Data Sheet: A2T 2.5 EM2 D/6
Data Sheet: A2T 2.5 EM2 D/6
Data Sheet: A2T 2.5 EM2 D/6
Data sheet
A2T 2.5 EM2 D/6 Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany
www.weidmueller.com
Technical data
Dimensions and weights
Depth 50.5 mm Depth (inches) 1.988 inch
Height 90 mm Height (inches) 3.543 inch
Width 5.1 mm Width (inches) 0.201 inch
Net weight 13.034 g
Temperatures
Storage temperature -25 °C...55 °C Continuous operating temp., min. -60 °C
Continuous operating temp., max. 130 °C
Material data
Material Wemid Colour dark beige
Colour of operational elements orange UL 94 flammability rating V-0
System specifications
End cover plate required Yes Number of levels 2
Number of clamping points per level 2 Rail TS 35
N-function No PE function No
PEN function No
Component
Component diode Type diode 1N4007
Forward current 1A
Reverse voltage 1,300 V
Forward voltage 0.7 V
Technical data
Tube length for wire-end ferrule with Cross-section for conductor connection min. 0.14 mm²
plastic collar DIN 46228/4 max. 0.34 mm²
Tube length max. 8 mm
min. 6 mm
Cross-section for conductor connection min. 0.5 mm²
max. 1 mm²
Tube length max. 12 mm
min. 6 mm
Cross-section for conductor connection min. 1.5 mm²
max. 2.5 mm²
Tube length max. 12 mm
min. 8 mm
Tube length for wire-end ferrule without Cross-section for conductor connection nominal 0.25 mm²
plastic collar DIN 46228/1 Tube length nominal 5 mm
Cross-section for conductor connection min. 0.5 mm²
max. 1 mm²
Tube length max. 10 mm
min. 6 mm
Cross-section for conductor connection min. 1.5 mm²
max. 4 mm²
Tube length max. 12 mm
min. 7 mm
Type of connection PUSH IN
Wire connection cross section, finely 4 mm²
stranded, max.
Wire connection cross section, finely 0.5 mm²
stranded, min.
Wire connection cross-section, finely 4 mm²
stranded with wire-end ferrules DIN
46228/1, max.
Wire connection cross-section, finely 0.5 mm²
stranded with wire-end ferrules DIN
46228/1, min.
Wire connection cross-section, finely 2.5 mm²
stranded with wire-end ferrules DIN
46228/4, max.
Wire connection cross-section, finely 0.5 mm²
stranded with wire-end ferrules DIN
46228/4, min.
Wire connection cross-section, solid 2.5 mm²
core, max.
Wire connection cross-section, solid 0.5 mm²
core, min.
General
Rail Standards In accordance with IEC
TS 35 60947-7-1
Rating data
Rated cross-section 2.5 mm² Rated voltage 500 V
Rated current 0.5 A Current at maximum wires 0.5 A
Standards In accordance with IEC Pollution severity
60947-7-1 3
Surge voltage category III
Technical data
UL rating data
Certificate No. (cURus) Conductor size Factory wiring max.
E60693 (cURus) 12 AWG
Conductor size Factory wiring min. Conductor size Field wiring max. (cURus)
(cURus) 28 AWG 12 AWG
Conductor size Field wiring min. (cURus) 28 AWG Current size B (cURus) 1A
Current size C (cURus) 1A Current size D (cURus) 1A
Voltage size B (cURus) 24 V Voltage size C (cURus) 24 V
Voltage size D (cURus) 24 V
Classifications
ETIM 6.0 EC000903 ETIM 7.0 EC000903
ETIM 8.0 EC000903 ECLASS 9.0 27-14-11-27
ECLASS 9.1 27-14-11-47 ECLASS 10.0 27-14-11-27
ECLASS 11.0 27-14-11-27 ECLASS 12.0 27-14-11-27
Approvals
Approvals
Downloads
Approval/Certificate/Document of CE Declaration of Conformity
Conformity UKCA Declaration of Conformity
Engineering Data CAD data -- STEP
User Documentation BPZL AXC 1.5-16
Catalogues
Catalogues in PDF-format
Drawings