Perkins 4000 Series

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

4000 Series

4012-46TAG1A
Diesel Engine – ElectropaK
1263 kWm 1500 rpm
Economic power
 Individual four valve per cylinder heads give optimised gas flows, whilst digitally
governed unit fuel injectors ensure ultra-fine fuel atomisation and hence controlled
rapid combustion, for efficiency and economy
 Commonality of components with other engines in the 4000 Series family allows
reduced parts stocking levels

Reliable power
 Developed and tested using latest engineering techniques
 Piston temperature are controlled by an advanced gallery jet cooling system
 All engines are tolerant of a wide range of temperatures without derate
 Service is provided by the extensive Perkins network of over 4,000 distributors
and dealers worldwide
The Perkins 4000 Series family of 6, 8,
12 and 16 cylinder diesel engines was
designed in advance of today’s
Clean, efficient power
uncompromising demands within the  Exceptional power to weight ratio and compact size for easier transportation and
power generation industry and includes installation
superior performance and reliability.  New designed radiator assemblies with corrosion inhibiting powder coated finish;
The 4012-46TAG1A ElectropaK is a fewer pipe joints and easier access to reduce maintenance times
newly developed turbocharged, air-to-air  Designed to provide excellent service access for ease of maintenance
charge cooled, 12 cylinder diesel engine.  Engines designed to comply with major international standards
Offered with either Temperate or Tropical  Low gaseous emissions that will satisfy the requirements of 1/2 TA Luft (1986)
cooling packages (with or without fuel oil
cooling). Their premium design and
specification features provide economic
and durable operation as well as
exceptional power to weight ratio,
improved serviceability, low gaseous
emissions, overall performance and
reliability essential to the power
generation market.

Typical Generator Engine Power


Engine Speed Type of Output (Net) Gross Net
(rev/min) Operation
kVA kWe kWm bhp kWm bhp
1500 Baseload Power 1080 864 951 1276 909 1220
Prime Power 1364 1091 1191 1597 1149 1540
Standby (maximum) 1500 1200 1305 1750 1263 1694

The above ratings represent the engine performance capabilities guaranteed within plus or minus 3% at the reference conditions equivalent to those specified in ISO 8528/1, ISO 3046/1, BS 5514/1.
Rating conditions: 25°C air inlet temperature, barometric pressure 100 kPa, relative humidity 30%. Please consult your distributor or the factory for ratings in other ambient conditions.
Note: For full ratings please refer to Perkins Engines Company Limited. All electrical ratings are based on an average alternator efficiency and a power factor of 0.8.
Fuel specification: BS2869: Class A2.
Rating Definitions
Baseload Power: Power available for continuous full load operation. No overload is permitted.
Prime Power: Power available for variable load with an average load factor not exceeding 80% of the prime power rating in any 24 hour period. Overload of 10% permitted for 1 hour in every 12 hours operation
Standby (maximum): Power available at variable load in the event of a main power network failure up to a maximum of 500 hours per year. No overload is permitted.

All information in this document is substantially correct at time of printing and may be altered subsequently Publication No. 1825/11/06 Produced in England ©2006 Perkins Engines Company Limited
4000 Series Length Width

4012-46TAG1A

Height
Standard ElectropaK Specification
Air inlet
 Mounted air filters and turbochargers See ‘General Data - Dimensions’ below
Fuel System
 Direct fuel injection system with fuel lift pump Fuel Consumption
 Governing to ISO 8528-5 class G2 with isochronous capability 1500 rev/min
 Full-flow spin-on fuel oil filters Engine Speed
g/kWh l/hr
Lubrication System Standby 205 311
 Wet sump with filler and dipstick
Prime power 204 282
 Full-flow spin-on oil filters
 Engine jacket water/oil temperature stabiliser Continuous 202 223
baseload
Cooling System 75% of prime 203 211
 Two twin thermostats power
 System designed for ambients up to 50ºC 50% of prime 213 147
 Powder coated radiator comprising: water radiator; air charge cooled power
radiator; fuel oil cooling (optional); all pipes, hoses and clips; fan; pulleys;
fan belts and safety guards
General Data
Electrical Equipment Number of cylinders 12
 24 volt starter motor and 24 volt alternator with integral regulator and Cylinder arrangement 60º Vee form
DC output Bore and stroke 160 x 190 mm
 Overspeed switch and magnetic pickup Displacement 45.842 litres
 Turbine inlet temperature shutdown switch Induction system Turbocharged and
 Twin high coolant temperate shutdown switches air to air charge cooled
 Twin low oil pressure shutdown switches Cycle 4 stroke
Combustion system Direct injection
Flywheel and Housing Compression ratio 13.6:1
 Flywheel to SAE J620 size 18 Rotation Anti-clockwise, viewed
 SAE 00 flywheel housing from flywheel end
Cooling system Water-cooled
Firing order 1A, 6B, 5A, 2B, 3A, 4B,
Optional Equipment 6A, 1B, 2A, 5B, 4A, 3B
Choice of temperature or tropical radiators available dependant on Total lubrication 177.6 litres
operational cooling requirements system capacity
Fuel oil cooler integral to the radiator assembly Temperate Tropical
Immersion heater with thermostat Total coolant capacity 216 litres 198 litres
Note: This list is not exhaustive, for further options please contact your local Total weight 5517 kg 6026 kg
Perkins representative Dimensions Length 3951 mm 3971 mm
Width 1777 mm 2192 mm
Height 2231 mm 2260 mm

Final weight and dimensions will depend on completed specification

Perkins Engines Company Limited


Distributed by
Peterborough PE1 5NA
United Kingdom
Telephone +44 (0)1733 583000
Fax +44 (0)1733 582240
www.perkins.com

All information in this document is substantially correct at time of printing and may be altered subsequently
Publication No. 1825/11/06 Produced in England ©2006 Perkins Engines Company Limited