Jotafloor Epc 300 Plus TDS

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Technical Data Sheet

Approved 1,5 46802 epoxy ^(ValidationDate) 1

Jotafloor EPC 300 Plus

Product description
This is a two component amine cured high volume solid, low VOC epoxy coating. It is a self smoothing, easy to
apply product, leaving a seamless surface. With Jotafloor Non Slip aggregates, enhanced slip resistance is
possible. To be used as finish coat in atmospheric environments.

Typical use
Designed for a wide range of floors with various levels of mechanical exposure. Recommended for workshops,
carparks, garages, factories, laboratories, aircraft hangars and plant rooms where nonslip properties are
required.
Other

Approvals and certificates


Determination of Compressive Strength - ASTM C579 and BS 6319-2
Determination of Tensile Strength - ASTM C307
Determination of Flextural Strength - ASTM C580 and BS 6319-3
Determination of Taber Abrasion (1000 Cycles) - ASTM D4060:2010
Determination of Shore D Hardness - ASTM D2240:2005
Determination of Chemical Resistance - ASTM D543
All the tests were carried out at 23±2 °C and 60±5% RH (Relative Humidity). For more details refer test
certificate.

For details about chemicals, refer to the test certificate.

Additional certificates and approvals may be available on request.

Colours
According to colour card

Product data
Property Test/Standard Description

Solids by volume ISO 3233 97 ± 2 %


Gloss level (GU 60 °) ISO 2813 Gloss (Above 70)
Flash point ISO 3679 Method 1 100 °C
Density calculated 1.6 kg/l
VOC-US/Hong Kong US EPA method 24 (tested) 30 g/l
(CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

The provided data is typical for factory produced products, subject to slight variation depending on colour.
All data is valid for mixed paint.
Gloss description: According to Jotun Performance Coatings' definition.

Date of issue: 28 March 2021 Page: 1/6

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotafloor EPC 300 Plus

Film thickness per coat


Typical recommended specification range

Dry film thickness 200 - 500 μm


Wet film thickness 200 - 500 μm
Theoretical spreading rate 4.9 - 1.96 m²/l

Spreading rate depends on film thickness applied, type of texture, surface porosity, imperfections, temperature,
wastage during painting etc.

Surface preparation
To secure lasting adhesion to the subsequent product all surfaces shall be clean, dry and free from any
contamination.

Surface preparation summary table

Surface preparation

Substrate Minimum Recommended

Coated surfaces and Clean, dry and undamaged compatible Clean, dry and undamaged compatible
Concrete coating as per SSPC SP13/NACE NO 6 coating as per SSPC SP13/NACE NO 6
/ASTM D4258 -05 /ACI 503.6R- /ASTM D4258 -05 /ACI 503.6R-
97/SSPC-TR 5/ICRI TECHNICAL 97/SSPC-TR 5/ICRI TECHNICAL
GUIDELINE 03741/NACE02203 GUIDELINE 03741/NACE02203

Laitance deposits are best removed by Planetary diamond disc grinder or by captive blasting followed by vacuum
cleaning to remove dust debris. For old concrete, Jotun technical team should visit the site and appropriate
surface preparation methodology should be recommended and that is to be followed.

Application
Application methods
The product can be applied by

Brush: Recommended to paint corners and edges.


Roller: Use small fibre pile 2 roller.

Conditions during application :

The temperature of the substrate should be minimum 15 °C and at least 3 °C above the dew point of the air,
measured in the vicinity of the substrate. Good ventilation is usually required in confined areas to ensure proper
drying. The moisture content in the substrate should not exceed 4 % (by weight). The coating should not be
exposed to oil, chemicals or mechanical stress until fully cured.
This product should not be applied on to the surfaces which are known to, or likely to suffer from, rising
dampness, potential osmosis problems or have a relative humidity greater than 80% as measured in accordance
with BS 8203 Appendix A.

Date of issue: 28 March 2021 Page: 2/6

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotafloor EPC 300 Plus

Product mixing ratio (by volume)

Jotafloor EPC 300 Plus Comp A 4 part(s)


Jotafloor EPC 300 Plus Comp B 1 part(s)

No part mixing of this product.


