Frequency and Voltage Hz 50


Ratings
V 400
Maximum Working
Pressure
bar 7.5 10 13
3
Capacity at Nominal Working Pressure (FAD / ISO 1217-Annex C) m /min
19.5 17.9 14.0
Shaft Power at Nominal Working Pressure
kW 104.8 103.8 108.9
Idling Shaft Power
kW 27.2 27.0 28.3
CAPACITY & POWER CONSUMPTION

Nominal Working Pressure


bar 7.0 9.5 12.5
Minimum Working
Pressure
bar 5.5 5.5 5.5
Air-End Male Rotor Speed
rpm 2775 2330 2050
Fan(s) ON (IE4 Motor) / ISO 1217-Annex C
111.2 110.2 115.4
Fan(s) OFF (IE4 Motor) )
Maximum Package Power 108.2 107.2 112.4
at Nominal Working Fan(s) ON (IE3 Motor) / ISO 1217-Annex C
Pressure 112.3 111.3 116.6
kW
Fan(s) OFF (IE3 Motor)
109.4 108.3 113.6
Water Cooled (IE4 Motor) / ISO 1217-Annex C
108.2 107.2 112.4
Water Cooled (IE3 Motor) / ISO 1217-Annex C
109.4 108.3 113.6
Fan(s) ON (IE4 Motor) / ISO 1217-Annex C
5.70 6.15 8.24
Fan(s) OFF (IE4 Motor)
5.55 5.99 8.03
Fan(s) ON (IE3 Motor) / ISO 1217-Annex C
Specific Energy 3
kW/m /min 5.76 6.22 8.33
Consumption
Fan(s) OFF (IE3 Motor)
5.61 6.05 8.12
Water Cooled (IE4 Motor) / ISO 1217-Annex C
5.55 5.99 8.03
Water Cooled (IE3 Motor) / ISO 1217-Annex C
5.61 6.05 8.12
Drive System Direct Drive

Minimum Allowed Ambient Temp.


ºC +2 +2 +2
Maximum Allowed Ambient Temp.
ºC + 43 + 43 + 43
GENERAL

Compressed Air Temp. Rise Over Suction Temp.


ºC + 10 + 10 + 10
Heat Rejection to the Oil Cooler (ΔT)
kW 89.05 88.22 92.52
Heat Rejection to the After Cooler (ΔT)
kW 15.71 15.57 16.33
3
Cooling Air Flow Rate (All Fans) [Qa] m /h
25000 25000 25000
AIR-COOLED

Dimension of Air Outlet(s)


mm 1000x1122 1000x1122 1000x1122
Max.Cooling Air Pressure Drop
Pa 150 150 150
Cooling Air Temp Rise Over Ambient Temp.
ºC 10 - 15 10 - 15 10 - 15
Cooling Water Pressure Range
bar 2-8 2-8 2-8
Cooling Water Flow Rate at ΔT 25°C [Qw@25°C]
( Max. Permissible Inlet Water Temp [45°C] ) *
l/s 1.01 1.00 1.04
WATER-COOLED

Cooling Water Flow Rate at ΔT 30°C [Qw@30°C]


COOLING

( Max. Permissible Inlet Water Temp [40°C] ) *


l/s 0.84 0.83 0.87
[W]

Cooling Water Flow Rate at ΔT 40°C [Qw@40°C]


( Max. Permissible Inlet Water Temp [30°C] ) *
l/s 0.63 0.62 0.65

Cooling Water Flow Rate at ΔT 50°C [Qw@50°C]


( Max. Permissible Inlet Water Temp [20°C] ) *
l/s 0.50 0.50 0.52

Cooling Water Pressure Range


HYBRID COOLING (AIR-COOLING + WATER-COOLING)

bar 2-8 2-8 2-8


Cooling Water Flow Rate at ΔT 25°C [Qw@25°C]
( Max. Permissible Inlet Water Temp [45°C] ) *
l/s 0.85 0.85 0.89
WITH HEAT-RECOVERY SYSTEM

Cooling Water Flow Rate at ΔT 30°C [Qw@30°C]


( Max. Permissible Inlet Water Temp [40°C] ) *
l/s 0.71 0.71 0.74
[ HC ]

Cooling Water Flow Rate at ΔT 40°C [Qw@40°C]


( Max. Permissible Inlet Water Temp [30°C] ) *
l/s 0.53 0.53 0.56

Cooling Water Flow Rate at ΔT 50°C [Qw@50°C]


( Max. Permissible Inlet Water Temp [20°C] ) *
l/s 0.43 0.42 0.44

PAGE1/2
30/01/2018
MA SD 110 MA SD 110-W MA SD 110-HC
Rev. No: 06

Main Motor Rated Output


Power
kW 110 110 110
Main Motor Efficiency (IE4)
% 96.8 96.8 96.8
Main Motor Efficiency (IE3)
% 95.8 95.8 95.8
Main Motor
Mounting
IMB B35 B35 B35
Main Motor Frame
Size 315 S/M 315 S/M 315 S/M
Main Motor Degree of
MOTOR
MAIN & FAN MOTORS DATA

Protection
IP IP55 IP55 IP55
MAIN

Main Motor Pole


Number
#P 4 2 4
Main Motor Rated Speed (Synchronous Speed at 50Hz)
rpm 1500 3000 1500
Main Motor Rated Speed (Synchronous Speed at 60Hz)
rpm 1800 3600 1800
Main Motor Insulation
Class F F F
Main Motor Temperature Rise
Class B B B
Number of
# 1 1 1
Not Applicable to [W] Version

Fans
Fan Motor(s) Rated Input Power (All Fans)
kW 2.94 2.94 2.94
FAN MOTOR(S)

Fan Motor(s) Degree of Protection


IP IP55 IP55 IP55
Fan Motor(s) Pole Number
#P 4 4 4
Fan Motor(s) Rated Speed (Synchronous Speed at 50Hz)
rpm 1500 1500 1500
Fan Motor(s) Rated Speed (Synchronous Speed at 60Hz)
rpm 1800 1800 1800
Oil Quantity
l 45 45 45
GENERAL TECHNICAL DATA

Residual Oil Content in Compressed Air


mg/m 3
≤3 ≤3 ≤3
Compressed Air Outlet
R 2" 2" 2"
Compressor Package Inlet Power Cable Minimum Cross-Section Area
(This recommended cross-section area is up to 25m Power Cable)
mm2 3 x 120 +70 3 x 120 +70 3 x 120 +70

Noise Level (ISO 2151, ± 3dB (A))


dB (A) 79 79 79
Compressor Weight (approx.)
kg 2640 2640 2640
Compressor Dimensions ( L x W x H )
mm 2525x1440x2037 2525x1440x2037 2525x1440x2037
Soft Starter
ADDITIONAL FEATURES

Optional

Oil-Heater
Optional

IE4 Efficiency Main Motor


Optional

Main Voltage / Frequency Rating Other Than


Optional
Standard
Water Separator with Automatic Drain
Standard
System
Please Contact DALGAKIRAN KOMPRESOR for Lower / Higher Operating Pressures

Absolute Inlet Pressure 1 bar(a) All rights reserved. MEGA AIR has the legal
Relative Air Humidity 0% rights to change this specification without an announcement.
Air Inlet Temperature 20°C
REFERENCE
CONDITIONS

MAQ OIL
Standard Oil Type **

Set Point Thermostatic Valve 71°C www.mega-air.si


(*) +10°C / Minimum Water Inlet Temp.
(**) Special lubricants for different applications are available, please contact DALGAKIRAN KOMPRESOR