Fluke LinkRunner Pro Quick Reference
Fluke LinkRunner Pro Quick Reference
Fluke LinkRunner Pro Quick Reference
TM
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
PN 2688136 September 2006
© 2006 Fluke Networks. All rights reserved.
All product names are trademarks of their respective companies.
Cleaning
To prevent moisture from entering the LinkRunner Pro, clean it with a moist cloth only. Do not use organic solvents,
acid, or alkali solutions.
Safety Information
The following symbols are used on the product and in this document:
WWarnings
To avoid possible electric shock or personal injury, follow these guidelines:
• Do not use this product if it is damaged. Before using the product, inspect the case. Look for cracked or
missing plastic.
• Do not operate the product around explosive gas, vapor or dust.
• No serviceable parts. Do not try to service.
• If this product is used in a manner not specified by the manufacturer, the protection provided by the
product may be impaired.
WCautions
To avoid possible damage to the Network MultiMeter and to the equipment under test, follow these
guidelines.
• Use the proper terminals and cable for all connections.
External Features - Connections, Buttons, and the LED
1. RJ-45 LAN port 1
2. RJ-45 MAP port (cable testing) 2
3. Power Button
6
Power off – press and hold
Backlight – press once briefly
4. USB port
7
5. Selection buttons
- Up/Down arrows navigate the selections and adjust values 5
- Left/Right arrows show additional information and “select” to edit
- Select center button to edit a selection or toggle a value
6. Link indicator LED
7. Kensington lock (location on back of LinkRunner Pro) 4 3
Home screen – Displays link, speed/duplex, length, utilization, security authentication (802.1X, PoE,
Telco, Token Ring, un-terminated cable) and wire map information.
PING screen – Displays (scrolling from left to right) a Tx/Rx summary of all devices to the right which
will include: the Router, DHCP, DNS, and each user configured IP address.
LLDP (IEEE), EPD (Extreme Networks), CDP (CISCO) screen – Displays the switch type , slot, and port
number the LinkRunner Pro is connected to (up to 5 devices).
Flash Hub Port screen – Causes the LinkRunner Pro to continuously link and unlink at a selected speed.
This is useful when identifying which port LinkRunner Pro is connected to. Use LLDP/EDP/CDP test first
if your network supports it.
Toner screen – Generates a digital tone (IntelliTone) signal , or two different analog tone signals
(400 Hz) and (1 KHz) to be used with Fluke Networks IntelliTone product or common analog
probes.
Reports screen – Allows you to save up to 8 reports. Each report contains a summary of the Home
screen, PING screen, and LLDP, EDP, CDP screen. The reports must be viewed on the LinkRunner
Connect PC application.
Configuration screen – Multiple menu functions are accessed in this screen. The configuration screen
accesses: the LinkRunner Pro version information; cable length units (feet or meters); DHCP selection
(or manually enter the IP address and subnet mask); enter up to 10 PING addresses; enable options;
edit or delete reports; perform a firmware update; or exit back to the Home screen. See the
Configuration section for details.
Straight patch
Crossover patch 11
Unknown patch (Auto-MDIX 3
port on hub or switch) 4
2. Advertised speed/duplex
10
3. Actual link speed/duplex
4. Cable length from LinkRunner Pro to 6 7 9 8
cable end or device
5. Navigation arrows. Indicates which buttons are active.
6. Highlighted function is the active function. While a function is active, you my scroll to other functions.
Press the center button to select a new function.
7. Activity indicator.
8. Network Utilization. After 10% Utilization, scale changes to 100%.
9. PoE voltage
10. Scroll bar
11. Batteries low and batteries good
Good cable
Unknown cable
Split cable
Shorted cable
Open cable - If the RJ-45 Ethernet cable is not connected to the RJ-45
MAP port on the LinkRunner Pro, a WireviewTM Office Locator, or your
network, LinkRunner Pro will display cable information.
If the RJ-45 Ethernet cable is connected from the RJ-45 LAN port to the RJ-45
MAP port (or to a WireviewTM Office Locator), LinkRunner Pro will display wire
map information which includes length, open, shorts, and wire pair mapping.
Telco
Ping screen
The PING function contains several screens that are accessed by scrolling to the right. The first PING screen displays a
Tx/Rx summary of the Router, DHCP, and DNS PING results plus any IP addresses setup in the Configuration screen. As
you scroll to the right, the PING provides details on the Router, DHCP, DNS and up to 10 additional IP addresses are
displayed as shown below.
The 10 additional IP addresses are entered in the Configuration screen, or by using the LinkRunner Connect PC
application and downloading them via a provided USB cable to the LinkRunner Pro.
