FO CONVERTER
Signal Distribution over long Distances
1 Imprint 1
1 Imprint
Meinberg Funkuhren GmbH & Co. KG
Lange Wand 9, 31812 Bad Pyrmont / Germany
Phone: + 49 (0) 52 81 / 93 09 - 0
Fax: + 49 (0) 52 81 / 93 09 - 230
Internet: https://www.meinbergglobal.com
Mail: [email protected]
Date: 2019-01-13
If a procedure is marked with the following signal words, you may only continue, if you have understood and
fulfilled all requirements. In this documentation dangers and indications are classified and illustrated as follows:
DANGER!
The signal word indicates an imminently hazardous situation with a high risk level . This notice
draws attention to an operating procedure or similar proceedings, of which a non-observance may
result in serious personal injury or death .
WARNING!
The signal word indicates a hazard with a medium risk gradient . This notice draws attention to an
operating procedure, a procedure or the like which, if not followed, can lead to serious injuries ,
possibly resulting in death .
CAUTION!
The signal word indicates a hazard with a low risk gradient . This notice draws attention to an
operating procedure, a procedure or the like which, if not followed, can lead to minor injuries .
ATTENTION!
This notice draws attention to an operating procedure, a procedure or the like which, if not followed,
can cause damage to the product or loss of important data .
This manual contains important safety instructions for the installation and operation of the
device. Please read this manual completely before using the unit.
This device may only be used for the purpose described in this manual. In particular, the given
limits of the device must be observed. The safety of the installation in which the unit is
integrated is the responsibility of the installer!
Non-observance of these instructions can lead to a reduction in the safety of this device!
This manual is intended exclusively for electricians or persons trained by an electrician who are familiar with
the applicable national standards and safety rules. Installation, commissioning and operation of this device may
only be carried out by qualified personnel.
WARNING!
When the built-in unit is used in a terminal (e.g., housing cabinet), additional requirements
according to Standard IEC 60950-1 must be observed and complied with. In particular, the general
requirements and the safety of electrical equipment (such as IEC, VDE, DIN, ANSI) as well as the
applicable national standards are to be observed.
The device has been developed for use in the industrial sector as well as in residential areas and
can only be used in such environments. For environments with higher levels of soiling, additional
measures, e.g. Installation in an air-conditioned control cabinet required.
When unpacking, setting up, and before operating the equipment, be sure to read the information on
the hardware installation and the specifications of the equipment. These include, for example,
dimensions, electrical characteristics, and necessary ambient and climatic conditions, etc.
For mounting, the housing must not be damaged. No holes may be drilled in the housing.
For safety reasons, the device with the highest mass should be installed in the lowest position of
the rack. Other devices must be placed from the bottom to the top.
The device must be protected against mechanical stress such as vibration or shock.
When wiring the devices, the cables must be connected or disconnected in the order of the
arrangement described in the user documentation accompanying the device. Always attach all cables
to the plug during connection and removal. Never pull the cable itself. Pulling the cable can cause
the cables to disconnect from the plug.
Install the cables in way that they do not constitute a hazard (danger of tripping) and are not
damaged, i.e. kinked.
Before connecting to the power supply, a grounding cable must be connected to the earth connection
of the device.
Before operation, check that all cables and lines work properly and are undamaged. Pay particular
attention to the facts that the cables do not have kinks or that they are not too short around corners,
and no objects are placed on the cables. Also make sure that all connections are secure.
Faulty shielding or cabling will endanger your health (electrical shock) and may destroy other
equipment.
Ensure that all necessary safety precautions have been taken. Make all connections to a unit before
turning on the power. Observe the safety instructions on the device (see safety symbols).
The metal housing of the device is grounded. It must be ensured that enough air and creepage
distances to neighboring voltage-carrying parts are provided during assembly in the control cabinet
and no short circuits are caused.
In the case of malfunctions or servicing (e.g. in the event of a damaged housing or power cable or
when fluids or foreign objects enter), the current flow can be interrupted. Questions about the
house installation, need to be clarified with your house administration.
