Description Type No. Frequency range Max. input power Connector Page
Hybrid Combiner 2:1 78210500 791 – 960 MHz 60 W at each port 7-16 415
Hybrid Combiner 2:1 78210502 1710 – 2170 MHz 60 W at each port 7-16 416
Hybrid Combiner 2:1 78210504 698 – 2690 MHz 60 W at each port 7-16 417
Hybrid Combiner 2:1 78210506 698 – 2690 MHz 150 W at each port 7-16 418
Hybrid Combiner 8:4 78211141 698 – 960 MHz 75 W 7-16 419, 420
1710 – 2690 MHz at each port
Hybrid Combiner 8:4 78211142 1710 – 1880 MHz 75 W 7-16 419, 420
1920 – 2170 MHz at each port
Hybrid Combiner 12:4 78211143 698 – 960 MHz 50 W 7-16 419, 420
1710 – 1880 MHz at each port
1920 – 2170 MHz
Hybrid Combiner 16:4 78211144 698 – 960 MHz 50 W 7-16 419, 420
1710 – 1880 MHz at each port
1920 – 2170 MHz
2500 – 2690 MHz
Hybrid Combiner 3:3 78211216 548 – 2690 MHz 150 W at each port 4.3-10 421
Hybrid Combiner 4:4 78210534 698 – 2600 MHz 150 W at each port 7-16 422
Same-Band Combiner 78211237 791 – 862 MHz 100 W at each port 7-16 423
Duplex Hybrid Combiner 78210805 Rx: 880 – 915 MHz 250 W 7-16 424, 425
Tx: 925 – 960 MHz
Active Duplex Hybrid 78211110 Rx: 880 – 915 MHz 250 W 7-16 426, 427
Combiner Tx: 925 – 960 MHz
Same-Band Combiner 78210936 880 – 960 MHz 100 W at each port 7-16 428, 429
Same-Band Combiner 78211230 1710 – 1880 MHz 100 W at each port 7-16 430, 431
Same-Band Combiner 78211235 1730 – 1880 MHz 100 W at each port 7-16 432, 433
Same-Band Combiner 78211370 1710 – 1880 MHz 100 W at each port 7-16 434, 435
Same-Band Combiner 78210925 1920 – 2170 MHz 100 W at each port 7-16 436, 437
Same-Band Combiner 78210926 1920 – 2170 MHz 100 W at each port 7-16 438, 439
Same-Band Combiner 78211228V01 2500 – 2640 MHz 100 W at each port 4.3-10 440, 441
Same-Band Combiner 78211228V03 2500 – 2960 MHz 100 W at each port 4.3-10 442, 443
3-dB Coupler 78210524 698 – 2690 MHz 150 W at each port 7-16 444, 445
3-dB Coupler 78210525 698 – 2690 MHz 1000 W at each port 7-16 446, 447
3-dB Coupler 793554 800 – 2200 MHz 300 W 7-16 448
New
Products
412
Summary of Same-Band Combiner and
Hybrid Combiner Types
Frequency Combinations
413
414
Hybrid Combiner 2:1
791 − 960 MHz
2 x 60 W
• Designed for the decoupled combining of 2 transmitter
or receiver signals onto one common antenna
Port 3
• The frequency spacing between transmitter signals can
be as small as required
• Excellent intermodulation performance
• Suitable for indoor or outdoor applications
Port 1
• Wall or mast mounting
• DC by-pass between all ports Port 2
• External DC stop available as an accessory
Technical Data
Note:
The input power rating of 60 W per port is specified at an ambient temperature of
+55 °C with the combiner mounted vertically, without additional cooling, and while
respecting the safety standard EN IEC 60950 (max. surface temperature +90 °C).
