL-PLUS-Q UNO-DM-2.0-TL-PLUS-Q UNO-DM-3.0-TL-PLUS-Q


Input side
Absolute maximum DC input voltage (Vmax,abs) 600 V
Start-up DC input voltage (Vstart) 120 V (adj. 100…150 V) 150 V (adj. 100…250 V) 150 V (adj. 100…250 V)
Operating DC input voltage range
0.7 x Vstart ...580 V (min 90 V)
(Vdcmin ...Vdcmax)
Rated DC input voltage (Vdcr) 185 V 300 V 300 V
Rated DC input power (Pdcr) 1500 W 2500 W 3300 W
Number of independent MPPT 1 1 1
Maximum DC input power for each MPPT (P MPPTmax) 1500 W 2500 W 3300 W
DC input voltage range with parallel configuration of
100…530 V 210...530 V 320...530 V
MPPT at Pacr
DC power limitation with parallel configuration of MPPT N/A N/A N/A
DC power limitation for each MPPT with independent
configuration of MPPT at Pacr, N/A N/A N/A
max unbalance example
Maximum DC input current (I dcmax) /
10.0 A 10.0 A 10.0 A
for each MPPT (I MPPTmax)
Maximum input short circuit current for each MPPT 12.5 A 12.5 A 12.5 A
Number of DC input pairs for each MPPT 1
DC connection type 1) Quick Fit PV Connector
Input protection
Reverse polarity protection Yes, from limited current source
Input over voltage protection for each MPPT-varistor Yes
Photovoltaic array isolation control According to local standard
DC switch rating for each MPPT
25 A / 600 V
(version with DC switch)
Output side
AC grid connection type Single-phase
Rated AC power (Pacr @cosφ=1 ) 1200 W 2000 W 3000 W
Maximum AC output power (Pacmax @cosφ=1) 1200 W 2000 W 3000 W
Maximum apparent power (S max) 1200 VA 2000 VA 3000 VA
Rated AC grid voltage (Vac,r) 230 V
AC voltage range 2) 180...264 V
Maximum AC output current (I ac,max) 5.5 A 10.0 A 14.5 A
Contributory fault current 10.0 A 12.0 A 16.0 A
Rated output frequency (fr) 3) 50/60 Hz
Output frequency range (fmin ...fmax) 3) 47...53/57...63 Hz
Nominal power factor and adjustable range > 0.995, adj. ± 0.1 - 1 (over/under excited)
Total current harmonic distortion < 3.5%
AC connection type Female connector from panel
Output protection
Anti-islanding protection According to local standard
Maximum external AC overcurrent protection 10.0 A 16.0 A 16.0 A
Output overvoltage protection - varistor 2 (L - N / L - PE)
P R O D U C T F LY E R F O R U N O - D M - 1 . 2 / 2 . 0/ 3 . 0 -T L - P L U S - Q A B B S O L A R I N V E R T E R S

ABB UNO-DM-1.2/2.0/3.0-TL-PLUS-Q string inverter block diagram

MPPT 1 Inverter Line Grid parallel


(DC/DC) Bulk caps (DC/AC) filter relay
+ + +
IN1(+) IN1(+) L

IN1 IN1 IN1

IN1(-) IN1(-) N
- - -

Standard version -S version


PE

Residual current
detection Optional
RS485
+ T/R
- T/R
RTN
DC/DC DC/AC
DSP DSP Remote control
contr. contr. +R
-R

Load manager/
µP Alarm
N.C
N.O
C

Control circuit

WLAN


Technical data and types

Type code UNO-DM-1.2-TL-PLUS-Q UNO-DM-2.0-TL-PLUS-Q UNO-DM-3.0-TL-PLUS-Q


Operating performance
Maximum efficiency (ηmax) 94.8% 96.7% 96.7%
Weighted efficiency (EURO/CEC) 92.0%/- 95.0%/- 90.0%/-
Feed in power threshold 8W
Night consumption <0.4 W
Embedded communication
Embedded communication interface 4) Wireless
Embedded communication protocol ModBus TCP (SunSpec)
Commissioning tool Web User Interface, Aurora Manager Lite
Plant Portfolio Manager, Plant Viewer, Plant Viewer for Mobile,
Monitoring
ABB Ability™ Energy Viewer for solar plants
Optional board UNO-DM-COM kit
RS485 (use with meter for dynamic feed-in control), Alarm/Load manager relay, Remote
Optional communication interface
ON/OFF
Optional communication protocol ModBus RTU (SunSpec), Aurora Protocol
Optional board UNO-DM-PLUS Ethernet COM kit
Ethernet, RS485 (use with meter for dynamic feed-in control),
Optional communication interface
Alarm/Load manager relay, Remote ON/OFF
Optional communication protocol ModBus TCP (SunSpec), ModBus RTU (SunSpec), Aurora Protocol
Environmental
-25...+60°C /-13...140°F with -25...+60°C /-13...140°F with -25...+60°C /-13...140°F with
Ambient temperature range
derating above 50°C/122°F derating above 50°C/122°F derating above 50°C/122°F
Relative humidity 0...100 % condensing
Acoustic noise emission level 50 dBA @ 1 m
Maximum operating altitude without derating 2000 m / 6560 ft
Physical
Environmental protection rating IP 65
Cooling Natural
Dimension (H x W x D) 553 x 418 x 175 mm / 21.8” x 16.5” x 6.9”
Weight 15 kg / 33 lbs
Mounting system Wall bracket
Safety
Isolation level Transformerless
Marking CE , RCM
IEC/EN 62109-1, IEC/EN 62109-2, AS/NZS 4777.2, EN 61000-6-1,EN 61000-6-2, EN 61000-
Safety and EMC standard
6-3, EN 61000-6-4, EN 61000-3-2, EN 61000-3-3
Grid standard CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105, G83/2, G59/3, RD 413, ITC-BT-40,
(check your sales channel for availability) 5) AS/NZS 4777.2, IEC 61727, IEC 62116
Available products variants
Standard UNO-DM-1.2-TL-PLUS-B-Q UNO-DM-2.0-TL-PLUS-B-Q UNO-DM-3.0-TL-PLUS-B-Q
With DC switch UNO-DM-1.2-TL-PLUS-SB-Q UNO-DM-2.0-TL-PLUS-SB-Q UNO-DM-3.0-TL-PLUS-SB-Q

1)
“Refer to the document “String inverter – Product Manual appendix” available at As per IEEE 802.11 b/g/n standard
4)

www.abb.com/solarinverters to know the brand and the model of the quick fit Further grid standard will be added, please refer to ABB Solar page for further details
5)

connector” Remark. Features not specifically listed in the present data sheet are not included in
2)
The AC voltage range may vary depending on specific country grid standard the product
3)
The Frequency range may vary depending on specific country grid standard;
CE is valid for 50Hz only
UNO-DM-TL-PLUS-Q-1.2/2.0/3.0_9AKK107046A8885_EN REV - A 19.12.2018

— —
For more information please contact We reserve the right to make technical We reserve all rights in this document and
your local ABB representative or visit: changes or modify the contents of this in the subject matter and illustrations
document without prior notice. With contained therein. Any reproduction,
regard to purchase orders, the agreed disclosure to third parties or utilization of
www.abb.com/solarinverters particulars shall prevail. ABB AG does not its contents – in whole or in parts – is
www.abb.com accept any responsibility whatsoever for forbidden without prior written consent of
potential errors or possible lack of ABB AG. Copyright© 2018 ABB
information in this document. All rights reserved

You might also like