SAP1000 Active Probe User Manual
Contents
CONTENTS ............................................................................................................................................................................ 2
1 INTRODUCTION ................................................................................................................................................... 3
2 GENERAL SAFETY SUMMARY ....................................................................................................................... 4
2.1 SAFETY TERMS AND SYMBOLS ........................................................................................................................... 4
2.2 WORKING ENVIRONMENT ................................................................................................................................... 5
2.3 CALIBRATION ...................................................................................................................................................... 6
2.4 CLEANING ........................................................................................................................................................... 6
2.5 ABNORMAL CONDITIONS .................................................................................................................................... 6
3 FIRST STEPS........................................................................................................................................................... 8
3.1 DELIVERY C HECKLIST ........................................................................................................................................ 8
3.2 FUNCTIONAL C HECK........................................................................................................................................... 8
3.3 QUALITY ASSURANCE ........................................................................................................................................ 9
3.4 MAINTENANCE AGREEMENT ............................................................................................................................ 10
4 INTRODUCTION ................................................................................................................................................. 11
5 STANDARD ACCESSORIES ............................................................................................................................. 12
6 PROBE OPERATION .......................................................................................................................................... 16
6.1 CONNECTING THE PROBE TO AN OSCILLOSCOPE .............................................................................................. 16
6.2 CONNECTING THE PROBE TO THE TEST CIRCUIT .............................................................................................. 17
7 CONTACT SIGLENT .......................................................................................................................................... 18
2 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
1 Introduction
This user manual includes important safety information related to the SAP1000
active probe and simple tutorials for basic operation of the probe.
3 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
This chapter contains information and warnings that must be followed to keep
the probe operating under the appropriate safety conditions. In addition to the
safety precautions specified in this section, you must also follow recognized
safety procedures.
explosive environments.
Be careful with sharp tips. The tips may cause bodily injury if not handled
properly.
Connect the signal wire correctly. The potential of the signal wire
ground is equal to the earth; therefore, do not connect the signal wire to a
high voltage. Do not touch the exposed contacts or components.
Do not operate with suspected failures. Do not use the probe if any part
This symbol may appear on the probe body or in this manual to alert you to
4 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
The accessory is intended for indoor use and should be operated in a clean,
dry environment. Before using this product, ensure that its operating
Temperature: 5 to 40°C.
Note: Direct sunlight, radiators, and other heat sources should be taken into
5 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
2.3 Calibration
2.4 Cleaning
The exterior of the probe and cable should be cleaned, using a soft cloth
moistened with water. The use of abrasive agents, strong detergents, or other
solvents may damage the probe. Always ensure that the input leads are free of
debris. To avoid electrical shock, unplug the probe from the scope before
cleaning.
Only operate the probe for the purposes specified by the manufacturer.
Do not operate the probe if there is any visible sign of damage or if it has been
subjected to severe transport stresses.
If you suspect the probe has been impaired, disconnect the probe from the
6 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
Proper use of the probe depends on careful reading of all instruction and
labels.
7 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
3 First steps
First, verify that all items listed on the packing list have been delivered. If you
replacement.
The functional check verifies the basic functional of the probe functions.
8 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
3. Touch Probe in the C1 menu, and then check the information of the probe,
and attenuation.
7. Set the vertical scale of channel 1 to1 V/div, 500 mV/div, 200 mV/div, 100
The probe has a 3-year warranty (1-year warranty for probe attachments) from
the date of shipment, during normal use and operation. SIGLENT can repair or
replace any product that is returned to the authorized service center during the
warranty period. We must first examine the product to make sure that the
9 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
SIGLENT shall not be responsible for any defect, damage, or failure caused by
10 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
4 Introduction
its low input capacitance and high input resistance, the circuit loading is
minimized.
With the SAPBus interface, the SAP1000 becomes a part of the oscilloscope
system. The probe can be controlled from the oscilloscope. The oscilloscope
provides power to the probe, so there is no need for a separate power supply
or batteries.
Key Benefits:
DC Input Resistance 1 MΩ
SAPBus interface
11 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
5 Standard Accessories
L-adapter 2.74.70.12.005 1
Z-Ground 2.74.70.12.006 1
12 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
Straight Tip:The straight tip is rugged and designed for general probing.
Pogo Tip:The pogo tip provides z axis compliance. The tip can fit into a socket
13 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
L-adapter:This adapter has a socket on one end and a square pin with a right
angle on the other to connect to the input or ground socket of the probe body,
probe head. The Z-Ground is the highest quality grounding solution and is
recommended in high frequency applications.
Y-Lead Adapter : This lead is used for both ground and input lead
simultaneously. It has two sockets on one end and two round pins on the other
60/120 Straight Pin Lead:These leads have a socket on one end and a round
pin on the other to connect to the input or ground socket of the probe body,
14 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
50/100 Right Angle Pin Lead :These leads have a socket on one end and a
round pin with a right angle on the other to connect to the input or ground
socket of the probe body, and may be used for general purpose probing.
Colored Clips: These colored clips can be used to distinguish a specific probe
from other similar probes being used in the measurement.
15 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
6 Probe Operation
handling and storing the probe. Always handle the probe by the probe body or
compensation box. Avoid putting excessive strain or exposing the probe cable
to sharp bends.
The SAP1000 probe has been designed for being used with SIGLENT’s
attach the probe output connector to the oscilloscope’s input connector, the
graphical user interface. Turning the Volts/div knob controls the oscilloscope’s
scale factor to give full available dynamic range up to 2 V/div (16 V peak to
peak). Turning the channel offset knob controls the probe input offset circuit
16 / 19 WWW.SIGLENT.COM
SAP1000 Active Probe User Manual
applications, care must be exercised in connecting the probe to the test circuit.
introduce a “ring” or slow the rise time of fast signals. Input leads which form a
large loop area will pick up any radiated electromagnetic field which passes
through the loop and may induce noise into the probe input.
17 / 19 WWW.SIGLENT.COM