If mounted vertically and/or used at a lower ambient temperature, then a higher input
power in accordance with the following table is possible:
Max. ambient
temperature
+55 °C 60 W 70 W
+40 °C 70 W 80 W
+25 °C 75 W 85 W
415
Hybrid Combiner 2:1
1710 − 2170 MHz
2 x 60 W
Technical Data
Type No. 78210502
Frequency range 1710 – 2170 MHz
Attenuation
Port 1 Port 3 3.1 ±0.5 dB
Port 2 Port 3 3.1 ±0.5 dB
Port 1 Port 2 > 22 dB *
VSWR (all ports) < 1.25
Impedance 50 Ω
Input power
Port 1 < 60 W
Port 2 < 60 W
Intermodulation products < –160 dBc (3 rd order; with 2 x 20 W)
Temperature range –40 … +55 °C
Connectors 7-16 female (long neck)
Application Indoor or outdoor (IP 66)
DC/AISG transparency Bypass between all ports (max. 2500 mA)
AISG: Attenuation 3 dB with / 6 dB without
external DC stop at either Port 1 or Port 2
Mounting Wall mounting: With 4 screws (max. 6.5 mm diameter)
Mast mounting: With additional clamp set
Weight 3.7 kg
Packing size 377 x 232 x 189 mm
Dimensions (w x h x d) 143.6 x 256 x 97.5 mm (including connectors)
Note:
The input power rating of 60 W per port is specified at an ambient temperatu-
re of +55 °C with the combiner mounted horizontally, without additional cooling,
and while respecting the safety standard EN IEC 60950 (max. surface tempe-
rature +90 °C).
If mounted vertically and/or used at a lower ambient temperature, then a higher
input power in accordance with the following table is possible:
Max. ambient
temperature
+55 °C 60 W 70 W
+40 °C 70 W 80 W
+25 °C 75 W 85 W
416
Hybrid Combiner 2:1
698 − 2690 MHz
2 x 60 W
Port 2
Technical Data
Type No. 78210504
Max. ambient
temperature
+55 °C 55 W 60 W
+40 °C 70 W 75 W
+25 °C 80 W 85 W
417
Hybrid Combiner 2 : 1
698 – 2690 MHz
2 x 150 W
Port 2
Port 3
Port 1
Technical Data
Note:
Mounted horizontally Mounted vertically
The input power rating of 150 W is specified at an ambient tempera-
ture of +40 °C with the combiner mounted vertically, without additional
cooling, and while respecting the safety standard EN IEC 60950 (max.
surface temperature +90 °C).
The max. power rating increases or decreases with falling or rising Max. ambient
ambient temperature and depending on horizontal or vertical mounting temperature
in accordance with the following table:
+55 °C 80 W 100 W
+40 °C 110 W 150 W
- Clamp set (type no. 734360 - 734365),
- DC stop (type no. 78210850V01) +25 °C 150 W 100 W
(order separately) can be found in the section “System
Components”.
418
Hybrid Combiner System
8 : 4 / 8 : 4 / 12 : 4 / 16 : 4
78211141 78211142
Note:
The use of fewer than 8/12/16 inputs or 4 outputs is possible. Any unused input ports have to be terminated with low-
power 50-Ohm loads (e.g. Kathrein type 78410367), unused output ports have to be terminated with high-power
50-Ohm loads (e.g. Kathrein low intermodulation type 78210474).
419
Hybrid Combiner
8 : 4 / 8 : 4 / 12 : 4 / 16 : 4
78211141, -2, -3, -4
78211141
78211142
78211143
78211144
420
Hybrid Combiner 3 : 3
548 – 2690 MHz
Preliminary Issue
Technical Data
Note:
The use of fewer than 3 inputs or outputs is possible.
Any unused input ports have to be terminated with lowpower
50-Ohm loads, unsused output ports have to be terminated
with highpower 50-Ohm loads.
421
Hybrid Combiner 4:4
698 – 2690 MHz
4 x 150 W
• Designed for the decoupled combining of 4 transmitter Output 1
or receiver signals and distributing these signals equally
Output 2
onto 4 antenna outputs
• Suitable for indoor or outdoor applications Output 3
Input 1
Input 2
Note:
The use of fewer than 4 inputs or outputs is possible. Any unused
input ports have to be terminated with low-power 50-Ohm loads
(e.g. Kathrein type 784 10367), unused output ports have to be
terminated with high-power 50-Ohm loads (e.g. Kathrein low-
intermodulation type 78210474).