Use a slow speed drill and mixing paddle.
The temperature of base and curing agent should be 18°C or higher when the paint is mixed.

Component A should be thoroughly stirred before component B is mixed. Mix both the components using a slow
speed drill and mixing paddle for 2 minutes. The entire content should be poured on to a third container and
edges of the container should be scraped. Mix the material for an additional 20 seconds. The mixed material
should be given an induction time of 3 minutes before application. Do not add solvent thinners at any time.

Thinner/Cleaning solvent
Cleaning solvent : Jotun Thinner No. 17

Thinning of the product is not recommended.

Drying and Curing time


Substrate temperature 15 °C 23 °C 40 °C

Surface (touch) dry 48 h 16 h 5.5 h


Walk-on-dry 48 h 18 h 6.5 h
Dry to over coat, minimum 48 h 24 h 8h
Dry to over coat, maximum, atmospheric 72 h 48 h 24 h
Dried/cured for service 14 d 7d 3d

Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal
tackiness.

Walk-on-dry: Minimum time before the coating can tolerate normal foot traffic without permanent marks,
imprints or other physical damage.

Dry to over coat, minimum: The recommended shortest time before the next coat can be applied.

Dry to over coat, maximum, atmospheric: The longest time allowed before the next coat can be applied.

Dried/cured for service: Minimum time before the coating can be permanently exposed to the intended
environment/medium.

Curing at lower temperature than recommended i.e. 15°C would result into blushing & blooming problem.
Exposure to water during curing process will result into adverse effect to the coating.

Surface (touch) dry: The state of drying when slight pressure with a finger does not leave an imprint or reveal
tackiness.

Walk-on-dry: Minimum time before the coating can tolerate normal foot traffic without permanent marks,
imprints or other physical damage.

Dry to over coat, minimum: The recommended shortest time before the next coat can be applied.

Dry to over coat, maximum, atmospheric: The longest time allowed before the next coat can be applied.

Dried/cured for service: Minimum time before the coating can be permanently exposed to the intended
environment/medium.

Date of issue: 28 March 2021 Page: 3/6

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotafloor EPC 300 Plus

Induction time and Pot life


Paint temperature 23 °C

Induction time 3 min,


Recommended.

Pot life 25 min

Product compatibility

Previous coat: Jotafloor Sealer or Jotafloor SF PR 150 or Jotafloor Sealer HS


Subsequent coat: Jotafloor PU Topcoat or Jotafloor PU Topcoat HS or Jotafloor Topcoat or Jotafloor
Topcoat E

Recommended Systems
System 1:
Jotafloor SF PR 150 / Jotafloor Sealer HS Refer to product TDS
Jotafloor EPC 300 Plus 200 microns x 1 coat
Non-Slip Aggregates 0.50 - 1 kg per sqm
Jotafloor EPC 300 Plus 200 - 300 microns x 1 coat

System 2:
Jotafloor SF PR 150 / Jotafloor Sealer HS Refer to product TDS
Jotafloor EPC 300 Plus 500 microns x 1 coat

System 3:
Jotafloor EPC 300 Plus 200 - 300 microns x 1 coat
Non-Slip Aggregates 0.50 - 1 kg per sqm
Jotafloor EPC 300 Plus 200 - 300 microns x 1 coat

System 4:
Jotafloor EPC 300 Plus 200 microns x 2 coats

For System 3 & 4 (Direct to concrete application)


Surface preparation to be done as per the mentioned recommended guidelines:

For the direct application of Jotafloor EPC 300 Plus on to the concrete, firstly a thorough inspection of the
concrete should be carried out. All the repairs and imperfections should be carried out using Jotafloor Filler/
Jotafloor Filler Plus.

For porous concrete, a scrape coat of Jotafloor Filler or one or two coats of Jotafloor Sealer/ Jotafloor Sealer HS
is recommended before the application of Jotafloor EPC 300 Plus.

