Turbine RAS - Back Pressure Turbine 4
Turbine RAS - Back Pressure Turbine 4
Turbine RAS - Back Pressure Turbine 4
Subject : Techno-commercial Offer for the supply 3.7 MW/ 4 MW Back pressure TG Set.
Reference: Your enquiry for back pressure Turbine dated 23Jan 2020
Dear Sir,
We thank you for your enquiry. Further to the same, we are pleased to submit herewith our
techno-commercial offer for the supply of 3.7 MW/ 4 Mw TG set for your kind perusal.
We hope you will find the same in line with your requirements. However, should there be any
clarifications, please feel free to get in touch with us.
Thanking you and assuring you of our best attention at all times.
Yours truly,
for TRIVENI TURBINE LTD.
Triveni Turbines is an AS 9100D (Based on and including ISO 9001:2008) and ISO 14001:2004
certified company. As a commitment to environment we have laid out our environment policy
which will be practiced during our operations, manufacturing and other areas of operation.
All our products will confine to broad guidelines laid out by our EOHS policy.
Authorized Signatory
We at Triveni Turbine Limited manufacturing Steam Turbines and related products including
the accessories are committed to:
• Produce the product and provide services to enhance the Customer satisfaction by
ensuring prevention of pollution, reduction of waste, conservation of resources and
creating safe working environment by ensuring prevention of injury and ill health
• Comply will all applicable legal and other requirements with relation to EOHS.
• Communicate the policy effectively to all persons working under the control of the
organization including relevant interested parties such as Sub contractors, Suppliers,
Transporters and Customers.
EXECUTIVE DIRECTOR
Most preferred supplier, with a market share of over 60% in India in the range up
to 30MW
Over 2500 installations across the globe in over 30 countries in all industry
segments
Over 500 turbines in process co-generation plants and nearly 100 turbines in
biomass based IPPs
Industry Bench Mark Delivery time. Helps our customers commission their power
plants faster
Best in class manufacturing plant in Bangalore with fleet of 4 Axis / 5 Axis
machine. Manufacturing capacity of 150 turbines per year
Every turbine is put through a Mechanical Steam Run Test (at factory, before
dispatch) at Full speed to test vibration, safety trip etc.
SCHENK High Speed Vacuum Tunnel balancing for precise dynamic balancing
of large rotors. Ensures operation reliability
24 x 7 Service centers closer to our customers - 13 service offices across India
with over 150 service personnel. We respond within 8 hours of an emergency call
Life time support for spares and services to maximize the return on investment.
Refurbishing solutions offered up to 150 MW for any make of turbine to enhance
efficiency, availability and reliability.
A decade old Research and Development department for continuous
improvement of existing models and development of new models. Associated
with renowned design houses from USA – Impact Technologies LLC and
Concepts NREC.
SECTION – I TECHNICAL
Chapter – 9 : QAP
SECTION – II COMMERCIAL
Steam Turbine
Multistage, Nozzle governed, Horizontal spindle, two bearings, Impulse type cum back
pressure steam Turbine with:
- Hydraulically operated Stop & Emergency Valve with integral steam strainer for inlet
- Hydraulically operated Throttle/Governing valves for inlet steam flow control.
Gearbox
- Double helical, single reduction Gearbox with hardened & ground gears. The design will be
with a service factor of 1.5 as per AGMA 6011-I03.
Couplings
- Non-lubricated, steel laminated, flexible type, high-speed coupling and low speed couplings
with coupling guards.
Governing System
- Electronic governor complete with electro-hydraulic actuator and magnetic speed pick ups.
- Hydraulic accumulator
- Control oil filter
- Interconnecting control oil piping
Lubrication system
Forced feed lubrication system, common for Turbine, Gearbox & Alternator comprising of:
- Lube oil tank (combined with turbine base plate) provided with cleaning doors and air
breather
- Main Oil Pump (MOP) driven by gearbox low speed shaft
- A.C. Motor driven auxiliary oil pump for flooding the bearings during start-up and wired
through a pressure switch for automatic cut-in and cut-out in the event of main oil pump
not supplying required quantity of oil.
