Technical Data Sheet

CapaFilex
Water Based Acrylic Co-Polymer Repairing Filler/Equalizer For Facades
For Exterior

Page 1 of 3

Product Description
CapaFilex is a water based Acrylic Co-Polymer filler for exterior surface with excellent working properties for repairing of
small, minor defects and unevenness in renders/plasters and concrete. CapaFilex is ideal for external filling with less
shrinkage and easy to apply. Suitable for use on full (seamless) surfaces and for levelling and equalizing unevenly textured
fine render/plaster coatings or concrete. CapaFilex cannot be use for EIFS/ETICS. Maximum coating/layer thickness per
work step: 0.5 mm

Recommended Use
Ideal for Interior & Exterior Elevations. CapaFilex is recommended as filler for finishing top- coats

Physical Properties

VOC In compliance with Dubai Green Building Regulations-Dubai Municipality


Thinner/Cleaner Potable clean water
Finish Semi- Matt, Satin, and Gloss
Packing size 5 & 30 kg
Shelf life 24 months
*Product can be tinted on CAPAROL tinting express system and made available instantly. Tinting may cause variations in the technical characteristics.

Film Thickness and Spreading Rate

Dry film thickness Wet film thickness Theoretical spreading rate


100- 500 µm 160 - 805 µm 8.5 – 10.5 m²/litre

*Spreading rates are indicative per coat, due allowance and wastage factor should be considered in practical application. This indication does not take into
account usage for spilling or loss on site. The figure may also vary according to substrate or application conditions. The exact rate of consumption for your
particular project is best established by a trial application on site and executed by your desired applicator.

Drying Time

Substrate temperature 10°C 25°C 40°C


Touch dry 4 2 1 h
Dry to over coat 12 6 3 h
Ready for stress 96 48 24 h

*The material cures physically by evaporation of water. Drying time generally related to air circulation, temperature, film thickness, no of coats and relative
humidity. The given data must be considered as guidelines per coat only. The actual drying time before recoating may be shorter or longer, depending on
film thickness, ventilation, humidity, underlying paint system, requirement for early handling and mechanical strength etc. The figures given are typical
with: Good ventilation (outdoor exposure or free circulation of air), typical film thickness, on coat on top of inert substrate and relative humidity 70%.

Technical Information No. F 1 – Issue: January 2022


All suggestions and application instructions herein are based on our latest technical experience.

Caparol Paints L.L.C. - Saih Shuaib 4, Dubai Industrial Park, P.O. Box: 62182, Dubai, UAE, Tel: +971 43687600, Fax: +971 43687650 - www.caparolarabia.com
Technical Data Sheet
CapaFilex
Water Based Acrylic Co-Polymer Repairing Filler/Equalizer For Facades
For Exterior

Page 2 of 3

Guiding data for airless spray equipment

Spraying angle: 50°- 80°


Nozzle size: 0.018” - 0.026"
Pressure: 150 - 180 bars

*The spray details given above are intended as a guide only, fluid hose length, diameter, paint temperature and project complexity all influence the choice
of tip and operating pressure. Always check to ensure that filter is clean.

Surface Preparation

The substrate must be even, clean, dry, solid, sound/stable, and free from all substances that may prevent adhesion.
Remove unsound coatings of enamels, dispersion paints, synthetic renders/plasters and unsound mineral paint coatings.
Clean sound, adherent paint coatings dry or wet. Clean surfaces with organic growth (moss, algae and mild) by high
pressure water jet in compliance with the regulations. Clean surfaces soiled with industrial gases or soot by high pressure
water jet and suitable cleaners in compliance with the regulations. Adjust the substrate evenness of the planned, finer
surface finish. If necessary, carry out additional substrate levelling measures. Check existing coatings for their load-bearing
capacity. Remove any non-load bearing or structurally weak coatings. Any damaged areas or surface irregularities should be
repaired before application. Repairs must be well set and dried out. Damp or not fully cured substrates can lead to defects
in subsequent coats, such as blistering or cracks. It is most important that substrates are correctly prepared prior to
application of paint.