ATTENTION!
In order to ensure safe operation and to meet the requirements of IEC 62368-1, the device
must be correctly connected to the protective earth conductor via the protective earth
connection terminal.
Note:
Please use a grounding cable ≥ 1.5 mm2
Always pay attention to a correct crimp connection!
WARNING!
Avoiding Short-Circuits
Make sure not to get any objects or liquids inside the unit. Electric shock or short circuit
could result.
Ventilation Slots
Make sure that the ventilation slots are not covered or dusty, as there is a danger of overheating
during operation. Disturbances during operation can result.
Normal Operation
The normal operation and the observance of the EMC limits (electromagnetic compatibility) are only
ensured if the housing cover is properly installed and when the doors are closed (cooling, fire protection,
shielding against electrical, magnetic and electromagnetic fields).
ATTENTION!
Laser Class 1
Risk of injury from laser!
The optical interface corresponds to laser class 1 according to IEC 60825-1 and contains
a light-emitting diode (LED). A direct view into this beam should be avoided.
Unused connectors of optical interfaces should always be provided with the protective cap.
WARNING!
When you are expanding the device, use only device parts that are approved for the system.
Non-observance may result in injury to the EMC or safety standards and cause malfunction
of the device.
If device parts, which are released for the system, are extended or removed there may be a
risk of injury in the area of the hands, due to the pull-out forces (approx. 60 N).
The device must not be opened, repairs to the device may only be carried out by the
manufacturer or by authorized personnel. Improper repairs can result in considerable
danger to the user (electric shock, fire hazard).
Unauthorized opening of the device or of individual parts of the device can also lead to
considerable risks for the user and result in a loss of warranty as well as an exclusion
of liability.
- Device parts can become very hot during operation. Do not touch these surfaces!
If necessary, switch off the unit before installing or removing any equipment,
and allow it to cool down.
ATTENTION!
Do not wet clean the appliance! Penetrating water can cause considerable dangers to
the user (e.g., electric shock).
Liquid can destroy the electronics of the device! Liquid penetrates into the housing
of the device and can cause a short circuit of the electronics.
Only clean with a soft, dry cloth. Never use solvents or cleaners.
ATTENTION!
The designation ESD (Electrostatic Sensitive Devices) refers to measures which are used
to protect electrostatically endangered components from electrostatic discharge and thus
to prevent destruction. Systems and assemblies with electrostatically endangered components
usually have the following characteristics:
Ensure that you wear a grounding strap on the wrist when working with such assemblies, which
you attach to an unpainted, non-conductive metal part of the system.
Use only tools and devices that are free from static electricity.
Transporting Assemblies
Assemblies may only be touched at the edge. Do not touch any pins or conductors on assemblies.
Storing Assemblies
Always keep assemblies in ESD protective covers. These protective covers must be undamaged.
ESD protective covers, which are extremely wrinkled or even have holes, no longer protect against
electrostatic discharge.
ESD protective covers must not be low-resistance and metallically conductive if a lithium battery
is installed on the assembly.
ATTENTION!
Separate Collection
Product Category: According to the device types listed in the WEEE Directive, Appendix 1,
this product is classified as an IT and communication device.
This product meets the labeling requirements of the WEEE Directive. The product symbol on
the left indicates that this electronic product must not be disposed of in domestic waste.
The withdrawal may be refused in the case of waste equipment which presents a risk to
human health or safety due to contamination during use.
The standard modules are suited for signals like PPS, PPM, IRIG-B DCLS or 10MHz. The required sup-
ply voltage (20 - 60 V DC) is provided by a power adapter (Vin : 100 - 240 V AC; Vout : 24 V DC) which is
optionally included in the scope of supply. All converter variants are equipped with a fixing clamp for 35mm
DIN mounting rails. If necessary, each of the output signals can be inverted on request.
Transmission distances of up to 2000 meters can be realized with multimode converters. A transmission distance
of 10 kilometres can be achieved with singlemode converters.
