Kn-Rc-Airco3: 1. Panel Description MANUAL (P. 3) 5. Fast Cool/fast Heat Function

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

KN-RC-AIRCO3 ENGLISH ENGLISH ENGLISH

1. 1. Panel description 5. Fast cool/Fast heat function


MANUAL (p. 3) BRUGERVEJLEDNING (s. 29) 1. Run mode display 11. Enter key Press the fast cool key to automatically set the air conditioner to 21 °C, middle wind,
2. Signal sending display 12. Clock function key automatic blowing direction. Or, press the fast heat key to automatically set the air
ANLEITUNG (S. 5) VEILEDNING (s. 31)
3. Blowing direction display 13. Set key conditioner to 27 °C, middle wind and automatic blowing direction.
MODE D’EMPLOI (p. 7) ʗʜʠʡʟʢʙʥʗʮȋ͛͛˔˕˓ǤȌ 4. Model code 14. Timing on key
20 1 5. Temperature “–” key 15. Fast heat key
6. Notes
GEBRUIKSAANWIJZING (p. 9) KILAVUZ (s. 35) 2 6. Mode key 16. Fan key
Make sure the air conditioner is in working order. Be aware that the remote control cannot
increase the function of the air conditioner. If the remote control will not be used for a long
MANUALE (p. 11) KASUTUSJUHEND (lk. 37)
19 3 7. Automatic blowing direction control key 17. Blowing direction control key
time, make sure to remove the batteries to prevent damage to the remote control.
8. Power key 18. Temperature “+” key
MANUAL DE USO (p. 13) NÁVOD (s. 39) 9. Fast cool key 19. Fan display
MANUAL (p. 15) 
#ȋŽ’’Ǥ͙͜Ȍ
4 10. Timing off key 20. Temperature display

HASZNÁLATI ÚTMUTATÓ (o. 17)  ȋ͛͜’ǤȌ 2. Installing the batteries


18 5 Remove the battery cover of the remote control and install two AA size batteries. Install the
KÄYTTÖOHJE (s. 19)  , ȋ•–”Ǥ͜͝Ȍ
battery cover. The time will appear in the left corner of the LCD display.
BRUKSANVISNING (s. 21) ʟʩʙʝʑʝʓʠʡʑʝȋ’Ǥ͜͟Ȍ
6 3. Set up instructions
~ Aȋ•Ǥ͚͛Ȍ  O
ȋ•–”Ǥ͜͡Ȍ Method A: digital automatic search set up.
17 7 a) Turn on air conditioner and aim the remote control directly at it.
MANUAL DE UTILIZARE (p. 25)  , ȋ•–”Ǥ͙͝Ȍ
16 8 b) Hold the set key until the code changes in the mode window. Then
ȠȞȱȠȤȬȤȟȤȪ ȭ ȭȋɐɂɉǤ͚͟Ȍ release it. The system will switch to automatic search and the code
15 will increase with 1 unit every two seconds. Pay attention to the air Safety precautions:
9 conditioner. Keep searching until the air conditioner automatically turns
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
To reduce risk of electric shock, this product should ONLY be opened by an authorized
technician when service is required. Disconnect the product from mains and other
14 10 on/off. Press the enter key to finish set up. equipment if a problem should occur.

13 11 Method B: direct code setup. Warranty:

12
No guarantee or liability can be accepted for any changes and modifications of the product or damage caused due to
a) Refer to the CODE FORM and find the number corresponding with your brand. Power on incorrect use of this product.
the air conditioner manually. For example: INYCIN is code 188-190. General:
b) Hold the set key ( for about 3 seconds) until the code flashes in the display. Press Designs and specifications are subject to change without notice.
temperature “+” or “–” until the code you want to choose appears.
This product has been manufactured and supplied in compliance with all relevant regulations and directives, valid for all
c) Press enter key and the code stops flashing. member states of the European Union. It also complies to all applicable specifications and regulations in the country of
d) Check whether the keys on the remote control work normally. If not, repeat steps b-d until sales.
a suitable code is found. Formal documentation is available upon request. This includes, but is not limited to: Declaration of Conformity (and
product identity), Material Safety Data Sheet, product test report.