422
Same-Band Combiner
791 – 801 / 832 – 842 MHz 811 – 821 / 852 – 862 MHz
Block Diagram
423
Duplex Hybrid Combiner (Same-Band Combiner)
• DC/AISG bypass for DTMA supply (for UMTS paths only) Port 4
• Rx diversity ports protected against incorrectly connected
Tx power Port 5
Technical Data
Type No. 78210805
Pass band
Rx MHz 880 – 915
Tx MHz 925 – 960
Insertion loss
Port 1 ↔ Port 3 / Port 4 ↔ Port 6 dB < 0.4, typically 0.2 (925 – 960 MHz) –
see Diagram I and II
dB < 4.3, typically 3.6 (880 – 915 MHz) –
see Diagram I and II
Port 2 ↔ Port 3 / Port 5 ↔ Port 6 dB < 4.0, typically 3.5 (880 – 915 MHz) –
see Diagram III and IV
Isolation
Port 1 ↔ Port 2 / Port 4 ↔ Port 5 dB > 25 (880 - 915 MHz)
dB > 35 (925 - 960 MHz)
VSWR < 1.2 (880 - 915 / 925 - 960 MHz)
Impedance Ω 50
Input power W Port 1: < 250 Port 2: < 50
W Port 4: < 250 Port 5: < 50
Intermodulation products dBc < –160 (3rd order; with 2 x 20 W)
Temperature range °C –40 ... +65
Connectors 7-16 female (long neck)
Application Indoor or outdoor (IP 66)
DC/AISG transparency
Port 1 ↔ Port 3 / Port 5 ↔ Port 6 Stop
Port 2 ↔ Port 3 / Port 4 ↔ Port 6 By-pass (max. 2500 mA)
Lightning protection 3 kA, 10/350 µs pulse
Mounting With 4 screws (max. 8 mm diameter)
Mast mounting: With additional clamp set
Weight kg | lb 6.5 | 14.3
Packing size mm | in 390 x 470 x 160 | 15.4 x 18.5 x 6.3
Dimensions (w x h x d) mm | in 287.1 x 278.6 x 71 | 11.3 x 7.0 x 2.8
(without connectors, without mounting brackets)
424
Duplex Hybrid Combiner (Same-Band Combiner)
Attenuation/dB
734362 80 – 100 | 3.15 – 3.94 5
25
30
45
78410367 50-Ohm load
1.5 W / indoor or outdoor 50
870 880 890 900 910 920 930 940 950 960 970
Frequency/MHz
0.5
1.0
880 - 915 925 - 960
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
870 880 890 900 910 920 930 940 950 960 970
Frequency/MHz
10
880 - 915 925 - 960
15
20
25
30
35
40
45
50
870 880 890 900 910 920 930 940 950 960 970
Frequency/MHz
0.5
1.0
880 - 915 925 - 960
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
Application example
870 880 890 900 910 920 930 940 950 960 970
Frequency/MHz
425
Active Duplex Hybrid Combiner (tunable)
Active Duplex Hybrid
(Same-Band Combiner (Same-Band Combiner)
Combiner)
880– ...
880 915960
/ 925MHz
– 960 MHz 880
880...– 960
915 / MHz
925 – 960 MHz
EGSM 900 UMTS 900
• Enables antenna and feeder sharing for two base stations
• Enables
in the 900antenna and feederband
MHz frequency
the 900 MHz frequency band
sharing for two base stations in RET = Remote Electrical Tilt
AISG = Antenna Interface Standards Group
•• 12Very
• 12 dB gain over 20 MHz Rx bandwidth (factory tunable) CWA = Current Window Alarm
dB gain over 20 MHz Rx bandwidth (factory tunable)
• tunable)
Very
low insertion loss over 20 MHz Tx bandwidth (factory
low insertion
tunable) compared
compared
loss over 20 MHz
totostandard
standard Tx combiners
hybrid
hybrid
bandwidth (factory
combiners
•• Double
Doubleunit unitininone
onehousing
housingfor
forXPol
XPolantennas
antennas
•• Suitable
Suitablefor forindoor
indoorororoutdoor
outdoorapplications
applications
Port 3
•• Supports
SupportsAISG AISG1.1 1.1and
andAISG
AISG2.0
2.0(default)
(default)
Port 6
• standard
Suitableforforantenna
• Suitable
standard
antennaRET RETcontrol
controlaccording
according to to AISG/3GPP
AISG/3GPP
•• Bypass
Bypassmode
power
powerdown
mode
down
(LNA)
(LNA) to to ensure
ensure cellcell operation
operation in case
in case of DC
of DC
•• Built-in
Built-inlightning
lightning protection
protection
Frequency
Frequency ordering information:
ordering information:
When
Whenordering please
ordering specify
please the required
specify Tx-and Rx-frequencies
the required Tx- and
Port 1
Examples of tuning versions:
Rx-frequencies
78211110V01:
Examples ofRx 880 – versions:
tuning 900 MHz, Tx 925 – 945 MHz RET
78211110V02:
78211110V01Rx 895880
: Rx – 915 MHz,MHz,
– 900 Tx 940Tx– 925
960 MHz
– 945 MHz Port 2
Other frequencies on request.
