5.2 CLIVET Air Cooled Inv-Screw Chiller

Download as pdf or txt
Download as pdf or txt
You are on page 1of 17

Clivet-10C202103

Commercial Air Conditioners 2021

AirBoost Screw INVERTER


Air Cooled Screw Chiller
CLIVET SPA
Via Camp Lonc 25, Z.I. Villapaiera - 32032 Feltre (BL) - Italy
Tel. + 39 0439 3131 - Fax + 39 0439 313300 - [email protected]
w w w. c l i ve t . co m
w w w.c livetlive.co m T1 series/ T3 series/ All year round cooling series/ Free cooling series
Overview
CLIVET. CHANGE THINGS

Overview
AirBoost air cooled screw chiller is designed to realize peak efficiency under all operating conditions, all year round cooling, free

cooling, quick start and low noise operation.

It can be widely used in large and medium-sized commercial, civil or industrial buildings and is ideal for data centers, cold

04 OVERVIEW storages, temperature sensitive operations such as pharmaceutical labs, hospitals, and manufacturing facilities require constant

cooling for equipment and processes, places where the chillers will probably be installed near noise sensitive places such as

guest room and meeting room, etc.

NOMENCLATURE

05 FEATURES
W D A T - CN 115 . 1 H 22 V (T3)

Liquid chiller
Omit: normal condition (T1)
09 SPECIFICATIONS Screw compressor
T3: tropical condition
LA: all year round cooling
FC-D: direct free cooling
FC-I: indirect free cooling
Air cooled
Inverter
Cooling only
15 DIMENSIONS AND BASE DIAGRAMS Omit for 50Hz; 22: 460V-60Hz
Design serial number
High efficiency

Cooling capacity: RT Compressor quantity

20 INSTALLATION AND MAINTENANCE UNIT MEMBER

Double oil separation Flooded evaporator


Compressor filter + centrifugal oil separation,
oil rate of heat exchanger is below 0.03%
Low noise fan
21 OPTIONS VFD
Fin-coil condenser

Control panel

23 INTELLIGENT MANAGEMENT Precise EXV


Built-in touch screen

25 REFERENCE PROJECTS Specifically designed compressor Noise reduction box for compressor
Variable frequency drive (from 25Hz to 70Hz),
high part load energy efficiency
0.1HZ INVERTER TECHNOLOGY
Features International leading inverter regulation technology can achieve 0.1Hz frequency regulation, so as to achieve high-precision water
temperature control, trend prediction, self-diagnosis, advance regulation, avoid frequent temperature fluctuations and even
HIGH EFFICIENCY INVERTER SCREW COMPRESSOR shutdown, improve user comfort and reduce energy consumption.

Temperature change under Temperature change under


conventional control prospective control
Features

Features
The screw rotor adopts the optimized compression process profile design, not only ensures excellent volume efficiency,
ZERO IN-RUSH CURRENT
but also reduces the leakage of the compressor. The twin screw rotor adopts five teeth to six teeth asymmetrical design,
The unit adopts inverter starting mode, which produces zero in-rush current during the starting process and enables a stable
the machining accuracy is as high as micron level, stable and reliable.
operation from 0A to FLA.
Refrigerant cooled large capacity inverter motor design, high motor efficiency. The screw rotor is driven by motor directly, 600
less moving parts and wearing parts, high mechanical efficiency. 500
The compressor is specifically designed to run with the newest variable frequency technology. Running freely from 25Hz to 400 Across-in-line (600%-800%)

100% FLA
Solid state soft start (300%-400%)
70Hz, high part load energy efficiency. 300 Autotransformer start (400%-500%)
Star-delta start (200%-300%)
200 Inverter start (100%)
HIGH EFFICIENCY AIR SIDE HEAT EXCHANGER 100
0
High efficiency and low noise axial flow fan. The fan impeller design is optimized by 1 2 5 10 20 30 40 50 60 Time: s

professional flow field software to ensure that the impeller has good aerodynamic
performance, which ensures that the fan operates with low noise and at the same
QUICK START
time obtains larger air volume and improves the heat transfer effect of the air side.
Inverted M-type air-side heat exchanger, the airflow is evenly distributed to achieve It takes only 180s to return to 100% capacity while other comparable chillers need at least 300s to reach full load. Ideal for
high efficiency heat exchange. temperature sensitive applications such as data centers, manufacturing processes and hospitals where need the unit to
High efficiency inner-threaded pipes and high quality arc-shaped window aluminum
restart quickly after a power failure.
fins are closely combined by mechanical expansion pipe to improve heat transfer
efficiency, reduce pressure loss and wind noise. Time to reach full load (s)

Professional temperature field simulation, optimized design.


Other air cooled screw chiller

HIGH EFFICIENCY FLOODED EVAPORATOR


AirBoost air cooled screw chiller

The refrigerant distributor can distribute refrigerant evenly, optimize the temperature field and improve the evaporation 0 50 100 150 200 250 300 350
temperature, so as to improve the operating efficiency.
Specially designed baffle plate to avoid the compressor suction with liquid, improving the reliability of the unit.
RELIABLE AND EASY INSTALLATION
The water box at both ends can be disassembled to facilitate maintenance.
Gas refrigerant
Modular design, maximum 8 units can be combined.
Each unit adopts 1 or 2 compressors and each compressor is equipped with an independent refrigeration circuit.
Chilled water outlet The compressors of the 2-circuit unit can be used as backup for each other. The running time of each compressor of a
2-circuit unit and each unit in a whole system can both be balanced and the service life of the whole system is extended.
No need for a dedicated equipment room or purchase cooling tower and other accessories.
Chilled water inlet Liquid refrigerant

QUIET OPERATION
HIGH PRECISION EXV

Internationally renowned brands, stable and reliable quality. Optimized system design, eliminate abnormal noise caused by flow.
Responsive, no hysteresis, improve unit energy efficiency. 5~10dBA noise reduction (standard with sound insulation box and low noise fan).
PID high-precision adjustment to ensure that the whole situation is stable and efficient operation. Double layer sound insulation material + super low noise fan (customized).