- D. C. Motor driven Emergency lube Oil Pump (EOP) with auto cut-in & cut-out facility
- A. C. Motor driven Auxiliary Control Oil Pump (ACOP) (1 working + 1 standby)
- Suction strainers for MOP, AOP, EOP.
- Pressure relief valves for discharge of MOP, AOP, MCOP, ACOP and lube oil line
- Oil coolers (1 working + 1 standby) with on-line changeover arrangement
- Oil filters (1 working + 1 standby) with on-line change-over arrangement
- AC motor driven oil vapour extractor mounted on oil tank
- Pressure regulating valve to achieve desired lube oil pressure
- Set of complete lube oil piping within the limits of the turbine base frame and sufficient to
meet the requirement of the ordered equipment. (The lube oil pipe will be SS downstream
the filter and CS upstream of filter)
Accessories
- Motorized barring gear arrangement.
- Base plate for turbine and gearbox
- Vibration monitoring system- High speed train – Shinkawa make
- Insulation for Turbine hot parts (lagging & cladding)
II. ELECTRICAL
AC Generator
AC Generator shall be complete with following:
- Brush-less exciter
- Air coolers
- Twin bearings
- Anti-condensation heaters
- Water leakage detector– 1 per cooler
- Lube oil flow regulator – 1 per bearing
- Hand trip:
Type : Block & dump valve in trip oil line
Operation : Local hand lever
- Solenoid trip:
Type : Solenoid operated block & dump valve
Operation : De-energise to open & trip
I. MECHANICAL
STEAM TURBINE
Design :
Oil system:
- Oil:
- Oil cooler:
Type : Centrifugal
Capacity : 400 m3/Hr
Driver : AC Motor
Mounting : Flange
Bearings:
- Journal Bearings
Type : Tilting pad
Material : White metal - Babbitt
- Thrust Bearings
Type : Tilting pad
Material : White metal - Babbitt
Governing System:
- Governor:
Type : Electronic (Woodward 505D)
Inputs (critical) : 2 speeds from MPU-1 & 2
Control range : 80 to 110% of rated speed
Control accuracy : As per NEMA class D
Speed droop : 3 to 6% (programmable)
Power supply : 110 V DC
Accessories : 2 Magnetic speed pick-ups (MPU)
Enquiry Reference: WMQ2001399 Page 11 of 45
Project: M/s RA Shaikh Paper Mills Pvt Ltd.
Power rating: 3.7 Mw
1 electro-hydraulic actuator
- Hydraulic Accumulator:
Type : Bladder
Working fluid : Pre-charged Nitrogen
Capacity : 28 Liters
GEARBOX
Design:
Type : Double helical, Single reduction
S.F. : 1.3
Accessory : Air breather
COUPLINGS
ACCESSORIES
- Barring gear:
Type : auto engage & disengage
Driver : AC motor
GENERAL
AC GENERATOR
Design :
Bearings :
Type : Sleeve
Accessory : Temperature gauge
Air coolers :
Cooling method : CACW
Capacity : 2 x 60%
Cooler tube material : SS-304
Mounting : Top
Features :
- Compounding
- Auto PF controller
- Remote voltage control
- Auto-Manual follow-up
- Under frequency protection
- Field flashing provision
AVR cum excitation panel shall be complete with generator voltmeter, field voltmeter, field
ammeter, PF meter, Auto/Manual selector switch, AC supply & DC supply on /off control
switches, indicating lamps and space heater with thermostat.
General:
Type : Simplex, dead front & free standing
Dimensions in mm : 800 (L) x 1000 (D) x 2310 (H) Approx
Weight : 450 KG Approx.
General:
Type : Simplex, dead front & free standing
Dimensions in mm : 1000 (L) x 1000 (D) x 2200 (H)
Weight : 800 KG
- Synchronising equipment
Double voltmeter : 1 No.
Double frequency meter : 1 No.
Synchroscope : 1 No.
