Insert Pump Anchor

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

Reciprocating Rod Lift

Insert Pump Anchor

Weatherford’s insert pump anchor provides a trouble-free method of anchoring


and packing off a pump in wells where a pump-seating nipple has not been
provided. These design features add flexibility and economy to many pumping
installations, making the anchor a logical choice for many operators. The pump
anchor enables the operator to select the best pump setting depth after the well
is completed and tubing has been run. Additionally, it eliminates the need to pull
tubing for deep tubing leaks or replacing a faulty shoe or seating nipple.
The pump anchor’s robust design provides durability that makes planned
multistep programs — lowering the pump setting depth in steps as the fluid
level declines — practical for further economies to improve operational efficiency.

Applications
• As a casing packer in slimhole completions or as a removable
packoff in subsurface hydraulic-pump installations
• 2 3/8-, 2 7/8-, and 3 1/2-in. tubing strings

Features, Advantages and Benefits


• The insert pump anchor offers complete vertical action — sets, packs off,
releases, and resets without rotation — eliminating the need to pull tubing
for proper depth setting of the pump.
• Self-locking collet design sets and releases packing and slips without jamming
or presetting, enhancing operational safety.
• The split cone ensures a reliable initial hold-down force, and is backed up with
an alloy retainer ring to provide the strength characteristics of a solid cone.
• An improved compression packing element is bonded to a threaded steel insert,
eliminating damage to the packoff when the anchor is set, released, or reset.
• The anchor is automatically positioned for resetting when released and can
be raised, lowered, and reset without pulling from the tubing, maximizing
operational efficiency.

weatherford.com 1 © 2006–2011 Weatherford. All rights reserved. 848.01


Reciprocating Rod Lift

Insert Pump Anchor

Options
• Furnished with a standard 24-in. setting stroke in all sizes
• Available with a long 48-in. stroke in the 2 3/8-in. and 2 7/8-in. sizes
• For high-temperature applications, Viton® packing element is available

Specifications

OD Minimum Yield Tensile Strength Working Pressure


Makeup Length
(in./mm) (lb/kg) (lb/kN) (psi/bar)

1-11/16 51,800 59,800


42.86 23,496 266.0
2 79,900 92,200 5,000
Variable
50.80 36,242 410.1 345
2-1/2 77,800 97,900
63.50 35,289 435.5

Operating Sequence
1. Record pump stroke and the setting stroke #6. Lifting
(24 in. or 48 in.) of the anchor. These two figures Position: #1. Starting
represent the upward movement of the rod string Pin returns Position:
here as tool is Pin is here as
necessary to transfer the dowel pin from the unseated, where tool is made
running slot to the setting slot. it remains as up on string.
tool is lifted
2. Attach the anchor to the pump and start installing into up tubing.
#2. Lowering
the tubing with the dowel pin in the starting position. Position:
#5. Setting
Pin moves
3. Run the pump to the desired depth, attach the Position:
here as tool
Approximate pin
polished rod, and lower to the point established enters tubing.
location when
for bottom of the stroke. tool is “set.”
#3. Running
4. Raise the polished rod the distance established in Slot:
Step 1 and then lower the full weight of the rods #4. Setting Pin travels up
Slot: and down the
onto the anchor to set and preload the packoff. “running slot”
Pin moves to
presetting position as connections
To reset the anchor, unseat with a straight pull on the
in “setting slot” are made.
rod string, raise or lower to the desired setting position, as rods are lifted
and then reset as in Step 3. for setting. Tool is
then lowered to
set position.
Viton a registered trademark of DuPont Dow Elastomers L.L.C.

weatherford.com 2 © 2006–2011 Weatherford. All rights reserved. 848.01

You might also like