Note: If configured for DHCP, and the DHCP server cannot be found, Ping will display .
Saving Reports
Allows you to save the report summary information which contains the current Home
screen, PING screen, and LLDP, EDP, CDP screen. Saved reports must be viewed on a
PC using the LinkRunner Connect application. Make sure LinkRunner Pro is connected
to a PC using the provided USB cable.
To save a report: Highlight the Report symbol and press the selection button. Use the
left/right arrow keys to select which report number/name to save the summary
information to (default names are Report1 – Report8 which can be edited), and press
the selection button again.
report empty report saved
Configuration screen
The Configuration screen accesses multiple functions: It will display LinkRunner Pro version information, MAC
address, along with the serial number. It allows you to change the cable length measurements from feet to meters,
to use DHCP or manually enter the LinkRunner Pro IP address, enter up to 10 IP addresses to PING, and to enable
options.
To avoid a duplicate IP address on your network, use DHCP instead of manually entering the IP address.
Use the supplied LinkRunner Connect PC application to easily enter the PING IP addresses to LinkRunner Pros thru the
supplied USB cable.
Displays LinkRunner Pro’s serial number, MAC number, and software version
numbers.
Cable test unit selection screen
Select the cable length units as either feet or meters. Use the right arrow key to
toggle units and the center button to save.
LinkRunner IP address
Allows user to configure DHCP or use manual IP, Mask, and Router addresses. To
manually enter the IP address, uncheck DHCP using the left/right arrow keys to check
and uncheck the check box. Then, using the down arrow key, move down to the IP
address. Press the selection button (center). Move right to each digit (by using the
right arrow key) and use the up/down arrow keys to select each digit value. Keep
doing this until the IP address is entered. Press the center button to save the
information. Use the same procedure as above to edit the Mask and Router
information.
Reports Edit/Erase
Allows you to edit/erase up to 8 reports. Each report contains a summary of the Home
screen, PING screen, and LLDP, EDP, CDP screen. The reports must be viewed on the
LinkRunner Connect PC application.
Selecting the report name/number to edit: When is highlighted, press the
selection button (center). Use the up/down arrow keys to choose the report number
and the selection button to select it. Notice at the bottom of the display, the report
name changes as you scroll thru the 8 report numbers. By default the names are
Report1 – Report8.
Editing the report name: Using the down arrow key, move down to the report name.
Press the selection button (center). To edit the report name, move right to each
character (by using the right arrow key) and use the up/down arrow keys to select
each character value. Keep doing this until the report name is entered, then press the
selection button.
Erasing a report: Using the down arrow key, move down to erase the report. Press the
selection button (center) and the report is erased. Erased or empty reports have no
lines in the symbol.
Other Features
Auto-off: unit powers off after 5 minutes of inactivity (auto-off disabled during ping or cable locate tasks).
Restore Factory Defaults: Press the left and right arrow keys while powering up the unit.
Accessories
Accessories Part No.
IntelliTone Pro Toner Probe (receiver) MT-8200-63A
WireviewTM Office Locator (ID #1) WIREVIEW 1
WireviewTM Office Locator (IDs # 2-6) WIREVIEW 2-6
Clip Set CLIP-SET
RJ-45 Coupler CIQ-RJA
Media Access 10BASE-T, 100BASE-TX, 1000BASE-T (IEEE 802.3), and PoE (IEEE 802.3af)
Cable Tests Pair lengths, opens, shorts, splits, crossed, straight through, WireView cable ID
Tone Generator IntelliTone digital tone: [500 KHz]
Analog tones: [400Hz, 1KHz]
UI Interface B&W, 2”x 1” display, Link LED
UI Control / Data Entry Five push-buttons for selection of icons and navigation of menus
Power Button On/Off
Ports (2) RJ45s: network test port, loop-back wire map port
Application Port Mini-USB
Back to the LinkRunner Product Info Page
Battery 4 AA batteries
Physical Security Kensington Lock
Warranty One year Visit us at www.TestEquipmentDepot.com
Mechanical Electrical Specifications
Weight 10 oz. with 4 AA Alkaline batteries
8.4 oz. with 4 AA LI batteries
Dimensions 5.3” height x 3.1” width x 1.3” depth
13.3cm height x 8cm width x 3.2cm depth
RJ-45 Network Port Designed to withstand a maximum of 100V
Security
Operational Security IEEE 802.1X option for network authentication
Environment Specifications
Operating Temperature 10 – 40 degrees C
Storage Temperature -20 to 60 degrees C
Operating Humidity 95% relative humidity (non-condensing)
Vibration Requirements Meets requirements for MIL-PRF-28800F for Class 2 random vibration
Connection To Public Telephone Network Should never be connected to the public telephone network