SOP-20-CP Smart Operation Panel User Guide
SOP-20-CP Smart Operation Panel User Guide
SOP-20-CP Smart Operation Panel User Guide
SOP-20-CP Smart Operation Panel Components Table 1 Display content description of the SOP-20-CP Table 3 Description of shortcuts
tant for systems of frequency conversion and speed regulating. tween the PC tool (installed with the InoDriveStudio software) and the AC Parameter
+ To restore default value
modifying interface
Featuring wide power supply range and LCD display, it provides the functions of drive. SOP-20
parameter setting, status monitoring, parameter copying, fault analysis and posi- 2) The SOP can work in USB disk mode to read/write the SOP-20-880 SD
tioning, program downloading, and USB relay/USB disk. card through the PC. Direction
● RJ45 interface Status Indicators
Left Right
To connect the SOP-20-CP to the AC drive
Nameplate and Designation Rule ESC ENTER
The status indicator is used to indicate whether a fault or alarm exists.
● Nameplate
Table 4 Description of the status indicators
To show information such as product model and serial number Shift Help
SOP - 20 - CP
Indicator Status Example Indication
● Battery cover RUN STOP
MENU
The battery and SD card slot are beneath the cover. Run Stop/Reset Steady on in green The device runs normally.
The SOP-20-CP can be installed on the cabinet door by using an IP20 ESC Left The key selection at the lower left corner of the display
Figure 1 Nameplate and designation of the SOP-20-CP installation package. For systems with higher protection class (IP54), an
shows its function in context, for example, pressing the
key on the main display brings you to the device list.
General Specifications
installation package with equivalent protection class is available as an option Normally to select or confirm Table 5 General specifications
(optional IP54 installation package for the SOP-20-CP).
ENTER The key selection at the lower right corner of the display
Dimensions Fix the SOP-20-CP with the fastening screws.
Right
shows its function in context, for example, pressing the S.N. Item Running Storage Transportation
key on the main display brings you to the menu.
1 Temperature -20 to +55°C -40 to +70°C -40 to +70°C
72 26.4
To quickly enter the device list
2 Altitude <4000m - -
Shift On some interfaces, you are not allowed to switch over
Display the devices and the key is invalid.
3
Relative
95% (non-condensing)
humidity
The SOP-20-CP uses a monochrome LCD display of 240 x 160 pixel with white To open the help page
backlight. Pollution
Help The content on the help page is relevant to corresponding 4 3C3(IEC 60721-3-3, IEC 60721-3-2, IEC 60721-1-3-1)
degree
menu or interface.
1 2 61800-5-1 ed 2
2M3
Stop Device status 5 Vibration EN 60082-2-6 test -
RUN Run To start the device in local control mode (EN 60082-2-6)
01 Air dissipation pressure Fc (1g)
0.00 3M4
123
2M2
Stop/ To stop the device in local control mode 6 Impact -
ESC ENTER 02 Compressor head temperature STOP (EN 60062-2-27) (EN 60082-2-27)
3 Reset To reset the fault when the device is in fault status
25
IEC-60068-2-32
03 This running time 7 Free drop - -
Drop height: 1 m
0 MENU Menu To quickly show the menu
RUN STOP Protection When installed on AC drive: IP54 (Use IP 54 options)
Mode Disable 18:00:02 Menu 8
level
MEUN Without installation: IP20
To use and to select items in the menu
4 5 6 7 4 9 EMC IEC 61800-3
and list, scroll the text page, and adjust the values
(time setting, password entering, or parameter value The SOP-20-CP is recyclable. Refer to relevant international
Figure 4 Display example of the SOP-20-CP Direction modifying). 10 Disposal
and local laws and regulations for disposal and recycling.
Figure 2 Dimensions of the SOP-20-CP (unit: mm) To use and to move the cursor left or right when
1) Press the MENU key to enter the parameter interface as follows: Step 1: Use a slotted screwdriver or
fingers to remove the battery
Stop cover.
External keypad is not supported if IP54 installation package is used.
01 Running parameters
Figure 18 Replacing the SD card (step 3)
02 AC drive parameters Connecting to the PC
Step 4: Put down the metal cover and
03 Maintenance parameters push the metal cover towards the
The USB connector of the SOP-20-CP is mini-B type. The USB cable length can- lock direction to fix the SD card.
