RHP600 - RHP750 Steam Boiler Series
RHP600 - RHP750 Steam Boiler Series
RHP600 - RHP750 Steam Boiler Series
RHP600 – RHP750 Steam Boiler Series
Features
• Maximum safety relief valve setting 150psi
• All boilers are manufactured in accordance with the
requirements of the A.S.M.E. Boiler and Pressure Vessel
Code and A.S.M.E. CSD‐1. Each boiler bears the National
Board Stamp “S”.
• High quality saturated steam, operating pressure range
0 – 135psig
• Heavy duty carbon steel pressure vessel. Vessel jacket and
electrical enclosure made from black painted carbon steel
• Large selection of optional equipment
Standard Equipment of Each Boiler Includes:
• A.S.M.E. pressure relief valve
• Two (2) boiler bottom blowoff valves (one quick‐opening
and one slow opening) as per A.S.M.E. Code B31.1
• 4” flanged class 150# carbon steel steam outlet valve
• High pressure feed pump in RHPH‐ and RHPHC‐models
• One (1) primary high pressure cutoff control with automatic
reset and one (1) secondary high pressure cutoff control
with manual reset
• One (1) primary low water cutoff control with automatic
reset and one (1) secondary low water cutoff with manual
reset
• PID‐step controller with 10 heating stages
Applications • Digital readout of the operating pressure
• Magnetic contactors
• Dry Cleaning • Internal branch circuit fusing
• Food Service • Main supply power distribution block
• Laboratories • Indicator lights for POWER, REFILLING, HEATING, ALARMS
• Automotive Industry and Automatic Boiler Blowoff Status
(1) (2)
HEATING STEAM BHP VOLTAGE PHASE NUMBER OF SHIP WT. PRESSURE VESSEL OPERATING Steam Outlet
POWER CAPACITY HEATING CAPACITY PRESSURE RANGE Size
50/60Hz STAGES GAL. (L) psig (bar)
(3)
kW lbs/hr (kg/hr) lbs (kg)
600 KW 2049 (928) 60 380/415/480/600 3 10 2,780 (1259) 179 (677) 0‐135 (0 – 9.3) 4” FLANGED
750 KW 2561 (1160) 75 380/415/480/600 3 10 2,820 (1278) 179 (677) 0‐135 (0 – 9.3) 4” FLANGED
(1)
Each boiler model requires two (2) power supplies:
Model Number Key Primary heating power and secondary control voltage.
Nominal control voltage is 120V, 50/60Hz. Boiler models
rated for 380V and 415V are equipped with control voltage
transformers that require 220/240V applied to their primary
Safety Relief side in order to provide the 120V AC control voltage to the
Feed Water Options: Valve Setting: boiler. As an option, all boiler models can be equipped with
Blank = Solenoid Valve A = 15psi (1.03bars) control voltage transformers so that only the heating power
H = Solenoid Valve + Pump F = 100psi (6.9bars)
H = 150psi (10.3bars) supply needs to be connected to the boiler.
(2)
Condensate Tank: On boiler equipped with condensate tank, add 250lbs
Blank = No Condensate Tank Power Supply:
C = Boiler with Condensate Tank 3 = 3‐Phase (113kg) to shipping weight
(3)
The STEAM CAPACITY listed above is based on the
Boiler Power in kW Power Supply evaporation rate from and at 212°F, at 0 psig. If the boiler
Voltage: feed water temperature is 50°F, then the STEAM CAPACITY
G = 380V
J = 415V for each model listed above is approximately 15% lower.
Example: RHPHC750K3H = RHP‐Series boiler with pump and condensate tank, K = 480V
M = 600V
750kW heating power, power supply 480V, 3ph, safety valve set to 150psi.
Reimers Electra Steam, Inc. 6/4/2014 PAGE 1 RHP600 – 750 Brochure Rev. 2
Electrical Specifications
HEATING AMP MIN REQ. INTERNAL NUMBER & NUMBER & SIZE OF POWER SUPPLY
POWER DRAW N.E.C. ELEMENT SIZES OF ELEMENTS
FREQU. FIELD
VOLTAGE
PHASE
CONFIG.
