Rectangular Footing - Concrete Design
Rectangular Footing - Concrete Design
Rectangular Footing - Concrete Design
Footing, rectangular
specification
fc' 21 MPa
fy 275 MPa
wt. of concrete 20 kN/m3
earth unit weight 15.7 kN/m3
q, allowable soil pressure 250 kPa
service load
service Dead load 689 kN
service Live load 255.98 kN
overburden 1.5 m
column
h, along footing long direction 300 mm
b, along footing short direction 200 mm
R-bars to use
Phils. Standard Reinforcing Bars
r-bar
footing reinforcement
16mm
Results:
r-bar no. OK - soil pressure
column dowels
16mm 4 min. 4 OK - 2-way shear
OK - beam shear
OK - ld at long direction
OK - no. of column dowels
use ld min 200 mm into both column and footing
0 m. 2 m. 0 m.
300 mm
2m 200 mm
27 - 16mm longitudinal bars
27 - 16mm 0 - 16mm
transverse bars at center transverse bars at outer
strip strip
long direction
short direction
0.6 m
2m
solution
qa ,allowable value of soil pressure = q* Pu /(DL + LL) 404.6826 kPa >>== 382.417
OK - soil pressure
d/2 c d/2
Bending moment
long direction
x
L
x=( L-h)/2 0.85 m
actual bending moment Mu = qu*B*x2/2 276.2962 kN-m
Mn = Mu/.90 306.9958 kN-m
m = fy/.85fc' 15.40616
Rn = Mn/Bd2 563.3282 kPa
ρ = 1/m(1-√1-2mRn/fy) 0.002082
ρmin = 1.4/fy 0.005091
required ρ = 0.005091
As = ρ (actual B*d) 5314.909 mm2
no. of bars 16mm longitudinal bars 27 ea.
check ld
required ld = .02Ab*fy/√fc' 241.3599 mm
or ld = .06dbfy 264 mm
required ld = 264 mm
x'
L
x' = (B - b)/2 0.9 m.
actual bending moment Mu = qu*L*x'2/2 309.7577 kN-m
Mn = Mu/.90 344.1753 kN-m
m = fy/.85fc' 15.40616
Rn = Mn/Ld2 631.5513 kPa
ρ = 1/m(1-√1-2mRn/fy) 0.002339
ρ min = 0.005091
required ρ = 0.005091
As = ρ (actual L*d) 5314.909 mm2
no. of bars 16mm 27 ea.
for centerstrip 16mm transverse bars at center strip 27 ea. 2 m
for outerstrip 16mm transverse bars at outer strip 0 ea. 0 m
check ld
required ld = 264 mm
actual ld = x' - concrete cover 830 mm>>== 264
OK - ld at short direction