The inner wall of the box is made of highly Super low noise solution fan
effective silencing materials
High precision EXV Traditional thermal expansion valve

05 06
ECO-FRIENDLY TWO CONFIGURATIONS

Direct free cooling


R134a refrigerant has zero ozone depletion potential and has no elimination cycle for now.
The refrigerant complies with the Montreal Protocol. Circulating water in the project system is with glycol.

Free cooling fin + electric three-way valve, achieve free cooling at


WIDE AMBIENT TEMPERATURE RANGE EXV

low ambient temperature.


The unit can operate stably under extreme conditions, ranging from -25°C to 52°C.
Direct heat exchange, high heat exchange efficiency.

Overall project circulating water is anti-freeze liquid, strong


Features

Features
5°C 48°C 5°C 52°C
anti-freezing ability.

T1 series T3 series Client requires consideration of glycol system design.

-20°C 48°C -25°C 48°C

All year round cooling series Free cooling series Indirect free cooling

Circulating water in the project system is conventional water.


INTELLIGENT CONTROL
Free cooling fin, plate heat exchanger and glycol circulating
7-inch colorful touch screen. pump to form a closed system.
Real-time operating parameters (temperature, pressure etc.) display. Equipped with plate heat exchanger, transfer free cooling
EXV Glycol inside
the unit
Three-level password setting to prevent misoperation. energy to the whole project.
Detailed fault information record. The terminal system and the water pump do not need to
Power-off memory function. consider the performance attenuation and water resistance
Timed ON/OFF. increase caused by antifreeze liquid.
Master & Slave, Back-up, Duty cycling. Two-stage heat exchange can reduce heat exchange
Compatible with QuickView, M-Cloud, Clivet Chiller Plant requirements of the compressor.
No-Glycol inside
Control and M-BMS. No need for special water system design. the project system

FREE COOLING SOLUTIONS

For industrial or civil applications where cooling capacity required is THREE OPERATING MODES

stable in any outdoor condition and it is not effected by outdoor

temperature, using solutions that exploit low outdoor temperatures

for supplying cooling capacity for free is strongly suggested. Air


flow
Refrigerant system

When the outdoor temperature is lower than the temperature of the


Glycol soluton

system's return water, the free cooling system recovers cold from the

external environment and reduces the operation of the compressors

until they stop completely.

Clivet solution is: Built-in free cooling heat exchanger, less space;
Free cooling is off. Free cooling is on. Free cooling is on.
Free cooling and compressor refrigeration sharing a set of fans, Compression cycle is on. Compression cycle is on. Compression cycle is off.
energy saving and easy maintenance.

07 08
Specifications
380V-3Ph-50Hz 380V-3Ph-50Hz
Direct free cooling series, WDAT-CN***HV(FC-D) Model 115 140 175 205 245 285 330 400
T1 series, WDAT-CN***HV Model 115 140 175 205 245 285 330 385 415

Cooling capacity kW 397.1 500.6 618.1 723.8 838.4 965.6 1158.1 1390.9
T3 series, WDAT-CN***HV(T3) Model 115 140 175 205 245 285 330 385 415
Power input kW 121.4 156.4 192.0 224.8 254.8 300.8 352.0 434.7
All year round cooling series, WDAT-CN***HV(LA) Model 115 140 175 205 245 285 330 385 415 Nominal parameter
Cooling COP kW/kW 3.27 3.20 3.22 3.22 3.29 3.21 3.29 3.20
Cooling capacity kW 397.1 500.6 618.1 723.8 838.4 965.6 1158.1 1367.6 1448.4
IPLV kW/kW 4.57 4.53 4.52 4.54 4.58 4.51 4.53 4.52
Power input kW 116.5 145.9 181.3 212.3 245.9 284.0 339.6 402.2 426.0
Nominal parameter Cooling capacity kW 397.1 500.6 618.1 723.8 838.4 965.6 1158.1 1390.9
Cooling COP kW/kW 3.41 3.43 3.41 3.41 3.41 3.40 3.41 3.40 3.40
Free cooling only parameter Power input kW 19.6 19.6 24.5 29.4 34.3 39.2 44.1 49.0
IPLV kW/kW 4.91 4.98 5.03 5.02 5.03 5.01 4.93 5.03 5.01
COP kW/kW 20.26 25.54 25.23 24.62 24.44 24.63 26.26 28.39
Specifications

Specifications
Type / Semi-hermetic twin-rotor screw compressor
Ambient temperature of free cooling only °C 2.37 2.79 2.87 3.05 3.10 3.04 2.58 1.98
Compressor
Quantity / 1 1 1 1 1 1 2 2 2
Free cooling only heat exchange temperature difference °C 7.63 7.21 7.13 6.95 6.90 6.96 7.42 8.02

Energy regulation mode / Stepless control (Single compressor 10%-100% , Dual compressor 5%-100%) Type / Semi-hermetic twin-rotor screw compressor
Compressor
Type / R134a Quantity / 1 1 1 1 1 1 2 2

Refrigerant Charge amount kg 126 148 168 192 225 280 2×168 2×185 2×200 Energy regulation mode / Stepless control (Single compressor 10%-100% , Dual compressor 5%-100%)