78211110V02: Rx 895 – 915 MHz, Tx 940 – 960 MHz Port 4 Port 5
Other frequencies on request.
Technical Data
Type No. 78211110
Technical
Pass band Data
Rx 20 MHz within 880 ... 915 MHz (factory tunable)
Type
Tx No. 78211110
20 MHz within 925 ... 960 MHz (factory tunable)
Tx
PassInsertion
band loss
Port
Rx2 � Port 3 / Port 5 � Port 6 < 0.2MHz
dB (925 – 94520MHz)* within–880see...Diagram I andtunable)
915 (factory II
Tx
Isolation MHz 20 within 925 ... 960 (factory tunable)
TxPort 1 � Portloss
Insertion 2 / Port 4 � Port 5 > 25 dB (880 – 900 MHz)*
Port 2 ↔ Port 3 / Port 5 ↔ Port 6 dB > 65 dB (925
< 0.2 (925 –– 945
945 MHz)
MHz)** – see Diagram I and II
Gain
Isolation 12 dB nominal
Port 1 ↔ Port 2 / Port 4 ↔ Port 5 dB > 25 (880 – 900 MHz)
Gain ripple dB ±1 dB > 65 (925 – 945 MHz)
Loss
Gain in bypass mode dB < 5.5 dB (DC OFF) 12 nominal
Return loss
Gain ripple > 18 dB (DC ON) / > 12 dB (DC
dB ±1OFF)
Noise
Loss infigure
bypass mode dB < 1.6 dB (+22 ... +28 < 5.5°C) (DC OFF)
Return1-dB
Output losscompression point dB > 18
> 11 dBm (DC ON) / > 12 (DC OFF)
3Return
rd orderloss
intercept point (OIP3) dB
> 25 dBm (typically 30 < 1.6
dBm) (+22 ... +28 °C)
Output 1-dB compression point
VSWR dBm
< 1.25 (880 – 900 / 925 – 945> 11
MHz)*
3rd order intercept point (OIP3) dBm > 25 (typically 30 dBm)
Impedance 50 Ω
VSWR < 1.25 (880 – 900 / 925 – 945 MHz) *
Input power Port 2 < 200 W
Impedance Ω Port 5 < 200 W 50
Input power
Intermodulation products W< 160 dBc (5th order, with Port2 x220< 200
W)
Port 5 < 200
Environmental Characteristics
Intermodulation products dBc < –160 (5 order; with 2 x 20 W)
th
Operating
Environmental temperature range
Characteristics –40 … +65 °C
IP rating temperature range
Operating °C IP67 (see note on page –40 2)... +65
IP rating
MTBF > 1 000 000 hours IP 67(per
(seeTMA)note on page 2)
MTBF
EMC According to>ETS 1 000300 000 hours (per TMA)
342-3
EMC According to ETS 300 342-3
DC and Alarm Characteristics CWA Mode AISG Mode
DC and Alarm Characteristics CWA Mode AISG Mode
DC supply 9 – 19 V 9 – 30 V
DC supply V 9 – 19 9 – 30
Operating
Operating current
current per
per TMA
TMA 80
mA– 120 mA 80 – 120 Nom. 20 mA Nom. at 9 V80 at 9 V
(without
(without RET)RET) Nom. 30 mA Nom. at 30 V30 at 30 V
Alarm management
Alarm management 170
mA– 200 mA170 – 200 AISG (see AISG note on page
(see 2) on page 2)
note
Mechanical
MechanicalCharacteristics
Characteristics
Connectors
Connectors RF RF 7-16 female (long neck) (long neck)
7-16 female
AISG AISG 8-pin female,8-pin IEC 60130-9
female, IEC 60130-9
(Pin 3: RS485B,(Pinpin 5: RS485A,
3: RS485B, pinpin5: 6: 9 – 30 V
RS485A, DC,