Check synchronizing
Relay : 1 No.
Aux. relays for
Synchronising scheme : 1 Set
General:
Type : Desk & free standing
Dimensions in mm : 1200 (L) x 1100 (D) x 2200 (H)
Weight : 750 KG
- Lightning arrestor
Discharge current : 10 kA
Quantity : 3 Nos. (1 per phase)
- Surge capacitor
Capacitance per phase : 0.25 µF
Quantity : 3 Nos. (1 per phase)
- Potential transformers
For Quantity Secondary output Class
Protection 3 Nos. 110 V 3P
Metering 3 Nos. 110 V 0.5
Excitation 1 No. 220 V +/-5%
regulation
The panel shall be complete with AC supply on /off control switch, illuminating lamp with
limit switch for each PT compartment, indicating lamps and space heater with thermostat.
General :
Type : Simplex, modular & free standing
Terminal box : To suit HT Cables
Material of busbars : Aluminium
Dimensions in mm : 1800 (L) x 1650 (D) x 2200 (H)
Weight : 1,000 KG
Operation : Manual.
Enquiry Reference: WMQ2001399 Page 16 of 45
Project: M/s RA Shaikh Paper Mills Pvt Ltd.
Power rating: 3.7 Mw
No. of poles : One
Limit switches : 2 Nos. (for on / off positions)
- Earth connection
Type : Porcelain insulated 12 mm terminal studs
Quantity : Two Nos.
- Current transformers
For Quantity Secondary output Class
Differential 6 Nos. 1A PS
protection
Earth fault 1 No. 1A 5 P 10
protection
Metering 3 Nos. 1A 0.5
Compounding 1 No. 1A 1
The panel shall be complete with AC supply & DC supply on /off control switch,
illuminating lamp with limit switch for each PT compartment, indicating lamps and space
heater with thermostat.
General:
Type : Simplex, dead front & free standing
Terminal box : To suit HT Cables
Material of busbars : Aluminium
Dimensions in mm : 1500 (L) x 1000 (D) x 1400 (H)
Weight : 1,000 KG
BATTERY
Type : Maintenance Free
Capacity : 200 AH
Rating : 110 V, DC
Volt per cell : 2 V, DC
No. of cells : 55
- Battery charger
Quantity : One float & one float cum boost charger
Input : 240 V, 1 phase, 50 Hz, AC supply
Output : 15 A, 110 V DC (Float charger)
20 A, 110 V DC (Float cum boost charger)
Voltage regulation : +/- 1% from no-load to full load
Operation mode : Auto / Manual
- DC distribution system
Panel shall be provided with feeders for:
DC motor starter panel : 1 No.
Relay panel : 1 No.
Generator control panel : 1 No.
AVR cum excitation panel : 1 No.
Turbine control panel : 1 No.
Spare : 2Nos.
General :
Type : Simplex, dead front & free standing
Dimensions in mm : 1200 (L) x 1000 (D) x 1800 (H)
Weight : 300 KG
AC MOTORS
Type : Induction
Winding connection : Delta
Duty : Continuous
Enclosure : IP-55
Cooling : TEFC
Insulation : Class “F”
Power supply : 415 V, 3 Phase, 50 Hz
Speed / No. of poles : To suit driven equipment
DC MOTOR
Type : Shunt field
Duty : Continuous
Enclosure : IP-55
Cooling : TEFC
Insulation : Class “F”
Power supply : 110 V
Speed : 1440 RPM
The panel shall be complete with AC supply & Dc supply on /off control switches,
indicating lamps and space heater.
- Incoming feeder complete with switch-fuse unit, voltmeter, ammeter and indicating
lamps
- 2 step resistance starter for EOP motor complete with switch-fuse unit, contactor,
overload relay, ammeter, indicating lamps & pushbuttons.