Power supply / 380V-3Ph-50Hz Type / R134a

Rated current A 192.2 242.2 302.2 350.1 411.1 474.0 563.1 668.9 720.8 Refrigerant Charge amount kg 126 148 168 192 225 280 2×168 2×185

Power supply / 380V-3Ph-50Hz


Start current A <192.2 <242.2 <302.2 <350.1 <411.1 <474 <563.1 <668.9 <720.8

Rated current A 201.9 259.5 319.5 372.5 425.3 502.9 583.6 717.7
Max. operating current A 277.2 347.5 443.4 502.4 603.6 690.6 827.7 972.5 1054.5
Start current A <201.9 <259.5 <319.5 <372.5 <425.3 <502.9 <583.6 <717.7
Type / Fin-coil
Max. operating current A 293.0 377.1 466.5 539.0 611.6 720.2 845.6 1048.6
Air side heat exchanger No. of fan / 6 8 10 12 14 16 18 20 20
Type / Fin-coil
Moter power input kW 2.0
Air side heat exchanger No. of fan / 8 8 10 12 14 16 18 20
Type / Shell and tube
Motor power input kW 2.5
Water flow m /h
3 68.3 86.1 106.3 124.5 144.2 166.1 199.2 235.2 249.1
Type / Shell and tube
Water side heat exchanger Water side pressure drop kPa 47 53 73 68 75 67 74 74 73
Water flow m3/h 68.3 86.1 106.3 124.5 144.2 166.1 199.2 239.2

Water pipe connection mm DN150 DN150 DN150 DN150 DN150 DN200 DN200 DN200 DN200
Water side pressure drop kPa 54 63 85 81 88 79 89 91
Water side heat exchanger
Max. working pressure MPa 1.0
Pressure drop (free cooling is on) kPa 98 137 161 131 143 151 198 242

Length mm 4440 5240 6245 7250 8255 9260 10265 11270 11270 Water pipe connection mm DN150 DN150 DN150 DN150 DN150 DN200 DN200 DN200

Unit dimensions Width mm 2300 2300 2300 2300 2300 2300 2300 2300 2300 Max. working pressure MPa 1.0

Height mm 2460 2460 2460 2460 2460 2460 2460 2460 2460 Length mm 5240 5240 6245 7250 8255 9260 10265 11270

Unit weight kg 4240 4950 5500 6170 7050 7620 9800 10940 10980 Unit dimensions Width mm 2300 2300 2300 2300 2300 2300 2300 2300

Operating weight kg 4440 5150 5720 6410 7330 7960 10160 11320 11380 Height mm 2460 2460 2460 2460 2460 2460 2460 2460

Note: Note:
1. Cooling: outdoor ambient temperature: 35°C, chilled water inlet/outlet: 12°C/7°C, fouling factor: 0.018m2. °C/kW. 1. Nominal parameter refers to the following conditions: outdoor ambient temperature=35°C, chilled water inlet/outlet=12°C/7°C, fouling factor=0.018m2. °C/kW.
2. IPLV calculations according to standard performances (in accordance with AHRI 550/590). 2. Free cooling parameter refers to the following conditions: outdoor ambient temperature=ambient temperature of free cooling only; chilled water inlet/outlet=15°C/10°C,
3. As a result of the continuous improvement of the product, the above parameters may be changed, please refer to the product nameplate and in-kind. fouling factor=0.018m2. °C/kW
3. IPLV calculations according to standard performances (in accordance with AHRI 550/590).
4. As a result of the continuous improvement of the product, the above parameters may be changed, please refer to the product nameplate and in-kind.

09 10
460V-3Ph-60Hz

380V-3Ph-50Hz T1 series, WDAT-CN***H22V Model 115 140 175 205 245 285 330 385 415

Indirect free cooling series, WDAT-CN***HV(FC-I) Model 115 140 175 205 245 285 330 400 T3 series, WDAT-CN***H22V(T3) Model 115 140 175 205 245 285 330 385 415
All year round cooling series,
Cooling capacity kW 397.1 500.6 618.1 723.8 838.4 965.6 1158.1 1390.9 WDAT-CN***H22V(LA) Model 115 140 175 205 245 285 330 385 415

Power input kW 121.4 156.4 192.0 224.8 254.8 300.8 352.0 434.7 Cooling capacity kW(Ton) 397.1(112.9) 500.6(142.4) 618.1(175.8) 723.8(205.9) 838.4(238.5) 965.6(274.6) 1158.1(329.4) 1367.6(389.0) 1448.4(411.9)
Nominal parameter
Cooling COP kW/kW 3.27 3.20 3.22 3.22 3.29 3.21 3.29 3.20 Power input kW 116.5 145.9 181.3 212.3 245.9 284.0 339.6 402.2 426.0
Nominal
parameter kW/kW
IPLV kW/kW 4.57 4.53 4.52 4.54 4.58 4.51 4.53 4.52 Cooling COP 3.41(1.03) 3.43(1.03) 3.41(1.03) 3.41(1.03) 3.41(1.03) 3.4(1.03) 3.41(1.03) 3.40(1.03) 3.40(1.03)
(kW/Ton)

Cooling capacity kW 397.1 500.6 618.1 723.8 838.4 965.6 1158.1 1390.9 kW/kW
IPLV (kW/Ton) 4.91(0.72) 4.98(0.71) 5.03(0.70) 5.02(0.70) 5.03(0.70) 5.01(0.70) 4.93(0.71) 5.03(0.70) 5.01(0.70)
Free cooling only parameter Power input kW 26.2 28.0 31.0 34.5 36.5 38.0 47.0 54.0 Semi-hermetic twin-rotor screw compressor
Type /
Compressor
COP kW/kW 15.16 17.88 19.94 20.98 22.97 25.41 24.64 25.76
Quantity / 1 1 1 1 1 1 2 2 2
Specifications