pin 6: 9 – 30 V DC,
pin 7: DC return,
pin 7:other pins: not
DC return, connected)
other pins: not connected)
Mounting
Mounting Wall mounting: Wall
with mounting:
4 screws (max.with 48screws (max. 8 diameter)
mm diameter)
Mast mounting: Mast mounting:
with additional with additional
clamp set clamp set
Weight kg | lb 6.8 | 15.0
Weight 6.8 kg
Packing size 460 x 375 x 135 | 18.1 x 14.8 x 5.3
Packing
Dimensions size(w x h x d) mm | in 460 x 375369xx135 209mm x 68 | 14.5 x 8.2 x 2.7
Dimensions (w x h x d) 369 x 209
(without x 68 mm without mounting brackets)
connectors,
* Tuning version 78211110V01: Rx (without
880 – 900 connectors,
MHz, Tx 925 without
– 945mounting
MHz brackets)
* Tuning version 78211110V01: Rx 880 – 900 MHz, Tx 925 – 945 MHz
426
288
Active Duplex Hybrid Combiner (Same-Band Combiner)
Active Duplex Hybrid Combiner (tunable)
880 ... 960 MHz 880 ... 960 MHz
(Same-Band
EGSM 900 Combiner)
UMTS 900
880 – 915 / 925 – 960 MHz 880 – 915 / 925 – 960 MHz
• Enables antenna and feeder sharing for two base stations in
the 900 MHz frequency band
RET = Remote Electrical Tilt
AISG = Antenna Interface Standards Group
• 12 dB gain over 20 MHz Rx bandwidth (factory tunable) CWA = Current Window Alarm
•Accessories
Very low insertion
(order loss over 20 MHz Tx bandwidth (factory
separately)
tunable) compared to standard hybrid combiners Clamp Set
Tx Insertion loss
Port 2 � Port 3 / Port 5 � Port 6 < 0.2 dB (925 – 945 MHz)* – see Diagram I and II
Isolation
Port 1 � Port 2 / Port 4 � Port 5 > 25 dB (880 – 900 MHz)*
> 65 dB (925 – 945 MHz)*
Gain 12 dB nominal
Gain ripple ±1 dB
Loss in bypass mode < 5.5 dB (DC OFF)
Return loss > 18 dB (DC ON) / > 12 dB (DC OFF)
Noise figure < 1.6 dB (+22 ... +28 °C)
Output 1-dB compression point > 11 dBm
3rd order intercept point (OIP3) > 25 dBm (typically 30 dBm)
VSWR < 1.25 (880 – 900 / 925 – 945 MHz)* Diagram III Port 1 ↔ Port 3
Port 4 ↔ Port 6
Impedance 50 Ω
Input power Port 2 < 200 W
Port 5 < 200 W
Intermodulation products < 160 dBc (5th order, with 2 x 20 W)
Environmental Characteristics
Operating temperature range –40 … +65 °C
IP rating IP67 (see note on page 2)
MTBF > 1 000 000 hours (per TMA)
EMC According to ETS 300 342-3
DC and Alarm Characteristics CWA Mode AISG Mode
DC supply 9 – 19 V 9 – 30 V
Operating current per TMA 80 – 120 mA Nom. 20 mA at 9 V
(without RET) Nom. 30 mA at 30 V
Alarm management 170 – 200 mA AISG (see note on page 2) Diagram IV Port 1 ↔ Port 3
Port 4 ↔ Port 6
Mechanical Characteristics
Connectors RF 7-16 female (long neck)
AISG 8-pin female, IEC 60130-9
(Pin 3: RS485B, pin 5: RS485A, pin 6: 9 – 30 V DC,
