133 BK 112017

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Code No: 133BK R16

JAWAHARLAL NEHRU TECHNOLOGICAL UNIVERSITY HYDERABAD


B.Tech II Year I Semester Examinations, November/December - 2017
NETWORK THEORY
(Electrical and Electronics Engineering)
Time: 3 Hours Max. Marks: 75

Note: This question paper contains two parts A and B.


Part A is compulsory which carries 25 marks. Answer all questions in Part A.
Part B consists of 5 Units. Answer any one full question from each unit.
Each question carries 10 marks and may have a, b, c as sub questions.

PART- A
(25 Marks)
1.a) Give the advantages and disadvantages of tie-set matrix. [2]
b) Write the expression for total inductance of the three series connected coupled
coils connected between A and B as shown in circuit shown in figure 1. [3]

Figure: 1
c) What are the advantages of poly phase system over single phase system? [2]
d) Explain the effect of power factor on wattmeter readings in two wattmeter
method. [3]
e) Explain why the current in inductance does not change in zero time. [2]
f) Write a short note on the procedure employed to evaluate initial conditions.
[3]
g) Define active and passive ports. [2]
h) Express Z-parameters in terms of ABCD parameters. [3]
i) List out the disadvantages of constant – k filters. [2]
j) Sketch the frequency response of high pass filters. [3]

PART-B
(50 Marks)
2. Determine voltage V across a 15 ohms resistor in the magnetically coupled circuit
shown in Figure 2. Take Vs = 30∠40 degrees. [10]

WWW.MANARESULTS.CO.IN
Figure: 2
OR
3. For the graph shown in Figure 3, write the incidence matrix. Express branch
voltage in terms of node voltages and then write a loop matrix and express branch
currents in terms of loop currents. [10]

Figure: 3
4.a) Derive the relation between line and phase voltages and currents for a balanced
STAR connected system.
b) The two watt meter readings in a 3-phase power measurement are 8 KW. The
latter reading is being obtained after the reversal of current coil. Calculate the
total power, Active Power, Reactive power and power factor of the load. [5+5]
OR
5. A three phase balanced delta connected load of (9+j2) ohm is connected across a
400V, 3ϕ balanced supply. Determine the phase currents and line currents.
Assume the phase of sequence to be RYB. Also calculate the power drawn by
load. [10]

6. With the switch open steady state is reached with V =100 sin 314 t volts. The
switch is closed at t=0. The circuit is allowed to come to steady state again.
Determine steady state current and complete solution of transient current
(figure 4). [10]

Figure: 4
OR
7. Obtain the expression for i(t) for a series RL circuit when exited by a source of
V(t)=Vm sin (wt+θ) using Laplace transform. [10]

8. Find the Y-parameters for the circuit shown in figure 5. [10]

WWW.MANARESULTS.CO.IN
Figure: 5
OR
9. The Z-parameters of a two- port network are Z11=15Ω, Z12=Z21=6Ω and Z22=24Ω.
Determine ABCD parameters. [10]

10. Design a band pass filter with cutoff frequencies of 2000Hz and 5000Hz with a
design impedance of 500 ohms. [10]
OR
11. Design a m-derived low filter with a design impedance of 300Ω and the cut off
frequency at 2 KHz and infinite attenuation at 2345Hz. [10]

---oo0oo---