Specifications
Ambient temperature of free cooling only °C -0.54 -0.25 -0.19 0.05 0.03 0.07 -0.41 -0.81
Energy regulation mode / Stepless control (Single compressor 10%-100% , Dual compressor 5%-100%)

Free cooling only heat exchange temperature difference °C 10.54 10.25 10.19 9.95 9.97 9.93 10.41 10.81
Type / R134a
Refrigerant
Type / Semi-hermetic twin-rotor screw compressor
Compressor Charge amount kg(lb) 126(278) 148(326) 168(370) 192(423) 225(496) 280(617) 2×168(2×370)2×185(2×408)2×200(2×441)
Quantity / 1 1 1 1 1 1 2 2
Power supply / 460V-3Ph-60Hz
Energy regulation mode / Stepless control (Single compressor 10%-100% , Dual compressor 5%-100%)
Rated current A 158.8 200.1 249.6 289.2 339.6 391.6 465.2 552.6 595.4
Type / R134a
Start current A <158.8 <200.1 <249.6 <289.2 <339.6 <391.6 <465.2 <552.6 <595.4
Refrigerant Charge amount kg 126 148 168 192 225 280 2×168 2×185
Max. operating current A 229.0 287.1 366.3 415.0 498.6 570.5 683.8 803.4 871.1
Power supply / 380V-3Ph-50Hz
Type / Fin-coil
Rated current A 201.9 259.5 319.5 372.5 425.3 502.9 583.6 717.7 Air side heat
exchanger No. of fan / 6 8 10 12 14 16 18 20 20
Start current A 201.9 259.5 319.5 372.5 425.3 502.9 583.6 717.7
Moter
kW 2.0
power input
Max. operating current A 293.0 377.1 466.5 539.0 611.6 720.2 845.6 1048.6
Type / Shell and tube
Type / Fin-coil

Water flow m3/h(GPM) 68.3(250) 86.1(316) 106.3(390) 124.5(456) 144.2(529) 166.1(609) 199.2(730) 235.2(862) 249.1(913)
Air side heat exchanger No. of fan / 8 8 10 12 14 16 18 20
Water side heat Water side
exchanger pressure drop kPa(ftH2O) 47(15.7) 53(17.7) 73(24.4) 68(22.7) 75(25.1) 67(22.4) 74(24.8) 74(24.8) 73(24.4)
Motor power input kW 2.5
Water pipe
Shell and tube connection mm(in) 150(5.9) 150(5.9) 150(5.9) 150(5.9) 150(5.9) 200(7.9) 200(7.9) 200(7.9) 200(7.9)
Type /
Max. working
MPa 1.0
Water flow m3/h 68.3 86.1 106.3 124.5 144.2 166.1 199.2 239.2 pressure

Water side heat exchanger Length mm(in) 4440(174.8) 5240(206.3) 6245(245.9) 7250(285.4) 8255(325.0) 9260(364.6) 10265(404.1) 11270(443.7) 11270(443.7)
Pressure drop kPa 77 88 114 115 132 134 143 155
Unit dimensions Width mm(in) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6)
Water pipe connection mm DN150 DN150 DN150 DN150 DN150 DN200 DN200 DN200

Height mm(in) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9)
Max. working pressure MPa 1.0

Unit weight kg(lb) 4240(9348) 4950(10913) 5500(12125) 6170(13603) 7050(15543) 7620(16799) 9800(21605) 10940(24119) 10980(24207)
Length mm 6245 6245 6245 7250 8255 9260 10265 11270

Unit dimensions Width mm 2300 2300 2300 2300 2300 2300 2300 2300 Operating weight kg(lb) 4440(9789) 5150(11354) 5720(12610) 6410(14132) 7330(16160) 7960(17549) 10160(22399) 11320(24956) 11380(25089)

Height mm 2460 2460 2460 2460 2460 2460 2460 2460 Note:
1. Cooling: outdoor ambient temperature: 35°C, chilled water inlet/outlet: 12°C/7°C, fouling factor: 0.018m2. °C/kW.
Note: 2. IPLV calculations according to standard performances (in accordance with AHRI 550/590).
1. Nominal parameter refers to the following conditions: outdoor ambient temperature=35°C, chilled water inlet/outlet=12°C/7°C, fouling factor=0.018m2. °C/kW. 3. As a result of the continuous improvement of the product, the above parameters may be changed, please refer to the product nameplate and in-kind.
2. Free cooling parameter refers to the following conditions: outdoor ambient temperature=ambient temperature of free cooling only; chilled water inlet/outlet=12°C/7°C,
fouling factor=0.018m2. °C/kW
3. IPLV calculations according to standard performances (in accordance with AHRI 550/590).
4. As a result of the continuous improvement of the product, the above parameters may be changed, please refer to the product nameplate and in-kind.