pin 7: DC return, other pins: not connected)
Mounting Wall mounting: with 4 screws (max. 8 mm diameter)
Mast mounting: with additional clamp set
Weight 6.8 kg
Packing size 460 x 375 x 135 mm
Dimensions (w x h x d) 369 x 209 x 68 mm
(without connectors, without mounting brackets)
* Tuning version 78211110V01: Rx 880 – 900 MHz, Tx 925 – 945 MHz
288
427
Same-Band Combiner
880 − 890 / 925 − 935 MHz 902.5 − 915 / 947.5 − 960 MHz
Tuning Diagram
Technical Data
Type No. 78210936
Pass band
BTS 1 (GSM900 / Operator 1) Rx1/Rx2 = 880 - 890 MHz, Tx1/Tx2 = 925 - 935 MHz
BTS 2 (GSM900 / Operator 2) Rx3/Rx4 = 902.5 - 915 MHz, Tx3/Tx4 = 947.5 - 960 MHz
Insertion loss
Port 1 ↔ Port 3 / Port 4 ↔ Port 6 < 0.5 dB, typically 0.3 dB (880 - 890 MHz) / < 0.7 dB, typically 0.4 dB (925 - 935 MHz)
Port 2 ↔ Port 3 / Port 5 ↔ Port 6 < 0.7 dB, typically 0.5 dB (902.5 - 915 MHz) / < 0.5 dB, typically 0.3 dB (947.5 - 960 MHz)
Isolation
Port 1 ↔ Port 2 / Port 4 ↔ Port 5 > 30 dB (880 - 890 / 902.5 - 915 / 925 - 935 / 947.5 - 960 MHz)
VSWR < 1.2 (pass bands)
Impedance 50 Ω
Input power
Tx1 / Tx2 / Tx3 / Tx4 < 100 W / < 100 W / < 100 W / < 100 W
Intermodulation products < -160 dBc (3rd order; with 2 x 20 W)
Temperature range -40 ... +60 °C
Connectors 7-16 female (long neck)
Application Indoor or outdoor (IP 66)
DC/AISG transparency
Port 1 ↔ Port 3 / Port 4 ↔ Port 6 Stop
Port 2 ↔ Port 3 / Port 5 ↔ Port 6 Bypass (max. 2500 mA)
Lightning protection 3 kA, 10/350 µs pulse
Mounting Wall mounting: With 4 screws (max. 8 mm diameter)
Mast mounting: With additional clamp set
Weight 6.9 kg
Dimensions (w x h x d) 275 x 176 x 140 mm (without connectors, without mounting brackets)
428
Same-Band Combiner
880 − 890 / 925 − 935 MHz 902.5 − 915 / 947.5 − 960 MHz
Attenuation/dB
-5 -0.5
880 - 890 925 - 935
Rx1/Rx2 Tx1/Tx2
-10 -1.0
880 - 890 925 - 935
Rx1/Rx2 Tx1/Tx2
-15 -1.5
-20 -2.0
-25 -2.5
-30 -3.0
-35 -3.5
-40 -4.0
-45 -4.5
-50 -5.0
-5 -0.5
-10 -1.0
902.5 - 915 947.5 - 960 902.5 - 915 947.5 - 960
Rx3/Rx4 Tx3/Tx4 Rx3/Rx4 Tx3/Tx4
-15 -1.5
-20 -2.0
-25 -2.5
-30 -3.0
-35 -3.5
-40 -4.0
-45 -4.5
-50 -5.0
870 880 890 900 910 920 930 940 950 960 970 870 880 890 900 910 920 930 940 950 960 970
Frequency/MHz Frequency/MHz
Block Diagram
429
Same-Band Combiner
1710 – 1740 / 1805 – 1835 MHz 1755 – 1785 / 1850 – 1880 MHz
Tuning Diagram
Technical Data
430
Same-Band Combiner
1710 – 1740 / 1805 – 1835 MHz 1755 – 1785 / 1850 – 1880 MHz
Frequency/MHz Frequency/MHz
Block Diagram
LTE / LTE /
GSM 1800 GSM 1800
78211230
- Clamp set (type no. 734360 - 734365) and
- 50-Ohm load (type no. 78410367)
(order separately) can be found in the section “System Components”.
