N300 HIMS+2000+Program+User+Guide (English)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 35

HiMS2000 software

for N300 Inverter


PRESENTATION
2008. 08

Electro Electric Systems 1


Contents

1. Major features of HiMS2000


2. RS485 communication network
3. Equipment for using HiMS2000 S/W
4. Cable connection & inverter setting
5. HiMS2000 S/W Installation
6. HiMS2000 S/W Operating

Thanks for your interest in our products.


This presentation introduced briefly about directions of HiMS2000 software.
For more information, please refer to our website, http://www.hyundai-elec.com , or contact us.
We look forward to a mutually rewarding relationship with you.

Electro Electric Systems 2


Major Features of HiMS2000

HiMS is an initial letter for


9 HiMS

H yundai
H ii nverter M anagement
M SS ystem.

9 It is possible to
-. control inverter-motor driving system on your laptop.
-. observe inverter-motor driving system on your laptop.
-. change or check inverter parameters on your laptop.
-. watch the waveform inverter-motor driving system.
-. simulate some applications.

Electro Electric Systems 3


RS485 Communication Network

PC or
Notebook
N300 #1 N300 #2 N300 #N

RS232

Signal
Converter
TRX+ TRX-

TM2 TM2 TM2


RS485 SP SN RP SN SP SN RP SN SP SN RP SN

Send/Receive (-)
Send/Receive (+)

Electro Electric Systems Termination Jumper 4


Equipment for using Hims2000 S/W

™ N300 Inverter

™ Notebook PC or Desktop PC
z CPU : Pentium III, 800MHz or more
z Memory : 128MB RAM or more
z Comm. Channel : RS232 Interface
z Operating system : Windows98, Windows2000, WindowsXP

™ Signal converter : RS232 To RS485

™ Connection cable : Shield cable

Electro Electric Systems 5


Cable connection & inverter setting (1/3)
™ Step 1 : Cable connection between PC and N300.
N300
PC RS232 Converter RS485

Item Pin No. Item Pin. No. Terminal


DCD 1 TXD N/A SP
RXD 2 RXD N/A SN
TXD 3 GND N/A
DTR 4
SG(GND) 5 TRXD+ N/A
DSR 6 TRXD- N/A
RTS 7
CTS 8
RI 9

* NOTE : The name, pin number and cable connection method can differ according to
equipment manufacturing company.
Please, connect cable after confirm manual contents in your converters.
If the PLCs have a RS485 communication port, don’t use the converter (RS232
to RS485 converter) between the PLC and inverters.

Electro Electric Systems 6


Cable connection & inverter setting (2/3)
™ Step 2 : Set a termination resistor at end of the wiring.

Electro Electric Systems 7


Cable connection & inverter setting (3/3)
™ Step 3 : Setting for inverter function code
Fucntion Default Setting for
Item Description
code setting HiMS2000

Data command 02 : Digital operator


C070 02 03
source 03 : RS485 connector

Communication 04 : 4800 bps


C071 04 02
baud rate 05 : 9600 bps

C072 Node address 1. 1.~32. Node address for inverter

7 : 7 bit,
C073 Data bits 7 8
8 : 8 bit

C074 Parity 00 00 No parity

C075 Stop bits 1 1 1 : 1 bit

0 to 1000ms time that the inverter waits fo


C078 Wait time 0. 0.
respond to network master

Electro Electric Systems 8


HiMS2000 S/W Installation(1/4)
™ Step 1 : Download S/W on WEB site, and execute
the setup.exe file. (http://www.hyundai-elec.com)

™ Step 2 : S/W installation will be progressed.


Click the “Next” button two times.

Electro Electric Systems 9


HiMS2000 S/W Installation(2/4)
™ Step 3 : Fill in the “Name” and ™ Step 4 : Click the “Next” button.
“Company” text field, and click the Or select another directory and click
“Next” button. the “Next” button.

Electro Electric Systems 10


HiMS2000 S/W Installation(3/4)
™ Step 5 : Select the Program ™ Step 6 : Click the “Next” button.
Folder listed below, and click “Next”
button.

Electro Electric Systems 11


HiMS2000 S/W Installation(4/4)
™ Step 7 : Click the “Finish” button if the setup is finished .

Electro Electric Systems 12


HiMS2000 S/W Operating(1/22)
™ Starting HiMS2000

¾ Start HiMS2000 S/W

¾ Set the COM port (COM1 or COM2 or another


number in case of using the USB To RS232
converter) ; Please check your computer.

¾ Click the “OK” button.

¾ After click the “OK” button, you can see the


following message.

Electro Electric Systems 13


HiMS2000 S/W Operating(2/22)
Calculation View Communication Status
™ Basic screen

Start Drive Parameter Auto tuning Trend Trip Monitor Parameter Parameter Parameter Node
View View View View View View View Upload Download Compare Address
view view view

Electro Electric Systems


Display system Information Display current inverter status 14
HiMS2000 S/W Operating(3/22)
™ Operating screen

¾ Set both Frequency command and Drive command to RS485 in order to


operate Inverter using HiMS2000 software.

