Ad 1500 Iq 4842

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

AD 1500 iQ

Last Updated on 01.02.2022

High-performance laser fume extraction system for heavy-duty


applications in the laser marking, coding and engraving industries.
BOFA’s AD 1500 iQ high-end laser extraction system combines extremely large filter
capacity with high airflow and pressure rates, making it the ideal choice for heavy-duty
applications that generate large amounts of particulate and gaseous organic
compounds.

Performance is enhanced with the inclusion of several features including BOFA’s


patented DeepPleat DUO pre-filter and the acclaimed Intelligent Operating System (iQ).

These take performance and safety parameters to a new level and helps keep
maintenance, downtime and ownership costs to a minimum.

More information about the Intelligent Operating System (iQ).

Technology

Intelligent DeepPleat DUO HEPA filter Automatic flow Reverse flow air Advanced carbon
Operating System pre-filter control (AFC) (RFA) technology filter (ACF)
(iQ) technology technology

Patented ProTECT service SureCHECK


technology plan quality standard

Key features of the AD 1500 iQ

iQ Operating system High airflow and pressure rates


Standard Standard
Reverse flow air filter technology DeepPleat DUO pre-filter
Standard Standard

Contact BOFA at https://bofainternational.com/en/contact/


https://bofainternational.com/en/portal/datasheets/ad-1500-iq/
Combined HEPA / gas filter incorporating ACF technology Automatic flow control system
Standard Standard
Real time airflow reading Independent filter condition monitoring, display and warnings
Standard Standard
High contrast display ‘Run safe’ operation
Standard Standard
Remote diagnostics via USB Filters with long life and low replacement cost
Standard Standard
VOC gas sensor (Volatile Organic Compound) Remote stop / start interface
Optional Optional
Filter change / system fail signal Interfacing with host laser
Optional Optional
Optional filter medias
Optional

Technical specification

1. iQ display 2. On / off switch 3. Power cable 4. Signal / interface cable


5. Castors 6. Door hinge 7. Hose inlet connection - 8. Exhaust outlet
125mm
9. Motor cooling inlet 10. Door latch 11. Motor cooling outlet 12. Standby button
Airflow through filters

Chemical filter

HEPA filter

Pre-filter

Clean air

Contaminated air

Particulate

Technical data

EU

Dimensions (HxWxD) 1205 x 615 x 790mm (47.44 x 24.21 x 31.10”)

Cabinet construction Brushed stainless steel / Powder coated mild steel

Airflow / pressure 1250m³/hr (735cfm) / 100mbar

Electrical data 230v single-phase 1~ 50/60Hz full load current: 24 amps / 3.3kw

415v three-phase 3~ 50/60Hz full load current: 8.5A Pr phase / 14.5A


neutral

Noise level < 68dBA (at typical operating speed)

Weight 146kgs (322lbs)

Approvals UKCA and CE / cUL / UL*

DeepPleat DUO pre-filter specifications

Surface media area 30m² approx (322.8 ft²)

Filter media Borosilicate

Filter media construction Maxi pleat construction with glue bead spacers

Filter housing Zintec mild steel

Filter efficiency 95% @ 0.9 microns

Inlet size 125mm (0.41 ft)

Dropout chamber size 58 litres

Filter media pleat size 200mm (0.65 ft)

Combined HEPA / gas filter specifications

Surface media area 7.5m² approx (80.7 ft²)

HEPA filter media Borosilicate

HEPA media construction Maxi pleat construction with glue bead spacers
Combined HEPA / gas filter specifications

Filter housing Zintec mild steel

Treated activated carbon 34kgs (74.8 lbs)

Filter efficiency 99.997% @ 0.3 microns

Unit part numbers

Model Voltage Part no. 24V stop / start Filter change / VOC monitoring
system failure
signal

AD 1500 iQ 230V L0862 A2001 A2002 A2003


powder coated

AD 1500 iQ 3Ph L0863 A2001 A2002 A2003


powder coated

AD 1500 iQ 230V L0872 A2001 A2002 A2003


stainless steel

AD 1500 iQ 3Ph L0873 A2001 A2002 A2003


stainless steel

Replacement filter part numbers

Model DeepPleat DUO pre-filter Combined filter

AD 1500 iQ A1030222 A1030297

* Tested to UL and cUL standards, but testing may be provided by alternate nationally recognised test laboratories. Certain product
configurations may affect the UL certification. Please speak to your sales representative.

Other languages

AD 1500 iQ AD 1500 iQ
Italian French
AD 1500 iQ
Chinese

Datasheet correct at time of publishing.

Where applicable, the carbon used in BOFA units is capable of removing a wide range of VOCs, however it is the responsibility of the user
to ensure the carbon is suitable for their application. For specific applications, please contact us for details.

Important Notice: Many factors beyond the control of BOFA can affect the use and performance of BOFA products in a particular application, including
the conditions under which the product is used. Since these factors are uniquely within the user’s knowledge and control, it is essential the user evaluate
the products to determine whether the product is fit for the particular purpose and suitable for the user’s application. All products, product
specifications, availability and data are subject to change without notice, and may vary by region or country.

Think before you print! Please consider the environment before printing this document.