2/2 Solenoid Directional Valve Poppet Type, Pilot Operated Normally Open UNF Cartridge - 350 Bar
2/2 Solenoid Directional Valve Poppet Type, Pilot Operated Normally Open UNF Cartridge - 350 Bar
2/2 Solenoid Directional Valve Poppet Type, Pilot Operated Normally Open UNF Cartridge - 350 Bar
FUNCTION FEATURES
zz Coil seals protect the solenoid system
zz Wide variety of connectors available
zz Excellent switching performance by high power HYDAC solenoid
zz Exposed surfaces zinc-nickel plated for increased corrosion protection
(1.000 h Salt spray test)
SPECIFICATIONS*
Operating pressure: max. 350 bar
Nominal flow: max. 75 l/min
Leakage: Leakage-free
max. 5 drops/min (0.25 cm³/min) at 350 bar
Media operating temperature range: min. -20 °C to max. +100 °C
Ambient temperature range: min. -20 °C to max. + 60 °C
Operating fluid: Hydraulic oil to DIN 51524 Part 1, 2 and 3
Viscosity range: min. 7.4 mm²/s to max. 420 mm²/s
Filtration: Class 21/19/16 according to ISO 4406 or
cleaner
MTTFd: 150 - 1200 years,
according to DIN EN ISO 13849-1
Installation: No orientation restrictions
Materials: Valve body: free-cutting steel
Piston: hardened and
ground steel
Seals: NBR (standard)
FKM (optional, media
temperature range
-20 °C to +120 °C)
Back-up rings: PTFE
Coil: Steel/Polyamide
Cavity: FC10-2
Weight: Valve complete: 0.37 kg
Coil only: 0.19 kg
The directional valve is a pilot operated Electrical data
valve in poppet style. Response time: energized: approx. 35 ms
When de-energized, there is free flow (at pmax, Qmax, ν = 34 mm²/s) de-energized: approx. 50 ms
through the valve from port 2 to substantially extended response times
port 1. Flow is not possible in the reverse possible at other operating conditions
direction. When the solenoid coil is Type of voltage: DC: direct current solenoid
energized, the valve is closed from port AC: a lternating current solenoid with a
2 to port 1. In the reverse direction the bridge rectifier built into the coil
valve will allow flow from port 1 to 2
Current draw at 20 °C: 1.5 A at 12 V DC
when the hydraulic force on the piston
0.8 A at 24 V DC
overcomes the solenoid force (approx.
Voltage tolerance: ± 15 % of the nominal voltage
EN 5.914.5/11.18
2.5 to 10 bar).
Please mind: In pilot operated solenoid Coil duty rating: Continuous up to max. 115 %
valves, shift performance and response of the nominal voltage at
times depend i.a. very much on pressure 60 °C ambient temperature
drop and volume flow during actuation. Coil type: Coil…-40-1836
* see "Conditions and instructions for valves" in brochure 53.000
1
DIMENSIONS MODEL CODE
WS10Y – 01 M – C – N – 24 DG
Basic model
Directional poppet valve, UNF
Type
01 = standard
Manual override
no details = without manual override
M = manual override
Body and ports*
hex. 1"
torque*
C = cartridge only
Seals
N = NBR (standard)
V = FKM
Coil voltage
DC voltages
Manual override, with
12 = 12 V DC
HNBR-rubber cap. 24 = 24 V DC
AC voltages (bridge rectifier built into the coil)
115 = 115 V AC
After loosening knurled nut, coil 230 = 230 V AC
can be rotated through 360° and
removed. Other voltages on request
Torque
Coil connectors (type 40-1836)
DC: DG = DIN connector type A to EN 175301-803
without man.
4+1 Nm
DK = KOSTAL threaded connection M27x1
override
FC10-2
Seal kits
Code Material Part No.
FS UNF 10/N NBR 3651557
FS UNF 10/V FKM 3651559
TYPICAL PERFORMANCE
fitting depth
deenergized
Pressure drop
VE = Visual Examination
* Allowed drilling zone (for manifold design)
** Sharp edges should be avoided by rounding Flow rate
to a radius of 0.1 mm to 0.2 mm
*** largest pre-drilling diameter
(nominal tool diameter)
Form tools
EN 5.914.5/11.18