¾ Click the icon on HiMS2000 display screen.

Electro Electric Systems 15


HiMS2000 S/W Operating(4/22)
™ Operating screen
¾ Set frequency command to RS485.

Set the frequency commanding


using “+” button.

Electro Electric Systems 16


HiMS2000 S/W Operating(5/22)
™ Operating screen
¾ Set Drive Command to RS485

Set the Drive command


using “+” button.

Electro Electric Systems 17


HiMS2000 S/W Operating(6/22)
™ Operating screen
¾ Set Control methods to VC.
Set the Control methods
using “+” button.

Electro Electric Systems 18


HiMS2000 S/W Operating(7/22)
™ Operating screen
¾ Set frequency and rotating direction

Display current output frequency

Display current rotating direction

Set rotating direction

Set frequency command

Electro Electric Systems 19


HiMS2000 S/W Operating(8/22)
™ Parameter screen
¾ Parameter Up-load
All of the inverter parameter is uploaded to the PC.

Parameter Up-load icon

Electro Electric Systems 20


HiMS2000 S/W Operating(9/22)
™ Parameter screen
¾ Change the setting value of Parameter

Parameter code

Setting value

Parameter setting
range

Electro Electric Systems 21


HiMS2000 S/W Operating(10/22)
™ Parameter screen
¾ Save Parameter : User can save all of the inverter parameter in PC.

Save parameter menu

File name

Electro Electric Systems 22


HiMS2000 S/W Operating(11/22)
™ Parameter screen
¾ Download Parameter
All of the inverter parameter is downloaded to the inverter.
In case of exchanging inverters, you can do it at once with this function.

Download parameter icon

Download parameter menu

Electro Electric Systems 23


HiMS2000 S/W Operating(12/22)
™ Parameter screen
¾ Compare Parameter
Compare saving parameter in PC with current setting value.
After comparing, display only different parameter between saving and setting parameter.
In case of malfunction suddenly, user can check parameters at once with this function

Compare parameter icon

Download parameter menu

Electro Electric Systems 24


HiMS2000 S/W Operating(13/22)
™ Graph screen
¾ User can check output frequency, current, voltage, power, input/output
terminal function and contact status.

Graph menu

Red : terminal closed


Green : terminal open

Electro Electric Systems 25


HiMS2000 S/W Operating(14/22)
™ Graph screen
¾ User can change Y-axis range using “+” button.

Click

Electro Electric Systems 26


HiMS2000 S/W Operating(15/22)
™ Trend screen
¾ User can check some waveforms only one window for comparing each
other.

Trend menu

User can set each channel


ratio.
For example ;
- frequency : 10
- channel range : -100 ~ 100

User can see some inverter


output data.
Electro Electric Systems 27
HiMS2000 S/W Operating(16/22)
™ Trip screen
¾ User can check the 6-times inverter trip information.

Trip history menu

Contents of trip event history

Electro Electric Systems 28


HiMS2000 S/W Operating(17/22)
™ Simulator screen
¾ Driving simulation function (1) - Crane

User can select Crane or


Laundry.

Electro Electric Systems 29


HiMS2000 S/W Operating(18/22)
™ Simulator screen
¾ Driving simulation function (2) - Laundry

User can select Crane or


Laundry.

Electro Electric Systems 30


HiMS2000 S/W Operating(19/22)
™ Save EEPROM
¾ If user changed the value of parameter of inverter, refer to below.

① In case inverter power does not turn off, inverter is driver with changed
parameter.

② But, in case inverter power turn off and turn on, all of the data that user
changed using HiMS2000 disappear from memory of inverter.

③ Therefore, must store data to EEPROM in case user wants to store.

Electro Electric Systems 31


HiMS2000 S/W Operating(20/22)
™ Save EEPROM
¾ EEPROM Check : Verifies whether or nor it is possible to set a particular
parameter in the EEPROM.

EEPROM check menu

Click “Yes” button in above.

Electro Electric Systems 32


HiMS2000 S/W Operating(21/22)
™ Save EEPROM
¾ EEPROM Save : Sets a value in the EEPROM.

EEPROM save menu

Click “Yes” button in above.

Electro Electric Systems 33


HiMS2000 S/W Operating(22/22)
™ Calculate constant
¾ Recalculates the inverter’s internal motor constants.
¾ Use this function after the base frequency or any Hxxx parameters are
changed via the serial link commands.

EEPROM check menu

Click “Yes” button in above.

Electro Electric Systems 34


The End
Thank you for your attention.

http://www.hyundai-elec.com

Electro Electric Systems 35

You might also like