Temperature: 0 ... 50 ◦ C
Storage Temperature: -25 ... 70 ◦ C
Power Supply
Input Parameter -
——————————————————————————–
Nominal voltage range: UN = 48 V
Maximum voltage range: Umax = 20 - 60 V
Nominal current: IN = 0.22 A
+
Output Parameter
——————————————————————————– UN = 48 V
Maximum power: Pmax = 10 W Umax = 20 - 60 V
Maximum heat: Etherm = 36.01 kJ/h (34.13 BTU/h)
The fiber optic module CON/TTL/FO converts an input The following options are possible:
signal (TTL, RS422 or FO) into one or more FO (fiber
optical) output signals. 1.) CON/TTL/FO: TTL input via BNC connector to
one FO output
2.) CON/TTL/FO-x: TTL input (BNC) to x (2, 3 or 4)
FO outputs
TTL to FO Converter
CON/TTL/FO 3.) CON/422/FO: RS422 input via 9pin-DSub connec-
tor to one FO output
4.) CON/422/FO-x: RS422 input (DSub) to x (2, 3 or
4) FO outputs
5.) CON/FO/FO-x: FO input (ST) to x (2, 3 or 4) FO
outputs
V2
CON/TTL/FO-4
Launchable
output Power: typ. 15 µW per output (into GI 50/125 µm gradient fiber)
3.3 CON/FO/TTL
The fiber optic module CON/FO/TTL converts a FO The following options are possible:
(fiber optical) input signal into one or more electrical
output signals (TTL or RS-422). 1.) CON/FO/TTL: two TTL outputs via BNC con-
nector
2.) CON/FO/422: one RS422 output via 9pin-DSub
connector
FO to TTL Converter
CON/FO/TTL 3.) CON/FO/TTL/422: one TTL output (BNC) and one
RS422 output (DSub)
CON/FO/TTL
optical
input level: min. 3µW
electrical
Outputs: TTL output signal via female BNC connector
RS422 output signal via female 9pin-DSub connector
(Pin7: +OUT, Pin8: -OUT)
The fiber optic module CON/232/FO converts a RS- Standard variants (for RxD and TxD)
232 signal (TxD and RxD) into optical signals. CON/232/FO: RS-232 (DB9 male) to 1 x FO In
and 1 x FO Out
RS232 to FO Converter
CON/232/FO CON/232/FO-1: TxD In (DB9 male) to 1 x FO Out
CON/232/FO (RxD)
Optical
Signals: 1 multimode FO output (TxD) and 1 x FO input (RxD) or
up to four multimode FO outputs via ST connectors
(for GI 50/125µm or GI 62,5/125µm gradient fiber)
Launchable
output power: typ. 15 µW per output (into GI 62,5/125µm gradient fiber)
Optical
input level: min. 3 µW
These fiber optic modules carry an amplitude mod- Variant to convert a Time Code AM signal to FO
ulated Time Code AM signal over an optical fiber. CON/TCM/FO: Time Code In (BNC) to 2 x FO Out
Signal delay: 60µs
Variant to back-convert the FO signal to Time Code
AM
CON/FO/TCM: FO In to 2 x Time Code Out (BNC)
CON/TCM/FO
TCM to FO Converter
CON/TCM/FO-2
optical
Outputs: 2 multimode FO outputs via ST connectors
(for GI 50/125µm or GI 62,5/125µm gradient fiber)
Launchable
output power: typ. 15 µW per output (into GI 62,5/125µm gradient fiber)
CON/TTL/FOS-4
Optical
Outputs: up to four singlemode FOS outputs via ST connectors
for E9/125µm monomode fiber, wave length: 1310 nm
Launchable
output power: typ. 15 µW (-15 dBm) per output
3.7 CON/FOS/TTL
CON/FOS/TTL
Electrical
Outputs: 2 x TTL signal via BNC female connectors
2.5 V into 50 Ohm
or
1 x RS422 signal via DSub9 female connector
pin 5: GND, pin 7: +IN, pin 8: -IN
Signal-Jitter: <1 ns