431
Same-Band Combiner
1730 – 1750 / 1825 – 1845 MHz 1765 – 1785 / 1860 – 1880 MHz
Tuning Diagram
Technical Data
432
Same-Band Combiner
1730 – 1750 / 1825 – 1845 MHz 1765 – 1785 / 1860 – 1880 MHz
433
Same-Band Combiner (tunable)
1710 − 1785 / 1805 − 1880 MHz 1710 − 1785 / 1805 − 1880 MHz
Technical Data
434
Same-Band Combiner (tunable)
1710 − 1785 / 1805 − 1880 MHz 1710 − 1785 / 1805 − 1880 MHz
435
Same-Band Combiner (tunable)
1920 – 1980 / 2110 – 2170 MHz 1920 ... 1980 / 2110 ... 2170 MHz
• Enables antenna and feeder sharing for two base stations in the same
frequency band
• Customized 10 MHz Tx/Rx bandpass filters (factory tunable) available
for inserting a second UMTS 2100 base station Port 2
• Full pass-band (without the second UMTS 2100 10 MHz Tx/Rx Port 6 Port 1
frequency blocks) available for the first UMTS 2100 base station
• Low insertion loss over complete UMTS 2100 Tx/Rx bandwidth Port 4 Port 3
compared to standard hybrid combiners
• Double unit for XPol antennas
• Suitable for indoor and outdoor applications Port 5
• DC/AISG by-pass for DTMA supply
Tuning Examples
Technical Data
436
Same-Band Combiner (tunable)
1920 – 1980 / 2110 – 2170 MHz 1920 ... 1980 / 2110 ... 2170 MHz
Attenuation/dB
5 0.5
1950 – 1965 2140 – 2155
Rx Tx
10 1.0
1950 – 1965 2140 – 2155
Rx Tx
15 1.5
20 2.0
25 2.5
30 3.0
35 3.5
40 4.0
45 4.5
50 5.0
1900 1930 1960 1990 2020 2050 2080 2110 2140 2170 2200 1900 1930 1960 1990 2020 2050 2080 2110 2140 2170 2200
Frequency/MHz Frequency/MHz
5 0.5
10 1.0
1970 – 1980 2160 – 2170
Rx Tx
15 1.5
1970 – 1980 2160 – 2170
Rx Tx
20 2.0
25 2.5
30 3.0
35 3.5
40 4.0
45 4.5
50 5.0
1900 1930 1960 1990 2020 2050 2080 2110 2140 2170 2200 1900 1930 1960 1990 2020 2050 2080 2110 2140 2170 2200
Frequency/MHz Frequency/MHz
Block Diagram
437
Same-Band Combiner (tunable)
1920 – 1980 / 2110 – 2170 MHz 1920 ... 1980 / 2110 ... 2170 MHz
• Enables antenna and feeder sharing for two base stations in the same
frequency band
• Customized 15 MHz Tx/Rx bandpass filters (factory tunable) available
for inserting a second UMTS 2100 base station
• Full pass-band (without the second UMTS 2100 15 MHz Tx/Rx
frequency blocks) available for the first UMTS 2100 base station
• Low insertion loss over complete UMTS 2100 Tx/Rx bandwidth
compared to standard hybrid combiners
• Double unit for XPol antennas
• Suitable for indoor and outdoor applications
• DC/AISG by-pass for DTMA supply
Tuning Examples
Technical Data
438
Same-Band Combiner (tunable)
1920 – 1980 / 2110 – 2170 MHz 1920 ... 1980 / 2110 ... 2170 MHz
Attenuation/dB
5 0.5
10 1.0
1935 – 1950 2125 – 2140 1935 – 1950 2125 – 2140
Rx Tx Rx Tx
15 1.5
20 2.0
25 2.5
30 3.0
35 3.5
40 4.0
45 4.5
50 5.0
1900 1930 1960 1990 2020 2050 2080 2110 2140 2170 2200 1900 1930 1960 1990 2020 2050 2080 2110 2140 2170 2200
Frequency/MHz Frequency/MHz
5 0.5
10 1.0
1965 – 1980 2155 – 2170
Rx Tx
15 1.5
1965 – 1980 2155 – 2170
Rx Tx
20 2.0
25 2.5
30 3.0
35 3.5
40 4.0
45 4.5
50 5.0
1900 1930 1960 1990 2020 2050 2080 2110 2140 2170 2200 1900 1930 1960 1990 2020 2050 2080 2110 2140 2170 2200
Frequency/MHz Frequency/MHz
Block Diagram
439
Same-Band Combiner
• Enables antenna and feeder sharing for two base stations in the same
frequency band
• Low insertion loss over complete LTE 2600 / TDD 2600 bandwidth compared to