11 12
460V-3Ph-60Hz 460V-3Ph-60Hz
Direct free cooling series, Indirect free cooling series,
WDAT-CN***H22V(FC-D) Model 115 140 175 205 245 285 330 400 WDAT-CN***H22V(FC-I) Model 115 140 175 205 245 285 330 400

Cooling capacity kW(Ton) 397.1(112.9) 500.6(142.4) 618.1(175.8) 723.8(205.9) 838.4(238.5) 965.6(274.6) 1158.1(329.4) 1390.9(395.6) Cooling capacity kW(Ton) 397.1(112.9) 500.6(142.4) 618.1(175.8) 723.8(205.9) 838.4(238.5) 965.6(274.6) 1158.1(329.4) 1390.9(395.6)

Power input kW 121.4 156.4 192.0 224.8 254.8 300.8 352.0 434.7 Power input kW 121.4 156.4 192.0 224.8 254.8 300.8 352.0 434.7
Nominal parameter Nominal parameter
kW/kW kW/kW
Cooling COP (kW/Ton) 3.27(1.08) 3.20(1.10) 3.22(1.09) 3.22(1.09) 3.29(1.07) 3.21(1.10) 3.29(1.07) 3.20(1.10)
Cooling COP (kW/Ton) 3.27(1.08) 3.20(1.10) 3.22(1.09) 3.22(1.09) 3.29(1.07) 3.21(1.10) 3.29(1.07) 3.20(1.10)
kW/kW
IPLV 4.57(0.77) 4.53(0.78) 4.52(0.78) 4.54(0.77) 4.58(0.77) 4.51(0.78) 4.53(0.78) 4.52(0.78) kW/kW
(kW/Ton) IPLV 4.57(0.77) 4.53(0.78) 4.52(0.78) 4.54(0.77) 4.58(0.77) 4.51(0.78) 4.53(0.78) 4.52(0.78)
(kW/Ton)
Cooling capacity kW(Ton) 397.1(112.9) 500.6(142.4) 618.1(175.8) 723.8(205.9) 838.4(238.5) 965.6(274.6) 1158.1(329.4) 1390.9(395.6)
Cooling capacity kW(Ton) 397.1(112.9) 500.6(142.4) 618.1(175.8) 723.8(205.9) 838.4(238.5) 965.6(274.6) 1158.1(329.4) 1390.9(395.6)
Free cooling
only parameter Power input kW 19.6 19.6 24.5 29.4 34.3 39.2 44.1 49.0 Free cooling
only parameter Power input kW 26.2 28.0 31.0 34.5 36.5 38.0 47.0 54.0
kW/kW
COP 20.26(0.17) 25.54(0.14) 25.23(0.14) 24.62(0.14) 24.44(0.14) 24.63(0.14) 26.26(0.13) 28.39(0.12) kW/kW
(kW/Ton) COP 15.16(0.23) 17.88(0.20) 19.94(0.18) 20.98(0.17) 22.97(0.15) 25.41(0.14) 24.64(0.14) 25.76(0.14)
(kW/Ton)
Ambient temperature of free
cooling only °C 2.37 2.79 2.87 3.05 3.10 3.04 2.58 1.98 Ambient temperature of
free cooling only °C -0.54 -0.25 -0.19 0.05 0.03 0.07 -0.41 -0.81
Free cooling only heat exchange
Specifications

Specifications
°C 7.63 7.21 7.13 6.95 6.90 6.96 7.42 8.02 Free cooling only heat exchange
temperature difference
temperature difference °C 10.54 10.25 10.19 9.95 9.97 9.93 10.41 10.81
Type / Stepless control (Single compressor 10%-100% , Dual compressor 5%-100%)
Compressor Type / Stepless control (Single compressor 10%-100% , Dual compressor 5%-100%)
Quantity / 1 1 1 1 1 1 2 2 Compressor
Quantity / 1 1 1 1 1 1 2 2
Energy regulation mode / Single compressor 10%-100% , Dual compressor 5%-100%
Energy regulation mode / Single compressor 10%-100% , Dual compressor 5%-100%
Type / R134a R134a R134a R134a R134a R134a R134a R134a
Refrigerant
Type / R134a R134a R134a R134a R134a R134a R134a R134a
Charge amount kg(lb) 126(278) 148(326) 168(370) 192(423) 225(496) 280(617) 2×168(2×370) 2×185(2×408) Refrigerant
Charge amount kg 126(278) 148(326) 168(370) 192(423) 225(496) 280(617) 2×168(2×370) 2×185(2×408)
Power supply / 460V-3Ph-60Hz
Power supply / 460V-3Ph-60Hz
Rated current A 166.8 214.4 263.9 307.7 351.3 415.4 482.1 592.9
Rated current A 166.8 214.4 263.9 307.7 351.3 415.4 482.1 592.9
Start current A <166.8 <214.4 <263.9 <307.7 <351.3 <415.4 <482.1 <592.9
Start current A <166.8 <214.4 <263.9 <307.7 <351.3 <415.4 <482.1 <592.9
Max. operating current A 242.0 311.5 385.4 445.3 505.2 594.9 698.5 866.2
Max. operating current A 242.0 311.5 385.4 445.3 505.2 594.9 698.5 866.2
Type / Fin-coil
Type / Fin-coil
Air side heat No. of fan / 8 8 10 12 14 16 18 20 Air side heat
exchanger No. of fan / 8 8 10 12 14 16 18 20
exchanger
Motor power input kW 2.5
Motor power input kW 2.5
Type / Shell and tube
Type / Shell and tube
Water flow m3/h(GPM) 68.3(250) 86.1(316) 106.3(390) 124.5(456) 144.2(529) 166.1(609) 199.2(730) 239.2(877)
Water side Water flow m3/h(GPM) 68.3(250) 86.1(316) 106.3(390) 124.5(456) 144.2(529) 166.1(609) 199.2(730) 239.2(877)
Water side heat pressure drop kPa(ftH2O) 54(18.1) 63(21.1) 85(28.4) 81(27.1) 88(29.4) 79(26.4) 89(29.8) 91(30.4) Water side
exchanger heat exchanger
Pressure drop Pressure drop kPa(ftH2O) 77(25.8) 88(29.4) 114(38.1) 115(38.5) 132(44.2) 134(44.8) 143(47.8) 155(51.9)
(free cooling is on) kPa(ftH2O) 98(32.8) 137(45.8) 161(53.9) 131(43.8) 143(47.8) 151(50.5) 198(66.2) 242(81.0)
Water pipe
Water pipe connection mm(in) 150(5.9) 150(5.9) 150(5.9) 150(5.9) 150(5.9) 200(7.9) 200(7.9) 200(7.9)
mm(in) 150(5.9) 150(5.9) 150(5.9) 150(5.9) 150(5.9) 200(7.9) 200(7.9) 200(7.9)
connection
Max. working
Max. working MPa 1.0
MPa 1.0 pressure
pressure