Mixing Paint

Amphibolin is single component water based product, should be mixed properly before application. The material can be
diluted with potable clean water only. Stir Amphibolin with a low-speed stainless steel agitator. Do not use mixers made of
aluminium - danger of discolouration. Use as little water as possible to achieve application consistency. Stir well before
application. For airless spraying the amount of water added depends on the requirement of the airless machine. If
necessary adjust to working consistency with tap water up to max. 10 %. Ensure short stirring times at low speed to prevent
foam formation in the binding agent. Foam formation can have an impact on wet adhesion with significantly lower
consumption, and hence due to the lower paint density, can cause the substrate to shine through. This, in turn, leads to
patchy and inhomogeneous drying of the render layer. As a rule, in case of strong colour shades less water needs to be
added to achieve the optimum application consistency. Diluting the material too much will make application more difficult
and will result in poorer characteristics (e.g. hiding power, colour shade). It´s strongly recommend to use the thinned paint
in same shift and not to store for next day as there are might chances of paint losing its characteristic’s, settling, formation
and chances of bacterial contamination from external sources. Hence recommended to estimate paint required for the shift
and mix accordingly to avoid any problems.

Application Conditions

Substrate temperature should be min.5°C and at least 3°C above the dew point of the air. Suitable processing temperature
should between + 5 °C to approx. 40 °C for material, substrate, water and ambient air during application and curing.
At application below 10°C drying temperature will be significantly extended and spraying characteristics may be impaired.
Paint to be applied to suitable primed surface. Do not apply during strong wind, fog, high relative humidity, and or frost. Do
not apply or leave to dry in direct sunlight as this can lead to differences in gloss levels and even to slight cloudiness.

Technical Information No. F 1 – Issue: January 2022


All suggestions and application instructions herein are based on our latest technical experience.

Caparol Paints L.L.C. - Saih Shuaib 4, Dubai Industrial Park, P.O. Box: 62182, Dubai, UAE, Tel: +971 43687600, Fax: +971 43687650 - www.caparolarabia.com
Technical Data Sheet
CapaFilex
Water Based Acrylic Co-Polymer Repairing Filler/Equalizer For Facades
For Exterior

Page 3 of 3

Storage and Handling

24 months when stored in warehouse conditions below 35°C in the original, unopened packs. The product must be kept in
in cool, dry well ventilated space and away from source of heat and ignition. Containers must be kept tightly closed and
always handle with care. Keep out of reach of children.

Health and Safety

Always ensure good ventilation during application and drying. Do not eat, drink or smoke while using the product. Do not
breathe vapors or spray when applying paint indoor by spray, wear proper air supplied breathing equipment’s. Respiratory
equipment’s must be suitable for the purpose and meet appropriates standards. When applying paint, it is advisable to
wear suitable eye protection, in case contact with eyes, rinse immediately with plenty of water and seek medical advice.
Remove splashes from skin, use soap and water or recognized skin cleaner. Do not use or store by hanging on a hook.
Materials and all related packaging must be disposed of in a safe way in accordance with the full requirements of the local
authorities. Do not allow product to enter into wadis, waterways, drains, watercourses and soil. Only completely emptied
containers should be given for recycling. Material safety data sheet (MSDS) available on request.

Disclaimer

The information provided in this technical data sheet is based on tests conducted in laboratories and practical experience.
Caparol’s products are often used in indecent conditions which is beyond Caparol’s control, and hence Caparol cannot
guarantee anything but the products quality.

We recommend to consult Caparol for guidance on applications in order to ensure suitability and the products
performance.

Technical Information No. F 1 – Issue: January 2022


All suggestions and application instructions herein are based on our latest technical experience.

Caparol Paints L.L.C. - Saih Shuaib 4, Dubai Industrial Park, P.O. Box: 62182, Dubai, UAE, Tel: +971 43687600, Fax: +971 43687650 - www.caparolarabia.com