Remote I/O module

4 channel RTD input


on RS-485 network
Via monte Nero, 40/B – 21049 TRADATE (VA) ITALY
Phone: +39 (0)331841070 Fax:+39 (0)331841950 - e-mail:[email protected] - www.datexel.it
DAT 3014
FEATURES
- Field-Bus remote data acquisition
- RS-485 Master/Slave communication type
- MODBUS RTU/ASCII protocol
- 4 channel input
- RTD, Resistance and Potentiometer configurable input
- Watch-Dog Alarm
- Remotely Configurable
- 2000 Vac 3-way Galvanic Isolation
- High Accuracy
- EMC compliance – CE mark
- DIN rail suitable mounting - EN-50022 compliance

GENERAL DESCRIPTION
The DAT 3014 device is able to acquire up to 4 analog input signals. Data values are transmitted with MODBUS RTU/ASCII protocol on the RS-485 network
(RS-232 interface is available).
It is possible to connect RTD , Potentiometers or Resistance signals.
By means of a 16 bit converter, the device guarantee a high accuracy and a stable measure versus time and temperature.
To ensure the plant safety, two Watch-Dog timer alarms are provided.
The 2000 Vac isolation between input, power supply and serial line removes eventual ground-loop effects, allowing the use of the device even in the heavy
environmental conditions.
DAT 3014 is in compliance with the Directive 2004/108/EC on the electromagnetic compatibility.
The device is housed in a rough self-extinguishing plastic container which, thanks to its thin profile of 17.5mm only, allows a high density mounting on EN-50022
standard DIN rail.

COMMUNICATION PROTOCOLS
The DAT3014 is designed to work with the MODBUS RTU/ASCII protocol: standard protocol in field-bus; allows to directly interface DAT3000 series devices to
the larger part of PLCs and SCADA applications available on the market.
For the protocol instructions, see the relative User Guide.

USER INSTRUCTIONS
Before to install the device, please read the “Installation Instruction” section.
If the module configuration is unknown, it can be hardly to establish a communication with them; connecting the INIT terminal to the GND terminal (ground), at
the next power-up the device will be auto-configured in the default settings (see Operating User Guide).
Connect power supply, serial bus and analog inputs as shown in the “Wiring” section.
The “PWR” LED state depending to the working condition of the device: see the "Light Signalling" section to verify the device working state.
To perform configuration and calibration operations, read the instructions in the Operating User Guide.
To simplify handling or replacing of the device, it is possible to remove the wired terminals even with the device powered.

TECHNICAL SPECIFICATIONS (Typical @ 25 °C and in the nominal conditions)


Input type Min Max
Input Calibration (1) Power Supply
RTD 2 or 3 wires RTD ±0.05 % f.s. Supply Voltage 10 .. 30 Vdc
Pt100 -200°C 850°C Res. ±0.05 % f.s. Current consumption 30 mA @ 24 Vdc
Pt1000 -200°C 200°C Polarity inversion protection 60 Vdc max
Pot. ±0.05 % f.s.
Ni100 -60°C 180°C
Ni1000 -60°C 150°C Isolation
Linearity (1)
Input – RS485 2000 Vac 50 Hz, 1 min.
RTD ±0.1% f.s.
Supply – Input 2000 Vac 50 Hz, 1 min.
RES. 2 or 3 wires CJC Thermal drift Supply – RS485 2000 Vac 50 Hz, 1 min.
Low 0Ω 500 Ω Full Scale ± 0.02 %/ °C
High 0Ω 2000 Ω Lead wire resistance influence (1) Temperature & Humidity
Operating temperature -10°C .. +60°C
RTD/res.3 wires 0.05 %/Ω (50 Ω max balanced)
Storage temperature -40°C .. +85°C
POT. (nom. value)
Humidity (non condensing) 0 .. 90 %
Low 20 Ω 500 Ω RTD excitation current
High 20 Ω 2000 Ω Typical 0.350 mA Housing
Material Self-extinguishing plastic
Thermal drift (1) Mounting EN-50022 DIN rail
Full scale ± 0.005 % / °C Weight ~ 150 g.
Sample time 0.5 ÷ 2 sec. EMC ( for industrial environments )
Data Transmission Immunity EN 61000-6-2
Baud Rate 38.4 Kbps Emission EN 61000-6-4
Max. distance 1.2 Km
Warm-up time 3 min.
(1) Referred to input Span (difference between max. and min. values)
INSTALLATION INSTRUCTIONS WIRING
ANALOG INPUT WIRING
The DAT 3014 device is suitable for fitting to DIN rails in the vertical position.
For optimum operation and long life follow these instructions: RTD/RES 2 WIRES
INPUT 0 INPUT 1 INPUT 2 INPUT 3
When the devices are installed side by side it may be necessary to 1 4 7 10
separate them by at least 5 mm in the following case:
- If panel temperature exceeds 45°C and at least one of the overload
conditions exist. 2 5 8 11

Make sure that sufficient air flow is provided for the device avoiding to place 3 6 9 12
raceways or other objects which could obstruct the ventilation slits. Moreover
it is suggested to avoid that devices are mounted above appliances
generating heat; their ideal place should be in the lower part of the panel. RTD/RES 3 WIRES
Install the device in a place without vibrations.
INPUT 0 INPUT 1 INPUT 2 INPUT 3
Moreover it is suggested to avoid routing conductors near power signal 1 4 7 10
cables (motors, induction ovens, inverters etc...) and to use shielded cable
for connecting signals.
2 5 8 11

3 6 9 12
CABLING

SHIELD POTENTIOMETER
POWER INPUT 0 INPUT 1 INPUT 2 INPUT 3
D+ SUPPLY
10÷30 V 1 4 7 10
D-
RS -485 V- V+
2 5 8 11

INIT
3 6 9 12
B
C
D

J
I
A

NOTE: input channels are not isolated between them 3 6 9 12 = Ref.

RS-485 NETWORK WIRING RS-232 NETWORK WIRING

A (-) RS-485 E TX
D- RX RS-232
network
1
2
3

7
8
9
4
5
6

RX
1

B (+) F
0
1

2
1

TX
D+
C
GND
C
GND
GND
INPUT 0
INPUT 1 INIT WIRING
POWER SUPPLY WIRING
INPUT 2
INPUT 3 INIT
+V D
J +
10÷30 Vdc ON: short-circuit
- to GND

LIGHT SIGNALLING C
I
-V GND
LED COLOUR STATE DESCRIPTION
PWR GREEN ON Device powered
OFF Device not powered / Wrong RS-485 cabling.
ISOLATION STRUCTURE
Communication in progress (blink frequency
FAST BLINK depends to baud-rate)
1 second BLINK Watch-Dog Alarm condition

ANALOG RS485
INPUTS (RS232)
MECHANICAL DIMENSIONS (mm)

POWER SUPPLY

HOW TO ORDER
100

In the order phase, it is mandatory to specify the interface type (RS485 or RS232) .
DAT3014 can be supplied with the configuration specified by the customer.
Please refer to the “Technical Specification” section for the output type available.

ORDER CODE:
DAT 3014 / 485 / Pt100

Interface type Input type


485 : RS-485
232 : RS-232 = Requested
17.5 = Optional
20 120
Datexel s.r.l. reserves its right to modify the characteristics of its products totally or in part without warning at any time. ED.05.06 REV.06