Check Valve Poppet Type Direct-Acting Cartridge - 500 Bar: RVF G1/4 To G3/8 RVF 9/16-18 UNF

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Version A Version R Check valve

poppet type
direct-acting
Cartridge – 500 bar
up to   45 l/min
RVF G1/4 to G3/8
up to 500 bar RVF 9/16-18 UNF
FUNCTION FEATURES
zz Check valves for screwing directly into the threaded connection of a manifold
Version A zz Flow-optimised spherical cap reduces pressure loss
zz Choice of 3 sizes ensures best possible adaptability to the system
zz Leakage-free poppet design for shut-off of system parts
zz Reverse-flow version: simple reversal of non-return functionality with no change
to cavity required
zz Sealing geometry is robust against usual contamination (see filtration)

Version R

SPECIFICATIONS*
Operating pressure: max. 500 bar
Nominal flow: RVF-G1/4-A-01-N-2 up to max. 30 l/min
RVF-G1/4-R-01-N-2 up to max. 20 l/min
RVF-G3/8-A-01-N-2 up to max. 45 l/min
RVF-G3/8-R-01-N-2 up to max. 30 l/min
RVF-9/16-18UNF-A-01-N-2 up to max. 30 l/min
RVF-9/16-18UNF-R-01-N-2 up to max. 20 l/min
Media operating temperature range: NBR: min. -30 °C bis max. +100 °C
FKM: min. -20 °C bis max. +120 °C
Ambient temperature range: NBR: min. -30 °C bis max. +100 °C
FKM: min. -20 °C bis max. +120 °C
The check valve is a direct-acting,
spring-loaded poppet type valve. Operating fluid: Hydraulic oil to DIN 51524 part 1, 2 and 3
When there is no flow through the valve, Viscosity range: min. 2.8 mm²/s to max. 800 mm²/s
the spring holds the spherical cap in Filtration: Class 20/18/15 according to ISO 4406 or
closed position and blocks the flow: cleaner
Version A: blocked direction port 2 → 1 Installation: No orientation restrictions
Version R: blocked direction port 1 → 2 Materials: Valve body: high tensile steel
The valve opens in the opposite
EN 5.179.1.1/08.19

Closing element: Roller bearing steel


direction when the inlet pressure is
Seals: NBR, FKM (optinal)
higher than the outlet pressure, including
the spring force: Cavity: G1/4, G3/8 and UNF 9/16-18
Version A: flow direction port 1 → 2 Weight: RVF1/4 = 0.005 kg
Version R: flow direction port 2 → 1 RVF3/8 = 0.010 kg
* see “Conditions and Instructions for Valves” in brochure 53.000
1
TYPICAL PERFORMANCE
Measured at:
ν = 34 mm²/s and Toil = 46 °C

RVF-G1/4-A RVF-G1/4-R
5 6

5
4

4
3
Δp [bar]

Δp [bar]
3

2
2

1
1

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 0 5 10 15 20
Q [l/min] Q [l/min]

RVF-G3/8-A RVF-G3/8-R
5 5

4 4

3 3
Δp [bar]

Δp [bar]

2 2

1 1

0 0
0 5 10 15 20 25 30 35 40 45 0 5 10 15 20 25 30
Q [l/min] Q [l/min]

RVF-9/16-18UNF-A RVF-9/16-18UNF-R
5 6

5
4

4
3
Δp [bar]

Δp [bar]

2
2

1
1
EN 5.179.1.1/08.19

0 0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 0 5 10 15 20
Q [l/min] Q [l/min]

2
DIMENSIONS
RVF/A RVF/R

Designation A B C D ØE ØF ØG ØH SW Torque*
[mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [Nm]
RVF-9/16-18UNF-R-01-.-. 9/16-18UNF 5.5 10 1 2 12 – – 5  8
RVF-G1/4-R-01-.-. G1/4 5.15  9.5 1 2 11.4-0.1 – – 5  8
RVF-G3/8-R-01-.-. G3/8 6.4 11.1 1.15 2.4 14.9-0.1 – – 7 15
RVF-9/16-18UNF-A-01-.-. 9/16-18UNF 4.8  9.6 1.2 2.4 12.5  8.6 2.2 – 10
RVF-G1/4-A-01-.-. G1/4 4.7   9.2 1.6 2.4 11.4-0.1  8.6 2.2 – 10
RVF-G3/8-A-01-.-. G3/8 6.7  11.5 2.4 3 14.9-0.1 10.8 3.1 – 15
*Notice:
Prevent valves from loosening by suitable measure.
Ensure the required surface finish at the O-ring support. Millimeters
An over-tightening torque may cause leakage! Subject to technical modifications

Form tools
CAVITY Tool Part No.
Caution: Installation dimensions only describe the RVF itself! Form tool RVF-9/16-18 UNF-A 4233343
Provide thread depth for fittings if required.
Form tool RVF-G1/4-A 4233341
Form tool RVF-G3/8-A 4233342

Millimeters
Subject to technical modifications
EN 5.179.1.1/08.19

Cavity U ØV ØW X Y
[mm] [mm] [mm] [mm]
G1/4 G1/4 11.7+0.1  8 7.5 10.5
G3/8 G3/8 15.2+0.1 10 9 12
9/16-18UNF 9/16-18UNF 12.8+0.1  8 7.5 10.5

3
MODEL CODE
RVF – G1/4 – A – X – N – 2
Basic model
Check valve

Threads
G1/4 = RVF 1/4
G3/8 = RVF 3/8
9/16-18 = RVF 9/16 UNF

Code, flow
A = from port 1 to 2
R = from port 2 to 1

Series
specified by manufacturer

Seals
N = NBR (standard)
V = FKM

Cracking pressure*
0 = no spring
2 = 0,15 bar (2 PSI)

*higher cracking pressures for realisation of preload


pressures are not intended for this series - alternatively see
our RV series

Standard models
Name Part no.
RVF-G1/4-A-01-N-2 3764907
RVF-G1/4-R-01-N-2 3764908
RVF-G3/8-A-01-N-2 3764909
RVF-G3/8-R-01-N-2 3764910
RVF-9/16-18UNF-A-01-N-2 3706961
RVF-9/16-18UNF-R-01-N-2 3706963
Other models on request
EN 5.179.1.1/08.19

NOTE HYDAC Fluidtechnik GmbH


The information in this brochure relates to Justus-von-Liebig-Str.
the operating conditions and applications D-66280 Sulzbach/Saar
described. For applications or operating
conditions not described, please contact the Tel: 0 68 97 /509-01
relevant technical department. Fax: 0 68 97 /509-598
Subject to technical modifications. e-mail: [email protected]
4