- Pressure Switch
Sensor type : Bellows
Material of case : Die cast aluminium
Material of bellows : SS-304
- Pressure Transmitter
Type : 2 wire, capacitance & electronic
Input : Direct
Output : 4 – 20 mA
Material for process
connection internals : SS-304
- Solenoid Valve
Power supply : 110 V DC
Operation : De-energise to open
Type : 2 way, universal ports
- Level Switch
Type : Magnetic float
Material of body & float : AISI-304
Material of case : Die cast Aluminium
- Temperature Scanner
Power supply : 230 V, AC, Single phase
Input : PT-100, 3 wire RTD
Display : Channel No. & bearing / winding
temperature
Display mode : Auto / Manual
Scan rate : Programmable
Accuracy : +/- 1 Deg.C
- Alarm Annunciator
Type : Modular, plug-in cards, interchangeable
Input protection : Optical isolation provided through opto couplers
Colour of window : Milky white (pre-trip alarm)
Red (Trip alarm)
***
As applicable
PERFORMANCE
Inlet Steam Pr. (kg/cm2g) 67
Note:
1. The above consumption data apply at steady state conditions, with the control valve
fully open, deposit free blading and clean surface of cooling equipment in accordance
with the Triveni performance Test Procedure which is based on the IEC PART-II code.
2. This consumption does not include the power and steam requirements of the
condensing plant and auxiliary equipments. Instrumentation tolerance of +or- 3% is
allowed as per the international testing practices.
3. The data furnished are based on nominal steam parameters at turbine inlet, extraction
and exhaust flange.
4. Steam quantity should be maintained at inlet and extraction points for guarantee point
as mentioned elsewhere in the bid.
5. The following are not included in the auxiliary power consumption furnished in
Auxiliary power guarantee.
a) All standby equipments.
b) All electrical actuators and motorized valves
c) Other intermittent equipments
B. INSTRUMENTATION AIR
C. AC POWER
Note : All utility figures mentioned above are indicative only. The actual requirement shall
be furnished during detailed engineering.
LIMITS OF TENDER:
The offer is complete within the following limits beyond which Purchaser shall arrange any and
all equipments:
EXCLUSIONS:
The following items are not included in sellers scope of supply and shall be arranged by
purchaser:
CHAPTER – 7
LIST OF SUB-VENDORS
SL
ITEM MAKE / VENDOR
NO
Southern Lubrication/ Fil Sep /Cenlube/SKF /Lincoln
Separate Lube Oil
1 Helios
System
Note :
The aforesaid list is for indicative purpose only. TTL's scope of supply is as per the 'Chapter –I –
Scope Of Supply of this offer document'.
NOTE :
1. Drawings shall be submitted for information / approval within 8 to 12 weeks from date of
receipt of technically & commercially clear purchase order/LOI along with advance. You
shall approve all drawings submitted for approval within a period of 15 days of submission
failing which our delivery will get affected.
2. Final drawings and documents shall be submitted along with supply of equipment.
NOTE : 1. Material test certificates from manufacturers shall be submitted for major
components of turbine and other bought-out items along with supply.
2. We have not envisaged any “customer hold point” in QAP and delivery & price
quoted are on the same basis.
Technically pure steam is of such quality, that it does not cause deposits in the steam pre-
heaters, in the fittings, heaters as well as in the turbine, which might require the intentional
shut-down of the boiler or some part of the equipment, for their cleaning, outside of the normal
equipment maintenance program.
The recommended or limit values of the purity of steam are stated in the following table. The
values are given in the maximal allowable day average concentrations. The concentration of the
chlorine ions may be max. 3 µg.l-1.
NOTE: The measurement of the electrical conductivity γ at 250 C (µS/cm-1) must be done
without the presence of operational chemical agents, e.g. ammonia or hydrazine,
which tends to increase the conductivity. This is why the measurement of
specific electrical conductivity has to be done after the flow of the sample
through the strong acidic H-katex, which is the filter that keeps all cations of the
chemical compounds. By the filtration chemically pure water can be obtained.
Na + K, ppb, max.
Upto 800 PSIG 20 20
801 to 1450 PSIG 10 10
1451 to 2400 PSIG 5 5
Over 2400 PSIG 3 3