The Design Is Adequate.: W F F X X X y X
The Design Is Adequate.: W F F X X X y X
The Design Is Adequate.: W F F X X X y X
CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Seismic Design for Intermediate/Ordinary Moment Resisting Frames Based on CBC 07, AISC 341-05 & AISC 358-05
ANALYSIS
THE SEISMIC DESIGN FACTOR COMPARISON (ASCE 7-05, Table 12.2-1)
FRAME TYPE R Wo Cd
SMRF 8 3 5 1/2
IMRF 4.5 3 4
OMRF 3.5 3 3
Technical References:
1. AISC 341-05: "Seismic Provisions for Structural Steel Buildings", American Institute of Steel Construction, Nov. 16, 2005.
2. AISC 360-05: "Specification for Structural Steel Buildings", American Institute of Steel Construction, March 9, 2005.
3. AISC 358-05: "Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications",
American Institute of Steel Construction, Dec 13, 2005.
4. Thomas A. Sabol, Ph.D., S. E.: "2005 AISC Seismic Provisions and Seismic Design Manual Seminar", AISC, Oct. 12, 2006.