POWER
SUPPLY
TERMINAL
V
TORS
(RES. LOAD) MAX.
AWG CONDUCTOR
kW A A (mm2) SIZE
600 380 3 50 911.6 1,140.0 8 (8.35) 20 x 75A 20 x 30kW, 380V, 3ph 12 x 350MCM 2
415 3 50 834.7 1,044.0 8 (8.35) 20 x 50A 20 x 30kW, 415V, 3ph 12 x 300MCM 2
480 3 60 721.7 902.0 8 (8.35) 20 x 50A 20 x 30kW, 480V, 3ph 12 x 250MCM 2
600 3 60 577.4 722.0 10 (5.30) 20 x 50A 20 x 30kW, 600V, 3ph 6 x 500MCM 1
750 380 3 50 1139.5 1425.0 8 (8.35) 25 x 75A 25 x 30kW, 380V, 3ph 12 x 500MCM 2
415 3 50 1043.4 1305.0 8 (8.35) 25 x 50A 25 x 30kW, 415V, 3ph 12 x 500MCM 2
480 3 60 902.1 1128.0 8 (8.35) 25 x 50A 25 x 30kW, 480V, 3ph 12 x 350MCM 2
600 3 60 721.7 903.0 10 (5.30) 25 x 50A 25 x 30kW, 600V, 3ph 12 x 250MCM 2
Construction
SAFETY RELIEF VALVE
STEAM STOP VALVE
PRIMARY PRESSURE
10 HEATING STAGES SAFETY LIMIT CONTROL
STEP CONTROLLER WITH AUTOMATIC RESET
WITH FIRST ON – FIRST FUNCTION
OFF SWITCHING
SEQUENCE (FOFO)
SECONDARY PRESSURE
PID ‐ OPERATING SAFETY LIMIT CONTROL
PRESSURE WITH MANUAL RESET
CONTROLLER FUNCTION
HONEYWELL T775U
ELECTRONIC BOILER
CONTROLLER: TWO (2) INSPECTION &
‐ LOW WATER & HIGH CLEANOUT OPENINGS
PRESSURE LOCKOUT 3” NPT AS PER
‐ AUTOMATIC REFILL
‐ AUTOMATIC FLUSH & A.S.M.E. CODE
DRAIN FUNCTION
‐ BOILER MONITORING
HEATING ELEMENTS,
30kW, 304 STAINLESS
STEEL SHEATHING,
SHELL INSULATION: 2” CARBON STEEL
FIBERGLASS, FLANGES CLASS 150#
4” THICK
ELECTRICAL
ENCLOSURE, NEMA1, SHELL WRAPPER, BLACK
BLACK PAINTED, PAINTED, 16GAGE
12GAGE CARBON STEEL CARBON STEEL
Reimers Electra Steam, Inc. 6/4/2014 PAGE 2 RHP600 – 750 Brochure Rev. 2
PRESSURE GAUGE WITH STEAM OUTLET VALVE: 4”
3‐WAY INSPECTION VALVE FLANGED
CLASS 150#
PRESSURE TRANSDUCER
FOR PID‐OPERATING
AUTOMATIC WATER PRESSURE CONTROLLER
REFILL & PRIMARY LOW
WATER CUT‐OFF
CONTROLLER WITH SECONDARY LOW WATER
AUTOMATIC RESET CUT‐OFF SENSOR FOR
FUNCTION, MCDONNEL & BOILER CONTROLLER
MILLER MODEL 157S
WATER LEVEL GAUGE
BOILER FEED WATER
EXTERNAL WATER SHUTOFF VALVES
COLUMN DRAIN
BALL VALVES ¾” NPT
BOILER BOTTOM
BLOWOFF VALVES:
BOILER FEED WATER
1 X 1‐1/4” NPT QUICK‐
OPENING BALL VALVE SOLENOID VALVE ON
& RHP‐ & RHPH MODELS
1 X 1‐1/4” NPT SLOW‐
OPENING Y‐VALVE
OR HIGH PRESSURE BOILER
MOTORIZED BALL VALVE
FEED WATER PUMP
IF BOILER IS EQUIPPED
WITH AN AUTOMATIC
BOILER BLOWOFF OPTION
FIELD TERMINAL FOR
CONTROL VOLTAGE
FIELD TERMINALS FOR HOOKUP;
POWER CIRCUITS; NOT NEEDED WHEN A
NUMBER AND SIZE OF CONTROL VOLTAGE
TERMINALS PROVIDED TRANSFORMER (OPT1011)
PER CIRCUIT AND PHASE