4. Timing on/off function Please contact our customer service desk for support:
Press timing on key to increase the starting time for the air conditioner by 1 hour. The via website: http://www.nedis.com/en-us/contact/contact-form.htm
displayed time is the time when the air conditioner will automatically be switched on. Pressing via e-mail: [email protected]
timing off key will delay the time the air conditioner will be turned off by 1 hour each time the via telephone: +31 (0)73-5993965 (during office hours)
key is pressed. The timing function uses a 15-hour indication to show and set up the time. NEDIS B.V., De Tweeling 28, 5215 MC ’s-Hertogenbosch, THE NETHERLANDS

2 3 4

BRAND CODE BRAND CODE BRAND CODE BRAND CODE


Applicable brand and code list
FEILU 240-249 KT02_D001 283 SHARP 720-739 YAOMA 470
BRAND CODE BRAND CODE FEIGE 829-830 KT02_D002 284 SHAMEI 400 YIDONG 499
AKIRA 796-797 GALANZ 140-149 FRESTECH 270-279 KTY001 285 SHANXING 401-402 YORK 775-779
AUX 180-199 GREE 000,020-039 FUJITSU 700-719 KTY002 286 SHANGLING 403-409 YUTU 484-490
AUCMA 210-229 GEER 342-343 GOLDSTAR 303 KTY003 287 SHENBAO 410-411 ZHONGYI 493-494
AIDELONG 293-295 GLEE 280 BRAND CODE BRAND CODE SHENGFENG 412 ZUODAN 495
AITE 296-299 GUQIAO 344 KTY004 288 SHUANGLU 416-418 SHENGFENG\FEILU 413 OTHER 496, 498
KTY005 289 SIGMA 447 SHINING 415 806-809
AOLI 300 GUANGDA 345-346
LIANGYU 780 SOGO 291 SHINCO 200-209 839-999
AOKE 301-302 HAIER 001-019
BAIXUE 299 HICON 391-392 LG 600-609 SOVA 292
LITTLESWAN 453 SONGXING 419 z This company reserves the right to interpretation of the User’s Manual. Design and
BEIJINGJINGDIAN 304 HITACHI 640-659 technical parameters may vary without notice.
BOERKA 305-306 HISENSE 230-239 LIKEAIR 386-387 SOVA 420
BORLER 307 HONGYI 347 LOREN-SEBO 801-803 SOYEA 421-422
BOSHIGAO 308-309 HUABAO 100-109 MCQUAY 790-795 SRTC 423
BOSHI 310 HUALING 150-169 MD 040-059 SUNBURG 817-820
BIG-THUMB 331 HUAGAO 348 MEILING 389-390 TCL 120-139
CAIXING 311 HUAWEI 281 MINGXING,BOYIN 290 TECO 831-834
CARRIER 690-699 HUAKE 349-350 MITSUBISHI 551-599 TIANYUAN 425-428
CHANGLING 312-323 HUAMEI 351-352 NATIONAL 660-690 TIANJINKONGTIAO 424
CHANGHONG 060-079 HUANGHE 353 NISO 497 TOBO 250-269
CHANGFENG 190 HUIFENG 354-356 NISO 398-399 TONGLI 429-430
CHENGYUAN 324 HUIFENG 357 NIKKO 810-811 TOSHIBA 630-639
CHUANGHUA 325-328 HYUNDAI 780-789 PANSONIC 660-689 TOYO 825-828
CHUNLAN 170-179 INYCIN 475-483 PANDA 464-466 TRANE 812-816
CHIGO 080-099 JIALE 358 P1NS HANG, X IN H 290 UNI-AIR 368-369
UABAO
CONROWA 337-341 JIANGNAN 359
QIXING 393 UTTLEDUCK 454-456
CORONA 760-769 JMSTAR 360
RAY BO 371-383 WANBAO 431-433
CHANGFU 835-838 JINBEIJING 361-362
ROWA 383-385 WEILI 434-443
DAEWOO 332-333 JINDA 491-492
RICAI 394 WEITELI 444
DAIKIN 740-759 JINSONG 363-365
RIJIANG 395-397 WHIRLPOOL 770-774
DAJINXING 329,330 JOHNSO 282
SACON 414 WUFENG 445-446
DAOTIAN 821-824 KANGLI 368-370
SANZUAN 190 XILENG 448-449
DONGXINBAO 260-268 KELONG 110-119
SANYO NEC 500-550 XINLE 457-460
DONGXIA 334-335 KLIMATAIR 797-800
SAMSUNG 610-629 XINLING 461
DUNAN 336 KONKA 366-367
SAST 450-452 XINGHE 462-463
ELECTROLUX 471-474 KRIS 804-805
SERENE 499 YAIR 467-471

5 6 7 8