Packaging (typical)
Volume Size of containers
(litres) (litres)

Jotafloor EPC 300 Plus Comp A 14.4 20


Jotafloor EPC 300 Plus Comp B 3.6 5

The volume stated is for factory made colours. Note that local variants in pack size and filled volumes can vary
due to local regulations.

Date of issue: 28 March 2021 Page: 4/6

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotafloor EPC 300 Plus

Storage
The product must be stored in accordance with national regulations. Keep the containers in a dry, cool, well
ventilated space and away from sources of heat and ignition. Containers must be kept tightly closed. Handle
with care.

Shelf life at 23 °C
Jotafloor EPC 300 Plus Comp A 12 month(s)
Jotafloor EPC 300 Plus Comp B 12 month(s)

In some markets commercial shelf life can be dictated shorter by local legislation. The above is minimum shelf
life, thereafter the paint quality is subject to re-inspection.

Green Building Standards


The declared product contributes to Green Building Standard credits by meeting the following specific
requirements

LEED®v4 (2013) / LEED®v4.1 (2020):


EQ credit: Low emitting materials
- VOC content for Concrete/Masonry Sealers (100 g/l) (CARB(SCM)2007) and emission less or equal to 0.5 mg/
m³ (CDPH method 1.2).
MR credit: Building product disclosure and optimization
- Material Ingredients, Option 2: Material Ingredient Optimization, International Alternative Compliance Path -
REACH optimization: Fully inventoried chemical ingredients to 100 ppm and not containing substances on the
REACH Authorization list – Annex XIV, the Restriction list – Annex XVII and the SVHC candidate list.
- Environmental Product Declarations. Product-specific Type III EPD (ISO 14025;21930, EN 15804).

BREEAM® International (2016)


- Hea 02: VOC exemplary emission CDPH method 1.2 (2017)) and the VOC content for Two-pack reactive
performance coatings for specific end use such as floors (80g/L).
- Mat 01: Product-specific Type III EPD (ISO 14025;21930, EN 15804).

Additional certificates and approvals may be available on request.

Caution
This product is for professional use only. The applicators and operators shall be trained, experienced and have
the capability and equipment to mix/stir and apply the coatings correctly and according to Jotun's technical
documentation. Applicators and operators shall use appropriate personal protection equipment when using this
product. This guideline is given based on the current knowledge of the product. Any suggested deviation to suit
the site conditions shall be forwarded to the responsible Jotun representative for approval before commencing
the work.

Health and safety


Please observe the precautionary notices displayed on the container. Use under well ventilated conditions. Do
not inhale spray mist. Avoid skin contact. Spillage on the skin should immediately be removed with suitable
cleanser, soap and water. Eyes should be well flushed with water and medical attention sought immediately.

Colour variation

Date of issue: 28 March 2021 Page: 5/6

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com
Technical Data Sheet
Jotafloor EPC 300 Plus

When applicable, products primarily meant for use as primers or antifoulings may have slight colour variations
from batch to batch. Such products may fade and chalk when exposed to sunlight and weathering.

Colour and gloss retention on topcoats/finish coats may vary depending on type of colour, exposure
environment such as temperature, UV intensity etc., and application quality. Contact your local Jotun office for
further information.

Disclaimer
The information in this document is given to the best of Jotun's knowledge, based on laboratory testing and
practical experience. Jotun's products are considered as semi-finished goods and as such, products are often
used under conditions beyond Jotun's control. Jotun cannot guarantee anything but the quality of the product
itself. Minor product variations may be implemented in order to comply with local requirements. Jotun reserves
the right to change the given data without further notice.

Users should always consult Jotun for specific guidance on the general suitability of this product for their needs
and specific application practices.

If there is any inconsistency between different language issues of this document, the English (United Kingdom)
version will prevail.

Date of issue: 28 March 2021 Page: 6/6

This Technical Data Sheet supersedes those previously issued.


The Technical Data Sheet (TDS) is recommended to be read in conjunction with the Safety Data Sheet (SDS) and the
Application Guide (AG) for this product. For your nearest local Jotun office, please visit our website at www.jotun.com

You might also like