Length mm(in) 5240(206.3) 5240(206.3) 6245(245.9) 7250(285.3) 8255(325.0) 9260(364.6) 10265(404.1) 11270(443.7) Length mm(in) 6245(245.9) 6245(245.9) 6245(245.9) 7250(285.4) 8255(325.0) 9260(364.6) 10265(404.1) 11270(443.7)

Unit dimensions Width mm(in) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) Unit dimensions Width mm(in) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6) 2300(90.6)

Height mm(in) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) Height mm(in) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9) 2460(96.9)

Note: Note:
1. Nominal parameter refers to the following conditions: outdoor ambient temperature=35°C, chilled water inlet/outlet=12°C/7°C, fouling factor=0.018m2. °C/kW. 1. Nominal parameter refers to the following conditions: outdoor ambient temperature=35°C, chilled water inlet/outlet=12°C/7°C, fouling factor=0.018m2. °C/kW.
2. Free cooling parameter refers to the following conditions: outdoor ambient temperature=ambient temperature of free cooling only; 2. Free cooling parameter refers to the following conditions: outdoor ambient temperature=ambient temperature of free cooling only;
chilled water inlet/outlet=15°C/10°C, fouling factor=0.018m2. °C/kW chilled water inlet/outlet=12°C/7°C, fouling factor=0.018m2. °C/kW
3. IPLV calculations according to standard performances (in accordance with AHRI 550/590). 3. IPLV calculations according to standard performances (in accordance with AHRI 550/590).
4. As a result of the continuous improvement of the product, the above parameters may be changed, please refer to the product nameplate and in-kind. 4. As a result of the continuous improvement of the product, the above parameters may be changed, please refer to the product nameplate and in-kind.

13 14
Dimensions and base diagrams
DIMENSIONS
1 BASE DIAGRAMS

2
150 150
150

① Chilled water outlet


② Chilled water inlet ⑥ Installation foundation 6
③ Control panel ⑦ Spring isolator installation hole
④ VFD 3 ⑧ Electric control box
⑤ Power incoming line 6-φ14
4 7

150
8
5
Dimensions (unit: mm)
Dimensions (unit: mm)
Model, WDAT-CN A B C D E F
Model, WDAT-CN A B C D E F G 115.1HV, 115.1HV(T3), 115.1HV(LA)
115.1HV, 115.1HV(T3), 115.1HV(LA) 115.1H22V, 115.1H22V(T3), 115.1H22V(LA) 4440 2300 2180 600 1670 1200
4440 2300 2460 420 550 260 60 140.1HV, 140.1HV(T3), 140.1HV(LA)
115.1H22V, 115.1H22V(T3), 115.1H22V(LA) 5445 2300 2180 800 2000 1700
140.1HV, 140.1HV(T3), 140.1HV(LA) 140.1H22V, 140.1H22V(T3), 140.1H22V(LA)
5240 2300 2460 420 550 260 65
140.1H22V, 140.1H22V(T3), 140.1H22V(LA)
Dimensions and

Dimensions and
base diagrams

base diagrams
175.1HV, 175.1HV(T3), 175.1HV(LA)
6245 2300 2460 420 550 260 405 Spring isolator at all points
175.1H22V, 175.1H22V(T3), 175.1H22V(LA)
205.1HV, 205.1HV(T3), 205.1HV(LA) Model, WDAT-CN P1 P2 P3
7250 2300 2460 420 550 260 1300
205.1H22V, 205.1H22V(T3), 205.1H22V(LA)
245.1HV, 245.1HV(T3), 245.1HV(LA) 115.1HV, 115.1HV(T3), 115.1HV(LA)
8255 2300 2460 420 550 260 2305 115.1H22V, 115.1H22V(T3), 115.1H22V(LA) MHD-850 MHD-850 MHD-850
245.1H22V, 245.1H22V(T3), 245.1H22V(LA) 140.1HV, 140.1HV(T3), 140.1HV(LA)
285.1HV, 285.1HV(T3), 285.1HV(LA) 140.1H22V, 140.1H22V(T3), 140.1H22V(LA) MHD-1050 MHD-1050 MHD-1050
9260 2300 2460 420 550 300 3310
285.1H22V, 285.1H22V(T3), 285.1H22V(LA)
Note:
1. The spring isolator is optional.
2. The value in the spring isolator model indicates the bearable weight (unit: kg). For example, "1050" in "MHD-1050" indicates 1050kg.
1

150 150
150

6
5 ⑥ Installation foundation
5 4 4
⑦ Spring isolator installation hole
⑧ Electric control box
8-φ14
3 7

