QUA EnviQ XL Datasheet
QUA EnviQ XL Datasheet
QUA EnviQ XL Datasheet
www.quagroup.com
EnviQ XL
Submerged Ultrafiltration Membranes
®
Product Specifications
EnviQ Model
XL-330 XL-440 XL-550
Technical Information
Operational Parameters Unit Range
MLSS mg/L 3,000 – 15,000
Filtrate Flux Range lmh / gfd 10 – 28 lmh / 6 – 16.5 gfd⁴ (Dependent on feed conditions)
Operating Transmembrane Pressure mmHg 100 mm Hg (Typical) - 200 mm Hg (Maximum)
psi 2.0 psi (Typical) - 4 psi (Maximum)
Backpulse Transmembrane Pressure mmHg / psi 52 mmHg / 1.0 psi (Maximum)
Backpulse Requirement N/A 7.5 minutes every 2-4 hours
Operating Time Ratio N/A Service time 9.5 minutes, Rest time 0.5 minutes
Operating pH Range - 5-9
Typical Product TSS mg/L < 3.0
Typical Product Turbidity NTU < 1.0
Cleaning Chemicals
Maintenance Cleaning⁵ NA NaOCl (250 ppm as Cl₂) and Citric Acid (1,000 ppm )
Recovery Cleaning⁶ NA NaOCl (1,000 ppm as Cl2) and Citric Acid (1,000 ppm)
4 Please consult QUA for guidance on modified air flow requirements for fluxes greater than 25 lmh (14.7 gfd).
5Typically required once a week depending on feed conditions.
6Typically required once every 3-4 months depending on feed conditions.