DEPENDS ON BOILER
BOILER FEED WATER
MODEL
PUMP FUSING;
(REFER TO ELECTRICAL
UL CLASS RK5
SPECIFICATION TABLE ON
PAGE 2)
HEATING ELEMENT
CIRCUIT FUSING;
UL CLASS K STANDARD
OR
ELECTRICAL ENCL. UL CLASS J OPTIONAL
COOLING FAN
HEATING ELEMENT
CIRCUIT MAGNETIC
CONTACTORS, RATED
HEATING ELEMENT
MIN. 250,000 CYCLES AT
WIRING,
FULL RATED ELECTRICAL
RATED 125°C MINIMUM
LOAD
Reimers Electra Steam, Inc. 6/4/2014 PAGE 3 RHP600 – 750 Brochure Rev. 2
Dimensional Drawings (approximate)
RHP/RHPH600 – RHP/RHPH750
Reimers Electra Steam, Inc. 6/4/2014 PAGE 4 RHP600 – 750 Brochure Rev. 2
RHPHC600 – RHPHC750
Reimers Electra Steam, Inc. 6/4/2014 PAGE 5 RHP600 – 750 Brochure Rev. 2
Optional Equipment
1. Timer Controlled Boiler Blowoff System, #OPT1001: Boiler Blowoff Valve
Programmable installed between
Digital Timer boiler and blow down
At the end of boiler blowoff:
‐ Boiler Blowoff Valve closes
When boiler blowoff time is reached: ‐ Boiler control circuits turn on automatically
‐ Boiler control circuits turn off automatically ‐ The water level in boiler restores
‐ Boiler Blowoff Valve opens ‐ Boiler resumes operation automatically
Program boiler blowoff
day time and duration
2. Automatic Flush & Drain System, #OPT1016
Electronic Boiler
Controller
Boiler Blowoff Valve
installed between
boiler and blow down
Steam pressure drops below
setting of blowoff‐pressure At the end of boiler blowoff,
controller (15psig or less). valve closes automatically.
Boiler Blowoff
Power Enable
OFF ON
3. Blowdown Tank: #BTANK‐750‐USA & BTANK‐750‐CRN
- Designed in accordance with the National Board Guide for Blowoff Vessels NB‐27
‐ Designed and manufactured in accordance with the requirements of the A.S.M.E. Boiler and Pressure Vessel Code Section VIII, Division 1.
Each Blowdown tank bears the National Board Stamp “U”. The design pressure as per NB‐27 is 50psig.
‐ BTANK‐750‐CRN meets also the Canadian Standard CSA‐B51.1 Boiler, Pressure Vessel and Pressure Piping Code
#BTANK‐750‐USA for all #BTANK‐750‐CRN for Typical Blowdown Tank Installation; RHPH750 model shown with
countries except Canada Canada BTANK‐750‐CRN
4. Control Voltage Transformer 5. Timer Controlled Boiler
On/Off #OPT1017
When using this option, only the main power
supply is required to operate the boiler.
Boiler Voltage Transformer Option Part Program timer
Number to turn boiler
ON/OFF
380V OPT1011 – 380RHP automatically
415V OPT1011 – 380RHP
480V OPT1011 – 480RHP
600V OPT1011 – 600RHP