NI25-CK40-LIU-H1141 Inductive Sensor - With Analog Output

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

NI25-CK40-LIU-H1141

Inductive Sensor – With Analog Output


Features

■Rectangular, height 40 mm
■Variable orientation of active face in 5 direc-
tions
■Plastic, PBT‐GF30‐V0
■4‐wire, 15…30 VDC
■Analog output
■0…10 V and 0…20 mA
■M12 x 1 male connector

Wiring diagram

Technical data

Type NI25-CK40-LIU-H1141
ID 1537802
General data  
Measuring range 5…25  mm
Mounting conditions Non-flush
Secured operating distance ≤ (0.81 × Sn) mm
Repeatability ≤ 1 % of measuring range |A - B|
0.5 %, after warm-up 0.5 h
Functional principle
Reproducibility ≤ 200 µm
Inductive TURCK sensors with analog output
≤ 100 µm, after a warm-up time of 0.5 h accomplish simple control tasks. They

NI25-CK40-LIU-H1141 | 20-04-2022 05-31 | Technical modifications reserved


Linearity deviation ≤ 5 % provide a current, voltage or frequency signal
proportional to the target's distance. The
Temperature drift ≤ ± 0.06 % / K output signal is linear to the distance of the
target over the entire sensing range.
Electrical data    

Operating voltage 15…30  VDC


Residual ripple ≤ 10 % Uss
No-load current 8  mA
Isolation test voltage ≤ 0.5 kV
Short-circuit protection yes
Wire breakage/Reverse polarity protec- no / Complete
tion
Output function 4-wire, Analog output
Voltage output 0…10  V
Current output 0…20  mA
Load resistance voltage output ≥ 4.7 kΩ
Load resistance current output ≤ 0.4 kΩ
Measuring sequence frequency 30 Hz

Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com 1|3
Technical data

Mechanical data  
Design Rectangular, CK40
Dimensions 65 x 40 x 40  mm
variable orientation of active face in 5 di-
rections
Housing material Plastic, PBT-GF20-V0, Black
Active area material Plastic, PA12-GF30, yellow
Electrical connection Connector, M12 × 1
Environmental conditions  
Ambient temperature -25…+70  °C
Vibration resistance 55 Hz (1 mm)
Shock resistance 30 g (11 ms)
Protection class IP67
MTTF 751  years acc. to SN 29500 (Ed. 99) 40
°C
Included in delivery BS1-CK40

Mounting instructions

Mounting instructions/Description
Distance D 120 mm
Distance W 75 mm
Distance S 120 mm
Distance G 150 mm
Distance N 1×B

NI25-CK40-LIU-H1141 | 20-04-2022 05-31 | Technical modifications reserved


Width active area 40 mm
B

Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com 2|3
Accessories

BSS-CP40 6901318
Mounting clamp for rectangular
housings 40 x 40 mm; material:
Polypropylene

Accessories

Dimension drawing Type ID


RKC4.4T-2/TEL 6625013 Connection cable, female M12, straight,
4-pin, cable length: 2 m, sheath
material: PVC, black; cULus approval;
other cable lengths and qualities
available, see www.turck.com

RKC4.301T-0.15-RSC4.334T/TXL 6631382 Extension cable, M12 female/male,


straight, 4-pin, cable length: 0.15m,
jacket material: PUR, black; cULus
approval; Adapter cable for sensors
with analog output on pin 2, for
connection to analog inputs of fieldbus
modules with 4-wire technology

Accessories

NI25-CK40-LIU-H1141 | 20-04-2022 05-31 | Technical modifications reserved


Dimension drawing Type ID
IM43-13-SR 7540041 Trip amplifier; 1-channel; input 0/4…
20 mA or 0/2…10 V; supply of 2- or 3-
wire transmitters/sensors; limit value
adjustment via teach button; three relay
outputs with one NO contact each;
removable terminal blocks; 27 mm
wide; universal voltage supply 20…250
VUC; further Limit value indicators are
described in our "Interface Technology"
catalog.

Hans Turck GmbH & Co. KG | 45466 Mülheim an der Ruhr, Germany | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com 3|3

You might also like