standard hybrid combiners
• Double unit for XPol antennas
• Suitable for indoor or outdoor applications
• DC/AISG by-pass for DTMA supply
Technical Data
440
Same-Band Combiner
441
Same-Band Combiner
2500 – 2520 / 2620 – 2640 MHz 2540 – 2570 / 2660 – 2960 MHz
• Enables antenna and feeder sharing for two base stations in the same
frequency band
• Low insertion loss over complete LTE 2600 bandwidth compared to standard
hybrid combiners
• Double unit for XPol antennas
• Suitable for indoor or outdoor applications
• DC/AISG by-pass for DTMA supply
Technical Data
442
Same-Band Combiner
2500 – 2520 / 2620 – 2640 MHz 2540 – 2570 / 2660 – 2960 MHz
443
3 dB Coupler
Hybrid Combiner 2 : 2
698 − 2690 MHz
Port 1
• Can be used for the decoupled combining of 2 transmitters onto
a common antenna with frequency spacing as narrow as desired
(3 dB loss) - see application example 1 Port 3
• Can be used for the decoupled combining of 2 transmitters onto
two antennas with frequency spacing as narrow as desired - see
application example 2
• Can be used as a decoupled 2-way splitter - see application
example 3
• Suitable for indoor or outdoor applications Port 2
• DC/AISG by-pass
• External DC stop available as an accessory
Port 4
Technical Data
444
3 dB Coupler
Hybrid Combiner 2 : 2
698 − 2690 MHz
445
3 dB Coupler
Hybrid Combiner 2 : 2
698 – 2690 MHz
• Can be used for the decoupled combining of 2 transmitters onto a Port 3
common antenna with frequency spacing as narrow as desired
(3 dB loss) - see application example 1
• Can be used for the decoupled combining of 2 transmitters onto
two antennas with frequency spacing as narrow as desired - see Port 4
application example 2
• Can be used as a decoupled 2-way splitter - see application
example 3
• Can be used as a frequency-independant 90° phase shifter
(90° Hybrid)
Port 1
• Suitable for indoor and outdoor applications
• DC/AISG by-pass Port 2
• External DC stop available as an accessory
Technical Data
446
3 dB Coupler
Hybrid Combiner 2 : 2
698 – 2690 MHz
447
3 dB Coupler
Hybrid Combiner 2:2
800 − 2200 MHz
The 3-dB coupler can be used:
• as a decoupled power splitter with a ratio of 1:1,
• for the decoupled combining of two transmitters with frequency
spacing as narrow as desired (at 3 dB loss),
• for the decoupled combining of two receivers with frequency
spacing as narrow as desired,
• for the decoupled combining of two transmitter/receiver units,
whose integrated duplexers are within the same frequency
range,
• as a frequency-independent 90° phase shifter,
• as a combiner component.
Function:
The 3-dB coupler has four ports, two of which are decoupled
from each other. For example effective power entering into port 1
is distributed into ports 2 and 3. Port 4 is decoupled and without
power if ports 2 and 3 are ideally matched. In practice an absorber
of suitable power at port 4 is to be planned in accordance with the
mismatch of ports 2 and 3.
Decoupled combining can be achieved via the diagonally opposite
ports 2 and 3 or 1 and 4.
Technical Data
Note:
VSWR and attenuation values are measured when the remaining ports are terminated
with 50-Ω loads
448
Filters & System Components
Filters
Smart Bias Tees
Filters & System Components DC-Stops
Attenuators
50 Ω Loads
450