Jotafloor Epc 300 Plus TDS
Jotafloor Epc 300 Plus TDS
Jotafloor Epc 300 Plus TDS
Product description
This is a two component amine cured high volume solid, low VOC epoxy coating. It is a self smoothing, easy to
apply product, leaving a seamless surface. With Jotafloor Non Slip aggregates, enhanced slip resistance is
possible. To be used as finish coat in atmospheric environments.
Typical use
Designed for a wide range of floors with various levels of mechanical exposure. Recommended for workshops,
carparks, garages, factories, laboratories, aircraft hangars and plant rooms where nonslip properties are
required.
Other
Colours
According to colour card
Product data
Property Test/Standard Description
The provided data is typical for factory produced products, subject to slight variation depending on colour.
All data is valid for mixed paint.
Gloss description: According to Jotun Performance Coatings' definition.
Spreading rate depends on film thickness applied, type of texture, surface porosity, imperfections, temperature,
wastage during painting etc.
Surface preparation
To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any
contamination.
Surface preparation
Coated surfaces and Clean, dry and undamaged compatible Clean, dry and undamaged compatible
Concrete coating as per SSPC SP13/NACE NO 6 coating as per SSPC SP13/NACE NO 6
/ASTM D4258 -05 /ACI 503.6R- /ASTM D4258 -05 /ACI 503.6R-
97/SSPC-TR 5/ICRI TECHNICAL 97/SSPC-TR 5/ICRI TECHNICAL
GUIDELINE 03741/NACE02203 GUIDELINE 03741/NACE02203
Laitance deposits are best removed by Planetary diamond disc grinder or by captive blasting followed by vacuum
cleaning to remove dust debris. For old concrete, Jotun technical team should visit the site and appropriate
surface preparation methodology should be recommended and that is to be followed.
Application
Application methods
The product can be applied by
The temperature of the substrate should be minimum 15 °C and at least 3 °C above the dew point of the air,
measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure proper
drying. The moisture content in the substrate should not exceed 4 % (by weight). The coating should not be
exposed to oil, chemicals or mechanical stress until fully cured.
This product should not be applied on to the surfaces which are known to, or likely to suffer from, rising
dampness, potential osmosis problems or have a relative humidity greater than 80% as measured in accordance
with BS 8203 Appendix A.
Component A should be thoroughly stirred before component B is mixed. Mix both the components using a slow
speed drill and mixing paddle for 2 minutes. The entire content should be poured on to a third container and
edges of the container should be scraped. Mix the material for an additional 20 seconds. The mixed material
should be given an induction time of 3 minutes before application. Do not add solvent thinners at any time.
Thinner/Cleaning solvent
Cleaning solvent : Jotun Thinner No. 17
Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal
tackiness.
Walk-on-dry: Minimum time before the coating can tolerate normal foot traffic without permanent marks,
imprints or other physical damage.
Dry to over coat, minimum: The recommended shortest time before the next coat can be applied.
Dry to over coat, maximum, atmospheric: The longest time allowed before the next coat can be applied.
Dried/cured for service: Minimum time before the coating can be permanently exposed to the intended
environment/medium.
Curing at lower temperature than recommended i.e. 15°C would result into blushing & blooming problem.
Exposure to water during curing process will result into adverse effect to the coating.
Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal
tackiness.
Walk-on-dry: Minimum time before the coating can tolerate normal foot traffic without permanent marks,
imprints or other physical damage.
Dry to over coat, minimum: The recommended shortest time before the next coat can be applied.
Dry to over coat, maximum, atmospheric: The longest time allowed before the next coat can be applied.
Dried/cured for service: Minimum time before the coating can be permanently exposed to the intended
environment/medium.
Product compatibility
Recommended Systems
System 1:
Jotafloor SF PR 150 / Jotafloor Sealer HS Refer to product TDS
Jotafloor EPC 300 Plus 200 microns x 1 coat
Non-Slip Aggregates 0.50 - 1 kg per sqm
Jotafloor EPC 300 Plus 200 - 300 microns x 1 coat
System 2:
Jotafloor SF PR 150 / Jotafloor Sealer HS Refer to product TDS
Jotafloor EPC 300 Plus 500 microns x 1 coat
System 3:
Jotafloor EPC 300 Plus 200 - 300 microns x 1 coat
Non-Slip Aggregates 0.50 - 1 kg per sqm
Jotafloor EPC 300 Plus 200 - 300 microns x 1 coat
System 4:
Jotafloor EPC 300 Plus 200 microns x 2 coats
For the direct application of Jotafloor EPC 300 Plus on to the concrete, firstly a thorough inspection of the
concrete should be carried out. All the repairs and imperfections should be carried out using Jotafloor Filler/
Jotafloor Filler Plus.
For porous concrete, a scrape coat of Jotafloor Filler or one or two coats of Jotafloor Sealer/ Jotafloor Sealer HS
is recommended before the application of Jotafloor EPC 300 Plus.
Packaging (typical)
Volume Size of containers
(litres) (litres)
The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary
due to local regulations.
Storage
The product must be stored in accordance with national regulations. Keep the containers in a dry, cool, well
ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle
with care.
Shelf life at 23 °C
Jotafloor EPC 300 Plus Comp A 12 month(s)
Jotafloor EPC 300 Plus Comp B 12 month(s)
In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf
life, thereafter the paint quality is subject to re-inspection.
Caution
This product is for professional use only. The applicators and operators shall be trained, experienced and have
the capability and equipment to mix/stir and apply the coatings correctly and according to Jotun's technical
documentation. Applicators and operators shall use appropriate personal protection equipment when using this
product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit
the site conditions shall be forwarded to the responsible Jotun representative for approval before commencing
the work.
Colour variation
When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations
from batch to batch. Such products may fade and chalk when exposed to sunlight and weathering.
Colour and gloss retention on topcoats/finish coats may vary depending on type of colour, exposure
environment such as temperature, UV intensity etc., and application quality. Contact your local Jotun office for
further information.
Disclaimer
The information in this document is given to the best of Jotun's knowledge, based on laboratory testing and
practical experience. Jotun's products are considered as semi-finished goods and as such, products are often
used under conditions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product
itself. Minor product variations may be implemented in order to comply with local requirements. Jotun reserves
the right to change the given data without further notice.
Users should always consult Jotun for specific guidance on the general suitability of this product for their needs
and specific application practices.
If there is any inconsistency between different language issues of this document, the English (United Kingdom)
version will prevail.