04 Protection parameters not exceed 3 m and the communication protocol is USB2.0. Lock
2) Select each parameter group to set relevant parameters for the air compres-
sor. For example, selecting "01 Running parameters" brings you to the inter-
Figure 19 Replacing the SD card (step 4)
face for setting running parameters as follows:
Step 5: Put the battery cover back.
Stop
Frequency reference upper limit Figure 12 Replacing the battery (step 1)
150.00 Hz Step 2: Take out the battery with
ESC ENTER
Frequency reference lower limit tweezers or a slotted screwdriver.
40.00 Hz
Pre-operation frequency RUN STOP
Figure 20 Replacing the SD card (step 5)
MENU
50.00 Hz
Mode Disable 18:00:02 Select
3) Select "03 Maintenance parameters" to set maintenance parameters, and so on. Figure 13 Replacing the battery (step 2) Warranty Agreement
Step 3: Place the new battery into the
Installation on the Cabinet Door Figure 9 Connecting the SOP-20-CP to the PC (step 1) clip (A side) first and then press
1) The warranty period of the product is 18 months from the date of manufacturing.
During the warranty period, if the product fails or is damaged under the condition
the other end (B side) of the of normal use by following the instructions, Inovance will be responsible for free
When the SOP-20-CP is installed on the cabinet door: 2) Plug one end of the USB cable into the SOP-20-CP and the other end into A B battery. maintenance.
1) Fix the base on the cabinet door with four fastening screws ( 3 ) as the PC. It is recommended to use USB cable with ferrite rings.
2) Within the warranty period, maintenance will be charged for the damages caused
shown in Figure 7. by the following reasons:
2) Install the SOP-20-CP in the base. a) Improper use or repair/modification without prior permission
Metal sheet /cabinet door Figure 14 Replacing the battery (step 3) b) Fire, flood, abnormal voltage, other disasters and secondary disasters
c) Hardware damage caused by dropping or transportation after procurement
3 3 Step 4: Put the battery cover back.
SOP-20-CP d) Improper operations
e) Damage out of the equipment (for example, external device factors)
3) If there is any failure or damage to the product, please correctly fill out the Product
1 1
Warranty Card in detail.
4) The maintenance fee is charged according to the latest Maintenance Price List of
2 Figure 10 Connecting the SOP-20-CP to the PC (step 2)
Inovance.
5) The Product Warranty Card is not re-issued. Please keep the card and present it
Figure 15 Replacing the battery (step 4)
to the maintenance personnel when asking for maintenance.
6) If there is any problem during the service, contact Inovance’s agent or Inovance
directly.
1
When the SOP-20-CP is connected to the PC, the interface as Figure 11 SD Card Replacement 7) This agreement shall be interpreted by Inovance.
3 3 will appear.
2
Plug and play is not supported. Replace the SD card when the SOP-20-CP is
powered off. Product Warranty Card
Step 1: Use a slotted screwdriver or
Select USB Connect Mode Company address:
fingers to remove the battery
USB Relay Mode cover.
Figure 7 Installing the base on the cabinet door USB disk Company name: Contact person:
Customer
In Figure 7: information
1 are screws to fix the SOP-20-CP, used in IP54 protection level. P.C.: Tel or Email:
2 are screws to fix the PCB and to connect to the PE.
3 are screws to fix the base on the cabinet door.
Product model:
Back 18:00:02 Select
Product infor- Product SN (Attach here):
Base (IP20/IP54) 2 mation
Figure 11 Interface after connecting the SOP-20-CP to the PC Name of supplier:
Seal strip for IP54
If "USB Relay Mode" is selected, the SOP-20-CP is for data communication be-
(Maintenance time and content):
tween the PC tool and the AC drive.
Figure 16 Replacing the SD card (step 1) Failure infor-
If "USB Disk" is selected, the SOP-20-CP is used as a memory.
ESC ENTER
mation (e.g.
Step 2: Push the metal cover towards the fault code) Maintenance personnel:
RUN STOP unlock direction to release the
SD card.
MUNE
1
IP20: with through
groove
IP54: sealed Unlock Suzhou Inovance Technology Co,.Ltd
Address: No.16, Youxiang Road, Yuexi Town,
Wuzhong District, Suzhou 215104, P.R. China
Figure 17 Replacing the SD card (step 2) Tel: 400-777-1260 P.C.: 215104
Figure 8 Installing the SOP-20-CP in the base Website: http://www.inovance.cn