150
8

① Chilled water outlet


② Chilled water inlet Dimensions (unit: mm)
③ Control panel
Model, WDAT-CN A B C D E F G
④ VFD
175.1HV, 175.1HV(T3), 175.1HV(LA)
⑤ Power incoming line 175.1H22V, 175.1H22V(T3), 175.1H22V(LA) 6245 2300 2180 1080 2000 1200 1200

Dimensions (unit: mm) Spring isolator at all points

Model, WDAT-CN P1 P2 P3 P4
Model, WDAT-CN A B C D E F G 175.1HV, 175.1HV(T3), 175.1HV(LA)
175.1H22V, 175.1H22V(T3), 175.1H22V(LA) MHD-850 MHD-850 MHD-850 MHD-850
330.2HV, 330.2HV(T3), 330.2HV(LA)
Note:
330.2H22V, 330.2H22V(T3), 330.2H22V(LA) 10265 2300 2460 410 550 350 3965
1. The spring isolator is optional.
385.2HV, 385.2HV(T3), 385.2HV(LA) 2. The value in the spring isolator model indicates the bearable weight (unit: kg). For example, "1050" in "MHD-1050" indicates 1050kg.
385.2H22V, 385.2H22V(T3), 385.2H22V(LA) 11270 2300 2460 410 550 350 4970

415.2HV, 415.2HV(T3), 415.2HV(LA)


415.2H22V, 415.2H22V(T3), 415.2H22V(LA) 11270 2300 2460 410 550 350 4970

15 16
150
150 150
150 150
150

⑥ Installation foundation 6
⑥ Installation foundation
6 ⑦ Spring isolator installation hole
⑦ Spring isolator installation hole
⑧ Electric control box ⑧ Electric control box
12-φ14
7
12-φ14
7

150 8

150 8

Dimensions (unit: mm)


Dimensions (unit: mm)
Model, WDAT-CN A B C D E F G H I
Model, WDAT-CN A B C D E F G H
285.1HV, 285.1HV(T3), 285.1HV(LA)
205.1HV, 205.1HV(T3), 205.1HV(LA) 285.1H22V, 285.1H22V(T3), 285.1H22V(LA) 9260 2300 2180 845 1800 1800 1800 1050 1200
205.1H22V, 205.1H22V(T3), 205.1H22V(LA) 7250 2300 2180 635 1800 1800 1050 1200

Spring isolator at all points Spring isolator at all points

Model, WDAT-CN P1 P2 P3 P4 P5 P6 Model, WDAT-CN P1 P2 P3 P4 P5 P6


205.1HV, 205.1HV(T3), 205.1HV(LA) 285.1HV, 285.1HV(T3), 285.1HV(LA)
MHD-850 MHD-850 MHD-850 MHD-850 MHD-850 MHD-850 285.1H22V, 285.1H22V(T3), 285.1H22V(LA) MHD-850 MHD-850 MHD-850 MHD-850 MHD-850 MHD-850
205.1H22V, 205.1H22V(T3), 205.1H22V(LA)

Note: Note:
1. The spring isolator is optional. 1. The spring isolator is optional.
2. The value in the spring isolator model indicates the bearable weight (unit: kg). For example, "1050" in "MHD-1050" indicates 1050kg.
Dimensions and

Dimensions and
2. The value in the spring isolator model indicates the bearable weight (unit: kg). For example, "1050" in "MHD-1050" indicates 1050kg.
base diagrams

base diagrams
150
150
150
150
150
150

⑥ Installation foundation 6 6

⑦ Spring isolator installation hole


⑧ Electric control box
12-φ14
12-φ14
7 ⑥ Installation foundation 7

⑦ Spring isolator installation hole

150 8 ⑧ Electric control box


150 8

Dimensions (unit: mm) Dimensions (unit: mm)

Model, WDAT-CN A B C D E F G H I Model, WDAT-CN A B C D E F G H I


245.1HV, 245.1HV(T3), 245.1HV(LA) 330.2HV, 330.2HV(T3), 330.2HV(LA)
245.1H22V, 245.1H22V(T3), 245.1H22V(LA) 8255 2300 2180 440 1200 1800 1800 1050 1200 330.2H22V, 330.2H22V(T3), 330.2H22V(LA) 10265 2300 2180 1100 2000 2000 2000 1200 1200

Spring isolator at all points Spring isolator at all pionts

Model, WDAT-CN P1 P2 P3 P4 P5 P6 Model, WDAT-CN P1 P2 P3 P4 P5 P6


245.1HV, 245.1HV(T3), 245.1HV(LA) 330.2HV, 330.2HV(T3), 330.2HV(LA)
245.1H22V, 245.1H22V(T3), 245.1H22V(LA) MHD-850 MHD-850 MHD-850 MHD-850 MHD-850 MHD-850 330.2H22V, 330.2H22V(T3), 330.2H22V(LA) MHD-1050 MHD-1050 MHD-1050 MHD-1050 MHD-1050 MHD-1050

Note: Note:
1. The spring isolator is optional.
1. The spring isolator is optional.
2. The value in the spring isolator model indicates the bearable weight (unit: kg). For example, "1050" in "MHD-1050" indicates 1050kg.
2. The value in the spring isolator model indicates the bearable weight (unit: kg). For example, "1050" in "MHD-1050" indicates 1050kg.

17 18
150
150 Installation and maintenance
150

6
⑥ Installation foundation Single installation
⑦ Spring isolator installation hole
⑧ Electric control box 14-φ14
7

0
150
150 8

150
Dimensions (unit: mm) 0

Model, WDAT-CN A B C D E F G H I J
385.2HV, 385.2HV(T3), 385.2HV(LA)
385.2H22V, 385.2H22V(T3), 385.2H22V(LA) 11270 2300 2180 405 1700 2000 2000 2000 1200 1200
150 0
415.2HV, 415.2HV(T3), 415.2HV(LA) 0 150
415.2H22V, 415.2H22V(T3), 415.2H22V(LA) 11270 2300 2180 405 1700 2000 2000 2000 1200 1200

Spring isolator at all points

Model, WDAT-CN P1 P2 P3 P4 P5 P6 P7
385.2HV, 385.2HV(T3), 385.2HV(LA)
385.2H22V, 385.2H22V(T3), 385.2H22V(LA) MHD-1050 MHD-1050 MHD-1050 MHD-1050 MHD-1050 MHD-1050 MHD-1050
415.2HV, 415.2HV(T3), 415.2HV(LA)
415.2H22V, 415.2H22V(T3), 415.2H22V(LA) MHD-1050 MHD-1050 MHD-1050 MHD-1050 MHD-1050 MHD-1050 MHD-1050 Series connection
Dimensions and
base diagrams

Note:
1. The spring isolator is optional.
2. The value in the spring isolator model indicates the bearable weight (unit: kg). For example, "1050" in "MHD-1050" indicates 1050kg.
0
150

0
100
150

Installation and
0

maintenance
150
0 0
150

Parallel connection

150
0 0
150

150
0

150 0
0 150

19 20
Cl
i
vet

Cl
i
vet
Intelligent management
CLIVET CHILLER PLANT CONTROL CLIVET SMART CLOUD PLATFORM

Clivet Chiller Plant Control is a group control system for commercial air conditioning that includes air conditioners, water pumps,
cooling towers, terminals and related ancillary equipment (including valves, sensors etc.) as the underlying control objects. Based on Clivet has built a flawless internet-based remote monitoring system, which
a powerful control logic program and communication network, it establishes a 3-layer control framework that integrates the equip-
ment, control and management layers. Clivet Chiller Plant Control contains a unique operation module from Clivet that is designed
Clivet provides customers with outstanding cloud service via advanced cloud service
technologies and the internet. Customers can connect Clivet air conditioner to
to save energy, so in addition to automated stable operations for the various devices, this product also improves and optimizes user the global remote monitoring system through Clivet's IMU smart data acquisi-
management capabilities, reduces labour costs, boosts operational efficiency and lowers the overall energy consumption for tion terminal, so that professionals can help the customer to implement remote
commercial air conditioning. fault diagnosis, analysis and receive early warning alarms for failures, ensuring the equipment's optimal operation. Customers
authorized by Clivet can use a Web browser to view the real-time monitoring data of the air conditioning system.

Web client BMS Server


LAN/WAN
Management layer

1 "Clivet Smart Cloud" remote Internet monitoring service

BACnet IP
2 Cloud data storage

(CCM21 cloud
platform module)
3 Working condition data analysis

Chiller group Terminal group Control layer


4 Quick fault diagnosis
control panel control panel

Clivet or 3rd-party chiller


5 Viewing monitoring data through the Web browser

Network fan coil thermostat

QUICKVIEW
3rd-party equipment

Clivet's QuickView smart software control system is a type of smart software specially developed by Clivet. It features high real-time
DC controller for modular AHU efficiency, stability, reliability, a high degree of visualization and strong scalability. It can implement a wide variety of scenarios such as
Equipment layer real-time data monitoring of units, unit equipment management, remote control, curve display, data storage, alarm query, fault
diagnosis, uploading data to the cloud and external data analysis, greatly improving the unit's operation management efficiency and
3rd-party instrument reducing the human input and operation and maintenance costs.

3rd-party instrument

Y
No.1
Control segment of the equipment room Terminal control segment X
Intelligent management

Intelligent management
Y
No.2
X

Y

X

Max. 600m
Y
No.100
X

Chillers

23 24
Reference projects

Mozambique Capital Airport


Country: Mozambique
City: Maputo
Total Capacity: 4,000 RT
Outdoor Unit: Air cooled screw chiller & DC Inverter VRF
Indoor Unit: FCU & AHU
Reference projects

Reference projects
Completion Year: 2012

25 26
Shenzhen North Railway Station
Country: China
City: Shenzhen
Total Capacity: 2,842 RT
Outdoor Unit: Air cooled screw chiller & DC Inverter VRF
Indoor Unit: MAHU & AHU & FCU
Completion Year: 2012
Reference projects

Reference projects
27 28
Sheraton Bandara Resort Hotel (Five Star) Rize Hospital (400 Beds)
Country: Indonesia Country: Turkey
City: Jakarta City: Rize
Total Capacity: 1,050 RT Total Capacity: 340 RT
Outdoor Unit: Air cooled screw chiller Outdoor Unit: Air cooled screw chiller
Indoor Unit: FCU Indoor Unit: FCU & Fresh Air Processing
Completion Year: 2011 Completion Year: 2010
Reference projects

Reference projects
29 30
Hub Power Station Sarab Community Market
Country: Pakistan Country: UAE
City: Balochistan City: Abu Dhabi
Outdoor Units: Tropical air cooled screw chiller Outdoor Units: Air cooled screw chiller
Total Capacity: 1,024 RT Indoor Units: AHU
Total Capacity: 1,137 RT

Renaissance Hotel (Five Star) Indoor Stadium Huamark


Country: Thailand Country: Thailand
City: Pattaya City: Bangkok
Total Capacity: 512 RT Outdoor Units: Air cooled screw chiller
Reference projects

Reference projects
Outdoor Units: Air cooled screw chiller Indoor Units: AHU
Indoor Units: AHU Total Capacity: 8,800 kW
Completion Year: 2017

31 32